40.00% 40.00%

Publicador:

Resumo:

In this paper we report the preparation and dielectric properties of poly o-toluidine:poly vinyl chloride composites in pellet and film forms. The composites were prepared using ammonium persulfate initiator and HCl dopant. The characterization is done by TGA and DSC. The dielectric properties including dielectric loss, conductivity, dielectric constant, dielectric heating coefficient, absorption coefficient, and penetration depth were studied in the microwave field. An HP8510 vector network analyzer with rectangular cavity resonator was used for the study. Sbands (2-4 GHz), C band (5-8 GHz), and X band (8-12 GHz) frequencies were used in the microwave field. Comparisons between the pellet and film forms of composites were also included. The result shows that the dielectric properties in the microwave field are dependent on the frequency and on the method of preparation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The forms of natural rubber studied were sheet [RSS 4 and RSS 5], ISNR 20 and EBC. In the case of the latter two forms samples from estate and nonestate sectors were included. The samples were collected from different locations at specified intervals, for a particular period. The effect of the extent of mastication on raw rubber properties as well as the properties of the compounds and vulcanizates also studied. The consistency in raw rubber properties and breakdown behavior of skim rubber were studied by collecting samples periodically from selected processing units. The effect of incorporation of skim with ISNR 20 has also been investigated

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Three experiments examine the effect of different forms of computer-generated advice on concurrent and subsequent performance of individuals controlling a simulated intensive-care task. Experiment 1 investigates the effect of optional and compulsory advice and shows that both result in an improvement in subjects' performance while receiving the advice, and also in an improvement in subsequent unaided performance. However, although the advice compliance displayed by the optional advice group shows a strong correlation with subsequent unaided performance, compulsory advice has no extra benefit over the optional use of advice. Experiment 2 examines the effect of providing users with on-line explanations of the advice, as well as providing less specific advice. The results show that both groups perform at the same level on the task as the advice groups from Experiment 1, although subjects receiving explanations scored significantly higher on a written post-task questionnaire. Experiment 3 investigates in more detail the relationship between advice compliance and performance. The results reveal a complex relationship between natural ability on the task and the following of advice, in that people who use the advice more tend to perform either better or worse than the more moderate users. The theoretical and practical implications of these experiments are discussed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We focus on the comparison of three statistical models used to estimate the treatment effect in metaanalysis when individually pooled data are available. The models are two conventional models, namely a multi-level and a model based upon an approximate likelihood, and a newly developed model, the profile likelihood model which might be viewed as an extension of the Mantel-Haenszel approach. To exemplify these methods, we use results from a meta-analysis of 22 trials to prevent respiratory tract infections. We show that by using the multi-level approach, in the case of baseline heterogeneity, the number of clusters or components is considerably over-estimated. The approximate and profile likelihood method showed nearly the same pattern for the treatment effect distribution. To provide more evidence two simulation studies are accomplished. The profile likelihood can be considered as a clear alternative to the approximate likelihood model. In the case of strong baseline heterogeneity, the profile likelihood method shows superior behaviour when compared with the multi-level model. Copyright (C) 2006 John Wiley & Sons, Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose The relative efficiency of different eye exercise regimes is unclear, and in particular the influences of practice, placebo and the amount of effort required are rarely considered. This study measured conventional clinical measures after different regimes in typical young adults. Methods 156 asymptomatic young adults were directed to carry out eye exercises 3 times daily for two weeks. Exercises were directed at improving blur responses (accommodation), disparity responses (convergence), both in a naturalistic relationship, convergence in excess of accommodation, accommodation in excess of convergence, and a placebo regime. They were compared to two control groups, neither of which were given exercises, but the second of which were asked to make maximum effort during the second testing. Results Instruction set and participant effort were more effective than many exercises. Convergence exercises independent of accommodation were the most effective treatment, followed by accommodation exercises, and both regimes resulted in changes in both vergence and accommodation test responses. Exercises targeting convergence and accommodation working together were less effective than those where they were separated. Accommodation measures were prone to large instruction/effort effects and monocular accommodation facility was subject to large practice effects. Conclusions Separating convergence and accommodation exercises seemed more effective than exercising both systems concurrently and suggests that stimulation of accommodation and convergence may act in an additive fashion to aid responses. Instruction/effort effects are large and should be carefully controlled if claims for the efficacy of any exercise regime are to be made.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study analyses soil organic carbon (SOC) and hot-water extractable carbon (HWC), both measures of soil quality, under different land management: (1) conventional tillage (CT); (2) CT plus the addition of oil mill waste alperujo (A); (3) CT plus the addition of oil mill waste olive leaves (L); (4) no tillage with chipped pruned branches (NT1); and (5) no tillage with chipped pruned branches and weeds (NT2); in a typical Mediterranean agricultural area; the olive groves of Andalucía, southern Spain. SOC values in CT, A, NT1 and NT2 decreased with depth, but in NT2 the surface horizon (0-5 cm) had higher values than the other treatments, 47% more than the average values in the other three soils. In L, SOC also decreased with depth, although there was an increase of 88.5% from the first (0-10 cm) to the second horizon (10-16 cm). Total SOC stock values were very similar under A (101.9 Mg ha−1), CT (101.7 Mg ha−1), NT1 (105.8 Mg ha−1) and NT2 (111.3 Mg ha−1, if we consider the same depth of the others). However, SOC under L was significantly higher (p < 0.05) at 250.2 Mg ha−1. HWC decreased with depth in A, CT and NT1. NT2 and L followed the same pattern as the other management types but with a higher value in the surface horizon (2.3 and 4.9 mg g−1 respectively). Overall, our results indicate that application of oil mill waste olive leaves under CT (L) is a good management practice to improve SOC and reduce waste.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A sequential extraction method was utilized to analyze seven forms of P in an integrated vertical-flow constructed wetland (IVFCW) containing earthworms and different substrates. The aluminum-bound P (Al-P) content was found to be lower, and the occluded P (Oc-P) content was higher in the IVFCW. The addition of earthworms into the influent chamber of IVFCW increased the exchange P (Ex-P), iron-bound P (Fe-P), calcium bound P (Ca-P), Oc-P, detritus-bound (De-P) and organic P (Org-P) content in the influent chamber, and also enhanced P content uptake by wetland plants. A significantly positive correlation between P content of above-ground wetland plants and the Ex-P, Fe-P, Oc-P and Org-P content in the rhizosphere was found (P < 0.05), which indicated that the Ex-P, Fe-P, Oc-P and Org-P could be bio-available P. The Ex-P, Fe-P, De-P, Oc-P and Ca-P content of the influent chamber was higher where the substrate contained a mixture of Qing sand and river sand rather than only river sand. Also the IVFCW with earthworms and both Qing sand and river sand had a higher removal efficiency of P, which was related to higher P content uptake by wetland plants and P retained in IVFCW. These findings suggest that addition of earthworms in IVFCW increases the bioavailable P content, resulting in enhanced P content uptake by wetland plants.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: The purpose of this study was to compare and evaluate bone and soft tissue levels between immediately placed, immediately restored implants positioned in the esthetic anterior region with different interimplant distances (IID). Methods: Forty-nine patients requiring multiple implant restorations in the anterior regions received 152 implants, which were restored immediately. Periapical radiographs and digital images of 99 interimplant sites were taken at the regular follow-up examinations at 0, 6, 12, and 24 months after surgery. They were digitally recorded and analyzed. The presence of the interproximal papilla was assessed and compared to the distances between the bone crest and the contact point between the natural teeth and the restoration crowns. Results: Implants with an IID <2 mm seemed to lose less bone laterally. When the IID was <2 mm, vertical crestal bone loss was significantly greater than in the group with IID >4 mm. The percentage of the interproximal papilla presence decreased when the distance between the bone crest and the contact point between the two restoration crowns was >6 mm and when two implants were placed at a distance >= 4 mm. Conclusions: To guarantee a better esthetic result in immediately placed, immediately restored implants, the contact point between the two prosthetic crowns should be placed at 3 to 4 mm, and never >6 mm, from the bone peak. Two adjacent implants should be placed at a distance >2 and <4 mm.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Nesse artigo, tem-se o interesse em avaliar diferentes estratégias de estimação de parâmetros para um modelo de regressão linear múltipla. Para a estimação dos parâmetros do modelo foram utilizados dados de um ensaio clínico em que o interesse foi verificar se o ensaio mecânico da propriedade de força máxima (EM-FM) está associada com a massa femoral, com o diâmetro femoral e com o grupo experimental de ratas ovariectomizadas da raça Rattus norvegicus albinus, variedade Wistar. Para a estimação dos parâmetros do modelo serão comparadas três metodologias: a metodologia clássica, baseada no método dos mínimos quadrados; a metodologia Bayesiana, baseada no teorema de Bayes; e o método Bootstrap, baseado em processos de reamostragem.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The work reported here involved an investigation into the grinding process, one of the last finishing processes carried out on a production line. Although several input parameters are involved in this process, attention today focuses strongly on the form and amount of cutting fluid employed, since these substances may be seriously pernicious to human health and to the environment, and involve high purchasing and maintenance costs when utilized and stored incorrectly. The type and amount of cutting fluid used directly affect some of the main output variables of the grinding process which are analyzed here, such as tangential cutting force, specific grinding energy, acoustic emission, diametrical wear, roughness, residual stress and scanning electron microscopy. To analyze the influence of these variables, an optimised fluid application methodology was developed (involving rounded 5, 4 and 3 turn diameter nozzles and high fluid application pressures) to reduce the amount of fluid used in the grinding process and improve its performance in comparison with the conventional fluid application method (of diffuser nozzles and lower fluid application pressure). To this end, two types of cutting fluid (a 5% synthetic emulsion and neat oil) and two abrasive tools (an aluminium oxide and a superabrasive CBN grinding wheel) were used. The results revealed that, in every situation, the optimised application of cutting fluid significantly improved the efficiency of the process, particularly the combined use of neat oil and CBN grinding wheel. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aims of this in vivo study were to compare the effectiveness and color stability of at-home and in-office bleaching techniques and to evaluate whether the use of light sources can alter bleaching results. According to preestablished criteria, 40 patients were selected and randomly divided into four groups according to bleaching treatment: (1) at-home bleaching with 10% carbamide peroxide, (2) in-office bleaching with 35% hydrogen peroxide (HP) without a light source, (3) in-office bleaching with 35% HP with quartz-tungsten-halogen light, and (4) in-office bleaching with 35% HP with a light-emitting diode/laser. Tooth shade was evaluated using the VITA Classical Shade Guide before bleaching as well as after the first and third weeks of bleaching. Tooth shade was evaluated again using the same guide 1 and 6 months after the completion of treatment. The shade guide was arranged to yield scores that were used for statistical comparison. Statistical analysis using the Kruskal-Wallis test showed no significant differences among the groups for any time point (P > .01). There was no color rebound in any of the groups. The bleaching techniques tested were equally effective. Light sources are unnecessary to bleach teeth. (Int J Periodontics Restorative Dent 2012;32:303-309.)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: The aim of the present study was to evaluate clinical and radiographic changes that occur around dental implants inserted in different levels in relation to crestal bone under different restoration protocols.Methods: Thirty-six implants were inserted in the edentulous mandible of six mongrel dogs. Each implant was assigned to an experimental group according to the distance from the top of the implant to the crestal bone: Bone Level (at crestal bone level), Minus 1 (1 mm below crestal bone), or Minus 2 (2 mm below crestal bone). Each hemimandible was submitted to a restoration protocol: conventional (prosthesis was installed 120 days after implant placement, including 30 days with healing cap) or immediate (prosthesis was installed 24 hours after implant placement). Fixed partial prostheses were installed bilaterally in the same day. After 90 days, clinical and radiographic parameters were evaluated.Results: As long as the implants were inserted in more apical positions, the first bone-to-implant contact (fBIC) was positioned more apically (P<0.05). However, the apical positioning of the implants did not influence the ridge loss or the position of the soft tissue margin (PSTM) (P>0.05). In addition, in immediately restored sites, the PSTM was located significantly more coronally than that in conventionally restored sites (P=0.02).Conclusions: Despite the more apical positioning of the fBIC, the height of the peri-implant soft tissues and ridge was not jeopardized. Moreover, the immediate restoration protocol was beneficial to the maintenance of the PSTM. Further studies are suggested to evaluate the significance of these results in longer healing periods.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)