921 resultados para DEEP-CAVITY
Resumo:
In a recent study of the self-adjoint extensions of the Hamiltonian of a particle confined to a finite region of space, in which we generalized the Heisenberg uncertainty relation to a finite volume, we encountered bound states localized at the wall of the cavity. In this paper, we study this situation in detail both for a free particle and for a hydrogen atom centered in a spherical cavity. For appropriate values of the self-adjoint extension parameter, the bound states localized at the wall resonate with the standard hydrogen bound states. We also examine the accidental symmetry generated by the Runge–Lenz vector, which is explicitly broken in a spherical cavity with general Robin boundary conditions. However, for specific radii of the confining sphere, a remnant of the accidental symmetry persists. The same is true for an electron moving on the surface of a finite circular cone, bound to its tip by a 1/r1/r potential.
Resumo:
Ilio-femoral deep vein thrombosis (DVT) has a high rate of long-term morbidity in the form of the postthrombotic syndrome (PTS). Therefore, management of acute thrombosis should not only focus on the prevention of acute complications such as propagation or embolisation of the initial clot but also on preventing PTS and recurrent thrombosis. Contemporary catheter-based treatments of deep vein thrombosis have proven to be safe and effective in selected patients. Current guidelines recommend medical therapy with anticoagulation alone for all but the most severe, limb-threatening thrombosis. They additionally allow for consideration of catheter-based treatment in patients with acute DVT and low risk of bleeding complications to prevent PTS. Recent studies favoring interventional therapy have not been included in these guidelines. Data on long-term outcome is expected to be published soon, clarifying and very likely strengthening the role of catheter-based treatments in the management of acute ilio-femoral DVT.
Resumo:
This report describes the use of transluminal coil embolization to treat pseudoaneurysm of deep femoral artery branch in two patients. The pseudoaneurysms had developed after coronary angiographv in one patient and after hip replacement in the other. Immediate control angiography after embolization procedures demonstrated complete closure of the pseudoaneurysms. During follow-up of 19 and 3 months, respectively, there was no recurrent bleeding. The aim of this case report is to show the advances in endovascular microcatheter technology, and embolic materials, that made percutaneous transluminal embolization of arterial pseudoaneurysms safe and efficient. In addition, it keeps the medical personnel aware of vascular injuries at the access site related to endovascular procedures as well as vascular complications of total hip arthroplasty. It calls their attention to the possibility of endovascular treatment as an alternative to surgery.
Resumo:
The purpose of this study was to investigate lymphatic clearance of the human skin in patients with acute deep thrombosis of the femoral vein. In 13 patients with deep vein thrombosis and no other cause for swelling of the limbs, lymphatic clearance of the skin at the foot was measured. Ten microliters of fluorescein isothiocyanatedextran 150,000 were injected intradermally and the fluorescent light intensity of the deposit measured 10 min and 24 hours after injection by window densitometry. In addition, intralymphatic pressure was measured by the servo-nulling system. The results were compared with a sex- and age-matched control group. Fluorescent light intensity decreased by 23.8 +/- 12.3 arbitrary units or by a factor of 1.8 +/- 0.5 in patients with DVT after 24 hours, which was significantly less than in healthy controls (33.7 +/- 8.9 arbitrary units or by factor 5.0 +/- 4.1, p < 0.013). Intralymphatic pressure was not different between the two groups. These results indicate that lymphatic clearance is significantly reduced in the acute phase of deep venous thrombosis.
Resumo:
BACKGROUND: Supraomohyoid neck dissection (SOHND) is currently performed in patients with carcinoma of the oral cavity with clinically negative neck. Most investigators consider SOHND as a staging procedure. METHODS: Records of 100 patients with cancer of the oral cavity and clinically negative neck undergoing SOHND were reviewed. The rate and significance of occult metastases are evaluated, the neck recurrences are analyzed and the indication of adjuvant radiation of pN+ necks is discussed. RESULTS: In 34 of 1814 of analyzed lymph nodes, metastatic disease was detected as follows: 30 macrometastases and 4 micrometastases. In 13 of 34 metastases (38%), extracapsular spread was observed. Twenty of 100 patients (20%) had to be upstaged. In 9 of 87 (10%) patients without local recurrence and with a minimal follow-up of 24 months, 5 ipsilateral (4 within the dissection field) and 5 contralateral neck recurrences were observed. Regional recurrence developed in 4% and 35% of patients with pN0 and pN+ necks, respectively. CONCLUSIONS: In 20% of patients with oral cavity tumors and pN0 neck, occult metastases were disclosed. Neck recurrences developed significantly more often in patients with pN+ than in those with pN0 necks. To evaluate the exact indication for an adjuvant treatment of patients with cN0/pN+ necks, prospective studies should be performed.
Resumo:
Class II cavities were prepared in extracted lower molars filled and cured in three 2-mm increments using a metal matrix. Three composites (Spectrum TPH A4, Ceram X mono M7 and Tetric Ceram A4) were cured with both the SmartLite PS LED LCU and the Spectrum 800 continuous cure halogen LCU using curing cycles of 10, 20 and 40 seconds. Each increment was cured before adding the next. After a seven-day incubation period, the composite specimens were removed from the teeth, embedded in self-curing resin and ground to half the orofacial width. Knoop microhardness was determined 100, 200, 500, 1000, 1500, 2500, 3500, 4500 and 5500 microm from the occlusal surface at a distance of 150 microm and 1000 microm from the metal matrix. The total degree of polymerization of a composite specimen for any given curing time and curing light was determined by calculating the area under the hardness curve. Hardness values 150 microm from the metal matrix never reached maximum values and were generally lower than those 1000 microm from the matrix. The hardest composite was usually encountered between 200 microm and 1000 microm from the occlusal surface. For every composite-curing time combination, there was an increase in microhardness at the top of each increment (measurements at 500, 2500 and 4500 microm) and a decrease towards the bottom of each increment (measurements at 1500, 3500 and 5500 microm). Longer curing times were usually combined with harder composite samples. Spectrum TPH composite was the only composite showing a satisfactory degree of polymerization for all three curing times and both LCUs. Multiple linear regression showed that only the curing time (p < 0.001) and composite material (p < 0.001) had a significant association with the degree of polymerization. The degree of polymerization achieved by the LED LCU was not significantly different from that achieved by the halogen LCU (p = 0.54).
Resumo:
Focal osteochondral defects are still a challenging problem in joint surgery. We have developed a two-layered implant consisting of a basal porous beta-tricalcium phosphate (TCP) for bone reconstruction and a superficial fibrous collagen type I/III layer for cartilage regeneration. Fifty-four osteochondral defects in the trochlear groove of 27 Göttinger Minipigs were created and either left untreated, treated with the implant alone, or the implant augmented with an additional growth factor mixture, which was assumed to stimulate cell and tissue differentiation. Follow-up was 6, 12 and 52 weeks with n=6 for each group. The repair tissue was evaluated for its gross appearance and biomechanical properties. Histological sections were semi-quantitatively scored for their histomorphological structure. Treatment with the two-layered implant improved defect filling and subchondral bone repair at 6 and 12 weeks follow-up. The TCP was replaced by cancellous bone at 52 weeks. Cartilage repair tissue mainly consisted of fibrocartilage and showed a moderate cell density up to the joint surface. Growth factor treatment improved the mechanical and histomorphological properties of the cartilage repair tissue at 12, but not at 52 weeks postoperatively. In conclusion, the two-layered collagen-TCP implant augmented with chondroinductive growth factors seems a promising new option for the treatment of deep osteochondral defects in joint surgery.