916 resultados para DC voltage droop control


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A linearly-tunable ULV transconductor featuring excellent stability of the processed signal common-mode voltage upon tuning, critical for very-low voltage applications, is presented. Its employment to the synthesis of CMOS gm-C high-frequency and voiceband filters is discussed. SPICE data describe the filter characteristics. For a 1.3 V-supply, their nominal passband frequencies are 1.0 MHz and 3.78 KHz, respectively, with tuning rates of 12.52 KHz/mV and 0.16 KHz/m V, input-referred noise spectral density of 1.3 μV/Hz1/2 and 5.0μV/Hz1/2 and standby consumption of 0.87 mW and 11.8 μW. Large-signal distortion given by THD = 1% corresponds to a differential output-swing of 360 mVpp and 480 mVpp, respectively. Common-mode voltage deviation is less than 4 mV over tuning interval.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a novel isolated electronic ballast for multiple fluorescent lamps, featuring high power-factor, and high efficiency. Two stages compose this new electronic ballast, namely, a new voltage step-down isolated Sepic rectifier, and a classical resonant Half-Bridge inverter. The new isolated Sepic rectifier is obtained from a Zero-Current-Switching (ZCS) Pulse-Width-Modulated (PWM) soft-commutation cell. The average-current control technique is used in this preregulator stage in order to provide low phase displacement and low Total-Harmonic-Distortion (THD) at input current, resulting in high power-factor, and attending properly IEC 61000-3-2 standards. The resonant Half-Bridge inverter performs Zero-Voltage-Switching (ZVS), providing conditions for the obtaining of overall high efficiency. It is developed a design example for the new isolated electronic ballast rated at 200W output power, 220Vrms input voltage, 115Vdc dc link voltage, with rectifier and inverter stages operating at 50kHz. Finally, experimental results are presented in order to verify the developed analysis. The THD at input current is equal to 5.25%, for an input voltage THD equal to 1.63%, and the measured overall efficiency is about 88.25%, at rated load.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new topology for a LVLP variable-gain CMOS amplifier is presented. Input- and load-stage are built around triode-transconductors so that voltage-gain is fully defined by a linear relationship involving only device-geometries and biases. Excellent gain-accuracy, temperature-insensitivity; and wide range of programmability, are thus achieved. Moreover, adaptative biasing improves the common-mode voltage stability upon gain-adjusting. As an example, a 0-40dB programmablegain audio-amplifier is designed. Its performance is supported by a range of simulations. For VDD=1.8V and 20dB-nominal gain, one has Av=19.97dB, f3db=770KHz and quiescent dissipation of 378μW. Over temperatures from -25°C to 125°C, the 0. ldB-bandwidth is 52KHz. Dynamic-range is optimized to 57.2dB and 42.6dB for gains of 20dB and 40dB, respectively. THD figures correspond to -60.6dB@Vout= 1Vpp and -79.7dB@Vout= 0.5 Vpp. A nearly constant bandwidth for different gains is also attained.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work proposes a new isolated high power factor 12kW power supply based on an 18-pulse transformer arrangement. Three full-bridge converters are used for isolation and to balance the DC-link currents, without current sensing or a current controller. The topology provides a regulated DC output with a very simple control strategy. Simulation and experimental results are presented in this paper.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple constant-current electrocutaneous stimulator for high-impedance loads using low-cost, standard high-voltage components is presented. A voltage-regulator powers an oscillator built across the primary of a transformer whose secondary delivers, after rectification, the high-voltage supply to switched current-mirrors in the driving stage. Since the compliance high-voltage is proportional to the stimulation current, overall power consumption is minimized. By adjusting the regulated voltage, control of the pulsed-current amplitude is achieved. A prototype with readily available components features stimulation currents of amplitude and pulsewidth in the range 0≤Iskin≤20mA and 50μs ≤Tpulse≤1ms, respectively. Pulse-repetition spans from 1 Hz to 10Hz. Worst-case ripple is 3.7% @Iskin=1mA. Measured pulse fall-time is shorter than 32μs. Overall consumption is 4.4W @Iskin=20mA. Subject isolation from line is 4KV.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An overview is given on the possibility of controlling the status of circuit breakers (CB) in a substations with the use of a knowledge base that relates some of the operation magnitudes, mixing status variables with time variables and fuzzy sets. It is shown that even when all the magnitudes to be controlled cannot be included in the analysis, it is possible to control the desired status while supervising some important magnitudes as the voltage, power factor, and harmonic distortion, as well as the present status.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a high efficiency Sepic rectifier for an electronic ballast application with multiple fluorescent lamps. The proposed Sepic rectifier is based on a Zero-Current-Switching (ZCS) Pulse-Width-Modulated (PWM) soft-commutation cell. The high power-factor of this structure is obtained using the instantaneous average-current control technique, in order to attend properly IEC61000-3-2 standards. The inverting stage of this new electronic ballast is a classical Zero-Voltage-Switching (ZVS) Half-Bridge inverter. A proper design methodology is developed for this new electronic ballast, and a design example is presented for an application with five fluorescent lamps 40W-T12 (200W output power), 220Vrms input voltage, 130Vdc dc link voltage, with rectifier and inverter stages operating at 50kHz. Experimental results are also presented. The THD at input current is equal to 6.41%, for an input voltage THD equal to 2.14%, and the measured overall efficiency is about 92.8%, at rated load.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An active leakage-injection scheme (ALIS) for low-voltage (LV) high-density (HD) SRAMs is presented. By means of a feedback loop comprising a servo-amplifier and a common-drain MOSFET, a current matching the respective bit-line leakage is injected onto the line during precharge and sensing, preventing the respective capacitances from erroneous discharges. The technique is able to handle leakages up to hundreds of μA at high operating temperatures. Since no additional timing is required, read-out operations are performed at no speed penalty. A simplified 256×1bit array was designed in accordance with a 0.35 CMOS process and 1.2V-supply. A range of PSPICE simulation attests the efficacy of ALIS. With an extra power consumption of 242 μW, a 200 μA-leakage @125°C, corresponding to 13.6 times the cell current, is compensated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The nonlinear dynamic response and a nonlinear control method of a particular portal frame foundation for an unbalanced rotating machine with limited power (non-ideal motor) are examined. Numerical simulations are performed for a set of control parameters (depending on the voltage of the motor) related to the static and dynamic characteristics of the motor. The interaction of the structure with the excitation source may lead to the occurrence of interesting phenomena during the forward passage through the several resonance states of the systems. A mathematical model having two degrees of freedom simplifies the non-ideal system. The study of controlling steady-state vibrations of the non-ideal system is based on the saturation phenomenon due to internal resonance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The study of algorithms for active vibrations control in flexible structures became an area of enormous interest, mainly due to the countless demands of an optimal performance of mechanical systems as aircraft and aerospace structures. Smart structures, formed by a structure base, coupled with piezoelectric actuators and sensor are capable to guarantee the conditions demanded through the application of several types of controllers. This article shows some steps that should be followed in the design of a smart structure. It is discussed: the optimal placement of actuators, the model reduction and the controller design through techniques involving linear matrix inequalities (LMI). It is considered as constraints in LMI: the decay rate, voltage input limitation in the actuators and bounded output peak (output energy). Two controllers robust to parametric variation are designed: the first one considers the actuator in non-optimal location and the second one the actuator is put in an optimal placement. The performance are compared and discussed. The simulations to illustrate the methodology are made with a cantilever beam with bonded piezoelectric actuators.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of the present research was to evaluate the effect of plant growth regulators in biomass production and essential oil yield content in lemongrass (Cymbopogon citratus (DC.) Stapf), in different seasons. The experiment was conducted on São Manuel Experimental Farm, Faculdade de Ciências Agronômicas, UNESP - Botucatu. Which plants were randomly assigned into blocks to treatments with three repetitions. The treatments consisted of GA3 (50 and 100 mg L-1); Ethrel (100 and 200 mg L-1); CCC (500 and 1000 mg L-1); Alar 85 (1000 and 2000 mg L-1); Accel (20 and 40 mg 0L-1) and control. Four applications of plant growth regulators were realized every three months. After 40 days of each foliar spray, the plants were cut to determine the fresh weight and essential oil yield. The application of plant growth regulators did not increase the biomass production, showing difference among collect periods when the major production was detected at the fourth collect (summer). The greatest essential oil yield was found at the second collect (winter). In the present study, the used concentrations of plant growth regulators did not increase biomass neither essential oil yield.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Isotope screening is a simple and cheap test for determining the photosynthetic pathway used by plants. The scope of this work was to classify the photosynthetic type of Melissa officinalis L. and Cymbopogon citratus [DC.] Stapf, through studies of the carbon isotope composition (δ13 C), and we are proposing the use of carbon isotope composition results as a tool to control the quality of medicinal plants. For studies of δ 13C (13 C% = [R (sample)/R (standard) - 1] × 10 -3), dried, powdered leaves were analyzed in a mass spectrometer coupled with an elemental analyzer for determining the ratio R (R = 13CO2/12CO2). As results, M. officinalis presented a C3 photosynthetic type, and C. citratus presented a C4 photosynthetic type. The carbon isotope composition from this study can be used as quality control of M. officinalis adulterants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents necessary and sufficient conditions for the following problem: given a linear time invariant plant G(s) = N(s)D(s)-1 = C(sI - A]-1B, with m inputs, p outputs, p > m, rank(C) = p, rank(B) = rank(CB) = m, £nd a tandem dynamic controller Gc(s) = D c(s)-1Nc(s) = Cc(sI - A c)-1Bc + Dc, with p inputs and m outputs and a constant output feedback matrix Ko ε ℝm×p such that the feedback system is Strictly Positive Real (SPR). It is shown that this problem has solution if and only if all transmission zeros of the plant have negative real parts. When there exists solution, the proposed method firstly obtains Gc(s) in order to all transmission zeros of Gc(s)G(s) present negative real parts and then Ko is found as the solution of some Linear Matrix Inequalities (LMIs). Then, taking into account this result, a new LMI based design for output Variable Structure Control (VSC) of uncertain dynamic plants is presented. The method can consider the following design specifications: matched disturbances or nonlinearities of the plant, output constraints, decay rate and matched and nonmatched plant uncertainties. © 2006 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study, the antiulcerogenic effect of essential oil from Baccharis dracunculifolia was evaluated using the model of acute gastric lesions induced by ethanol. The ulcerative lesion index (ULI) was significantly reduced by oral administration of the essential oil of B. dracunculifolia at doses of 50, 250 and 500 mg/kg which reduced the lesions by 42.79, 45.70 and 61.61%, respectively. The analysis of the chemical composition of the essential oil from B. dracunculifolia by GC showed that this was composed mainly of mono- and sesquiterpenes and the majority compound was nerolidol. Therefore, antiulcerogenic activity of nerolidol (50, 250 and 500 mg/kg) was investigated using ethanol-, indomethacin- and stress-induced ulcer models in rat. In the stress-induced ulcer model, a significant reduction of the ULI in animals treated with nerolidol (50, 250 and 500 mg/kg) and cimetidine (100 mg/kg) was observed, compared to the control group (p < 0.05). The percentage of inhibition of ulcer was 41.22, 51.31, 56.57 and 53.50% in groups treated with 50, 250, 500 mg/kg of nerolidol and 100 mg/kg of cimetidine (positive control), respectively. Regarding ethanol- and indomethacin-induced ulcer models, it was observed that the treatment with nerolidol (250 and 500 mg/kg) significantly reduced the ULI in comparison with the control group (p < 0.05). The dose of 50 mg/kg reduced the parameters analyzed but this was not statistically significant. In the ethanol-induced model percentage of inhibition of ulcer was 34.20, 52.63, 87.63 and 50.87% in groups treated with 50, 250, 500 mg/kg of nerolidol and 30 mg/kg of omeprazol (positive control), respectively. In indomethacin-ulcer the percentage of inhibition of ulcer was 34.69, 40.80, 51.02 and 46.93% in groups treated with 50, 250, 500 mg/kg of nerolidol and 100 mg/kg of cimetidine (positive control), respectively. The results of this study show that nerolidol displays antiulcer activity, as it significantly inhibited the formation of ulcers induced in different animal models. However, further pharmacological and toxicological investigations, to delineate the mechanism(s) of action and the toxic effects, are required to allow the use of nerolidol for the treatment of gastric ulcer. © 2007 Verlag der Zeitschrift für Naturforschung.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An analog circuit that implements a radial basis function network is presented. The proposed circuit allows the adjustment of all shape parameters of the radial functions, i.e., amplitude, center and width. The implemented network was applied to the linearization of a nonlinear circuit, a voltage controlled oscillator (VCO). This application can be classified as an open-loop control in which the network plays the role of the controller. Experimental results have proved the linearization capability of the proposed circuit. Its performance can be improved by using a network with more basis functions. Copyright 2007 ACM.