940 resultados para Corneal transplant


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Objective: Medication non-compliance is a considerable obstacle in achievinga therapeutic goal, whichcan result in poorerhealthcare outcomes, increased expenditure, wastage and potential for medication resistance. The UK Government’s Audit Commission’s publication ‘A Spoonful of Sugar’1 addresses these issues and promotes self-medication systems as a possible solution. The self-medication system within the Liver Transplant Unit (LTU) was implemented to induct patients onto new post- transplantation medication regimes ready for discharge. The system involves initial consultations with both the Liver Transplant Pharmacist and Trans- plant Co-ordinator, supported with additional advice as and when necessary. Design: Following ethical approval, evaluation of the self-medication sys- tem for liver transplant patients was conducted between January and March 2004 via two methods: audit and structured post-transplantation interview. The audit enabled any discrepancies between current Hospital guidelines and Liver Transplant Unit (LTU) practices to be highlighted. Patient interviews generated a retrospective insight into patient acceptance of the self-medication system. Setting: LTU, Queen Elizabeth Hospital, Birmingham, England. Main Outcome Measures: LTU compliance with Hospital self-medication guidelines and patient insight into self-medication system. Results: A total of seven patients were audited. Findings illustrated that self- medication by transplant patients is a complex process which was not fully addressed by current Hospital self-medication guidelines. Twenty-three patients were interviewed, showing an overwhelming positive attitude to- wards participating in their own care and a high level of understanding towards their individual medication regimes. Following a drugs counselling session, 100% of patients understood why they were taking their medica- tion, and their doses, 95% understood how to take their medication and 85% were aware of potential side effects. Conclusions: From this pilot evaluation it can be stated that the LTU self-medication system is appreciated by patients and assists them in fully understanding their medication regimes. There appear to be no major defects in the system. However areas such as communication barriers and on-going internet education were illustrated as areas for possible future investigation. References: 1. Audit Commission. A spoonful of sugar – medicines management in NHS hospitals. London: Audit Commission; 2001.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate distance and near image quality after hybrid bi-aspheric multifocal central presbyLASIK treatments. Design: Consecutive case series. Methods: Sixty-four eyes of 32 patients consecutively treated with central presbyLASIK were assessed. The mean age of the patients was 51 ± 3 years with a mean spherical equivalent refraction of-1.08 ± 2.62 diopters (D) and mean astigmatism of 0.52 ± 0.42 D. Monocular corrected distance visual acuity (CDVA), corrected near visual acuity (CNVA), and distance corrected near visual acuity (DCNVA) of nondominant eyes; binocular uncorrected distance visual acuity (UDVA); uncorrected intermediate visual acuity (UIVA); distance corrected intermediate visual acuity (DCIVA); and uncorrected near visual acuity (UNVA) were assessed pre- and postoperatively. Subjective quality of vision and near vision was assessed using the 10-item Rasch-scaled Quality of Vision and Near Activity Visual Questionnaire, respectively. Results: At 1 year postoperatively, 93% of patients achieved 20/20 or better binocular UDVA; 90% and 97% of patients had J2 or better UNVA and UIVA, respectively; 7% lost 2 Snellen lines of CDVA; Strehl ratio reduced by ~-4% ± 14%. Defocus curves revealed a loss of half a Snellen line at best focus, with no change for intermediate vergence (-1.25 D) and a mean gain of 2 lines for near vergence (-3 D). Conclusions: Presbyopic treatment using a hybrid bi-aspheric micro-monovision ablation profile is safe and efficacious. The postoperative outcomes indicate improvements in binocular vision at far, intermediate, and near distances with improved contrast sensitivity. A 19% retreatment rate should be considered to increase satisfaction levels, besides a 3% reversal rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The treatment of presbyopia has been the focus of much scientific and clinical research over recent years, not least due to an increasingly aging population but also the desire for spectacle independence. Many lens and nonlens-based approaches have been investigated, and with advances in biomaterials and improved surgical methods, removable corneal inlays have been developed. One such development is the KAMRA™ inlay where a small entrance pupil is exploited to create a pinhole-type effect that increases the depth of focus and enables improvement in near visual acuity. Short- and long-term clinical studies have all reported significant improvement in near and intermediate vision compared to preoperative measures following monocular implantation (nondominant eye), with a large proportion of patients achieving Jaeger (J) 2 to J1 (~0.00 logMAR to ~0.10 logMAR) at the final follow-up. Although distance acuity is reduced slightly in the treated eye, binocular visual acuity and function remain very good (mean 0.10 logMAR or better). The safety of the inlay is well established and easily removable, and although some patients have developed corneal changes, these are clinically insignificant and the incidence appears to reduce markedly with advancements in KAMRA design, implantation technique, and femtosecond laser technology. This review aims to summarize the currently published peer-reviewed studies on the safety and efficacy of the KAMRA inlay and discusses the surgical and clinical outcomes with respect to the patient’s visual function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interaction of the wound dressing as a biomaterial with the wound bed is the central issue of this chapter. The interfacial phenomenon that encompasses the biological and biochemical consequences that arise when a biomaterial is introduced to a host biological environment is discussed. A great deal can be learned from observations arising from the behaviour of biomaterials at other body sites; one particularly relevant body site in the context of wound healing is the anterior eye. The cornea, tear film and posterior surface of the contact lens provide an informative model of the parallel interface that exists between the chronic wound bed, wound fluid and the dressing biomaterial. © 2011 Woodhead Publishing Limited All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the correlation between changes in corneal aberrations and the 2-year change in axial length in children fitted with orthokeratology (OK) contact lenses. METHODS: Thirty-one subjects 6 to 12 years of age and with myopia −0.75 to −4.00DS and astigmatism ≤1.00DC were fitted with OK. Measurements of axial length and corneal topography were taken at regular intervals over a 2-year period. Corneal topography at baseline and after 3 and 24 months of OK lens wear was used to derive higher-order corneal aberrations (HOA) that were correlated with OK-induced axial length changes at 2 years. RESULTS: Significant changes in C3, C4, C4, root mean square (RMS) secondary astigmatism and fourth and total HOA were found with both 3 and 24 months of OK lens wear in comparison with baseline (all P0.05). Coma angle of orientation changed significantly pre-OK in comparison with 3 and 24 months post-OK as well as secondary astigmatism angle of orientation pre-OK in comparison with 24 months post-OK (all P0.05). DISCUSSION: Short-term and long-term OK lens wear induces significant changes in corneal aberrations that are not significantly correlated with changes in axial elongation after 2-years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Treatment of sensory neuropathies, whether inherited or caused by trauma, the progress of diabetes, or other disease states, are among the most difficult problems in modern clinical practice. Cell therapy to release antinociceptive agents near the injured spinal cord would be the logical next step in the development of treatment modalities. But few clinical trials, especially for chronic pain, have tested the transplant of cells or a cell line to treat human disease. The history of the research and development of useful cell-transplant-based approaches offers an understanding of the advantages and problems associated with these technologies, but as an adjuvant or replacement for current pharmacological treatments, cell therapy is a likely near future clinical tool for improved health care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Effective treatment of sensory neuropathies in peripheral neuropathies and spinal cord injury (SCI) is one of the most difficult problems in modern clinical practice. Cell therapy to release antinociceptive agents near the injured spinal cord is a logical next step in the development of treatment modalities. But few clinical trials, especially for chronic pain, have tested the potential of transplant of cells to treat chronic pain. Cell lines derived from the human neuronal NT2 cell line parentage, the hNT2.17 and hNT2.19 lines, which synthesize and release the neurotransmitters gamma-aminobutyric acid (GABA) and serotonin (5HT), respectively, have been used to evaluate the potential of cell-based release of antinociceptive agents near the lumbar dorsal (horn) spinal sensory cell centers to relieve neuropathic pain after PNS (partial nerve and diabetes-related injury) and CNS (spinal cord injury) damage in rat models. Both cell lines transplants potently and permanently reverse behavioral hypersensitivity without inducing tumors or other complications after grafting. Functioning as cellular minipumps for antinociception, human neuronal precursors, like these NT2-derived cell lines, would likely provide a useful adjuvant or replacement for current pharmacological treatments for neuropathic pain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ocean acidification (OA) is likely to exert selective pressure on natural populations. Our ability to predict which marine species will adapt to OA, and what underlies this adaptive potential, are of high conservation and resource management priority. Using a naturally low pH vent site in the Mediterranean Sea (Castello Aragonese, Ischia) mirroring projected future OA conditions, we carried out a reciprocal transplant experiment to investigate the relative importance of phenotypic plasticity and local adaptation in two populations of the sessile, calcifying polychaete /Simplaria /sp. (Annelida, Serpulidae, Spirorbinae): one residing in low pH and the other from a nearby ambient (i.e. high) pH site. We measured a suite of fitness related traits (i.e. survival, reproductive output, maturation, population growth) and tube growth rates in laboratory-bred F2 generation individuals from both populations reciprocally transplanted back into both ambient and low pH /in situ/ habitats. Both populations showed lower expression in all traits, but increased tube growth rates, when exposed to low pH compared to high pH conditions, regardless of their site of origin suggesting that local adaptation to low pH conditions has not occurred. We also found comparable levels of plasticity in the two populations investigated, suggesting no influence of long-term exposure to low pH on the ability of populations to adjust their phenotype. Despite high variation in trait values among sites and the relatively extreme conditions at sites close to the vents (pH < 7.36), response trends were consistent across traits. Hence, our data suggest that, for /Simplaria /and possibly other calcifiers, neither local adaptations nor sufficient phenotypic plasticity levels appear to suffice in order to compensate for the negative impacts of OA on long-term survival. Our work also underlines the utility of field experiments in natural environments subjected to high level of /p/CO_2 for elucidating the potential for adaptation to future scenarios of OA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to characterize in a clinical and epidemiological way the patients who are on a waiting list for transplantation and the patients transplanted with corneal tissue in a corneal transplants reference service in the state of Rio Grande do Norte. It is an epidemiological study of a quantitative approach, with cross-sectional, descriptive and analytical cut including all patients on the waiting list for transplantation (population A) and the patients already transplanted with a corneal tissue (population B) in a reference service. In population A, there was a census conducted of patients on the waiting list for corneal transplantation (n=62 patients). In population B, the sample was non-probabilistic and corresponded to all corneal transplants performed in the service in the period from 2010 to 2014 (n=258). This study is approved by the Research Ethics Committee of the Federal University of Rio Grande do Norte, in Opinion 876 177 and CAAE 37533014.8.0000.5537. Data were collected in full in the period from January to April 2015, by two instruments built to systematize the necessary data collection. After being coded and tabulated, data were analyzed using the Statistical Package for Social Sciences software, version 20.0. The definition of variables and their distribution patterns were presented as frequencies and measures of central tendency while, for multivariate analysis, the effect of magnitude measures were applied (prevalence ratio) and measures of association (chi-square test or Fisher's exact test) for a 0.05 significance level. The results are shown in two scientific articles coming from the field survey data. It was found that the epidemiological profile of patients on the waiting list (n=62) showed a prevalence of individuals aged over 50 years old, female (54.84%) and residents of the middle region of East Rio Grande do Norte (66.13%). The clinical profile of patients with corneal transplantation (n=258) was characterized by being male (51.16%) with an average age of 49.33 years old and 57.75% were coming from East Rio Grande do Norte. The average time on the waiting list was 172.63 days in elective transplants and 9.03 days in urgent transplants. Keratoconus was the main indicator condition to perform the transplant. For patients on the waiting list, the variable “type of disorder of the cornea” showed statistically significant association with gender and age. For patients with corneal transplants, the variable "type of disorder of the cornea" was associated with the variables gender, age, previous surgery, failure of previous graft, classification of the eye and glaucoma. By characterizing the clinical and epidemiological profile of corneal transplants, it is possible to question the reality, pointing about the care that should be offered and develop targeted interventions to collective and individual needs intrinsic to patients who need this surgery as a treatment option.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El Ap4A es una molécula con un amplio papel biológico en el ojo. Se ha descrito su implicación en procesos de secreción lagrimal, cicatrización epitelial, regulación de la presión intraocular, y presenta también un papel neuroprotector sobre los terminales simpáticos que inervan el cuerpo ciliar. El objetivo de este trabajo ha sido analizar la participación del Ap4A en otras posibles funciones a nivel ocular. En concreto se ha estudiado la capacidad de este dinucléotido para estimular la liberación de proteínas lagrimales de acción antibacteriana tales como la lisozima y la lactoferrina. Por otra parte se ha investigado su efecto como modulador de la función de barrera de la córnea a través de la regulación de los niveles de expresión de proteínas constituyentes de las tight junctions (TJ). Dicho efecto sobre la barrera puede tener una importante repercusión en la entrada de fármacos y en la consiguiente eficacia terapéutica de los mismos. Por último, se ha estudiado la posible implicación del dinucleótido en el proceso de edematización descrito en modelos animales glaucomatosos tales como el ratón DBA/2J. Con el objetivo de averiguar si la activación de Ap4A inducía un efecto sobre la producción de dos proteínas antimicrobianas relevantes de la lágrima (lisozima y lactoferrina) se realizaron ensayos en la lágrima de conejos albinos de Nueva Zelanda, mediante las técnicas de agar-agar y ELISA. Los resultados obtenidos demostraron que Ap4A produce un aumento en la concentración de lisozima y de lactoferrina del 93% y 24%, respectivamente, frente a valores basales, y este efecto está mediado por receptores de tipo P2...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La citología de impresión corneal es una técnica atraumática, simple, rápida y carente de efectos secundarios que permite estudiar las capas celulares más externas de la superficie ocular, posibilitando el diagnóstico de enfermedades de la misma y su monitorización durante y después del tratamiento. Los objetivos de la presente Tesis Doctoral han sido normalizar la técnica de obtención y procesamiento de muestras obtenidas por citología de impresión corneal en la especie canina, determinar los parámetros morfológicos y morfométricos fisiológicos de las células epiteliales corneales en perros sanos y establecer las alteraciones celulares corneales en el transcurso de la QCS canina. Además, se ha estudiado la existencia de una correlación entre las alteraciones del epitelio corneal y la producción lagrimal valorada mediante la prueba lagrimal de Schirmer I (PLS I). En este estudio se han incluido 60 perros de diferentes razas que han sido divididos en dos poblaciones: el grupo I, formado por pacientes sanos, con unos valores en la prueba lagrimal de Schirmer I (PLS I) iguales o superiores a 15 mm/min y el grupo II, formado por pacientes diagnosticados de QCS con unos valores en la PLS I comprendidos entre 0 y 14 mm/min. Los ojos de los animales del grupo II han sido categorizados a su vez en 3 subgrupos, estableciendo la gravedad de la enfermedad en función de los resultados obtenidos en la PLS I como grave, moderada o leve. Para facilitar la recogida y el manejo de las muestras, adecuar la técnica para su empleo en animales y disminuir al mínimo cualquier tipo de lesión iatrogénica sobre la superficie ocular se ha utilizado un dispositivo simple y eficaz, diferente a los que se han venido empleando tradicionalmente en oftalmología humana y veterinaria. La valoración morfométrica de las células se ha realizado atendiendo a los criterios de celularidad de la muestra, separación intercelular, morfología de las células, tinción citoplasmática, área celular, área nuclear, ratio núcleo/citoplasma (ratio N:C) y alteraciones nucleares...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We thank Darrin Sheppard and other staff at the University of Aberdeen Medical Research Facility for specialist technical assistance. We thank Patsy D. Goast for overnight microscope monitoring. This work was performed under the Biotechnology and Bioscience Research Council Grant number BB/E015840/1 to JMC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.