993 resultados para Composite resins - Dental leakage


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The indications for direct resin composite restorations are nowadays extended due to the development of modern resin materials with improved material properties. However, there are still some difficulties regarding handling of resin composite material, especially in large restorations. The reconstruction of a functional and individual occlusion is difficult to achieve with direct application techniques. The aim of the present publication was to introduce a new "stamp"-technique for placing large composite restorations. The procedure of this "stamp"-technique is presented by three typical indications: large single-tooth restoration, occlusal rehabilitation of a compromised occlusal surface due to erosions and direct fibre-reinforced fixed partial denture. A step-by-step description of the technique and clinical figures illustrates the method. Large single-tooth restorations can be built-up with individual, two- piece silicone stamps. Large occlusal abrasive and/or erosive defects can be restored by copying the wax-up from the dental technician using the "stamp"-technique. Even fiber-reinforced resin-bonded fixed partial dentures can be formed with this intraoral technique with more precision and within a shorter treatment time. The presented "stamp"-technique facilitates the placement of large restoration with composite and can be recommended for the clinical use.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Reimbursement for dental services performed for children receiving Medicaid is reimbursed per service while dental treatment for military dependents provided at a military installation is neither directly reimbursable to those providing the care nor billed to those receiving the care. The purpose of this study was to compare pediatric dental services provided for a Medicaid population to a federally subsidized military facility to compare treatment choices and subsequent costs of care. It was hypothesized that differences in dental procedures for Medicaid and military dependent children would exist based upon treatment philosophy and payment method. A total of 240 records were reviewed for this study, consisting of 120 Medicaid patients at the University of Texas Health Science Center at San Antonio (UTHSCSA) and 120 military dependents at Wilford Hall Medical Center (WHMC), Lackland Air Force Base, San Antonio. Demographic data and treatment information were abstracted for children receiving dental treatment under general anesthesia between 2002 and 2006. Data was analyzed using the Wilcoxon rank sum test, Kruskal-Wallis test, and Fisher's exact test. The Medicaid recipients treated at UTHSCSA were younger than patients at WHMC (40.2 vs. 49.8 months, p<.001). The university also treated significantly more Hispanic children than WHMC (78.3% vs. 30.0%, p<.001). Children at UTHSCSA had a mean of 9.5 decayed teeth and were treated with 2.3 composite fillings, 0 amalgam fillings, 5.6 stainless steel crowns, 1.1 pulp therapies, 1.6 extractions, and 1.0 sealant. Children at WHMC had a mean of 8.7 decayed teeth and were treated with 1.4 composite fillings, 0.9 amalgam fillings, 5.6 stainless steel crowns, 1.7 pulp therapies, 0.9 extractions, and 2.1 sealants. The means of decayed teeth, total fillings, and stainless steel crowns were not statistically different. UTHSCSA provided more composite fillings (p<.001), fewer amalgam fillings (p<.001), fewer pulp therapies (p <.001), more extractions (p=.01), and fewer sealants (p<.001) when compared to WHMC. Age and gender did not effect decay rates, but those of Hispanic ethnicity did experience more decay than non-Hispanics (9.5 vs. 8.6, p=.02). Based upon Texas Medicaid reimbursement rates from 2006, the cost for dental treatment at both sites was approximately $650 per child. The results of this study do not support the hypothesis that Medicaid providers provide less conservative therapies, which would be more costly, care when compared to a military treatment center. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To assess the indoor environment of two different types of dental practices regarding VOCs, PM2.5, and ultrafine particulate concentrations and examine the relationship between specific dental activities and contaminant levels. Method: The indoor environments of two selected dental settings (private practice and community health center) will were assessed in regards to VOCs, PM 2.5, and ultrafine particulate concentrations, as well as other indoor air quality parameters (CO2, CO, temperature, and relative humidity). The sampling duration was four working days for each dental practice. Continuous monitoring and integrated sampling methods were used and number of occupants, frequency, type, and duration of dental procedures or activities recorded. Measurements were compared to indoor air quality standards and guidelines. Results: The private practice had higher CO2, CO, and most VOC concentrations than the community health center, but the community health center had higher PM2.5 and ultrafine PM concentrations. Concentrations of p-dichlorobenzene and PM2.5 exceeded some guidelines. Outdoor concentrations greatly influenced the indoor concentration. There were no significant differences in contaminant levels between the operatory and general area. Indoor concentrations during the working period were not always consistently higher than during the nonworking period. Peaks in particulate matter concentration occurred during root canal and composite procedures.^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O presente trabalho teve por foco prover uma revisão de conceitos relacionados às resinas dentais fotopolimeráveis e, também, analisar como diferentes concentrações de fotoiniciadores de uso comum em odontologia podem influenciar no desempenho mecânico e na cor de resinas dentais. Concentrações de 0,01%, 0,10%, 0,25% 0,50%, 0,75%, 1,00% e 10% em massa de fotoiniciador foram adicionadas em uma matriz polimérica composta por TEGDMA/BisGMA 50%/50% em massa de forma que, fixando variáveis externas referentes à fonte de luz e à preparação das amostras, foi possível avaliar o efeito da concentração de fotoiniciador nas propriedades mecânicas de resistência à fratura por compressão, resistência à fratura pela aplicação de tensão diametral e dureza Barcol. Por fim, o efeito da concentração na cor aferida através do método CIELab foi investigada. Os fotoiniciadores utilizados foram o Irgacure® 819, a 1-fenil-1,2-propanodiona (PPD) e a Canforoquinona a qual foi utilizada juntamente com ocoiniciador Etil-4 dimetilaminobenzoato (EDB) na concentração constante de 1% em massa. Os resultados mecânicos e de cor foram comparados entre as diferentes amostras através de análises estatísticas (ANOVA) e, especificamente para cor, o parâmetro de diferença de cor (ΔE) foi interpretado verificar se as alterações observadas são perceptíveis ao olho humano. Para fundamentar os estudos, análises do espectro de absorção das amostras, do espectro de irradiação da fonte de luz e do grau de conversão das amostras foram realizadas. Os resultados revelaram que, independentemente do fotoiniciador, graus de conversão da mesma ordem de grandeza de um adesivo comercial foram obtidos, porém as velocidades de reação foram diferentes (maior velocidade para as amostras de CQ e menor para PPD). Curvas características foram obtidas para os espectros de absorção e de irradiação confirmando, pela sobreposição das curvas, que a fonte de luz é efetiva para iniciação da polimerização das amostras. As análises de resistência à fratura revelaram que a quebra catastrófica do material ocorrerá preferencialmente quando a força é aplicada ao longo do diâmetro para os corpos de prova preparados. Quanto à dureza, verificou-se que que para a CQ houve um máximo, para Irgacure um comportamento assintótico com aumento da concentração e, para a PPD, não foi possível a obtenção de amostras (verificado que a PPD necessita de tempo de irradiação superior ao convencionalmente utilizado na prática odontológica). Os testes de ANOVA permitiram verificar que o Irgacure é capaz de fornecer resultados mecânicos semelhante em relação à CQ ocasionando, em contrapartida, um menor escurecimento e amarelamento. Analisando o parâmetro ΔE, confirmou-se que a alteração na cor se torna evidente à medida que ocorre o aumento da concentração de fotoiniciador independentemente do fotoiniciador utilizado, porém a alteração é maior para a CQ.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dental implant is used to replace the natural dental root. The process to fix the dental implant in the maxillary bone needs a previous drilling operation. This machining operation involves the increasing of temperature in the drilled region which can reach values higher than 47°C and for this temperature is possible to occur the osseous necrosis [I]. The main goal of this work is to implement an optimization method to define the optimal drilling parameters that could minimize the drilling temperature. The proposal optimization method is the Taguchi method. This method has been used with success in machining processes optimization of metallic materials [2]. However, the Taguchi method is also used in medical applications, namely in dental medicine [3].

Relevância:

30.00% 30.00%

Publicador:

Resumo:

[composite with images cropped from team photos, 1898 alumni team photo and a ca. 1940 photo of former Prettyman's Boarding House, on site of Dental School]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives. This study examined the depth of cure and surface microhardness of Filtek Z250 composite resin (3M-Espe) (shades B1, A3, and C4) when cured with three commercially available tight emitting diode (LED) curing lights [E-light (GC), Elipar Freelight (3M-ESPE), 475H (RF Lab Systems)], compared with a high intensity quartz tungsten halogen (HQTH) light (Kerr Demetron Optilux 501) and a conventional quartz tungsten halogen (QTH) lamp (Sirona S1 dental unit). Methods. The effects of light source and resin shade were evaluated as independent variables. Depth of cure after 40 s of exposure was determined using the ISO 4049:2000 method, and Vickers hardness determined at 1.0 mm intervals. Results. HQTH and QTH lamps gave the greatest depth of cure. The three LED lights showed similar performances across all parameters, and each unit exceeded the ISO standard for depth of cure except GC ELight for shade B1. In terms of shade, LED lights gave greater curing depths with A3 shade, while QTH and HQTH tights gave greater curing depths with C4 shade. Hardness at the resin surface was not significantly different between LED and conventional curing lights, however, below the surface, hardness reduced more rapidly for the LED lights, especially at depths beyond 3 mm. Significance. Since the performance of the three LED lights meets the ISO standard for depth of cure, these systems appear suitable for routine clinical application for resin curing. (C) 2003 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The interaction of microorganisms with glass-reinforced polyester resins(GRP), both under laboratory and simulated operating conditions, has been examined following reports of severl! fungal biodeterioration. Although GRP was not previously associated with substantial microbial growth, small amounts of microbial activity would pose problems for products associated with comestible materials. The microbiology of the raw materials was investigated, two ingredients were supportive to microbial populations whilst five materials were biostatic or inhibitory in their action. Production laminate was not susceptible to microbial deterioration or inhibitory to microbes. Incorporation of zinc stearate, one of the supportive ingredients, at 300% manufacturing level or drastic undercuring produced laminate capable of supporting microbial growth but only after a non-biotic stage of degradation. Study of the long-term population dynamics of cisterns of GRP and competitive materials under conditions simulating in-service conditions, monitoring microbial numbers within the experimental vessels and comparing with the populations of the supply water, suggests that the performance of GRP cisterns is slightly superior to conventional competitive materials. An investigation of the biological performance of GRP cisterns in an isolated area of known microbiological hazard was conducted. Severe biodeterioration had been experienced with Preform GRP articles moulded using different production techniques, but substitution of current GRP articles resulted in no recurrence of the problem. All attempts to establish the fungal isolate responsible for the phenomena in cisterns under controlled conditions failed. Scanning Electron Microscopy of GRP surfaces showed that although differences exist between current and Preform laminates, these could not satisfactorily explain the differences in service behaviour. These results and the results of the British Plastics Federation Expert Working Group interlaboratory study are discussed in relation to the original report of gross fungal biodeterioration and, to the design of future testing programmes for the products of industrial concerns.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Synthetic calcium phosphates, despite their bioactivity, are brittle. Calcium phosphate-mullite composites have been suggested as potential dental and bone replacement materials which exhibit increased toughness. Aluminium, present in mullite, has however been linked to bone demineralisation and neurotoxicity: it is therefore important to characterise the materials fully in order to understand their in vivo behaviour. The present work reports the compositional mapping of the interfacial region of a calcium phosphate-20 wt% mullite biocomposite/soft tissue interface, obtained from the samples implanted into the long bones of healthy rabbits according to standard protocols (ISO-10993) for up to 12 weeks. X-ray micro-fluorescence was used to map simultaneously the distribution of Al, P, Si and Ca across the ceramic-soft tissue interface. A well defined and sharp interface region was present between the ceramic and the surrounding soft tissue for each time period examined. The concentration of Al in the surrounding tissue was found to fall by two orders of magnitude, to the background level, within similar to 35 mu m of the implanted ceramic.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Materiais compósitos restauradores representam um dos mais bem sucedidos biomateriais na pesquisa moderna, na substituição do tecido biológico em aparência e função. Nesta linha, a porcelana feldspática tem sido largamente usada em odontologia devido suas interessantes qualidades como estabilidade de cor, propriedades estéticas, elevada durabilidade mecânica, biocompatibilidade, baixa condutividade térmica e elevada resistência ao desgaste. Entretanto, este material é frágil e pode falhar em ambiente oral devido ao micro-vazamento, baixa resistência à tração, descolagem ou fratura. Assim, para melhorar as propriedades mecânicas da porcelana, a zircônia parcialmente estabilizada com Ítria (Y-TZP) pode ser uma boa alternativa para fortalecer e produzir infraestruturas totalmente cerâmicas (coroas e próteses parciais fixas). Portanto, este estudo tem por objetivo avaliar as propriedades mecânicas e características microestruturais da porcelana reforçada com zircônia (3Y-TZP) em diferentes conteúdos e as variáveis que afetam as propriedades mecânicas destes materiais. O estudo de caracterização revelou que a zircônia comercial apresenta melhores resultados quando comparada com a zircônia sintetizada pelo CPM. Assim, os estudos seguintes utilizaram a zircônia comercial para todos os testes requeridos. As partículas de zircônia apresentam elevadas propriedades mecânicas quando comparadas a zircônia aglomerada. Os diferentes conteúdos revelam que as propriedades mecânicas dos compósitos aumentam com o aumento do conteúdo volumétrico até 30% vol.% (198,5Mpa), ou seja, maior resistência à flexão quando comparada com os outros compósitos. Do mesmo modo, a resistência ao desgaste para os compósitos com (30%, vol.% de zircônia) apresenta valores superiores quando comparado aos demais compósitos. Na adesão cerâmico-cerâmico a porcelana exibe elevada adesão para a superfície de zircônia porosa quando comparada a superfície rugosa. Os furos superficiais (PZ) e aplicação de compósitos com camada intermediária (RZI) na zircônia causam separadamente uma melhoria da resistência ao cisalhamento da zircônia-porcelana quando comparados as amostras convencionais de zircônia-porcelana (RZ), embora não sejam estatisticamente significativas (p>0.05). A presença de uma camada intermediaria produz um aumento significativo na força de ligação (~55%) em relação as amostras convencionais (RZ). Portanto, a correta a correta configuração e tratamento superficial podem produzir subestruturas com qualidade e força de ligação adequadas aos requisitos odontológicos.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: To study the outcomes for restored primary molar teeth; to examine outcomes in relation to tooth type involved, intracoronal restoration complexity and to the material used. Materials and methods: Design: Retrospective study of primary molar teeth restored by intracoronal restorations. A series of restored primary molar teeth for children aged 6-12 years was studied. The principal outcome measure was failure of initial restoration (re-restoration or extraction). Three hundred patient records were studied to include three equal groups of primary molar teeth restored with amalgam, composite or glass ionomer, respectively. Restorative materials, the restoration type, simple (single surface) or complex (multi-surface) restoration, and tooth notation were recorded. Subsequent interventions were examined. Data were coded and entered into a Microsoft Excel database and analysis undertaken using SPSS v.18. Statistical differences were tested using the c2 test of statistical significance. Results: Of the 300 teeth studied, 61 restoration failures were recorded with 11 of those extracted. No significant differences were found between outcomes for upper first, upper second, lower first or lower second primary molars. Outcomes for simple primary teeth restored by intracoronal restorations were significantly better than those for complex intracoronal restorations (P = 0.042). Teeth originally restored with amalgam accounted for 19.7% of the 61 failures, composite for 29.5%, while teeth restored with glass ionomer represented 50.8% of all restoration failures. The differences were significant (P = 0.012). Conclusions: The majority (79.7%) of the 300 restored primary teeth studied were successful, and 3.7% teeth were extracted. Restorations involving more than one surface had almost twice the failure rate of single surface restorations. The difference was significant. Significant differences in failure rates for the three dental materials studied were recorded. Amalgam had the lowest failure rate while the failure rate with glass ionomer was the highest.