986 resultados para Colony-Forming Units Assay
Resumo:
Chloride attack in marine environments or in structures where deicing salts are used will not always show profiles with concentrations that decrease from the external surface to the interior of the concrete. Some profiles show an increase in chloride concentrations from when a peak is formed. This type of profile must be analyzed in a different way from the traditional model of Fick`s second law to generate more precise service life models. A model for forecasting the penetration of chloride ions as a function of time for profiles having formed a peak. To confirm the efficiency of this model, it is necessary to observe the behavior of a chloride profile with peak in a specific structure over a period of time. To achieve this, two chloride profiles with different ages (22 and 27 years) were extracted from the same structure. The profile obtained from the 22-year sample was used to estimate the chloride profile at 27 years using three models: a) the traditional model using Fick`s second law and extrapolating the value of C(S)-external surface chloride concentration; b) the traditional model using Fick`s second law and shifting the x-axis to the peak depth; c) the previously proposed model. The results from these models were compared with the actual profile measured in the 27-year sample and the results were analyzed. The model was presented with good precision for this study of case, requiring to be tested with other structures in use.
Resumo:
In petroleum refineries, water is used in desalting units to remove the salt contained in crude oil. Typically, 7% of the volume of hot crude oil is water, forming a water-and-oil emulsion. The emulsion flows between two electrodes and is subjected to an electric field. The electrical forces promote the coalescence of small droplets of water dispersed in crude oil, and these form bigger droplets. This paper calculates the forces acting on the droplets, highlighting particularly the mechanisms proposed for droplet-droplet coalescence under the influence of an applied electric field. Moreover, a model is developed in order to calculate the displacement speed of the droplets and the time between droplet collisions. Thus, it is possible to simulate and optimize the process by changing the operational variables (temperature, electrical field, and water quantity). The main advantage of this study is to show that it is feasible to increase the volume of water recycled in desalting processes, thus reducing the use of freshwater and the generation of liquid effluents in refineries.
Resumo:
BACKGROUND: Guidelines for red blood cell (RBC) transfusions exist; however, transfusion practices vary among centers. This study aimed to analyze transfusion practices and the impact of patients and institutional characteristics on the indications of RBC transfusions in preterm infants. STUDY DESIGN AND METHODS: RBC transfusion practices were investigated in a multicenter prospective cohort of preterm infants with a birth weight of less than 1500 g born at eight public university neonatal intensive care units of the Brazilian Network on Neonatal Research. Variables associated with any RBC transfusions were analyzed by logistic regression analysis. RESULTS: Of 952 very-low-birth-weight infants, 532 (55.9%) received at least one RBC transfusion. The percentages of transfused neonates were 48.9, 54.5, 56.0, 61.2, 56.3, 47.8, 75.4, and 44.7%, respectively, for Centers 1 through 8. The number of transfusions during the first 28 days of life was higher in Center 4 and 7 than in other centers. After 28 days, the number of transfusions decreased, except for Center 7. Multivariate logistic regression analysis showed higher likelihood of transfusion in infants with late onset sepsis (odds ratio [OR], 2.8; 95% confidence interval [CI], 1.8-4.4), intraventricular hemorrhage (OR, 9.4; 95% CI, 3.3-26.8), intubation at birth (OR, 1.7; 95% CI, 1.0-2.8), need for umbilical catheter (OR, 2.4; 95% CI, 1.3-4.4), days on mechanical ventilation (OR, 1.1; 95% CI, 1.0-1.2), oxygen therapy (OR, 1.1; 95% CI, 1.0-1.1), parenteral nutrition (OR, 1.1; 95% CI, 1.0-1.1), and birth center (p < 0.001). CONCLUSIONS: The need of RBC transfusions in very-low-birth-weight preterm infants was associated with clinical conditions and birth center. The distribution of the number of transfusions during hospital stay may be used as a measure of neonatal care quality.
Resumo:
Simulation of irrigated Thanzania grass growth based on photothermal units, nitrogen fertilization and water availability. The mathematical model to predict the forage yield using photothennal units was utilized with success in Elephant grass, Thanzania and Brachiaria niziziensis in the absence of water stress and nitrogen stress. The aim of this study was to propose models to estimate the forage yield of Thanzania grass under different irrigation (25, 50,75, 100 e 125% of ETc) and nitrogen level in various regions of Brazil. As such, models were developed to estimate the dry matter production of Panicum maximum Jacq. frass cv Thanzania in different irrigation and nitrogen levels, using photothermal units. The models were adjusted to doses of 0, 30, 60, 110 and 270 kg of N ha(-1), doses were divided in applications after each evaluation, with a rest cycle of 35 days. The adjusted model presented good performance in predicting dry matter production of Thanzania grass, with r(2) = 0.9999. The results made it possible to verify that the proposed model can be used to predict forage production in different regions of Brazil. It can be estimated, with good precision. The production of Thanzania grass dry matter can be accurately estimated in specific places (in function of latitude and time of year), with the maximum and minimum temperature values.
Resumo:
Objectives: The resazurin microtitre plate assay (REMA) was evaluated to determine the susceptibility of Mycobacterium tuberculosis to pyrazinamide, and was compared with the broth microdilution method (BMM), the absolute concentration method (ACM) and pyrazinamidase (PZase) determination. Methods: Thirty-four M. tuberculosis clinical isolates (26 susceptible and 8 resistant to pyrazinamide) and reference strains M. tuberculosis H37Rv ATCC 27294 and Mycobacterium bovis AN5 were tested. Results: REMA and BMM showed 100% specificity and sensitivity when compared with ACM; BMM, however, demanded more reading time. The PZase determination assay showed 87.50% and 100% sensitivity and specificity, respectively. Conclusions: All tested methods in this preliminary study showed excellent sensitivity and specificity for the determination of pyrazinamide susceptibility of M. tuberculosis, but REMA was faster, low-cost and easy to perform and interpret. Additional studies evaluating REMA for differentiating pyrazinamide-resistant and-susceptible M. tuberculosis should be conducted on an extended panel of clinical isolates.
Resumo:
Block copolymers containing isosorbide succinate and L-lactic acid repeating units with different mass compositions were synthesized in two steps: bulk ring-opening copolymerization from L-lactide and poli(isosorbide succinate) (PIS) preoligomer, in the presence of tin(II) 2-ethylhexanoate as catalyst. followed by chain extension in solution by using hexamethylene diisocyanate. Poly(L-lactide) (PLLA) and a chain extension product from PIS were also obtained, for comparison. SEC, (1)H and (13)C NMR, MALDI-TOFMS, WAXD, DSC, TG, and contact angle measurements were used in their characterization. The incorporation of isosorbide succinate into PLLA main backbone had minor effect on the thermal stability and the T(g) of the products. However, it reduced the crystallinity and increased the surface energy in relation to PLLA. Nonwoven mats of the block copolymers and PLLA obtained by electrospinning technique were submitted to fibroblasts 3T3-L1 cell culture. The copolymers presented enhanced cell adhesion and proliferation rate as revealed by MTT assay and SEM images. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
The objective of this study was to verify the possible inclusion of the Salmonella/microsome mutagenicity assay in a groundwater monitoring program as a complementary assay to assess water quality. Groundwater samples belonging to seven wells from different types of aquifers were analyzed. Three different methods for sample preparation were used: membrane filtration; liquid-liquid and XAD-4 extraction. The filtered samples were tested using TA98, TA100, YG1041 and YG1042 and the water extracts only with TA98 and TA100. No mutagenic activity was observed in any of the 16 filtered samples tested. Out of the 10 samples analyzed using XAD-4 extraction, five showed mutagenic activity with potency ranging from 130 to 1500 revertants/L. Concerning the liquid-liquid extraction, from the 11 samples analyzed, 3 showed mutagenicity. The XAD-4 extraction was the most suitable sample preparation. TA98 without S9 was found to be the most sensitive testing condition. The wells presenting water samples with mutagenic activity belonged to unconfined aquifers, which are more vulnerable to contamination. The data suggest that Salmonella/microsome assay can be used as an efficient screening tool to monitor groundwater for mutagenic activity. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
The aim of this Study was to determine if protein-energy malnutrition Could affect the hematologic response to granulocyte colony-stimulating factor (G-CSF). Swiss mice were fled a low-protein diet containing 4% protein, whereas control mice were fed a 20% protein-containing diet. After the malnourished group lost 20% of their original body weight, the mice were subdivided in 2 treatment groups, and hematopoietic parameters were studied. Mice were injected with either 8 mu g/kg per day of G-CSF or saline twice daily for 4 days. Malnourished mice developed anemia with reticulopenia and leukopenia with depletion of granulocytes and lymphocytes. Both malnourished and control mice treated with G-CSF showed a significant increase in neutrophils; however, in the control group, this increase was more pronounced compared to the malnourished group (4.5-fold and 3.4-fold, respectively). Granulocyte colony-stimulating factor administration increased bone marrow blastic (P < .001) and granulocytic (P < .01) compartments in the controls bill had no significant effect oil these hematopoietic compartments in the Malnourished animals (P = .08 and P = .62, respectively). We report that malnourished mice display an impaired response to G-CSF, which contributes to the decreased production of leukocytes in protein-energy malnutrition. (C) 2008 Elsevier Inc. All rights reserved.
Resumo:
New fast liquid chromatographic and capillary zone electrophoresis methods were developed and validated for simultaneous determination of atenolol and chlortalidone in combined dose tablets. The reversed phase HPLC method was carried out on a CN LiChrosorb (R) (125 x 4 mm, 5 mu m) column. The CZE method was carried out on an uncoated fused-silica capillary of 30 cm x 75 mu m i.d. with 25 mmol L(-1) sodium tetraborate, pH 9.4. The total analysis time was <6 and <2.5 min for HPLC and CZE methods, respectively. Both methods can be used for stability studies as well.
Resumo:
A simple and rapid development of a stability-indicating LC method for determination of chloroquine diphosphate in the presence of its hydrolysis, oxidative and photolysis degradation products is described. Stress testing showed that chloroquine diphosphate was degraded under basic conditions and by photolytic treatment but was stable under the other stress conditions investigated. Separation of the drug from its degradation products was achieved with a Nova Pack C18 column, 0.01 M PIC B7 and acetonitrile (40:60 v/v) pH 3.6, as mobile phase. Response was linear over the range 0.08-5.70 mu g mL(-1) (r = 0.996), with limits of detection and quantification (LOD and LOQ) of 0.17 and 0.35 mu g mL(-1), respectively.
Resumo:
The purpose of this study was to evaluate bioequivalence of two commercial 8 mg tablet formulations of ondansetrona available ill the Brazilian market. In this study, a simple, rapid, sensitive and selective liquid chromarography-tandem mass spectrometry method is described for the determination of ondansetron in human plasma samples. The method was validated over a concentration range of 2.5-60 ng/ml and used in a bioequivalence trial between orally disintegrating and conventional tablet ondansetron formulations, to assess its usefulness in this kind of Study. Vonau flash (R) (Biolab Sanus Farmaceutica, Brazil, as test formulations) and Zofran (R) (GlaxoSmithKline, Brazil, as reference formulation) were evaluated following a single 8 mg close to 23 healthy volunteers of both genders. The dose was administered after an overnight fast according to a two-way crossover design. Bioequivalence between the products was determinated by Calculating 90% confidence interval (90% CI) for the ratio of C(max), AUC(0-t) and AUC(0-(sic)) values for the test and reference products, using logarithmically transformed data. The 90% confidence interval for the ratio of C(max) (87.5-103.8%), AUC(0-t) (89.3-107.2%) and AUC(0--(sic)) (89.7-106.0%) values for the test and reference products is Within the 80-125% interval, proposed by FDA, EMEA and ANVISA. It was concluded that two ondansetron formulations are bioequivalent ill their rate and extent of absorption. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Dolastatin units were synthesized from the 1,2-addition reactions of potassium allyl or crotyltrifluoroborate salts to aldehyde derivatives from natural amino acids. The reactions were carried out in presence of a phase-transfer catalyst in a biphasic medium at room temperature and excellent yields (>89-93%) and stereoselective (>90:10 to 98:2) were obtained. The dolastatin units 8 and 14a-b were obtained after three steps in good overall yields (50-62%). (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
The aim of this study was the design of a set of benzofuroxan derivatives as antimicrobial agents exploring the physicochemical properties of the related substituents. Topliss` decision tree approach was applied to select the substituent groups. Hierarchical cluster analysis was also performed to emphasize natural clusters and patterns. The compounds were obtained using two synthetic approaches for reducing the synthetic steps as well as improving the yield. The minimal inhibitory concentration method was employed to evaluate the activity against multidrug-resistant Staphylococcus aureus strains. The most active compound was 4-nitro-3-(trifluoromethyl)[N`-(benzofuroxan-5-yl) methylene] benzhydrazide (MIC range 12.7-11.4 mu g/mL), pointing out that the antimicrobial activity was indeed influenced by the hydrophobic and electron-withdrawing property of the substituent groups 3-CF(3) and 4-NO(2), respectively. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
The aim of this study was to validate an agar diffusion method through the parameters linearity, precision and accuracy, to quantify apramycin in soluble powder. The calibration curve of apramycin was constructed by plotting log of concentrations (mu g ml(-1)) versus zone diameter (mm) and shows good linearity in the range of 1.0-4.0 mu g.ml(-1). The precision of the assay was determined by assaying samples at the same day (repeatability - R.S.D. = 2.00%) and on different days (intermediate precision - R.S.D. = 5.06%) and indicate good precision. The accuracy expresses the agreement between the accepted value and the value found. The mean recovery was found to be 100.49 % for apramycin soluble powder. The results indicated that the microbiological assay proposed in this work hold linearity, precision and accuracy being an acceptable alternative method for routine quality control of apramycin in the pharmaceutical dosage form studied.
Resumo:
New rapid first-derivative spectrophotometric (UVDS) and a stability-indicating high performance liquid chromatographic (HPLC) methods were developed, validated and successfully applied in the analysis of loratadine (LT) in tablets and syrups. In the UVDS method, 0.1 M HCl was used as solvent. The measurements were made at 312.4 nm in the first order derivative spectra. The HPLC method was carried out on a RP-18 column with a mobile phase composed of methanol-water-tetrahydrofuran (50:30:20, v/v/v). UV detection was made at 247 nm. For HPLC methods the total analysis time was <3min, adequate for routine quality control of tablets and syrups containing loratadine.