962 resultados para Ceramic pigments


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Changes in resource use over time can provide insight into technological choice and the extent of long-term stability in cultural practices. In this paper we re-evaluate the evidence for a marked demographic shift at the inception of the Early Iron Age at Troy by applying a robust macroscale analysis of changing ceramic resource use over the Late Bronze and Iron Age. We use a combination of new and legacy analytical datasets (NAA and XRF), from excavated ceramics, to evaluate the potential compositional range of local resources (based on comparisons with sediments from within a 10 km site radius). Results show a clear distinction between sediment-defined local and non-local ceramic compositional groups. Two discrete local ceramic resources have been previously identified and we confirm a third local resource for a major class of EIA handmade wares and cooking pots. This third source appears to derive from a residual resource on the Troy peninsula (rather than adjacent alluvial valleys). The presence of a group of large and heavy pithoi among the non-local groups raises questions about their regional or maritime origin. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

SUMMARY The aim of this study was to evaluate the influence of surface roughness on surface hardness (Vickers; VHN), elastic modulus (EM), and flexural strength (FLS) of two computer-aided design/computer-aided manufacturing (CAD/CAM) ceramic materials. One hundred sixty-two samples of VITABLOCS Mark II (VMII) and 162 samples of IPS Empress CAD (IPS) were ground according to six standardized protocols producing decreasing surface roughnesses (n=27/group): grinding with 1) silicon carbide (SiC) paper #80, 2) SiC paper #120, 3) SiC paper #220, 4) SiC paper #320, 5) SiC paper #500, and 6) SiC paper #1000. Surface roughness (Ra/Rz) was measured with a surface roughness meter, VHN and EM with a hardness indentation device, and FLS with a three-point bending test. To test for a correlation between surface roughness (Ra/Rz) and VHN, EM, or FLS, Spearman rank correlation coefficients were calculated. The decrease in surface roughness led to an increase in VHN from (VMII/IPS; medians) 263.7/256.5 VHN to 646.8/601.5 VHN, an increase in EM from 45.4/41.0 GPa to 66.8/58.4 GPa, and an increase in FLS from 49.5/44.3 MPa to 73.0/97.2 MPa. For both ceramic materials, Spearman rank correlation coefficients showed a strong negative correlation between surface roughness (Ra/Rz) and VHN or EM and a moderate negative correlation between Ra/Rz and FLS. In conclusion, a decrease in surface roughness generally improved the mechanical properties of the CAD/CAM ceramic materials tested. However, FLS was less influenced by surface roughness than expected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conducted work with two potential alternatives to Ni, La0.8Sr0.2Cr0.5Mn0.5 (LSCM) and Sr doped LaVO3 (LSV) to serve as the electron conductor in the anode of solid oxide fuel cells SOFCs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

From June 1997 to June 2003 we performed 194 total hip arthroplasties on 173 patients using alumina ceramic-on-ceramic bearings as part of a prospective United States Food and Drug Administration/Investigational Device Exemption study. The average patient age at surgery was 49.9 years. Minimum followup time was 2 years (mean 4.3 years, range 2-9 years). We evaluated survival rate, implant- and nonimplant-related complications. Clinical outcomes included the Merle d'Aubigné score. We assessed radiographs for signs of osteolysis, component loosening, and implant wear. No patients had osteolysis and there were no hip dislocations. Implant survivorship for all hips with aseptic revision of any component was 96% (CI, 91-100) at 9 year; survivorship for hips without prior surgery was 99.3%, (CI, 98-100). There was a 1.7% incidence of implant-related complications. Our data help confirm two United States FDA/IDE studies on alumina ceramic-on-ceramic total hip arthroplasty that reported low aseptic revision rates and low revision rates for instability. Total hip arthroplasty using alumina ceramic-on-ceramic implants is a safe and reliable procedure in the comparably young and active patient.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rehabilitation of a patient with advanced tooth wear by means of Procera ZrO2 ceramic crowns is described. A healthy, 60 year old patient complained about front teeth esthetics and impaired function due to reduced tooth height. He was aware of bruxism and wished full mouth rehabilitation. The clinical examination showed that tooth wear was generalized, but most teeth could be maintained in both jaws. A staged procedure was planned, starting with a splint therapy and a provisional fixed prosthesis to reestablish correct vertical dimension of occlusion (VDO) and stable occlusal contacts. The new ZrO2 material with the Procera technique was chosen to restore all teeth in both jaws, except the mandible front teeth. In the second treatment phase, crown lengthening of the maxillary front teeth was performed and one implant placed to replace a maxillary premolar. After final tooth preparation, impression taking and bite registration the ZrO2 crown-copings were scanned, processed and completed by veneering. A flat occlusal scheme with stable front teeth guidance was established. The advantage of the presented treatment is the esthetic result in combination with a material of high mechanical and biological quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

STATEMENT OF PROBLEM: AuTi alloys with 1.6% to 1.7% (wt%) Ti provide sufficient bond strength to veneering ceramics, but the strength of entire metal-ceramic restorations fabricated from these alloys is not known. However, this information is important to assess the clinical performance of such materials. PURPOSE: This in vitro study evaluated the fracture strength and thermal shock resistance of metal-ceramic crowns with AuTi frameworks produced by milling or casting. MATERIAL AND METHODS: Frameworks of the alloy Au-1.7Ti-0.1Ir (wt%) (Esteticor Vision) were produced by milling or casting (test groups). A high-gold alloy (Esteticor Special) was used as the control. The frameworks were veneered with ceramic (VMK 95). Specimens (n=7) were loaded until fracture. Loads at failure (N) were recorded and the mean values statistically evaluated using 1-way analysis of variance and a post hoc Dunnett test (alpha=.05). To assess the crazing resistance of the veneering ceramic, 6 additional crowns of each group were subjected to a thermal shock test. Fractured surfaces were documented by scanning electron microscopy. Coefficients of thermal expansion of the materials used were measured (n=2) to assess the thermal compatibility between alloys and ceramic. RESULTS: The mean fracture strength of the crowns with machined AuTi frameworks (1294 +/- 236 N) was significantly lower (P=.012) than that of the cast AuTi frameworks (1680 +/- 150 N), but statistically not different than the high-gold alloy (1449 +/- 159 N). Bonding failure to the AuTi alloy predominantly occurred at the alloy-oxide interface. For the high-gold alloy, more ceramic residues were observed. In the thermal shock test, crowns with milled AuTi frameworks showed significantly higher thermal shock resistance compared to the other groups. The coefficients of thermal expansion (Esteticor Vision cast: 14.5 microm/m.K; Esteticor Vision milled: 14.3 microm/m.K; Esteticor Special cast: 13.7 microm/m.K) did not correlate with the results of the thermal shock test. CONCLUSION: The in vitro fracture strength of crowns with milled AuTi frameworks is lower than that obtained with cast AuTi frameworks, but comparable to those crowns produced with a high-gold alloy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To assess in vitro the bond strength of a machined surface of a Au-Ti alloy to a veneering ceramic. Method and Materials: Metal strips of the alloy Au 1.7-Ti 0.1-Ir were milled from a semiproduct fabricated by continuous casting and cold forming. For comparison, the same alloy as well as a traditional Au-Pt-Pd-In alloy were used in the as-cast state. Six samples of each group were fabricated for the crack initiation test, according to ISO 9693:1999, by preparing appropriate metal strips that were veneered with ceramic using a standard firing procedure. The crack initiation test was performed in a universal testing machine. Load at fracture was recorded. Means of bond strength were calculated for each group and the results compared by use of a 1-sided Student t test (P < .05). Fracture sites were documented by means of SEM. Results: Bond strength in the 3 groups was in the same order of magnitude. Failure mode was different for both alloys. Failure of the bonding to the Au-Ti alloy predominantly occurred at the alloy-oxide interface, no matter which fabrication process was used. On the Au-Pt-Pd-In alloy, more ceramic residues were observed. Conclusion: The machined alloy Au 1.7-Ti 0.1-Ir provides sufficient bond strength to veneering ceramics, but this has to be proven by a clinical study. (Quintessence Int 2007;38:867-872).