924 resultados para Calculation tool in reliability


Relevância:

100.00% 100.00%

Publicador:

Resumo:

All-optical data processing is expected to play a major role in future optical communications. The fiber nonlinear optical loop mirror (NOLM) is a valuable tool in optical signal processing applications. This paper presents an overview of our recent advances in developing NOLM-based all-optical processing techniques for application in fiber-optic communications. The use of in-line NOLMs as a general technique for all-optical passive 2R (reamplification, reshaping) regeneration of return-to-zero (RZ) on-off keyed signals in both high-speed, ultralong-distance transmission systems and terrestrial photonic networks is reviewed. In this context, a theoretical model enabling the description of the stable propagation of carrier pulses with periodic all-optical self-regeneration in fiber systems with in-line deployment of nonlinear optical devices is presented. A novel, simple pulse processing scheme using nonlinear broadening in normal dispersion fiber and loop mirror intensity filtering is described, and its employment is demonstrated as an optical decision element at a RZ receiver as well as an in-line device to realize a transmission technique of periodic all-optical RZ-nonreturn-to-zero-like format conversion. The important issue of phase-preserving regeneration of phase-encoded signals is also addressed by presenting a new design of NOLM based on distributed Raman amplification in the loop fiber. © 2008 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper examines the extent to which a learning organisation perspective is attainable in small- to medium-sized manufacturing companies. An audit tool is developed from the literature on organisational learning and recognised processes that lead towards becoming a learning organisation. The paper focuses on the application of the audit tool in three UK automotive component suppliers which are all experiencing pressures for change imposed by the major vehicle manufacturers. The main changes are concerned with tiering of the supply chain and substantial delegation of responsibilities to component suppliers including an increasing emphasis on innovation and continuous improvement. The companies presented in the paper are taken from a research project into the impact of changes in supply chain relationships on the operation of small- and medium-sized manufacturing firms in the West Midlands region of the UK. The ways in which the companies are responding to change are presented together with the results of a self-assessment using the developed audit tool. These results suggest that companies of this type tend to focus on change in those areas that involve least challenge to the established power and authority of management.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

CONTEXT: The homeless are a significant group within society, which is increasing in size. They have demonstrably greater physical and mental health needs than the housed, and yet often have difficulty accessing primary health care. Medical 'reluctance' to look after homeless people is increasingly suggested as part of the problem. Medical education may have a role in ameliorating this. OBJECTIVES: This paper reports on the development and validation of a questionnaire specifically developed to measure medical students' attitudes towards the homeless. METHOD AND RESULTS: The Attitudes Towards the Homeless Questionnaire, developed using the views of over 370 medical students, was shown to have a Pearson test-retest reliability correlation coefficient of 0.8 and a Cronbach's alpha coefficient of 0.74. CONCLUSIONS: The Attitudes Towards the Homeless Questionnaire appears to be a valid and reliable instrument, which can measure students' attitudes towards the homeless. It could be a useful tool in assessing the effectiveness of educational interventions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Certain species of crustose lichens have concentrically zoned margins which probably represent yearly growth rings. These marginal growth rings offer an alternative method of studying annual growth fluctuations, establishing growth rate-size curves, and determining the age of thalli for certain crustose species. Hence, marginal growth rings represent a potentially valuable, unexploited, tool in lichenometry. In a preliminary study, we measured the widths of the successive marginal rings in 25 thalli of Ochrolechia parella (L.) Massal., growing at a maritime site in north Wales. Mean ring widths of all thalli varied from a minimum of 1.02 mm (the outermost ring) to a maximum of 2.06 mm (the third ring from the margin). There is some suggestion that marginal ring width and thallus size are positively correlated; and hence that growth rates increase in larger thalli in this small population. In a further study on recently exposed bedrock adjacent to Breidalon, SE Iceland, we examined the potential for using marginal growth rings to estimate thallus age of a lichen tentatively identified as a Rhizocarpon (possibly R. concentricum (Davies) Beltram.) and thus confirm the timing of surface exposure (c. 50 years). Collectively, these results suggest: 1) the measurement of marginal rings is a possible alternative method of studying the growth of crustose lichens; 2) O. parella may grow differently to other crustose species, exhibiting a rapidly increasing radial growth rate in thalli >40 mm; 3) where lichens with marginal rings grow on recently exposed surfaces (<60 yrs), minimum age estimates can be made using growth rings as an in situ indication of lichen growth rate; 4) it is suggested that this phenomenon could provide a valuable, previously unexploited, in situ lichenometric-dating tool in areas lacking calibration control.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ambulatory EEG recording enables patients with epilepsy and related disorders to be monitored in an unrestricted environment for prolonged periods. Attacks can therefore be recorded and EEG changes at the time can aid diagnosis. The relevant Iiterature is reviewed and a study made of' 250 clinical investigations. A study was also made of the artefacts,encountered during ambulatory recording. Three quarters of referrals were for distinguishing between epileptic and non-epileptic attacks. Over 60% of patients showed no abnormality during attacks. In comparison with the basic EEG the ambulatory EEG provided about ten times as much information. A preliminary follow-up study showed that results, of ambulatory monitoring agreed with the final diagnosis in 8 of 12 patients studied. Of 10 patients referred, for monitoring the occurrence of absence seizures, 8 showed abnormality during the baslcJ EEG .and 10 during the ambulatory EEG. Other patients. were referred: for sleep recording and to clarify the seizure type. An investigation into once daily (OD) versus twice daily administration of sodium valproate in patients with absence seizures showed that an OD regime was equally as effective as a BD regime. Circadian variations in spike and wave activity in patients on and off treatment were also examined. There was significant agreement between subjects on the time of occurrence of abnormality during sleep only, This pattern was not ,affected with treatment nor was there any difference in the daily pattern of occurrence of abnormality between the two regimes. Overall findings suggested that ambulatory monitoring was a valuable tool in the diagnosis and treatment of epilepsy which with careful planning and patient selection could be used in any EEG department and would benefit a:wide range of patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of the following studies was to explore the effect of systemic vascular and endothelial dysfunction upon the ocular circulation and functionality of the retina. There are 6 principal sections to the present work. Retinal vessel activity in smokers and non-smokers: the principal findings of this work were: chronic smoking affects retinal vessel motion at baseline and during stimulation with flickering light; chronic smoking leads to a vaso-constrictory shift in retinal arteriolar reactivity to flicker; retinal arteriolar elasticity is decreased in chronic smokers. The effect of acute smoking on retinal vessel dynamics in smokers and non-smokers: the principal finding of this work was that retinal reactivity in chronic smokers is blunted when exposed to clicker light provocation immediately after smoking one cigarette. Ocular blood flow in coronary artery disease: The principal findings of this work were: retrobulbar and retinal blood flow is preserved in CAD patients, despite a change pulse wave transmission; arterial retinal response to flickering light provocation is significantly delayed in CAD patients; retinal venular diameters are significantly dilated in CAD patients. Autonomic nervous system function and peripheral circulation in CAD: The principal findings in this work were: CAD patients demonstrate a sympathetic overdrive during a 24 period; a delay in peripheral vascular reactivity (nail-fold capillaries) as observed in patients suffering from CAD could be caused by either arteriosclerotic changes of the vascular walls or due to systemic haemodynamic changes. Visual function in CAD: The principal findings in this work were: overall visual function in CAD patients is preserved, despite a decrease in contrast sensitivity; applying a filtering technique selecting those with greater coefficient of variance which in turn represents a decrease in reliability, some patients appear to have an impaired visual function as assessed using FDT visual field evaluation. Multiple functional, structural and biochemical vascular endothelial dysfunctions in patients suffering from CAD: relationships and possible implications: The principal findings of this work were: BMI significantly correlated with vWF (a marker of endothelial function) in CAD patients. Retinal vascular reactivity showed a significant correlation with peripheral reactivity parameters in controls which lacked in the CAD group and could reflect a loss in vascular endothelial integrity; visual field parameters as assessed by frequency doubling technology were strongly related with systemic vascular elasticity (ambulatory arterial stiffness index) in controls but not CAD patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background - An evaluation of standard automated perimetry (SAP) and short wavelength automated perimetry (SWAP) for the central 10–2 visual field test procedure in patients with age-related macular degeneration (AMD) is presented in order to determine methods of quantifying the central sensitivity loss in patients at various stages of AMD. Methods - 10–2 SAP and SWAP Humphrey visual fields and stereoscopic fundus photographs were collected in 27 eyes of 27 patients with AMD and 22 eyes of 22 normal subjects. Results - Mean Deviation and Pattern Standard Deviation (PSD) varied significantly with stage of disease in SAP (both p<0.001) and SWAP (both p<0.001), but post hoc analysis revealed overlap of functional values among stages. In SWAP, indices of focal loss were more sensitive to detecting differences in AMD from normal. SWAP defects were greater in depth and area than those in SAP. Central sensitivity (within 1°) changed by -3.9 and -4.9 dB per stage in SAP and SWAP, respectively. Based on defect maps, an AMD Severity Index was derived. Conclusions - Global indices of focal loss were more sensitive to detecting early stage AMD from normal. The SWAP sensitivity decline with advancing stage of AMD was greater than in SAP. A new AMD Severity Index quantifies visual field defects on a continuous scale. Although not all patients are suitable for SWAP examinations, it is of value as a tool in research studies of visual loss in AMD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Macular oedema is not directly visible on digital photographs used in screening. Photographic surrogate markers are used to detect patients who may have macular oedema. Evidence suggests that only around 10% of patients with these surrogate markers referred to an ophthalmologist have macular oedema when examined by slit-lamp biomicroscopy. Purpose: The purpose of this audit was to determine how many patients with surrogate markers were truly identified by optical coherence tomography (OCT) as having macular oedema. Method: Data were collected from patients attending digital diabetic retinopathy screening. Patients who presented with surrogate markers for macular oedema also had an OCT scan. The fast macula scan on the Stratus OCT was used and an ophthalmologist reviewed the scans to determine whether macular oedema was present. Results: Out of 66 patients with maculopathy defined as haemorrhages or microaneurysms within one optic disc diameter (DD) of the fovea and visual acuity (VA) worse than 6/9 11 (17%) showed thickening on the OCT, only 4 (6%) had macular oedema. None required laser. Out of 155 patients with maculopathy defined as any exudate within one DD of the fovea or circinate within two DD 45 (29%) showed thickening on the OCT of these 27% required laser. Conclusion: OCT is a useful tool in screening to help identify those who need a true referral to ophthalmology for maculopathy. If exudate is present the chance of having macular oedema and requiring laser treatment is greater than the presence of microaneurysms within one DD and reduced VA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Vaccines remain a key tool in the defence against major diseases. However, in the development of vaccines a trade off between safety and efficacy is required with newer vaccines, based on sub-unit proteins and peptides, displaying improved safety profiles yet suffering from low efficacy. Adjuvants can be employed to improve their potency, but currently there are only a limited number of adjuvant systems licensed for clinical use. Of the new adjuvants being investigated, particulate systems offer several advantages including: passive targeting to the antigen-presenting cells within the immune system, protection against adjuvant degradation, and ability for sustained antigen release. There has been a range of particulate vaccine delivery systems outlined in recent patents including polymer-based microspheres (which are generally more focused on the use of synthetic polymers, in particular the polyesters) and surfactant-based vesicles. Within these formulations, several patented systems are exploiting the use of cationic lipids which, despite their limitations in gene therapy, clearly offer strong potential as adjuvants. Within this review, the current range of particulate system technologies being investigated as potential adjuvants are discussed with regard to both their respective advantages and the potential hurdles which must be overcome for such systems to be converted into successful pharmaceutical products.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Previous research into formulaic language has focussed on specialised groups of people (e.g. L1 acquisition by infants and adult L2 acquisition) with ordinary adult native speakers of English receiving less attention. Additionally, whilst some features of formulaic language have been used as evidence of authorship (e.g. the Unabomber’s use of you can’t eat your cake and have it too) there has been no systematic investigation into this as a potential marker of authorship. This thesis reports the first full-scale study into the use of formulaic sequences by individual authors. The theory of formulaic language hypothesises that formulaic sequences contained in the mental lexicon are shaped by experience combined with what each individual has found to be communicatively effective. Each author’s repertoire of formulaic sequences should therefore differ. To test this assertion, three automated approaches to the identification of formulaic sequences are tested on a specially constructed corpus containing 100 short narratives. The first approach explores a limited subset of formulaic sequences using recurrence across a series of texts as the criterion for identification. The second approach focuses on a word which frequently occurs as part of formulaic sequences and also investigates alternative non-formulaic realisations of the same semantic content. Finally, a reference list approach is used. Whilst claiming authority for any reference list can be difficult, the proposed method utilises internet examples derived from lists prepared by others, a procedure which, it is argued, is akin to asking large groups of judges to reach consensus about what is formulaic. The empirical evidence supports the notion that formulaic sequences have potential as a marker of authorship since in some cases a Questioned Document was correctly attributed. Although this marker of authorship is not universally applicable, it does promise to become a viable new tool in the forensic linguist’s tool-kit.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Developers of interactive software are confronted by an increasing variety of software tools to help engineer the interactive aspects of software applications. Typically resorting to ad hoc means of tool selection, developers are often dissatisfied with their chosen tool on account of the fact that the tool lacks required functionality or does not fit seamlessly within the context in which it is to be used. This paper describes a system for evaluating the suitability of user interface development tools for use in software development organisations and projects such that the selected tool appears ‘invisible’ within its anticipated context of use. The paper also outlines and presents the results of an informal empirical study and a series of observational case studies of the system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Liquid-level sensing technologies have attracted great prominence, because such measurements are essential to industrial applications, such as fuel storage, flood warning and in the biochemical industry. Traditional liquid level sensors are based on electromechanical techniques; however they suffer from intrinsic safety concerns in explosive environments. In recent years, given that optical fiber sensors have lots of well-established advantages such as high accuracy, costeffectiveness, compact size, and ease of multiplexing, several optical fiber liquid level sensors have been investigated which are based on different operating principles such as side-polishing the cladding and a portion of core, using a spiral side-emitting optical fiber or using silica fiber gratings. The present work proposes a novel and highly sensitive liquid level sensor making use of polymer optical fiber Bragg gratings (POFBGs). The key elements of the system are a set of POFBGs embedded in silicone rubber diaphragms. This is a new development building on the idea of determining liquid level by measuring the pressure at the bottom of a liquid container, however it has a number of critical advantages. The system features several FBG-based pressure sensors as described above placed at different depths. Any sensor above the surface of the liquid will read the same ambient pressure. Sensors below the surface of the liquid will read pressures that increase linearly with depth. The position of the liquid surface can therefore be approximately identified as lying between the first sensor to read an above-ambient pressure and the next higher sensor. This level of precision would not in general be sufficient for most liquid level monitoring applications; however a much more precise determination of liquid level can be made by linear regression to the pressure readings from the sub-surface sensors. There are numerous advantages to this multi-sensor approach. First, the use of linear regression using multiple sensors is inherently more accurate than using a single pressure reading to estimate depth. Second, common mode temperature induced wavelength shifts in the individual sensors are automatically compensated. Thirdly, temperature induced changes in the sensor pressure sensitivity are also compensated. Fourthly, the approach provides the possibility to detect and compensate for malfunctioning sensors. Finally, the system is immune to changes in the density of the monitored fluid and even to changes in the effective force of gravity, as might be obtained in an aerospace application. The performance of an individual sensor was characterized and displays a sensitivity (54 pm/cm), enhanced by more than a factor of 2 when compared to a sensor head configuration based on a silica FBG published in the literature, resulting from the much lower elastic modulus of POF. Furthermore, the temperature/humidity behavior and measurement resolution were also studied in detail. The proposed configuration also displays a highly linear response, high resolution and good repeatability. The results suggest the new configuration can be a useful tool in many different applications, such as aircraft fuel monitoring, and biochemical and environmental sensing, where accuracy and stability are fundamental. © (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Magnetoencephalographic (MEG) signals, like electroencephalographic (EEG) measures, are the direct extracranial manifestations of neuronal activation. The two techniques can detect time-varying changes in electromagnetic activity with a sub-millisecond time resolution. Extra-cranial electromagnetic measures are the cornerstone of the non-invasive diagnostic armamentarium in patients with epilepsy. Their extremely high temporal resolution – comparable to intracranial recordings – is the basis for a precise definition of onset and propagation of ictal and interictal abnormalities. Given the cost of the infrastructure and equipment, MEG has yet to develop into a routinely applicable diagnostic tool in clinical settings. However, in recent years, an increasing number of patients with epilepsy have been investigated – usually in the context of presurgical evaluation of refractory epilepsies – and initial encouraging results have been reported. We will briefly review the principles and the technology behind MEG and its contribution in the diagnostic work-up of patients with epilepsy.