976 resultados para Bartington loop sensor 80 mm ID (Core) or Antares Slimhole Probe (Borehole)


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The implantable loop recorder developed by Medtronic (Reveal plus) is a small device inserted subcutaneously under local anesthesia in patients with syncope of unexplained origin. This device enables a single lead-ECG recording and has autonomy of two years. Memories are activated during episodes of bradycardia or tachycardia, either automatically or manually. Several studies have shown a high diagnostic rate reaching 50% and demonstrated its cost-effectiveness. There is also a significant reduction in syncopal episodes and a higher quality of life score in patients with syncope of unexplained origin.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The object of this study was to evaluate the contribution of carotid distensibilty on baroreflex sensitivity in patients with type 2 diabetes mellitus with at least 2 additional cardiovascular risk factors. Carotid distensibility was measured bilaterally at the common carotid artery in 79 consecutive diabetic patients and 60 matched subjects without diabetes. Spontaneous baroreflex sensitivity assessment was obtained using time and frequency methods. Baroreflex sensitivity was lower in diabetic subjects as compared with nondiabetic control subjects (5.25+/-2.80 ms/mm Hg versus 7.55+/-3.79 ms/mm Hg; P<0.01, respectively). Contrary to nondiabetic subjects, diabetic subjects showed no significant correlation between carotid distensibility and baroreflex sensitivity (r2=0.08, P=0.04 and r2=0.04, P=0.13, respectively). In diabetic subjects, baroreflex sensitivity was significantly lower in subjects with peripheral neuropathy than in those with preserved vibration sensation (4.1+/-0.5 versus 6.1+/-0.4 ms/mm Hg, respectively; P=0.005). Age in nondiabetic subjects, diabetes duration, systolic blood pressure, peripheral or sensitive neuropathy, and carotid distensibility were introduced in a stepwise multivariate analysis to identify the determinants of baroreflex sensitivity. In diabetic patients, neuropathy is a more sensitive determinant of baroreflex sensitivity than the reduced carotid distensibility (stepwise analysis; F ratio=5.1, P=0.028 versus F ratio=1.9, P=0.16, respectively). In diabetic subjects with 2 additional cardiovascular risk factors, spontaneous baroreflex sensitivity is not related to carotid distensibility. Diabetic subjects represent a particular population within the spectrum of cardiovascular risk situations because of the marked neuropathy associated with their metabolic disorder. Therefore, neuropathy is a more significant determinant of baroreflex sensitivity than carotid artery elasticity in patients with type 2 diabetes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

To compare the prediction of hip fracture risk of several bone ultrasounds (QUS), 7062 Swiss women > or =70 years of age were measured with three QUSs (two of the heel, one of the phalanges). Heel QUSs were both predictive of hip fracture risk, whereas the phalanges QUS was not. INTRODUCTION: As the number of hip fracture is expected to increase during these next decades, it is important to develop strategies to detect subjects at risk. Quantitative bone ultrasound (QUS), an ionizing radiation-free method, which is transportable, could be interesting for this purpose. MATERIALS AND METHODS: The Swiss Evaluation of the Methods of Measurement of Osteoporotic Fracture Risk (SEMOF) study is a multicenter cohort study, which compared three QUSs for the assessment of hip fracture risk in a sample of 7609 elderly ambulatory women > or =70 years of age. Two QUSs measured the heel (Achilles+; GE-Lunar and Sahara; Hologic), and one measured the heel (DBM Sonic 1200; IGEA). The Cox proportional hazards regression was used to estimate the hazard of the first hip fracture, adjusted for age, BMI, and center, and the area under the ROC curves were calculated to compare the devices and their parameters. RESULTS: From the 7609 women who were included in the study, 7062 women 75.2 +/- 3.1 (SD) years of age were prospectively followed for 2.9 +/- 0.8 years. Eighty women reported a hip fracture. A decrease by 1 SD of the QUS variables corresponded to an increase of the hip fracture risk from 2.3 (95% CI, 1.7, 3.1) to 2.6 (95% CI, 1.9, 3.4) for the three variables of Achilles+ and from 2.2 (95% CI, 1.7, 3.0) to 2.4 (95% CI, 1.8, 3.2) for the three variables of Sahara. Risk gradients did not differ significantly among the variables of the two heel QUS devices. On the other hand, the phalanges QUS (DBM Sonic 1200) was not predictive of hip fracture risk, with an adjusted hazard risk of 1.2 (95% CI, 0.9, 1.5), even after reanalysis of the digitalized data and using different cut-off levels (1700 or 1570 m/s). CONCLUSIONS: In this elderly women population, heel QUS devices were both predictive of hip fracture risk, whereas the phalanges QUS device was not.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: To evaluate the long-term efficacy of multilayer amniotic membrane transplantation for reconstruction of epithelium and stroma in non-traumatic corneal perforations (less than 2 mm) or deep ulcers with descemetocele.Design: Retrospective, non-comparative, interventional case series.Patients and Methods: Eleven consecutive patients with non-traumatic corneal perforations or deep corneal ulcers with descemetocele refractory to conventional treatments: herpetic or zoster keratitis (n = 4), Sjögren's syndrome (n = 2), rosacea (n = 1), hydrops (n = 1), mucous membrane pemphigoid (n = 1), bacterial keratitis (n = 1) and perforation after protontherapy for melanoma (n = 1). Intervention was: multilayer amniotic membrane transplantation with cryopreserved amniotic membrane. Complication rate and clinical outcome were evaluated in this long-term follow-up.Results: Mean follow-up was 32 months (12 to 60). Integration of the multilayer amniotic membrane was obtained in 10 cases after one year. Corneal epithelium healed above the membrane in 10 cases within 3 weeks and remained stable after 32 months in 9 cases. Thickness of the stroma was increased and remained stable during the follow-up in 9 cases. In one case herpetic keratitis recurred with a corneal perforation. The clearing of the amniotic membrane was gradually obtained over a period of 11 months. Complications occurred in 15 % of the eyes during the long-term follow-up.Conclusion: Multilayer amniotic membrane transplantation is a safe and efficient technique for a long restoration of the corneal integrity after non-traumatic corneal perforations or deep corneal ulcers with descemetocele. Long-term prognosis of these eyes depends of the gravity of the initial disease.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE: Prostate cancer is the most commonly diagnosed cancer in the United States. The diagnosis or followup of prostate cancer in men older than 50 years is based on digital rectal examination, measurement of the free-to-total prostatic specific antigen ratio and transrectal ultrasound assisted needle biopsy of the prostate. We developed and evaluated a noninvasive method for diagnosing prostate cancer based on the measurement of telomerase activity after prostatic massage in fresh voided urine or after urethral washing. MATERIALS AND METHODS: We obtained 36 specimens of cells after prostatic massage in the fresh voided urine of 16 patients who subsequently underwent radical prostatectomy and after urethral washing in 20 who underwent prostate needle biopsies. Ethylenediaminetetraacetic acid was immediately added to the collected urine or washing to a final concentration of 20 mM. After protein extraction by CHAPS buffer each specimen was tested for telomerase activity in a 2-step modified telomeric repeat amplification protocol assay. The 2 prostate cancer cell lines PC-3 and LNCaP with high telomerase activity were used as a positive control. RESULTS: Telomerase activity was detected in 14 of 24 samples with known prostate cancer (sensitivity 58%). In contrast, no telomerase activity was found in the 12 cases without histological evidence of prostate tumor (specificity 100%). Eight of 9 poorly differentiated cancers expressed telomerase activity (89%), while only 6 of 15 well and moderately differentiated cancers showed telomerase activity (40%). CONCLUSIONS: Our data illustrate that telomerase activity may be detected in voided urine or washing after prostatic massage in patients with prostate cancer. Sensitivity was higher for poorly differentiated tumors. This approach is not currently available for detecting prostate cancer in clinical practice. However, these results are promising and further studies are ongoing.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

AIMS: Managing patients with alcohol dependence includes assessment for heavy drinking, typically by asking patients. Some recommend biomarkers to detect heavy drinking but evidence of accuracy is limited. METHODS: Among people with dependence, we assessed the performance of disialo-carbohydrate-deficient transferrin (%dCDT, 805;1.7%), gamma-glutamyltransferase (GGT, 805;66 U/l), either %dCDT or GGT positive, and breath alcohol (> 0) for identifying 3 self-reported heavy drinking levels: any heavy drinking (805;4 drinks/day or >7 drinks/week for women, 805;5 drinks/day or >14 drinks/week for men), recurrent (805;5 drinks/day on 805;5 days) and persistent heavy drinking (805;5 drinks/day on 805;7 consecutive days). Subjects (n = 402) with dependence and current heavy drinking were referred to primary care and assessed 6 months later with biomarkers and validated self-reported calendar method assessment of past 30-day alcohol use. RESULTS: The self-reported prevalence of any, recurrent and persistent heavy drinking was 54, 34 and 17%. Sensitivity of %dCDT for detecting any, recurrent and persistent self-reported heavy drinking was 41, 53 and 66%. Specificity was 96, 90 and 84%, respectively. %dCDT had higher sensitivity than GGT and breath test for each alcohol use level but was not adequately sensitive to detect heavy drinking (missing 34-59% of the cases). Either %dCDT or GGT positive improved sensitivity but not to satisfactory levels, and specificity decreased. Neither a breath test nor GGT was sufficiently sensitive (both tests missed 70-80% of cases). CONCLUSIONS: Although biomarkers may provide some useful information, their sensitivity is low the incremental value over self-report in clinical settings is questionable.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE: The natural history of prostate cancer might be driven by the index lesion. We determined the percent of men in whom the index lesion could be defined using transperineal template prostate mapping biopsies. MATERIALS AND METHODS: Included in study were consecutive men undergoing transperineal template prostate mapping biopsies with biopsies grouped into 20 zones. Men with clinically significant disease in only 1 prostate area were considered to have an identifiable index lesion. We evaluated the impact of using 2 definitions of clinically significant disease (Gleason grade pattern 4 and/or lesion volume 0.5 cc or greater) and 2 clustering rules (stringent and tolerant) to define the index lesion. RESULTS: Included in study were 391 men with a median age of 62 years (IQR 58-67) and a median prostate specific antigen of 6.9 ng/ml (IQR 4.8-10.0). Of the men 269 (69%) were previously diagnosed with prostate cancer. By deploying a median of 1.2 cores per ml (IQR 0.9-1.7) cancer was diagnosed in 82.9% of the men (324 of 391) with a median of 6 positive cores (IQR 2-9), a median maximum cancer core length of 5 mm (IQR 3-8) and a total cancer core length per zone of 7 mm (IQR 3-13). Insignificant disease was found in 26.3% to 42.9% of cases. When a stringent spatial relationship was used to define individual lesions, 44.4% to 54.6% of patients had 1 index lesion and 12.7% to 19.1% had more than 1 area with clinically significant disease. These proportions changed to 46.6% to 59.2% and 10.5% to 14.5%, respectively, when less stringent spatial clustering was applied. CONCLUSIONS: Transperineal template prostate mapping biopsies enable the index lesion to be localized in most men with clinically significant disease. This information may be important to select appropriate candidates for targeted therapy and to plan a tailored treatment strategy in men undergoing radical therapy.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: In acute respiratory failure, arterial blood gas analysis (ABG) is used to diagnose hypercapnia. Once non-invasive ventilation (NIV) is initiated, ABG should at least be repeated within 1 h to assess PaCO2 response to treatment in order to help detect NIV failure. The main aim of this study was to assess whether measuring end-tidal CO2 (EtCO2) with a dedicated naso-buccal sensor during NIV could predict PaCO2 variation and/or PaCO2 absolute values. The additional aim was to assess whether active or passive prolonged expiratory maneuvers could improve the agreement between expiratory CO2 and PaCO2. METHODS: This is a prospective study in adult patients suffering from acute hypercapnic respiratory failure (PaCO2 805; 45 mmHg) treated with NIV. EtCO2 and expiratory CO2 values during active and passive expiratory maneuvers were measured using a dedicated naso-buccal sensor and compared to concomitant PaCO2 values. The agreement between two consecutive values of EtCO2 (delta EtCO2) and two consecutive values of PaCO2 (delta PaCO2) and between PaCO2 and concomitant expiratory CO2 values was assessed using the Bland and Altman method adjusted for the effects of repeated measurements. RESULTS: Fifty-four datasets from a population of 11 patients (8 COPD and 3 non-COPD patients), were included in the analysis. PaCO2 values ranged from 39 to 80 mmHg, and EtCO2 from 12 to 68 mmHg. In the observed agreement between delta EtCO2 and deltaPaCO2, bias was -0.3 mmHg, and limits of agreement were -17.8 and 17.2 mmHg. In agreement between PaCO2 and EtCO2, bias was 14.7 mmHg, and limits of agreement were -6.6 and 36.1 mmHg. Adding active and passive expiration maneuvers did not improve PaCO2 prediction. CONCLUSIONS: During NIV delivered for acute hypercapnic respiratory failure, measuring EtCO2 using a dedicating naso-buccal sensor was inaccurate to predict both PaCO2 and PaCO2 variations over time. Active and passive expiration maneuvers did not improve PaCO2 prediction. TRIAL REGISTRATION: ClinicalTrials.gov: NCT01489150.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Tutkimuksen tavoitteena on tarkastella tekijöitä, joista ydinosaaminen muodostuu, sekä sitä kuinka yritykset voisivat parhaiten hyödyntää omia resurssejaan ja osaamistaan tunnistetun ydinosaamisen avulla. Teoria osuudessa käydään läpi kuinka ydinosaaminen on kirjallisuudessa määritelty ja miten yritykset voivat sen määritellä sisäisesti itselleen. Empiirisessä osiossa käydään läpi Telecom Business Research Centerissä tehdyn kvantitatiivisen selvityksen pohjalta valitut kolme sisällöntuottaja case - yritystä sekä kuvataan näiden osaamista. Tiedot yrityksistä perustuvat niiden edustajille tehtyihin haastatteluihin ja heidän käsitykseensä omasta yrityksestään. Tämä näkemys on tutkimuksen kannalta äärimmäisen relevanttia, koska ydinosaamisen määrittely tehdään yrityksessä sisäisesti juuri haastatellun kaltaisten yrityksen ydintoimijoiden toimesta. Varsinaisten case -yritysten lisäksi käydään läpi käytännön tapaus action-oriented -tutkimusosuudessa. Tutkimusta ja siinä käsiteltyjä esimerkkejä tulisi hyödyntää yrityksen oman ydinosaamisselvityksen apuna prosessin varrella.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

INTRODUCTION: Perfusion-CT (PCT) processing involves deconvolution, a mathematical operation that computes the perfusion parameters from the PCT time density curves and an arterial curve. Delay-sensitive deconvolution does not correct for arrival delay of contrast, whereas delay-insensitive deconvolution does. The goal of this study was to compare delay-sensitive and delay-insensitive deconvolution PCT in terms of delineation of the ischemic core and penumbra. METHODS: We retrospectively identified 100 patients with acute ischemic stroke who underwent admission PCT and CT angiography (CTA), a follow-up vascular study to determine recanalization status, and a follow-up noncontrast head CT (NCT) or MRI to calculate final infarct volume. PCT datasets were processed twice, once using delay-sensitive deconvolution and once using delay-insensitive deconvolution. Regions of interest (ROIs) were drawn, and cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) in these ROIs were recorded and compared. Volume and geographic distribution of ischemic core and penumbra using both deconvolution methods were also recorded and compared. RESULTS: MTT and CBF values are affected by the deconvolution method used (p < 0.05), while CBV values remain unchanged. Optimal thresholds to delineate ischemic core and penumbra are different for delay-sensitive (145 % MTT, CBV 2 ml × 100 g(-1) × min(-1)) and delay-insensitive deconvolution (135 % MTT, CBV 2 ml × 100 g(-1) × min(-1) for delay-insensitive deconvolution). When applying these different thresholds, however, the predicted ischemic core (p = 0.366) and penumbra (p = 0.405) were similar with both methods. CONCLUSION: Both delay-sensitive and delay-insensitive deconvolution methods are appropriate for PCT processing in acute ischemic stroke patients. The predicted ischemic core and penumbra are similar with both methods when using different sets of thresholds, specific for each deconvolution method.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: This study aimed to determine 5-year efficacy of catheter ablation for persistent atrial fibrillation (AF) using AF termination as a procedural end point. METHODS AND RESULTS: One hundred fifty patients (57±10 years) underwent persistent AF ablation using a stepwise ablation approach (pulmonary vein isolation, electrogram-guided, and linear ablation) with the desired procedural end point being AF termination. Repeat ablation was performed for recurrent AF or atrial tachycardia. AF was terminated by ablation in 120 patients (80%). Arrhythmia-free survival rates after a single procedure were 35.3%±3.9%, 28.0%±3.7%, and 16.8%±3.2% at 1, 2, and 5 years, respectively. Arrhythmia-free survival rates after the last procedure (mean 2.1±1.0 procedures) were 89.7%±2.5%, 79.8%±3.4%, and 62.9%±4.5%, at 1, 2, and 5 years, respectively. During a median follow-up of 58 (interquartile range, 43-73) months after the last ablation procedure, 97 of 150 (64.7%) patients remained in sinus rhythm without antiarrhythmic drugs. Another 14 (9.3%) patients maintained sinus rhythm after reinitiation of antiarrhythmic drugs, and an additional 15 (10.0%) patients regressed to paroxysmal recurrences only. Failure to terminate AF during the index procedure (hazard ratio 3.831; 95% confidence interval, 2.070-7.143; P<0.001), left atrial diameter 805;50 mm (hazard ratio 2.083; 95% confidence interval, 1.078-4.016; P=0.03), continuous AF duration 805;18 months (hazard ratio 1.984; 95% confidence interval, 1.024-3.846; P<0.04), and structural heart disease (hazard ratio 1.874; 95% confidence interval, 1.037-3.388; P=0.04) predicted arrhythmia recurrence. CONCLUSIONS: In patients with persistent AF, an ablation strategy aiming at AF termination is associated with freedom from arrhythmia recurrence in the majority of patients over a 5-year follow-up period. Procedural AF nontermination and specific baseline factors predict long-term outcome after ablation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In order to improve the efficacy and safety of treatments, drug dosage needs to be adjusted to the actual needs of each patient in a truly personalized medicine approach. Key for widespread dosage adjustment is the availability of point-of-care devices able to measure plasma drug concentration in a simple, automated, and cost-effective fashion. In the present work, we introduce and test a portable, palm-sized transmission-localized surface plasmon resonance (T-LSPR) setup, comprised of off-the-shelf components and coupled with DNA-based aptamers specific to the antibiotic tobramycin (467 Da). The core of the T-LSPR setup are aptamer-functionalized gold nanoislands (NIs) deposited on a glass slide covered with fluorine-doped tin oxide (FTO), which acts as a biosensor. The gold NIs exhibit localized plasmon resonance in the visible range matching the sensitivity of the complementary metal oxide semiconductor (CMOS) image sensor employed as a light detector. The combination of gold NIs on the FTO substrate, causing NIs size and pattern irregularity, might reduce the overall sensitivity but confers extremely high stability in high-ionic solutions, allowing it to withstand numerous regeneration cycles without sensing losses. With this rather simple T-LSPR setup, we show real-time label-free detection of tobramycin in buffer, measuring concentrations down to 0.5 μM. We determined an affinity constant of the aptamer-tobramycin pair consistent with the value obtained using a commercial propagating-wave based SPR. Moreover, our label-free system can detect tobramycin in filtered undiluted blood serum, measuring concentrations down to 10 μM with a theoretical detection limit of 3.4 μM. While the association signal of tobramycin onto the aptamer is masked by the serum injection, the quantification of the captured tobramycin is possible during the dissociation phase and leads to a linear calibration curve for the concentrations over the tested range (10-80 μM). The plasmon shift following surface binding is calculated in terms of both plasmon peak location and hue, with the latter allowing faster data elaboration and real-time display of the results. The presented T-LSPR system shows for the first time label-free direct detection and quantification of a small molecule in the complex matrix of filtered undiluted blood serum. Its uncomplicated construction and compact size, together with the remarkable performances, represent a leap forward toward effective point-of-care devices for therapeutic drug concentration monitoring.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Which treatments are used for dysmenorrhea and with what reported outcome? A questionnaire was sent to 2400 students and apprentices, following the "retrospective treatment-outcome" method. The response rate was 22%. Most frequent treatments used are ibuprofene (53%), paracetamol (51%), hormonal contraception (40%), hot-water bottle (or hot pad) (35%), food supplements or medicinal plants (23%). Physicians only discuss a tiny proportion of dysmenorrhea treatment in their consultation, because it is mostly a matter of self-treatment, with the family as the source of information in 80% of the cases. Rather surprising because not mentioned in most official guidelines, hot-water bottle (or hot pad) appears as the treatment followed by the best reported outcome (satisfactory in 92% of users).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Survival outcomes for patients with glioblastoma remain poor, particularly for patients with unmethylated O(6)-methylguanine-DNA methyltransferase (MGMT) gene promoter. This phase II, randomized, open-label, multicenter trial investigated the efficacy and safety of 2 dose regimens of the selective integrin inhibitor cilengitide combined with standard chemoradiotherapy in patients with newly diagnosed glioblastoma and an unmethylated MGMT promoter. METHODS: Overall, 265 patients were randomized (1:1:1) to standard cilengitide (2000 mg 2×/wk; n = 88), intensive cilengitide (2000 mg 5×/wk during wk 1-6, thereafter 2×/wk; n = 88), or a control arm (chemoradiotherapy alone; n = 89). Cilengitide was administered intravenously in combination with daily temozolomide (TMZ) and concomitant radiotherapy (RT; wk 1-6), followed by TMZ maintenance therapy (TMZ/RT→TMZ). The primary endpoint was overall survival; secondary endpoints included progression-free survival, pharmacokinetics, and safety and tolerability. RESULTS: Median overall survival was 16.3 months in the standard cilengitide arm (hazard ratio [HR], 0.686; 95% CI: 0.484, 0.972; P = .032) and 14.5 months in the intensive cilengitide arm (HR, 0.858; 95% CI: 0.612, 1.204; P = .3771) versus 13.4 months in the control arm. Median progression-free survival assessed per independent review committee was 5.6 months (HR, 0.822; 95% CI: 0.595, 1.134) and 5.9 months (HR, 0.794; 95% CI: 0.575, 1.096) in the standard and intensive cilengitide arms, respectively, versus 4.1 months in the control arm. Cilengitide was well tolerated. CONCLUSIONS: Standard and intensive cilengitide dose regimens were well tolerated in combination with TMZ/RT→TMZ. Inconsistent overall survival and progression-free survival outcomes and a limited sample size did not allow firm conclusions regarding clinical efficacy in this exploratory phase II study.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Addition of a 50 mM mixture of l-arginine and l-glutamic acid (RE) is extensively used to improve protein solubility and stability, although the origin of the effect is not well understood. We present Small Angle X-ray Scattering (SAXS) and Nuclear Magnetic Resonance (NMR) results showing that RE induces protein compaction by collapsing flexible loops on the protein core. This is suggested to be a general mechanism preventing aggregation and improving resistance to proteases and to originate from the polyelectrolyte nature of RE. Molecular polyelectrolyte mixtures are expected to display long range correlation effects according to dressed interaction site theory. We hypothesize that perturbation of the RE solution by dissolved proteins is proportional to the volume occupied by the protein. As a consequence, loop collapse, minimizing the effective protein volume, is favored in the presence of RE.