981 resultados para Astronomical optics


Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report and analyze the halting of the fuse effect propagation in optical fiber microwires. The increase of the mode field diameter in the tapered region decreases the optical intensity resulting in the extinction of the fuse effect. This fiber element presents a low insertion loss and can be introduced in the optical network in order to protect the active equipment from the damage caused by the fuse effect.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report and analyze the halting of the fuse effect propagation in optical fiber microwires. The increase of the mode field diameter in the tapered region decreases the optical intensity resulting in the extinction of the fuse effect. This fiber element presents a low insertion loss and can be introduced in the optical network in order to protect the active equipment from the damage caused by the fuse effect. (C) 2012 Optical Society of America

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report on a simple method to obtain surface gratings using a Michelson interferometer and femtosecond laser radiation. In the optical setup used, two parallel laser beams are generated using a beam splitter and then focused using the same focusing lens. An interference pattern is created in the focal plane of the focusing lens, which can be used to pattern the surface of materials. The main advantage of this method is that the optical paths difference of the interfering beams is independent of the distance between the beams. As a result, the fringes period can be varied without a need for major realignment of the optical system and the time coincidence between the interfering beams can be easily monitored. The potential of the method was demonstrated by patterning surface gratings with different periods on titanium surfaces in air.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report the fabrication of planar sub-micron gratings in silicon with a period of 720 nm using a modified Michelson interferometer and femtosecond laser radiation. The gratings consist of alternated stripes of laser ablated and unmodified material. Ablated stripes are bordered by parallel ridges which protrude above the unmodified material. In the regions where ridges are formed, the laser radiation intensity is not sufficient to cause ablation. Nevertheless, melting and a significant temperature increase are expected, and ridges may be formed due to expansion of silicon during resolidification or silicon oxidation. These conclusions are consistent with the evolution of the stripes morphology as a function of the distance from the center of the grating.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho de Projeto para obtenção do grau de Mestre em Engenharia na Área de Especialização em Vias de Comunicação e Transportes

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho realizado sob orientação do Prof. António Brandão Moniz para a disciplina “Factores Sociais da Inovação” do Mestrado Engenharia Informática realizado na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa (Portugal).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The rheological and structural characteristics of acetoxypropylcellulose (APC) nematic melt are studied at shear rates ranging from 10 s(-1) to 1000 s(-1) which are relevant to extrusion based processes. APC shows a monotonic shear thinning behavior over the range of shear rates tested. The negative extrudate-swell shows a minimum when a critical shear rate (gamma) over dot(c) is reached. For shear rates smaller than (gamma) over dot(c), the flow-induced texture consists of two set of bands aligned parallel and normal to the flow direction. At shear rates larger than (gamma) over dot(c), the flow induced texture is reminiscent of a 2 fluids structure. Close to the shearing walls, domains elongated along the flow direction and stacked along the vorticity are imaged with POM, whereas SALS patterns indicate that the bulk of the sheared APC is made of elliptical domains oriented along the vorticity. No full nematic alignment is achieved at the largest shear rate tested. Below (gamma) over dot(c), the stress relaxation is described by a stretched exponential. Above (gamma) over dot(c), the stress relaxation is described by a fast and a slow process. The latter coincides with the growth of normal bands thicknesses, as the APC texture after flow cessation consists of two types of bands with parallel and normal orientations relative to the flow direction. Both bands thicknesses do not depend on the applied shear rate, in contrast to their orientation. (C) 2015 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUMO - No contexto económico actual, os custos pelos acidentes devem ser tidos em conta por todos os gestores das organizações, com especial destaque ao sector da saúde. Assim a análise económica deste estudo visa alertar para o impacto económico dos acidentes de trabalho em contexto hospitalar e sensibilizar os gestores para a análise do custo-beneficio da prevenção. Existem custos facilmente constatáveis, tais como, o tempo perdido no dia do acidente, quer pelo sinistrado quer pelos colegas de trabalho que o assistem, as despesas de uma ida ao serviço de urgência, a paragem da produção, a formação de mão-de-obra alternativa, a substituição dos trabalhadores, o pagamento de horas extras, o restabelecimento dos trabalhadores, os salários pagos aos trabalhadores sinistrados, as despesas administrativas e o aumento do prémio do seguro, entre outros. Existem outros custos que não são tão evidentes e por conseguinte, dificilmente quantificáveis, como é o caso da deterioração da imagem da empresa e o impacto sentimental que estes provocam nos colegas de trabalho que se traduz em quebras de produtividade. A análise económica foi realizada tendo em conta a definição de várias variáveis, de várias rubricas de custos pertencentes ao mesmo domínio. Neste projecto pretende-se analisar o custo global da sinistralidade segundo três ópticas distintas. A óptica da variabilidade, da imputabilidade e da responsabilidade, de forma a ser possível obter o custo marginal devido à ocorrência de um novo acidente, o montante de custos assumidos pelas empresas e os custos unitários segundo a natureza e a localização da lesão. ---------- ABSTRACT - In the current economic context, the costs originated by labour accidents must be taken in account by all the managers of the organisations, in this case, especially by the health sector. Thus, the economic analysis of this study case aims, to alert for the economic impact of the industrial accidents and motivate the managers for the analysis of the cost-benefit for prevention. There are kinds of costs easily quantified such as, the lost time in the day of the accident, expenses in the urgencies service, production interruption, workforce formation, workers’ substitution, extra work payment, employers’ healing, wages paid to injured workers’, administrative expenses and a biggest insurers’’ prime, among other things. The economic analysis of the labour injuries, was developed taking in account the definition of some variables, of some cost categories which belong to same domain. In this project we pretend to analyse the global cost labour injuries according to three distinct optics: variability, imputability and responsibility. Thus, it became possible to get the cost due to an occurrence of a new accident, the unitary sum of costs assumed by the companies and costs according to nature and the localisation of the injury.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Part of the optical clearing study in biological tissues concerns the determination of the diffusion characteristics of water and optical clearing agents in the subject tissue. Such information is sufficient to characterize the time dependence of the optical clearing mechanisms—tissue dehydration and refractive index (RI) matching. We have used a simple method based on collimated optical transmittance measurements made from muscle samples under treatment with aqueous solutions containing different concentrations of ethylene glycol (EG), to determine the diffusion time values of water and EG in skeletal muscle. By representing the estimated mean diffusion time values from each treatment as a function of agent concentration in solution, we could identify the real diffusion times for water and agent. These values allowed for the calculation of the correspondent diffusion coefficients for those fluids. With these results, we have demonstrated that the dehydration mechanism is the one that dominates optical clearing in the first minute of treatment, while the RI matching takes over the optical clearing operations after that and remains for a longer time of treatment up to about 10 min, as we could see for EG and thin tissue samples of 0.5 mm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is known that the fibrous structure of muscle causes light scattering. This phenomenon occurs due to the refractive index discontinuities located between muscle fibers and interstitial fluid. To study the possibility of reducing light scattering inside muscle, we consider its spectral transmittance evolution during an immersion treatment with an optical clearing solution containing ethanol, glycerol, and distilled water. Our methodology consists of registering spectral transmittance of muscle samples while immersed in that solution. With the spectral data collected, we represent the transmittance evolution for some wavelengths during the treatment applied. Additionally, we study the variations that the treatment has caused on the samples regarding tissue refractive index and mass. By analyzing microscopic photographs of tissue cross section, we can also verify changes in the internal arrangement of muscle fibers caused by the immersion treatment. Due to a mathematical model that we develop, we can explain the variations observed in the studied parameters and estimate the amount of optical clearing agent that has diffused into the tissue samples during the immersion treatment. At the end of the study, we observe and explain the improvement in tissue spectral transmittance, which is approximately 65% after 20 min.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Microlaparoscopy represents the development of endoscopic surgery towards a minimally invasive surgical procedure. The advantages include fewer surgical complications, faster return to daily activities, more comfortable postoperative recovery, and satisfactory aesthetic results. The possibility of performing surgery under sedation may result in shorter hospitalization, lower hospital costs, and easier anesthetic procedures. The authors report their preliminary experience with the use of microlaparoscopy, using optics and 2mm instruments, as well as a review of the literature since the introduction of this new technique. The report of these 16 cases demonstrates that microlaparoscopy is a feasible technique with satisfactory results. On the other hand, this new technique requires precise indications and a training period for the development of the skills necessary for performing these surgeries.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

2,4,5-Triaryl-imidazoles are versatile compounds with application in medicine, due to their biological activity, and materials sciences, for their interesting optical properties. These properties can be tuned by careful selection of substituents at positions 2, 4 and 5: replacement of the aryl group by an heterocyclic group results in larger π-conjugated systems with improved optical properties for application in nonlinear optics, OLEDs, DNA intercalators, and chemosensors. Moreover, it is expected that introducing more conjugation and rigidity into the resulting system will further improve its properties. The development of chromo/fluorescent probes that are capable of detecting ions with high sensitivity and selectivity in aqueous media is currently a topic of strong interest and the design of heteroditopic receptors that contain two or more different binding sites for the simultaneous complexation of cationic and anionic guests is a emerging field of supramolecular chemistry. In this communication, we report the synthesis of new phenanthroimidazoles substituted at position 2 with arylthienyl or arylfuryl moieties possessing substituents of different electronic character, in order to tune the chromo/fluoro response in the presence of relevant anions and metal cations. Their photophysical properties and chemosensory ability were studied in acetonitrile and mixtures of acetonitrile and water, and selective detection of cyanide was achieved in aqueous mixtures for some of the derivatives.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In recent years the research of sensors with good sensitivity and good selectivity in aqueous medium has been of great interest. Chemosensors soluble in aqueous media are very interesting, because of the importance in revealing a number of biological processes, disease states and environmental pollutions. 2,4,5-Triaryl-imidazoles are versatile compounds with application in medicine, due to their biological activity, and materials sciences, for their interesting optical properties. These properties can be tuned by careful selection of substituents at positions 2, 4 and 5: replacement of the aryl group by a heterocyclic group results in larger π-conjugated systems with improved optical properties for application in nonlinear optics, OLEDs, DNA intercalators, and chemosensors. In this communication, we report the synthesis of new phenanthroimidazoles, substituted at position 2 with (hetero)aryl groups of different electronic character, in order to evaluate their photophysical properties and chemosensory ability. The new derivatives were characterized by the usual techniques and a detailed photophysical study was undertaken. The evaluation of the compounds as fluorimetric chemosensors was carried out by performing titrations in acetonitrile and acetonitrile/water in the presence of relevant organic and inorganic anions, and of alkaline, alkaline-earth and transition metal cations.