982 resultados para Apical Membrane Antigen-1
Resumo:
In order to evaluate the potential allergenicity of Blomia tropicalis (Bt) antigen, IgE production of both specific and non-specific for Bt antigen was monitored in BALB/c mice after exposure to the antigen by nasal route. It was evidenced that B. tropicalis contains a functional allergen in its components. The allergenic components, however, when administered intranasally without any adjuvant, did not function to induce IgE response within a short period. On the other hand, intranasal inoculation of Bt antigens augmented serum IgE responses in mice pretreated by a subcutaneous priming injection of the same antigens. Inoculation of Bt antigen without subcutaneous priming injections induced IgE antibody production only when the antigen was continuously administered for a long period of over 24 weeks. Even when the priming injection was absent, the Bt antigen inoculated with cholera toxin (CT) as a mucosal adjuvant also significantly augmented the Bt antigen-specific IgE responses depending on the dose of CT co-administered. The present study also demonstrated that Bt antigen/CT-inoculated mice showed increased non-specific serum IgE level and peripheral blood eosinophil rates without noticeable elevations of the total leukocyte counts. The immunoblot analysis demonstrated 5 main antigenic components reactive to IgE antibodies induced. These components at about 44-64 kDa position were considered to be an important candidate antigen for diagnosis of the mite-related allergy.
Resumo:
This work presents the development of a low cost sensor device for the diagnosis of breast cancer in point-of-care, made with new synthetic biomimetic materials inside plasticized poly(vinyl chloride), PVC, membranes, for subsequent potentiometric detection. This concept was applied to target a conventional biomarker in breast cancer: Breast Cancer Antigen (CA15-3). The new biomimetic material was obtained by molecularly-imprinted technology. In this, a plastic antibody was obtained by polymerizing around the biomarker that acted as an obstacle to the growth of the polymeric matrix. The imprinted polymer was specifically synthetized by electropolymerization on an FTO conductive glass, by using cyclic voltammetry, including 40 cycles within -0.2 and 1.0 V. The reaction used for the polymerization included monomer (pyrrol, 5.0×10-3 mol/L) and protein (CA15-3, 100U/mL), all prepared in phosphate buffer saline (PBS), with a pH of 7.2 and 1% of ethylene glycol. The biomarker was removed from the imprinted sites by proteolytic action of proteinase K. The biomimetic material was employed in the construction of potentiometric sensors and tested with regard to its affinity and selectivity for binding CA15-3, by checking the analytical performance of the obtained electrodes. For this purpose, the biomimetic material was dispersed in plasticized PVC membranes, including or not a lipophilic ionic additive, and applied on a solid conductive support of graphite. The analytical behaviour was evaluated in buffer and in synthetic serum, with regard to linear range, limit of detection, repeatability, and reproducibility. This antibody-like material was tested in synthetic serum, and good results were obtained. The best devices were able to detect 5 times less CA15-3 than that required in clinical use. Selectivity assays were also performed, showing that the various serum components did not interfere with this biomarker. Overall, the potentiometric-based methods showed several advantages compared to other methods reported in the literature. The analytical process was simple, providing fast responses for a reduced amount of analyte, with low cost and feasible miniaturization. It also allowed the detection of a wide range of concentrations, diminishing the required efforts in previous sample pre-treating stages.
Resumo:
Previous experiences have demonstrated the same ABO system and P system antigens in A. lumbricoides extracts and in their hosts. The aim was to show the behavior of an A. lumbricoides extract from an O Group patient against monoclonal antibodies of different specificities. Agglutination Inhibition Tests were carried out facing the extract against monoclonal antibodies (anti A 2.23; anti B 2.54; anti B 2.62; anti AB 2.39 and anti H 2.72) in optimal concentrations. Suspensions of O Group fresh red cells were used as revealing system. The extract only inhibited the agglutination of anti H 2.72 with O erythrocytes. The semiquantitative Agglutination Inhibition Test of the extract was made against two series of anti H 2.72 dilutions by using O Group fresh red cells as revealing system. A difference of five dilutions between the titers of both series has been observed and the presence of H Antigen in the extract has been significantly confirmed. The fact that the extract did not inhibit the agglutination against anti A, anti B and anti AB has corroborated our previous observations about absence of A and B epitopes in A. lumbricoides extracts from O Group patients. The results of the preceding studies and this experience have demonstrated the membrane glycoconjugated importance in A. lumbricoides. They could be involved in molecular mimicry for this parasite.
Resumo:
The present work evaluated the diagnostic accuracy of detection of Dengue NS1 antigen employing two NS1 assays, an immunochromatographic assay and ELISA, in the diagnostic routine of Public Health laboratories. The results obtained with NS1 assay were compared with virus isolation and, in a subpopulation of cases, they were compared with the IgM-ELISA results obtained with convalescent samples. A total of 2,321 sera samples were analyzed by one of two NS1 techniques from March to October 2009. The samples were divided into five groups: groups I, II and III included samples tested by NS1 and virus isolation, and groups IV and V included patients with a first sample tested by NS1 and a second sample tested by IgM-ELISA. Sensitivity, specificity, positive and negative predictive values, Kappa Index and Kappa Concordance were calculated. The results showed that NS1 testing in groups I, II and III had high sensitivity (98.0%, 99.5% and 99.3%), and predictive values and Kappa index between 0.9 - 1.0. Groups IV and V only had Kappa Concordance calculated, since the samples were analyzed according to the presence of NS1 antigen or IgM antibody. Concordance of 92.1% was observed when comparing the results of NS1-negative samples with IgM-ELISA. Based on the findings, it is possible to suggest that the tests for NS1 detection may be important tools for monitoring the introduction and spread of Dengue serotypes.
Resumo:
In this study, we report on the safety and skin delayed-type hypersensitivity (DTH), responses of the Leishmania donovani whole cell sonicate antigen delivered in conjunction with alum-BCG (AlBCG), Montanide ISA 720 (MISA) or Monophosphoryl lipid A (MPLA) in groups of vervet monkeys. Following three intradermal injections of the inoculums on days 0, 28 and 42, safety and DTH responses were assessed. Preliminary tumor necrosis factor alpha (TNF-α) and interferon gamma (IFN-γ) levels were also measured and these were compared with DTH. Only those animals immunized with alum-BCG reacted adversely to the inoculum by producing ulcerative erythematous skin indurations. Non-parametric analysis of variance followed by a post-test showed significantly higher DTH responses in the MISA+Ag group compared with other immunized groups (p < 0.001). The MPLA+Ag group indicated significantly lower DTH responses to the sonicate antigen compared with the AlBCG+Ag group. There was a significant correlation between the DTH and cytokine responses (p < 0.0001). Based on this study we conclude that Leishmania donovani sonicate antigen containing MISA 720 is safe and is associated with a strong DTH reaction following immunization.
Resumo:
The objective of this study is to identify subtypes of Human Immunodeficiency Virus type 1 (HIV-1) and to analyze the presence of mutations associated to antiretroviral resistance in the protease (PR) and reverse transcriptase (RT) regions from 48 HIV-1 positive treatment naïve patients from an outpatient clinic in Maringá, Paraná, Brazil. Sequencing was conducted using PR, partial RT and group-specific antigen gene (gag) nested PCR products from retrotranscribed RNA. Transmitted resistance was determined according to the Surveillance Drug Resistance Mutation List (SDRM) algorithm. Phylogenetic and SimPlot analysis of concatenated genetic segments classified sequences as subtype B 19/48 (39.6%), subtype C 12/48 (25%), subtype F 4/48 (8.3%), with 13/48 (27.1%) recombinant forms. Most recombinant forms were B mosaics (B/F 12.5%, B/C 10.4%), with one C/F (2.1%) and one complex B/C/F mosaic (2.1%). Low levels of transmitted resistance were found in this study, 2/48 (2.1% to NRTIs and 2.1% for PI). This preliminary data may subsidize the monitoring of the HIV evolution in the region.
Resumo:
SUMMARY The aim of this study was to evaluate six different antigenic fractions from Strongyloides venezuelensis parasitic females for the immunodiagnosis of human strongyloidiasis. Soluble and membrane fractions from S. venezuelensis parasitic females were prepared in phosphate-buffered saline (SSF and SMF, respectively), Tris-HCl (TSF and TMF, respectively), and an alkaline buffer (ASF and AMF, respectively). Serum samples obtained from patients with strongyloidiasis or, other parasitic diseases, and healthy individuals were analyzed by enzyme-linked immunosorbent assay (ELISA). Soluble fractions SSF, TSF, and ASF showed 85.0%, 75.0%, and 80.0% sensitivity and 93.1%, 93.1%, and 87.5% specificity, respectively. Membrane fractions SMF, TMF, and AMF showed 80.0%, 75.0%, and 85.0% sensitivity, and 95.8%, 90.3%, and 91.7% specificity, respectively. In conclusion, the present results suggest that the fractions obtained from parasitic females, especially the SSF and SMF, could be used as alternative antigen sources in the serodiagnosis of human strongyloidiasis.
Resumo:
J Biol Inorg Chem (2008) 13:1321–1333 DOI 10.1007/s00775-008-0416-1
Resumo:
J Biol Inorg Chem. 2008 Jun;13(5):779-87. doi: 10.1007/s00775-008-0365-8
Resumo:
Three concentrations of Leishmania mexicana amazonensis sonicated whole promastigote antigen (30, 9.6 and 3 ug N in 0.1 ml) wereprepared and 0.1 ml of each inoculated intradermally intopatients who live in one endemic leishmaniasis region in Brazil. Patients were divided into groups with active cutaneous leishmaniasis (ACL), healed cutaneous leishmaniasis (HCL), mucosal leishmaniasis (ML), and Controls (C). Skin reactions were recorded by measuring induration 48 hours after inoculation. Skin tests using 9.6 ugN/0.1 mlyielded the best diagnostic resultssince 97% of 30 patients with active lesions (cutaneous or mucosal) and 83% with HCL showed reactions of 5 mm orgreater as compared with 4% Controls. Tests using 30ug N/O. 1 ml causedan unacceptable levei of skin reactions with necrosis (10% of ACL patients tested and 17% of HCL, respectively). Tests using 3 ug N/O. 1 ml were less sensitive since only 87% of patients with active lesions and 68% with HCL had reactions of 5mm orgreater. The 3 ug N/O. 1 ml dose was utilized to ask the questions whether skin delayed hypersensitivity decreased with time after the initial lesion and whether mucosal involvement is associated with enhaced hypersensitivity to leishmanial antigen. Decreased delayed hypersensitivity was noted only in those patients who had an initial lesion more than 30 years ago. The mean induration of the reaction in 10 patients with ML was 11.3 mm ± 7.15, in 41 patients with HCL, 9.27 mm ± 6.78 and in 20patients with ACL 10. 7 mm ± 6.10 mm. The percent of patients with 5 mm orgreater induration was ML 80%, HCL 71%, ACL 90%. Thus, we could not confirm an association between enhanced delayed hypersensitivity and mucosal involvement in leishmaniasis.
Resumo:
Antibodies against the Salmonella typhi enterobacterial common antigen (ECA) and the O and H antigens were investigated in sera from healthy male subjects who had been previously vaccinated with the typhoid vaccine. No serological response to ECA was observed. Sera from subjects not previously vaccinated presented titers of ECA hemagglutinins which quantitatively were related to the presence ofH titers, but not to O agglutinins but with no statistical significance. The results are discussed in relation to the possible protective immunological mechanisms in typhoid fever.
Resumo:
In August 1983,85 inhabitants of the municipality of Humaitá, Amazonas State, Brazil were studied to determine the prevalence of antigens to HLA-A, -B, -C and DR. Thirty-eight were sick with malaria due to Plasmodium falciparum. All subjects were examined for splenomegaly, blood parasitaemia and antibodies to malaria. They constituted three groups: 1) 25 subjects native to the Amazon region who had never had malaria; 2) 38 Amazonian subjects who had malaria in the past or currently had an infection; 3) 22 patients with malaria who had acquired the infection in the Amazon Region but came from other regions of Brazil. Blood was taken from each person, the lymphocytes were separated and typed by the test of microlymphocytotoxicity. There was a high frequency of antigens that could not be identified in the groups studied which suggests the existence of a homozygote or phenotype not identified in the population. There was a high frequency of the phenotype Ag(W24) (44.7%) in group 2 when compared with group 1 (32%) or group 3 (9%). Also the individuals in group 2 showed an elevated frequency of antigen DR(4)80%) when compared with group 1 (36.6%) or group 3 (16.6%). These observations suggest the possibility of a genetic susceptibility to malaria among Amazonian residents and indicate a necessity for more extensive studies of the frequency of HLA antigens among inhabitants of this endemic malarial zone.
Two competitive enzyme immunoassays for the detection of IgG class antibodies to hepatitis a antigen
Resumo:
Two competitive enzyme immunoassays (EIA) techniques were developed: in the first (COMP-1), test sera were added together with HAV antigen on anti-HAV IgG-coated wells followed by an anti-HA VHRP conjugate; in the second (COMP-2), test sera and anti-HA VHRP conjugate competed for HAV epitopes previously adsorbed to anti-HA V IgG-coated wells. Both procedures used tetramethylbenzidine (TMB) as a substrate. Both competitive tests were shown to be reproducible and suitable for routine diagnosis and research purposes.
Resumo:
Dissertation presented to Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa for obtaining the master degree in Membrane Engineering
Resumo:
Dissertação para obtenção do Grau de Doutor em Sistemas de Bioengenharia