912 resultados para wet storage


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The production of minimally processed fruit has increased significantly in the last few years due to the high nutritional value, convenience and safety of minimally processed fruit. The objective of the present study was to evaluate the effects of the conservation temperature and processing conditions on the quality and shelf-life of minimally processed peaches. The processing procedure consisted of washing, sanitization, peeling and stone removal. To remove the stone, the fruit was cut longitudinally, and three types of products were obtained, including halves, quarters and one-eighth segments. The fruit pieces were immersed in 2% ascorbic acid for 3 min and were packed in rigid polystyrene trays (Meiwa (c) M-54) coated with 14 mu m PVC film (Omnifilm (TM)) (about 200 g per pack). The pieces were stored at 65% RH at 3, 6 or 9 degrees C for 12 days, and were evaluated every four days. The appearance, fresh mass loss, color, O-2 and CO2 concentration, acidity, total soluble solids, total and soluble pectin content and ascorbic acid concentration were measured. Minimally processed peaches stored at 3 degrees C maintained higher quality due to control of ripening and senescence Moreover, an interaction effect between one-eighth segments and a temperature of 3 degrees C was observed, and fruit with a superior appearance and higher soluble solids content was obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. Evaluate the flexural strength (sigma) and subcritical crack growth (SCG) under cyclic loading of glass-infiltrated alumina-based (IA, In-Ceram Alumina) and zirconia-reinforced (IZ, In-Ceram Zirconia) ceramics, testing the hypothesis that wet environment influences the SCG of both ceramics when submitted to cyclic loading.Methods. Bar-shaped specimens of IA (n = 45) and IZ ( n = 45) were fabricated and loaded in three-point bending (3P) in 37 degrees C artificial saliva (IA(3P) and IZ(3P)) and cyclic fatigued (F) in dry (D) and wet (W) conditions (IA(FD), IA(FW), IZ(FD), IZ(FW)). The initial sigma and the number of cycles to fracture were obtained from 3P and F tests, respectively. Data was examined using Weibull statistics. The SCG behavior was described in terms of crack velocity as a function of maximum stress intensity factor (K(Imax)).Results. The Weibull moduli (m = 8) were similar for both ceramics. The characteristic strength (sigma(0)) of IA and IZ was and 466 MPa 550 MPa, respectively. The wet environment significantly increased the SCG of IZ, whereas a less evident effect was observed for IA. In general, both ceramics were prone to SCG, with crack propagation occurring at K(I) as low as 43-48% of their critical K(I). The highest sigma of IZ should lead to longer lifetimes for similar loading conditions.Significance. Water combined with cyclic loading causes pronounced SCG in IZ and IA materials. The lifetime of dental restorations based on these ceramics is expected to increase by reducing their direct exposure to wet conditions and/or by using high content zirconia ceramics with higher strength. (C) 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study was developed in the 'Laboratorio de Biologia e Criacao de Insetos' (LBCI), 'Faculdade de Ciencias Agrarias e Veterinarias (FCAV), 'Universidade Estadual Paulista' (Unesp), Jaboticabal, SP, with objective of evaluating the pupae storage effect of Cotesia flavipes in low temperature (medium temperature = 2,75[degree]C). The experiment was made up of 13 treatments: fi, 1, 2, 3, 4, 5, 6, 7, 8, 9.10 and 11 masses storage days of pupae in refrigerator temperature and the check was man maintained on 25[plus or minus]2[degree]C and relative humidity of 70[plus or minus]10%. The next generation of parasitoid also was analyzed, maintained to 25[plus or minus]2[degree]C during all development. It was evaluated: period and pupae viability; average number, longevity and adults' sex ratio of the stored generation and period egg-larvae; period and pupae viability: average number, longevity and adults' sex ratio of the next generation. It verified that the pupae storage of C. flavipes in refrigerator temperature for until 5 days does not affect its development and the stored generation, suggesting the utilization possibility of this resource in mass rearing of this insect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The social wasp nests were quantified in three different plant physiognomies (forested Caatinga, shrubby Caatinga, and agricultural systems) to analyze the effect of environmental seasonality and plant physiognomy on the richness, nest abundance, and species composition of social wasps in the region of tropical dry forest of Brazil. The forested Caatinga physiognomy had the greatest richness of species (S = 16), followed by shrubby Caatinga (S 13) and by agricultural system (S = 12). The first axis of detrended correspondence analysis (DCA) explained 67.8% of the variability and shows a gradient of the fauna from agricultural system and shrubby Caatinga to forested Caatinga. In the first axis, wet season scores were much higher than those for the dry season in forested Caatinga. The second axis explained 18.7% of the variability and shows a separation of samples collected during the wet or the dry periods in shrubby Caatinga. This separation was less evident in the agricultural system. Variations in nest abundance were more intense in arbustive caatinga (45% decrease in number of active nests in the dry period), moderate in forested Caatinga (24% decrease in number of active nests in the dry period), and low in agricultural systems (8% decrease in the dry period).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction. Rambutan is a tropical fruit species with recalcitrant seeds. Despite the expansion of exotic fruit cultivation in Brazil, lots of which fruit species, including rambutan, need basic information, especially in relation to propagation and storage of seeds, which are important for genetic improvement studies, maintenance of genetic sources and seedling production. Materials and methods. A completely randomized design was adopted with treatments distributed in a factorial arrangement, 3 x 4, referring to three seed storage conditions [room temperature conditions; a dry chamber with (18 +/- 2) degrees C and 60% relative humidity; and a cold chamber with (10 +/- 2) degrees C and 70% relative humidity] and four storage times ( 0, 7, 14 and 21 d). Each treatment of 10 seeds was replicated five times. Data on seedling emergence, emergence rate, plant height, number of leaves and length of main root were submitted to variance analysis and means were separated using Tukey's test. Correlation analysis between seed moisture and seedling emergence was performed. Results and discussion. Our results indicated that dry chamber conditions promoted the statistically significantly highest seedling emergence after 7 d of storage. Cold chamber conditions promoted an extremely low seedling emergence independently of time. Conclusion. Rambutan seeds can be stored in a dry chamber for 7 d without losing viability; after 14 d of storage the loss of emergence is 60%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cholesteryl ester storage disease (CESD) is a rare disorder of familial incidence characterized by the accumulation of cholesteryl ester and triglycerides in the liver, intestine and bone marrow. Until now only 21 cases have been reported in the literature. We present a 9 months old girl presenting with increased abdominal girth. She had normal liver function tests and increased cholesterol and triglycerides serum levels. The liver biopsy showed many cholesterol cristals seen as needle shaped cristals under polarized light. This is the youngest patient being diagnosed clinically in the literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We discuss the influence of the background thermal bath on the depolarization of electrons in high-energy storage rings, and on the photon emission associated with the spin flip. We focus, in particular, on electrons at CERN LEP. We show that in a certain interval of solid angles the photon emission is enhanced several orders of magnitude because of the presence of the thermal bath. Notwithstanding, the overall depolarization induced by the background thermal bath at LEP conditions is much smaller than the one induced by plain acceleration at zero temperature and can be neglected in practical situations. Eventually we discuss under what conditions the background thermal bath can enhance the overall depolarization by several orders of magnitude.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The present study was performed to investigate the influence of different routes of perfusion on the distribution of the preservation solutions in the lung parenchyma and upper airways. Methods: Pigs were divided into four groups: control (n = 6), pulmonary artery (PA) (n = 6), simultaneous PA + bronchial artery (BA) (n = 8), and retrograde delivery (n = 6). After preparation and cannulation, cardioplegia solution and Euro- Collins solution (ECS) for lung preservation were given simultaneously. After removal of the heart, the double lung bloc was harvested. Following parameters were assessed: total and regional perfusion (dye-labeled microspheres), tissue water content, PA, aorta, left atrial and left ventricular pressures, cardiac output and lung temperature. Results: Our data show that flow of the ECS in lung parenchyma did not reach control values (9.4 ± 1.0 ml/min per g lung wet weight) regardless of the route of delivery (PA 6.3 ± 1.5, PA + BA 4.8 ± 0.9, retrograde 2.7 ± 0.9 ml/min per g lung wet weight). However, flow in the proximal and distal trachea were significantly increased by PA + BA delivery (0.970 ± 0.4, respectively, 0.380 ± 0.2 ml/min per g) in comparison with PA (0.023 ± 0.007, respectively, 0.024 ± 0.070 ml/min per g), retrograde (0.009 ± 0.003, respectively, 0.021 ± 0.006 ml/min per g) and control experiments (0.125 ± 0.0018, respectively, 0.105 ± 0.012 ml/g per min). Similarly the highest flow rates in the right main bronchus were achieved by PA + BA delivery (1.04 ± 0.4 ml/min per g) in comparison with 0.11 ± 0.03 in control, 0.033 ± 0.008 in PA, and 0.019 ± 0.005 ml/min per g in retrograde group. Flows in the left main bronchus were 0.09 ± 0.02 ml/min per g in control, 0.045 ± 0.012 ml/min per g in PA, and 0.027 ± 0.006 ml/min per g in retrograde group. The flow rates were significantly (P = 0.001) increased by PA + BA delivery of the storage solution (0.97 ± 0.3 ml/min per g). Conclusions: Our data show that the distribution of ECS for lung preservation is significantly improved in airway tissues (trachea and bronchi) if a simultaneous PA + BA delivery is used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to gradual resorption of the edentulous ridge bone, removable prostheses often require denture base relines to improve fit and stability. This research evaluated the bond strength between one heat-cured acrylic resin (Lucitone 550®) and two hard chairside reline resins, after two different periods of storage in water (50 h and 30 days). The bond strength was evaluated using a tensile test. The mode of failure, adhesive or cohesive, was also recorded. The results submitted to the Kruskal-Wallis test indicated that the highest tensile strengths were achieved with intact Lucitone 550® denture base resin in both periods of storage in water. After 50 h of storage in water, Duraliner II® reline material exhibited the highest bond strength to the denture base resin. After 30 days of storage in water, Duraliner II® reline resin demonstrated a significant reduction in adhesion, showing lower tensile bond strength than Kooliner® material. Both hard chairside reline materials failed adhesively across Lucitone 550® denture base resin, in both periods of time. © 1999 Blackwell Science Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives of this study were to verify the effects of wet suits (WS) on the performance during 1500m swimming (V1500), on the velocity corresponding to the anaerobic threshold (VAT) and on the drag force (AD) as well as its coefficient (Cx). 19 swimmers randomly completed the following protocols on different days (with and without WS): 1) maximal performance of 1500m swimming; 2) VAT in field test, with fixed concentration of blood lactate (4 mM) and 3) determination of hydrodynamic indices (AD and Cx). The results demonstrated significant differences (p < 0.05) in the VAT (1.27±0.09; 1.21±0.06 m.s-1), and in the V1500 (1.21±0.08; 1.17±0.08 m.s-1), with and without WS, respectively. However the AD, and its Cx did not present significant differences (p>0.05) for the respective maximal speeds of swimming. In summary, we can conclude that WS allows swimmers to reach greater speeds in both, long- and short-course swims. This improvement can be related to the decrease of the AD, since with higher speeds (with WS) the subjects presented the same resistance, as they did when compared to speeds without a WS. Moreover, these data suggest that the methodology used in this study to determine the Cx is unable to detect the improvement caused by WS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Several studies have shown a reduction in enamel bond strengths when the bonding procedure is carried out immediately after vital bleaching with peroxides. This reduction in bond strengths has become a concern in cosmetic dentistry with the introduction of new in-office and waiting-room bleaching techniques. The aim of this in vitro study was to evaluate the effect of three bleaching regimens: 35% hydrogen peroxide (HP), 35% carbamide peroxide (CP), and 10% CP, on dentin bond strengths. Materials and Methods: One hundred and twenty fresh bovine incisors were used in this study. The labial surface of each tooth was ground flat to expose dentin and was subsequently polished with 600-grit wet silicon carbide paper. The remaining dentin thickness was monitored and kept at an average of 2 mm. The teeth were randomly assigned to four bleaching regimens (n = 30): (A) control, no bleaching treatment; (B) 35% HP for 30 minutes; (C) 35% CP for 30 minutes; and (D) 10% CP for 6 hours. For each group, half of the specimens (n = 15) were bonded with Single Bond/Z100 immediately after the bleaching treatment, whereas the other half was bonded after the specimens were stored for 1 week in artificial saliva at 37°C. The specimens were fractured in shear using an Instron machine. Results: For the groups bonded immediately after bleaching, one-way analysis of variance (ANOVA) followed by the Duncan's post hoc test revealed a statistically significant reduction in bond strengths in a range from 71% to 76%. For the groups bonded at 1 week, one-way ANOVA showed that group B (35% HP for 30 min) resulted in the highest bond strengths, whereas 10% CP resulted in the lowest bond strengths. Student's t-test showed that delayed bonding resulted in a significant increase in bond strengths for groups B (35% HP) and C (35% CP); whereas the group bleached with 10% CP (group D) remained in the same range obtained for immediate bonding. Storage in artificial saliva also affected the control group, reducing its bond strengths to 53% of the original. ©2000 BC Decker Inc.