939 resultados para weld toe notch


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The machining of super alloys resistant to high temperatures such as nickel alloys, inconel 718 specifically, is a very difficult job to obtain improvements in the process, due to the difficulty of machining at high cutting speeds, the use of these alloys in industries showed great developments in recent years, its application in aeronautical industry spread being used in vane turbo, compressor parts, props and set elements. The automotive, chemical, medical and others also took advantage of the great features of inconel 718 and has used the material. The high temperature resistant alloys have high machining difficulty, a fact that is associated with high cutting forces generated during machining which result in high temperatures. High levels of temperatures can cause deterioration of the cutting edge, with subsequent deformation or breakage, wear most common obtained in machining such materials are flank wear the formation of built-up edge for cutting and notch wear. The experimental part of the work consists in machining of nickel-based alloy Inconel 718 heat treated for hardness, using a tool based ceramic silicon nitride Sandvik (Si3N4) in order to compare the best results obtained in the master's thesis of SANTOS (2010) who used a tool ceramics also the basis of silicon nitride which was developed in the doctoral thesis of SOUZA (2005). Assays were performed on a CNC lathe and was noted for each cutting edge results obtained. Tests were made starting from an initial condition of the tool with cutting speed of 200 m/min, feed 0.5 mm and 0.5 mm depth of cut was reduced cutting speed for the subsequent tests with the same conditions of feed and depth of cut. The tool presented wear instant under two 200 m/min and 100 m/min, premature rupture of 50 m/min and finally cut provided with difficulty... (Complete abstract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work was to evaluate the corrosion resistance of AuPdAgIn alloy, submitted to laser beam welding, in 0.9% NaCl solution, using electrochemical techniques. Measures of the open circuit potential (OCP) versus time were applied to electrochemical experiments, as well as potentiodynamic direct scanning (PDS) and electrochemical impedance spectroscopy (EIS) on AuPdAgIn alloy, submitted to laser beam welding in 0.9% NaCl solution. Some differences observed in the microstructure can explain the results obtained for corrosion potential, Ecorr, and corrosion resistance, Rp. EIS spectra have been characterized by distorted capacitive components, presenting linear impedance at low frequencies, including a non-uniform diffusion. The area of the laser weld presented corrosion potential slightly superior when compared to the one of the base metal. The impedance results suggest the best resistant corrosion behavior for laser weld than base metal region. This welding process is a promising alternative to dental prostheses casting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Zootecnia - FCAV

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work focuses on a study on the fatigue behavior of a microalloyed steel API 5L X70, used in pipes lines to transport oil and gas. These types of steels have excellent mechanical resistance values and ductility and therefore increased their study driven by increased demand for oil and especially natural gas, which consequently raises the need to build new pipelines to transport these products. The oil extraction units, composed of the risers (pipelines connecting the oil well to the ship), are dimensioned to remain installed for periods of 20 to 30 years in the marine environment, a hostile environment for high pressure, corrosion, low temperatures and the stresses caused by the movement of water and tides. For analysis, the S-N (stress versus number of cycles) curves were obtained from data collected from bodies-of-proof cylindrical longitudinal, transverse and that one removed from the weld area of the pipe, tested in accordance with ASTM E466. Tensile tests were performed for characterizing the mechanical properties of the samples and welded joints, concluded that the values meet the specifications of the standard API 5L. To characterize microstructural material, also metallographic analysis was made of regions of the base metal and the HAZ. The results of fatigue tests demonstrated a higher life for the specimens removed from the longitudinal direction the pipe, followed by those in the transverse direction and, finally, the welded joint. The origins of the fatigue cracks were determined by scanning electron microscopy (SEM)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: to radiographically evaluate the distance between mandibular lingula and the exact spot where buccal and lingual cortical bone plates merge in the mandibular ramus. Materials and Methods: 54 dry mandibles, divided into 3 subgroups (SG1: dentate, SG2: partially dentate and SG3: edentulous) were used in this study. Lingula position was marked with a metallic sphere and radiographs were taken. The distance between mandibular notch and lingula (I/L) and the distance between mandibular lingula and cortical bone plates fusion (L/FC) were measured. Statistical analysis was applied to the values obtained. Results: mean values for L/FC were 8,18mm, 7,30mm and 8,98mm for SG1, SG2 e SG3 respectively. Moreover, mean values for I/L were 14,02mm, 13,90mm and 12,34mm for SG1, SG 2 and SG3 respectively. The results also showed that cortical bone plates fusion took place in half I/L distance in 28,57% of the mandibles in SG1, in 46,67% of the mandibles in SG2 and in 9,09% of the pieces in SG3. Conclusions: there were no statistically significant differences in the height where cortical bone plates took place in all 3 subgroups. In SG3, the correlation between the mean value for L/FC and the mean value for I/L suggests a reduction in bone density and bone mass, which can correlate to the evaluation of older mandibles in this subgroup.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dislocated subcondylar fractures often require open reduction and internal fixation. This treatment modality results in better anatomy, early function, and facilitated physical therapy. Ideal stable fixation is obtained by use of two miniplates to control the tension zone in the sigmoid notch area and stabilize the posterior border region or, if there is not enough space, one stronger plate. That is most frequently achieved through extraoral approaches. Recently new instruments have facilitated the use of an intraoral approach, which is used usually with the aid of an endoscope. However, it is possible to perform the procedure without the endoscope if proper instruments and clinical mirrors for checking the posterior border reduction and fixation are used. A case of reduction and fixation of a medially dislocated condylar fracture is presented and discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The osteomas are benign rare neoplasms, generally asymptomatic which are characterized by the proliferation of a compact or spongy bone. When they are situated in the maxillofacial area, they affect mainly the mandible, the frontal bone and the paranasal sinus. We have described the case of a female caucasian patient who presented an increased volume in the posterior region of the oral vestibule on the left side. During the clinical examination an oral lesion was observed in the region of the left ramus of mandible. This lesion was motionless, consistent, and painless when palpated. In the image obtained from the computed tomography cone–beam (CBCT), we could observe an hyperdense, cylindrical region, with well defined borders, located in the medial surface of the left ramus of mandible, right below the mandibular notch. Based on clinical data and in the obtained images, we could confirm the presence of the peripheral osteoma in the left side of the ramus of mandible region.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEIS

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Ciência e Tecnologia de Materiais - FC