921 resultados para waste heat recovery system
Resumo:
Epidemic protocols are a bio-inspired communication and computation paradigm for extreme-scale network system based on randomized communication. The protocols rely on a membership service to build decentralized and random overlay topologies. In a weakly connected overlay topology, a naive mechanism of membership protocols can break the connectivity, thus impairing the accuracy of the application. This work investigates the factors in membership protocols that cause the loss of global connectivity and introduces the first topology connectivity recovery mechanism. The mechanism is integrated into the Expander Membership Protocol, which is then evaluated against other membership protocols. The analysis shows that the proposed connectivity recovery mechanism is effective in preserving topology connectivity and also helps to improve the application performance in terms of convergence speed.
Resumo:
A general circulation model of intermediate complexity with an idealized Earth-like aquaplanet setup is used to study the impact of changes in the oceanic heat transport on the global atmospheric circulation. Focus is on the atmospheric mean meridional circulation and global thermodynamic properties. The atmosphere counterbalances to a large extent the imposed changes in the oceanic heat transport, but, nonetheless, significant modifications to the atmospheric general circulation are found. Increasing the strength of the oceanic heat transport up to 2.5 PW leads to an increase in the global mean near-surface temperature and to a decrease in its equator-to-pole gradient. For stronger transports, the gradient is reduced further, but the global mean remains approximately constant. This is linked to a cooling and a reversal of the temperature gradient in the tropics. Additionally, a stronger oceanic heat transport leads to a decline in the intensity and a poleward shift of the maxima of both the Hadley and Ferrel cells. Changes in zonal mean diabatic heating and friction impact the properties of the Hadley cell, while the behavior of the Ferrel cell is mostly controlled by friction. The efficiency of the climate machine, the intensity of the Lorenz energy cycle and the material entropy production of the system decline with increased oceanic heat transport. This suggests that the climate system becomes less efficient and turns into a state of reduced entropy production as the enhanced oceanic transport performs a stronger large-scale mixing between geophysical fluids with different temperatures, thus reducing the available energy in the climate system and bringing it closer to a state of thermal equilibrium.
Resumo:
We present one of the first studies of the use of Distributed Temperature Sensing (DTS) along fibre-optic cables to purposely monitor spatial and temporal variations in ground surface temperature (GST) and soil temperature, and provide an estimate of the heat flux at the base of the canopy layer and in the soil. Our field site was at a groundwater-fed wet meadow in the Netherlands covered by a canopy layer (between 0-0.5 m thickness) consisting of grass and sedges. At this site, we ran a single cable across the surface in parallel 40 m sections spaced by 2 m, to create a 40×40 m monitoring field for GST. We also buried a short length (≈10 m) of cable to depth of 0.1±0.02 m to measure soil temperature. We monitored the temperature along the entire cable continuously over a two-day period and captured the diurnal course of GST, and how it was affected by rainfall and canopy structure. The diurnal GST range, as observed by the DTS system, varied between 20.94 and 35.08◦C; precipitation events acted to suppress the range of GST. The spatial distribution of GST correlated with canopy vegetation height during both day and night. Using estimates of thermal inertia, combined with a harmonic analysis of GST and soil temperature, substrate and soil-heat fluxes were determined. Our observations demonstrate how the use of DTS shows great promise in better characterising area-average substrate/soil heat flux, their spatiotemporal variability, and how this variability is affected by canopy structure. The DTS system is able to provide a much richer data set than could be obtained from point temperature sensors. Furthermore, substrate heat fluxes derived from GST measurements may be able to provide improved closure of the land surface energy balance in micrometeorological field studies. This will enhance our understanding of how hydrometeorological processes interact with near-surface heat fluxes.
Resumo:
This special volume offers a collection of papers that examine challenges and solutions where water meets complex, intersections with women, waste, wisdom or wealth. This unique array of articles offer readers of the Journal of Cleaner Production multidisciplinary views of water issues involving physical and structural perspectives, as well as political, social, cultural and increasingly serious environmental challenges. By building upon extensive literature reviews along with data collected through empirical study and real world observations, the authors effectively present valuable insights into the depth and nature of many of the problems but also present a well-developed array of recommendations, based upon successful projects and programs, world-wide. Among the recommendations are proposals for policies, approaches and regulations that provide system enhancements to prevent pollution and contamination and ideas to monitor and regulate water consumption. This international collection includes studies from 15 countries, documented and written by an equal number of female and male authors.
Resumo:
Excavation west of Wivelsfield, East Sussex, revealed part of an early Romano-British settlement. One of the round-houses may have had a non-domestic, possibly ritual, function. The settlement appears to have been subsequently incorporated within a rectilinear arrangement of field/enclosure ditches. Along the edge of one of these ditches were built a series of features interpreted as ovens, of varying form and likely use, from which charred waste from cereal processing and charcoal from coppiced woodland were recovered.
Resumo:
A key issue in UK railway history is whether the railway system was an efficient response to the traffic requirements of the economy. The UK railway system was constructed entirely by private enterprise with minimal state subsidies. This chapter considers whether the railway system was 'over-built' because the government ignored the advice of the Railway Committee of the Board of Trade. The chapter suggests that the system was over-built by about 35 per cent. The causes of this over-building are investigated and are found to be mainly social and political failures arising from distrust between MPs and civil servants and public pressure on local MPs to ensure that their constituencies were well served by railways.
Resumo:
A Regional Climate Model (RegCM3) 10-year (1990-1999) simulation over southwestern South Atlantic Ocean (SAO) is evaluated to assess the mean climatology and the simulation errors of turbulent fluxes over the sea. Moreover, the relationship between these fluxes and the rainfall over some cyclogenetic areas is also analyzed. The RegCM3 results are validated using some reanalyses datasets (ERA40, R2, GPCP and WHOI). The summer and winter spatial patterns of latent and sensible heat fluxes simulated by the RegCM3 are in agreement with the reanalyses (WHOI, R2 and ERA40). They show large latent heat fluxes exchange in the subtropical SAO and at higher latitudes in the warm waters of Brazil Current. In particular, the magnitude of RegCM3 latent heat fluxes is similar to the WHOI, which is probably related to two factors: (a) small specific humidity bias, and (b) the RegCM3 flux algorithm. In contrast, the RegCM3 presents large overestimation of sensible heat flux, though it simulates well their spatial pattern. This simulation error is associated with the RegCM3 underestimation of the 2-m air temperature. In southwestern SAO, in three known cyclogenetic areas, the reanalyses and the RegCM3 show the existence of different physical mechanisms that control the annual cycles of latent/sensible heating and rainfall. It is shown that over the eastern coast of Uruguay (35A degrees-43A degrees S) and the southeastern coast of Argentina (44A degrees-52A degrees S) the sea-air moisture and heat exchange play an important role to control the annual cycle of precipitation. This does not happen on the south/southeastern coast of Brazil.
Resumo:
The effects of endurance training on PGE(2) levels and upon the maximal activity of hepatic carnitine palmitoyltransferase (CPT) system were studied in rats bearing the Walker 256 carciosarcoma. Animals were randomly assigned to a sedentary control (SC), sedentary tumor-bearing (ST), exercised control (EC), and as an exercised tumor-bearing (ET) group. Trained rats ran on a treadmill (60% VO(2) max) for 60 min/day, 5 days/week, for 8 weeks. We examined the mRNA expression (RT-PCR) and maximal activity (radio-assay) of the carnitine palmitoyltransferase system enzymes (CPT I and CPT II), as well as the gene expression of fatty-acid-binding protein (L-FABP) in the liver. PGE(2) content was measured in the serum, in tumor cells, and in the liver (ELISA). CPT I and CPT II maximal activity were decreased (p < 0.01) in ST when compared with SC. In contrast, serum PGE(2) was increased (p < 0.05) in cachectic animals as compared with SC. In the liver, PGE(2) content was also increased (p < 0.05) when compared with SC. Endurance training restored maximal CPT I and CPT II activity in the tumor-bearing animals (p < 0.0001). Exercise training induced PGE(2) levels to return to control values in the liver of tumor-bearing training rats (p < 0.05) and decreased the eicosanoid content in the tumor (p < 0.01). In conclusion, endurance training was capable of reestablishing liver carnitine palmitoyltransferase (CPT) system activity associated with decreased PGE(2) levels in cachectic tumor-bearing animals, preventing steatosis.
Resumo:
In this paper, we consider a hyperbolic thermoelastic system of memory type in domains with moving boundary. The problem models vibrations of an elastic bar under thermal effects according to the heat conduction law of Gurtin and Pipkin. Global existence is proved by using the penalty method of Lions. (c) 2007 Elsevier Inc. All rights reserved.
Resumo:
Lignocellulosic residues are interesting materials for the production of heavy metal adsorbents for aquatic systems. Whole fibers taken from coconut (Cocos nucifera) husks were functionalized with the thiophosphoryl (P=S) group by means of the direct reaction with CI(3)P=S, (CH(3)O)(2)CIP=S or (CH(3)CH(2)O)(2)CIP=S in order to obtain an adsorptive system for `soft` metal ions, particularly Cd(2+). These functionalized fibers (FFs) were characterized by means of elemental analysis, infrared spectroscopy, thermal analysis and acid-base titration. Adsorption isotherms for Cd(2+) fitted the Langmuir model, with binding capacities of 0.2-5 mmol g(-1) of FF at 25 degrees C. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
A flow system exploiting the multicommutation approach is proposed for spectrophotometric determination of tannin in beverages. The procedure is based on the reduction of Cu(II) in the presence of 4,4`-dicarboxy-2,2`-biquinoline, yielding a complex with maximum absorption at 558 nm. Calibration graph was linear (r=0.999) for tannic acid concentrations up to 5.00 mu mol L-1. The detection limit and coefficient of variation were estimated as 10 nmol L-1 (99.7% confidence level) and 1% (1.78 mu mol L-1 tannic acid, n=10), respectively. The sampling rate was 50 determinations per hour. The proposed procedure is more sensitive and selective than the official Folin-Denis method, also minimizing drastically waste generation. Recoveries within 91.8 and 115% were estimated for total tannin determination in tea and wine samples. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
A column switching LC method is presented for the analysis of fluoxetine (FLU) and norfluoxetine (NFLU) by direct injection of human plasma using a lab-made restricted access media (RAM) column. A RAM-BSA-octadecyl silica (C-18) column (40 min x 4.6 mm, 10 mu m) is evaluated in both backflush and foreflush elution modes and coupled with a C-18 lab-made (50 mm x 4.6 mm, 3 pm) analytical column in order to perform online sample preparation. Direct injection of 100 mu L, of plasma samples is possible with the developed approach. In addition, reduction of sample handling is obtained when compared with traditional liquid-liquid extraction (LLE) and SPE. The total analysis time is around 20 min. A LOQ of 15 ng/mL is achieved in a concentration range of 15-500 ng/mL, allowing the therapeutic drug monitoring of clinical samples. The precision values achieved are lower than 15% for all the evaluated points with adequate recovery and accuracy. Furthermore, no matrix interferences are found in the analysis and the proposed method shows to be an adequate alternative for analysis of FLU in plasma.
Resumo:
Various pellet heating systems are marketed in Sweden, some of them in combination with a solar heating system. Several types of pellet heating units are available and can be used for a combined system. This article compares four typical combined solar and pellet heating systems: System 1 and 2 two with a pellet stove, system 3 with a store integrated pellet burner and system 4 with a pellet boiler. The lower efficiency of pellet heaters compared to oil or gas heaters increases the primary energy demand. Consequently heat losses of the various systems have been studied. The systems have been modeled in TRNSYS and simulated with parameters identified from measurements. For almost all systems the flue gas losses are the main heat losses except for system 3 where store heat losses prevail. Relevant are also the heat losses of the burner and the boiler to the ambient. Significant leakage losses are noticed for system 3 and 4. For buildings with an open internal design system 1 is the most efficient solution. Other buildings should preferably apply system 3. The right choice of the system depends also on whether the heater is placed inside or outside of the heated are. A large potential for system optimization exist for all studied systems, which when applied could alter the relative merits of the different system types.
Resumo:
Participation as observer at the meeting of Task 14 of IEA's Solar Heating and Cooling Projects held in Hameln, Germany has led to greater understanding of interesting developments underway in several countries. This will be of use during the development of small scale systems suitable for Swedish conditions. A summary of the work carried out by the working groups within Task 14 is given, with emphasis on the Domestic Hot Water group. Experiences of low-flow systems from several countries are related, and the conclusion is drawn that the maximum theoretical possible increase in performance of 20% has not been achieved due to poor heat exchangers and poor stratification in the storage tanks. Positive developments in connecting tubes and pumps is noted. Further participation as observer in Task 14 meetings is desired, and is looked on favourably by the members of the group. Another conclusion is that SERC should carry on with work on Swedish storage tanks, with emphasis on better stratification and heat exchangers, and possible modelling of system components. Finally a German Do-it-Vourself kit is described and judged in comparison with prefabricated models and Swedish Do-it-Yourself kits.
Resumo:
The study reported here is part of a large project for evaluation of the Thermo-Chemical Accumulator (TCA), a technology under development by the Swedish company ClimateWell AB. The studies concentrate on the use of the technology for comfort cooling. This report concentrates on measurements in the laboratory, modelling and system simulation. The TCA is a three-phase absorption heat pump that stores energy in the form of crystallised salt, in this case Lithium Chloride (LiCl) with water being the other substance. The process requires vacuum conditions as with standard absorption chillers using LiBr/water. Measurements were carried out in the laboratories at the Solar Energy Research Center SERC, at Högskolan Dalarna as well as at ClimateWell AB. The measurements at SERC were performed on a prototype version 7:1 and showed that this prototype had several problems resulting in poor and unreliable performance. The main results were that: there was significant corrosion leading to non-condensable gases that in turn caused very poor performance; unwanted crystallisation caused blockages as well as inconsistent behaviour; poor wetting of the heat exchangers resulted in relatively high temperature drops there. A measured thermal COP for cooling of 0.46 was found, which is significantly lower than the theoretical value. These findings resulted in a thorough redesign for the new prototype, called ClimateWell 10 (CW10), which was tested briefly by the authors at ClimateWell. The data collected here was not large, but enough to show that the machine worked consistently with no noticeable vacuum problems. It was also sufficient for identifying the main parameters in a simulation model developed for the TRNSYS simulation environment, but not enough to verify the model properly. This model was shown to be able to simulate the dynamic as well as static performance of the CW10, and was then used in a series of system simulations. A single system model was developed as the basis of the system simulations, consisting of a CW10 machine, 30 m2 flat plate solar collectors with backup boiler and an office with a design cooling load in Stockholm of 50 W/m2, resulting in a 7.5 kW design load for the 150 m2 floor area. Two base cases were defined based on this: one for Stockholm using a dry cooler with design cooling rate of 30 kW; one for Madrid with a cooling tower with design cooling rate of 34 kW. A number of parametric studies were performed based on these two base cases. These showed that the temperature lift is a limiting factor for cooling for higher ambient temperatures and for charging with fixed temperature source such as district heating. The simulated evacuated tube collector performs only marginally better than a good flat plate collector if considering the gross area, the margin being greater for larger solar fractions. For 30 m2 collector a solar faction of 49% and 67% were achieved for the Stockholm and Madrid base cases respectively. The average annual efficiency of the collector in Stockholm (12%) was much lower than that in Madrid (19%). The thermal COP was simulated to be approximately 0.70, but has not been possible to verify with measured data. The annual electrical COP was shown to be very dependent on the cooling load as a large proportion of electrical use is for components that are permanently on. For the cooling loads studied, the annual electrical COP ranged from 2.2 for a 2000 kWh cooling load to 18.0 for a 21000 kWh cooling load. There is however a potential to reduce the electricity consumption in the machine, which would improve these figures significantly. It was shown that a cooling tower is necessary for the Madrid climate, whereas a dry cooler is sufficient for Stockholm although a cooling tower does improve performance. The simulation study was very shallow and has shown a number of areas that are important to study in more depth. One such area is advanced control strategy, which is necessary to mitigate the weakness of the technology (low temperature lift for cooling) and to optimally use its strength (storage).