949 resultados para tungsten coil atomization
Resumo:
The problematic that gives shape to this research is the question of the historical process of demobilization of the movement of the working classes in your accented contemporary moment. Their object of study, however, and that it particularizes, it relates to a portion this problematic; it relates to set of determinations that comprise a broader set of determinations of this historical process: it is a set of determinations forged and mediated by bourgeois strategies of management for the conformation of the circumstances necessary for the domination and for the conduct of labor force on operations in work processes for the production of surplus value. What we investigated are, because, the strategies of disarticulation that the bourgeoisie utilizes, under the mantle of subsidies conceptual and interventive of its management of work processes and the sieve of class struggles, to obstruct the union of workers; hamper the movements proletarians. Managerial strategies that intentionally or unintentionally, instill in the social relations of production means to produce and reproduce, activate and reactivate conditions of incitement of individualism and competition between the workers themselves. We shall see, thus, by analyzing means, centrally, from some of the fundamentals of disarticulation in the managerial strategies bourgeois and some of the fundamental strategies of management bourgeois hegemonized with the restructuring productive of 1970, that the disarticulation, and also the demobilization, is a concrete condition, is an objective condition, that is beyond a question that can be "solved" only by enlightenment cognitive, only by formation criticism intellectual. In everyday of the work spaces permeated by managerial strategies bourgeois there elements, then, operating as a material force putting difficulties important for the articulation of the workers, the solidarity of the proletariat; elements that constitute obstacle significant to an awareness of class and belonging; elements act in favor of the atomization of the worker - even if engenders, in the same process, as a contradiction, potentiality of resistance and fight the forces of labor
Resumo:
Veia cava inferior dupla é uma variação anatômica rara cuja prevalência é de 0,2-3%. O implante de filtro de veia cava, quando indicado em casos com duplicidade da veia cava inferior, pode ser realizado de diferentes formas: em ambas as veias cavas; em uma delas, embolizando a anastomose entre ambas; em somente uma delas; ou por implante supra-renal. Relatamos um caso de trombose venosa profunda no pós-operatório de implante de prótese de quadril com contra-indicação para tratamento anticoagulante e cuja cavografia evidenciou duplicidade de veia cava inferior. O implante de filtro de veia cava inferior realizado em posição supra-renal mostrou-se opção adequada e segura.
Resumo:
Great part of the gold mineralizations are associated with shearing zones through which circulate a great volume of fluids, that interact with the host rocks, originating leaching or precipitation of chemical elements, including gold. The studied mineralizations are inserted in the Seridó Belt. The tungsten mineralization in Brejuí Mine is hosted in calcsilicate rocks from Jucurutu Formation. The São Francisco auriferous mineralization has as host rocks mica-schists from Seridó Formation, while the Ponta da Serra and Fazenda Simpático mineralizations are hosted in orthogneisses of this fold belt basement. The research conducted on these mineralizations had the purpose of integrate the data of chemical elements behavior during the shearing/mineralizing event, and its influence on the isotopic systems Rb-Sr and Sm-Nd. The studies of chemical mobility in the auriferous mineralizations showed that elements that during the shearing displayed in general an immobile behavior were Al, Ti and Zr. Among the elements that were mobilized during the event, K and Rb showed mass gain in ali belts of transformed rocks, while the elements Ca, Na and Sr normally lost mass. Petrographic studies showed that the minerais biotite and plagioclase, in all investigated mineralizations, played an important role in the chemical reactions occurred in the transformed rocks to the generation of muscovite, cordierite and sillimanite, justifying the input of K to the formation of muscovite, and the release of Na and Ca from plagioclase to the fluid phase. In the São Francisco auriferous mineralization, the results of the Rb-Sr isotopic analysis yielded ages of 645 ± 19 Ma and 596 ± 17 Ma, with both samples, from original and transformed rocks. Two ages, 569 ± 20 Ma. and 554 ± 19 Ma., were obtained with samples frem the transformed rocks domain. These ages suggest that there were two metamorphic pulses during the emplacement of the mineralized shearing zone. The Sm-Nd data yielded TDM ages of 1,31 Ga and 1,26 Ga with 3Nd (0,6 Ga) of -0,26 e -0,40 for the original and final transformed rocks, respectively. In case of the orthogneisses of Caicó Complex, e.g. the Ponta da Serra and Fazenda Simpático mineralizations, the Rb-Sr data did not yield ages with geological significance. In the Ponta da Serra mineralization, the Sm-Nd isotopic data yielded T DM ages of 2,56 Ga and 2,63 Ga to the original rocks and of 2,71 Ga to the mineralized sheared rock, and values of 3Nd (2,0 Ga) between -3,70 e -5,42 to the original and sheared rock, respectively. In the Fazenda Simpático, Sm-Nd data yielded TDM between 2,65 and 2,69 Ga with values of 3Nd (2,0 Ga) between -5,25 e -5,52. Considering the Sm-Nd data, the TDM ages may be admitted as the age of the parental magma extraction, producer of the protoliths of the orthogneisses from Ponta da Serra and Fazenda Simpático mineralizations. The chemical mobility studies showed that in the basement hosted mineralizations, Rb achieved mass while Sr lost mass, as Sm as well as Nd were strongly mobilized. The Sm/Nd ratio remained constant, however, confirming the isochemical character of those elements. In the basement mineralizations, Rb-Sr ages are destituted of geological significance, because of the partial opening of the isotopic system during the tectono-metamorphic transformations. In the tungsten mineralization, the diagram Sm-Nd constructed with the whole-rock data of calcsilicatic and the high-temperature paragenesis (garnet, diopside and iron-pargasitic hornblende) indicated an 631 ± 24 Ma age, while with the whole-rock data and low-temperature paragenesis (vesuvianite, epidote and calcite), a 537 ± 107 Ma age was obtained. These ages, associated with the petrographic observations, suggest that there was a time gap among the hydrothernal events responsible by the formation of the high and low temperature paragenesis in the calcsilicatic rocks mineralized in scheelite
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: This study used bovine ribs to comparatively assess the deformation, roughness, and mass loss for 3 different types of surface treatments with burs, used in osteotomies, for the installation of osseointegrated implants.Materials and Methods: The study used 25 bovine ribs and 3 types of helical burs (2.0 mm and 3.0 mm) for osteotomies during implant placement (a steel bur [G1], a bur with tungsten carbide film coating in a carbon matrix [G2], and a zirconia bur [G3]), which were subdivided into 5 subgroups: 1, 2, 3, 4, and 5, corresponding to 0, 10, 20, 30, and 40 perforations, respectively. The surface roughness (mean roughness [Ra], partial roughness, and maximum roughness) and mass (in grams) of all the burs were measured, and the burs were analyzed in a scanning electron microscope before and after use. Data were tabulated and statistically analyzed by use of the Kruskal-Wallis test, and when a statistically significant difference was found, the Dunn test was used.Results: There was a loss of mass in all groups (G1, G2, and G3), and this loss was gradual, according to the number of perforations made (1, 2, 3, 4, and 5). However, this difference was not statistically significant (P < .05). Regarding the roughness, G3 presented an increase in Ra, partial roughness, and maximum roughness (P < .05) compared with G2 and an increase in Ra compared with G1. There was no statistically significant difference (P > .05) between G1 and G2. The scanning electron microscopy analysis found areas of deformation in all the 2.0-mm samples, with loss of substrates, and this characteristic was more frequent in G3.Conclusions: The 2.0-mm zirconia burs had a greater loss of substrates and abrasive wear in the cutting area. They also presented an increased roughness when compared with the steel and the tungsten carbide coating film in carbon matrix. There was no statistically significant difference (P < .05) between G1 and G2 in any mechanical test carried out. (C) 2012 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 70:e608-e621, 2012
Resumo:
The aims of this in vivo study were to compare the effectiveness and color stability of at-home and in-office bleaching techniques and to evaluate whether the use of light sources can alter bleaching results. According to preestablished criteria, 40 patients were selected and randomly divided into four groups according to bleaching treatment: (1) at-home bleaching with 10% carbamide peroxide, (2) in-office bleaching with 35% hydrogen peroxide (HP) without a light source, (3) in-office bleaching with 35% HP with quartz-tungsten-halogen light, and (4) in-office bleaching with 35% HP with a light-emitting diode/laser. Tooth shade was evaluated using the VITA Classical Shade Guide before bleaching as well as after the first and third weeks of bleaching. Tooth shade was evaluated again using the same guide 1 and 6 months after the completion of treatment. The shade guide was arranged to yield scores that were used for statistical comparison. Statistical analysis using the Kruskal-Wallis test showed no significant differences among the groups for any time point (P > .01). There was no color rebound in any of the groups. The bleaching techniques tested were equally effective. Light sources are unnecessary to bleach teeth. (Int J Periodontics Restorative Dent 2012;32:303-309.)
Resumo:
INTRODUÇÃO: a preservação da estrutura de esmalte após a remoção dos acessórios ortodônticos é obrigação do clínico. Portanto, procura-se um protocolo de descolagem com bases científicas. OBJETIVO: objetivou-se avaliar por microscopia eletrônica de varredura (MEV) a influência de quatro protocolos de remoção de braquetes e polimento da superfície do esmalte e propor um protocolo que minimize os danosà superfície do esmalte. MÉTODOS: doze incisivos permanentes bovinos foram divididos em quatro grupos de acordo com os instrumentos utilizados para a descolagem dos braquetes e remoção do remanescente adesivo. Os braquetes foram descolados com o alicate de descolagem reto (Ormco Corp.) nos grupos 1 e 2, e com o instrumento de descolagem Lift-Off (3M Unitek) nos grupos 3 e 4. Os remanescentes adesivos dos grupos 1 e 3 foram removidos com o alicate removedor de resina longo (Ormco Corp.) e dos grupos 2 e 4 com broca de carboneto de tungstênio (Beavers Dental) em alta-rotação. As superfícies, após cada etapa da descolagem e polimento, foram avaliadas em réplicas de resina epóxica e foram obtidas eletromicrografias com aumento de 50 e 200X. RESULTADOS: os quatro protocolos de remoção de acessórios ortodônticos e polimento ocasionaram irregularidades no esmalte. Conclusão: a remoção do braquete com o alicate de descolagem reto, seguido da remoção do remanescente adesivo com broca de carboneto de tungstênio e polimento final com pasta de pedra-pomes foi o procedimento que ocasionou menores danos ao esmalte, sendo o protocolo sugerido para a remoção dos acessórios ortodônticos.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: Different surface treatments have been developed in attempts to prevent the loosening of abutment screws. The aim of the current study was to compare the effectiveness of titanium alloy screws with tungsten-doped diamond-like carbon (W-DLC) coating and uncoated screws in providing stability to zirconia (ZrO2) ceramic abutments after cyclic loading. Materials and Methods: Twenty prefabricated ZrO2 ceramic abutments on their respective external-hex implants were divided into two groups of equal size according to the type of screw used: uncoated titanium alloy screw (Ti) or titanium alloy screw with W-DLC coating (W-DLC/Ti). The removal torque value (preload) of the abutment screw was measured before and after loading. Cyclic loading between 11 and 211 N was applied at an angle of 30 degrees to the long axis of the implants at a frequency of 15 Hz. A target of 0.5 x 10(6) cycles was defined. Group means were calculated and compared using analysis of variance and the F test (alpha=.05). Results: Before cyclic loading, the preload for Ti screws was significantly higher than that for W-DLC/Ti screws (P=.021). After cyclic loading, there was no significant difference between them (P=.499). Conclusions: Under the studied conditions, it can be concluded that, after cyclic loading, both abutment screws presented a significant reduction in the mean retained preload and similar effectiveness in maintaining preload. INT J ORAL MAXILLOFAC IMPLANTS 2012;27:1061-1067
Resumo:
This study evaluated the influence of light-curing units (LCUs) on Knoop microhardness (KHN) of different composite resins formulations. Four LCUs, one Quartz-Tungsten-Halogen (QTH) for 20 s, one Argon-Ion-Laser (AL) for 10 s, one Plasma-Arc-Curing (PAC) for 9 s, and one Light-Emitting-Diode (LED) for 20 s, and three composite resins, nanofill and easy cure (Filtek (TM) Supreme), microhybrid and medium cure (Herculite XRV), and microfill and difficult cure (Heliomolar) were used. Discs (4 x 2 mm(2)) of each composite resin were divided in 12 Groups and KHN was measured at the top (T) and bottom (B) surfaces. Data were analyzed using two-way ANOVA and Tukey's test (p < 0.05). Top presented significantly higher KHN than bottom surface for all composite resins and LCUs tested. Statistical significant differences were observed among the LCUs. At the bottom surface QTH and LED presented higher KHN than PAC and LA. However, at the top surface PAC and LA presented similar results than QTH for nanofill and microhybrid composite resins. Different LCUs play an important effect on Knoop microhardness and the composite resin formulations were significant factor on the photosensitivity.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Objective: This study aimed at evaluating the degree of conversion (DC) of four composite resins, being one nanofilled and 3 microhybrid resins, photo-activated with second- and third-generation light-emitting diodes (LEDs). Material and methods: Filtek (TM) Z350 nanofilled composite resins and Amelogen (R) Plus, Vit-l-escence (TM) and Opallis microhybrid resins were photo-activated with two second-generation LEDs (Radii-cal and Elipar Free Light (TM) 2) and one third-generation LED (Ultra-Lume LED 5) by continuous light mode, and a quartz halogen-tungsten bulb (QHT, control). After 24 h of storage, the samples were pulverized into fine powder and 5 mg of each material were mixed with 100 mg of potassium bromide (KBr). After homogenization, they were pressed, which resulted in a pellet that was evaluated using an infrared spectromer (Nexus 470, Thermo Nicolet) equipped with TGS detector using diffuse reflectance (32 scans, resolution of 4 cm(-1)) coupled to a computer. The percentage of unreacted carbon-carbon double bonds (% C=C) was determined from the ratio of absorbance intensities of aliphatic C=C (peak at 1637 cm-1) against internal standard before and after curing of the specimen: aromatic C-C (peak at 1610 cm-1). Results: The ANOVA showed a significant effect on the interaction between the light-curing units (LCUs) and the composite resins (p<0.001). The Tukey's test showed that the nanofilled resin (Filtek (TM) Z350) and Opallis when photo-activated by the halogen lamp (QTH) had the lowest DC compared with the other microhybrid composite resins. The DC of the nanofilled resin (Filtek (TM) Z350) was also lower using LEDs. The highest degrees of conversion were obtained using the third-generation LED and one of second-generation LEDs (Elipar Free Light (TM) 2). Conclusions: The nanofilled resin showed the lowest DC, and the Vit-l-escence (TM) microhybrid composite resin showed the highest DC. Among the LCUs, it was not possible to establish an order, even though the second-generation LED Radii-cal provided the lowest DC.