882 resultados para time domain analysism transmission line matrix methods


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study compared the effectiveness of the multifocal visual evoked cortical potentials (mfVEP) elicited by pattern pulse stimulation with that of pattern reversal in producing reliable responses (signal-to-noise ratio >1.359). Participants were 14 healthy subjects. Visual stimulation was obtained using a 60-sector dartboard display consisting of 6 concentric rings presented in either pulse or reversal mode. Each sector, consisting of 16 checks at 99% Michelson contrast and 80 cd/m2 mean luminance, was controlled by a binary m-sequence in the time domain. The signal-to-noise ratio was generally larger in the pattern reversal than in the pattern pulse mode. The number of reliable responses was similar in the central sectors for the two stimulation modes. At the periphery, pattern reversal showed a larger number of reliable responses. Pattern pulse stimuli performed similarly to pattern reversal stimuli to generate reliable waveforms in R1 and R2. The advantage of using both protocols to study mfVEP responses is their complementarity: in some patients, reliable waveforms in specific sectors may be obtained with only one of the two methods. The joint analysis of pattern reversal and pattern pulse stimuli increased the rate of reliability for central sectors by 7.14% in R1, 5.35% in R2, 4.76% in R3, 3.57% in R4, 2.97% in R5, and 1.78% in R6. From R1 to R4 the reliability to generate mfVEPs was above 70% when using both protocols. Thus, for a very high reliability and thorough examination of visual performance, it is recommended to use both stimulation protocols.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Esta tese refere-se ao uso de modelos de attachment de lideres (Leader Progression Model – LPM) para estimativa da distancia de salto, que, junto com dados de densidade de raios como coletado pelo sistema de detecção de raios do SIPAM, são usados para estimar a taxa de flashover em linhas de transmissão de eletricidade na Amazônia. O modelo de progressão de líder desenvolvido nesta tese é denominado ModSalto, que, para estimar a distancia de salto: 1- integra a densidade linear de cargas elétricas devida ao líder, proporcional a prospectiva corrente de primeira descarga (1º stroke) Ip, para determinar o campo elétrico produzido pelo líder descendente na estrutura sob estudo (para-raios, arestas, condutores, etc.); 2 – integra a distribuição imagem do líder descendente, fazendo uso da característica de poder das pontas como fator de estimulo e intensificação do campo elétrico devido a streamers nas partes aguçadas das estruturas sob estudo, para temporizar o momento do processo de attachment. O gatilho para o líder descendente, por hipótese, se deve a ejeção aleatória de pacotes de cargas elétricas em domínios turbulentos no interior das nuvens que recebem energia por processos de cascata da turbulência geral, e o comportamento do líder descendente, deve obedecer à equação da força de Lorentz, no espaço de campos cruzados elétrico devido às nuvens a cima e o campo magnético da Terra, que obriga as cargas do líder a desenvolverem movimentos cicloidais que podem explicar a natureza tortuosa do trajeto do líder descendente. Com o objetivo de formalizar dados consistentes de densidade de raios é feita uma reanalise do conjunto de dados coletado pelo LLS SIPAM de outubro de 2006 a julho de 2008 na região amazônica, com cerca de 3 milhões de eventos, comparando-os com dados de torres instrumentadas para evidenciar-se sua qualidade e usabilidade. Dados de elevação de terreno do SRTM da NASA são usados para gerar formula do raio de atração (Ra) das estruturas passiveis de serem atingidas por raios e para gerar formulas de área de atração, usadas para quantificar o numero de raios que provavelmente atingirão determinada estrutura, baseado no valor de densidade de raios (raios/km2/ano) na área em estudo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Fisioterapia - FCT

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents a strategy to control nonlinear responses of aeroelastic systems with control surface freeplay. The proposed methodology is developed for the three degrees of freedom typical section airfoil considering aerodynamic forces from Theodorsen's theory. The mathematical model is written in the state space representation using rational function approximation to write the aerodynamic forces in time domain. The control system is designed using the fuzzy Takagi-Sugeno modeling to compute a feedback control gain. It useds Lyapunov's stability function and linear matrix inequalities (LMIs) to solve a convex optimization problem. Time simulations with different initial conditions are performed using a modified Runge-Kutta algorithm to compare the system with and without control forces. It is shown that this approach can compute linear control gain able to stabilize aeroelastic systems with discontinuous nonlinearities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Flexible poles are tools used to provide rapid eccentric and concentric muscle contractions. It lacks in the literature studies that analyze acute cardiovascular responses in different exercises performed with this instrument. It was investigated the acute effects of exercise with flexible poles on heart period in healthy women. Methods: The study was performed on 32 women between 18 and 25 years old. It was evaluated the heart rate variability (HRV) in the time (SDNN, RMSSD and pNN50) and frequency domain (HF, LF and LF/HF ratio). The subjects remained at rest for 10 minutes. After the rest period, the volunteers performed the exercises with the flexible poles. Immediately after the exercise protocol, the volunteers remained seated at rest for 60 minutes and HRV were analyzed. Results: It was observed no significance changes in the time domain (SDNN: p = 0.14; RMSSD: p = 0.8 and pNN50: p = 0.86) and frequency domain indices (LF (nu): 0.4; LF (ms2): p = 0.34; HF (nu): p = 0.4; HF (ms2): p = 0.8 and LF/HF ratio: p = 0.3) between before and after single bout of exercise with flexible pole. Conclusion: A single bout of exercise with flexible pole did not significantly change cardiac autonomic regulation in healthy women.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

100.00% 100.00%

Publicador:

Resumo:

With the increasing demand for electricity, the retraining of transmission lines is necessary despite environmental restrictions and crossings in densely populated areas to build new transmission and distribution lines. Solution is reuse the existent cables, replacing the old conductor cables for new cables with higher capacity power transmission, and control of sag installed. The increasing demand for electrical power has increased the electric current on the wires and therefore, it must bear out temperatures of 150°C or more, without the risk of the increasing sag beyond the established limits. In the case of long crossings or densely populated areas, sag is due to high weight of the cable on clearance. The cable type determines the weight, sag, height and the towers dimensions, which are the items that most influence the investment of the transmission line. Hence, to reduce both cost of investment and maintenance of the line, the use of a lighter cable can reduce both number and the height of the towers, with financial return on short and long term. Therefore, in order to increase the amount of transmitted energy and reduce the number of built towers and sag, is recommended in the current work substitute the current core material (steel or aluminium) for alternatives alloys or new materials, in this case a composite, which has low density, elevated stiffness (elasticity module), thus apply the pultruded carbon fiber with epoxy resin as matrix systems and perform the study of the kinetics of degradation by thermogravimetric analysis (TGA), dynamic mechanical analysis (DMA) and differential scanning calorimetry (DSC), according to their respective standards

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Exercise with flexible poles provides fast eccentric and concentric muscle contractions. Although the literature reports significant muscle chain activity during this exercise, it is not clear if a single bout of exercise induces cardiac changes. In this study we assessed the acute effects of flexible pole exercise on cardiac autonomic regulation.Methods: The study was performed on 22 women between 18 and 26 years old. We assessed heart rate variability (HRV) in the time (SDNN, RMSSD and pNN50) and frequency (HF, LF and LF/HF ratio) domains and geometric indices of HRV (RRTri, TINN, SD1, SD2 and SD1/SD2 ratio). The subjects remained at rest for 10 min and then performed the exercises with the flexible poles. Immediately after the exercise protocol, the volunteers remained seated at rest for 60 min and HRV was analyzed.Results: We observed no significant changes in time domain (SDNN: p=0.72; RMSSD: p=0.94 and pNN50: p=0.92) or frequency domain indices (LF [nu]: p=0.98; LF [ms(2)]: p=0.72; HF [nu]: p=0.98; HF [ms(2)]: p=0.82 and LF/HF ratio: p=0.7) or in geometric indices (RRTri: p=0.54; TINN: p=0.77; SD1 p=0.94; SD2: p=0.67 and SD/SD2: p=0.42) before and after a single bout of flexible pole exercise.Conclusion: A single bout of flexible pole exercise did not induce significant changes in cardiac autonomic regulation in healthy women. (C) 2014 Sociedade Portuguesa de Cardiologia. Published by Elsevier Espana, S.L.U. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUÇÃO: Um dos benefícios promovidos pelo exercício físico parece ser a melhora da modulação do sistema nervoso autônomo sobre o coração. No entanto, o papel da atividade física como um fator determinante da variabilidade da frequência cardíaca (VFC) não está bem estabelecido. Desta forma, o objetivo do estudo foi verificar se há correlação entre a frequência cardíaca de repouso e a carga máxima atingida no teste de esforço físico com os índices de VFC em homens idosos. MÉTODOS: Foram estudados 18 homens idosos com idades entre 60 e 70 anos. Foram feitas as seguintes avaliações: a) teste de esforço máximo em cicloergômetro utilizando-se o protocolo de Balke para avaliação da capacidade aeróbia; b) registro da frequência cardíaca (FC) e dos intervalos R-R durante 15 minutos na condição de repouso em decúbito dorsal. Após a coleta, os dados foram analisados no domínio do tempo, calculando-se o índice RMSSD, e no domínio da frequência, calculando-se os índices de baixa frequência (BF), alta frequência (AF) e razão BF/AF. Para verificar se existe associação entre a carga máxima atingida no teste de esforço e os índices de VFC foi aplicado o teste de correlação de Pearson (p < 0,05). RESULTADOS: Características demográficas, antropométricas, fisiológicas e carga máxima atingida no teste ergométrico: idade = 63 ± 3,0 anos; IMC = 24 ± 2kg/m²; FC = 63 ± 9bpm; PAS = 123 ± 19mmHg; PAD = 83 ± 8mmHg; carga máxima = 152 ± 29 watts. Não houve correlação entre os índices de VFC com os valores de FC de repouso e carga máxima atingida no teste ergométrico (p > 0,05). CONCLUSÃO: Os índices de variabilidade da frequência cardíaca temporal e espectrais estudados não são indicadores do nível de capacidade aeróbia de homens idosos avaliados em cicloergômetro.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)