969 resultados para tentacle analog


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The double pulley equipment was tested on ten male volunteers during contraction of the semitendinosus and biceps femoris (caput longum) muscles in the following movements of the lower limbs: 1) hip extension with extended knee and erect trunk, 2) hip extension with flexed knee and erect trunk, 3) hip extension with flexed knee and erect trunk, 3) hip extension with extended knee and inclined trunk, 5) hip abduction along the midline, 7) hip abduction with extension beyond the midline, 8) adduction with hip flexion beyond the midline, 8) adduction with hip flexion beyond the midline, and 9) adduction with hip extension beyond the midline. The myoelectric signals were taken up by Lec Tec surface electrodes connected to a 6-channel Lynx electromyographic signal amplifier coupled with a computer equipped with a model CAD 10/26 analogue digital conversion board and with a specific software for signal recording and analysis. The semitendinosus and biceps femoris muscles presented the highest potentials in movements 1; 2; 7, 8 and 9, whereas the potentials in the remaining movements were negligible. The pattern of activity of the semitendinosus and the biceps femoris was similar in exercises 1, 2, 3, 4 and 8. The potentials of the semitendinosus prevailed in movements 5, 6 and 7, and the strongest potentials observed in movement 9 were those of the biceps femoris.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We investigated plasma luteinizing hormone (LH) concentration in domestic male cats challenged with Luteinizing Hormone Releasing Hormone Analog (LHRH-A) [des Gly10, (DTrp6)-LHRH ethylamide] that mediates the function of the hypothalamic-piruitary-gonadal axis (HPG). Plasma LH concentrations in cats treated daily with LHRH (10 μg/ 100 μl/kg/day, subcutaneously - sc) for 19 days (LHRH group) and in controls treated with saline (NaCl - 0.9%, same volume - SAL group) were chronically studied. LHRH administration (sc) for 15 days induced a significant fall (P < 0.05) in plasma LH concentrations during the chronic study. After the 15th day of treatment the groups were divided once more into animals treated with LHRH (10 μg/100 μl/kg) or saline (iv), and a time course study (300 min) was performed (acute study). Next, four groups of cats were compared in an acute study involving the sc/iv administration of SAL/SAL, SAL/LHRH, LHRH/SAL, and LHRH/LHRH. The responses of the SAL animals challenged by acute iv administration of LHRH (group SAL/LHRH) were significantly higher (P < 0.01) than those of animals treated with LHRH (sc) (group LHRH/LHRH). LH release was also significantly increased in the latter group (P < 0.05), although the effect was short lasting, being recorded only at the first observation (45 min). An in vitro study with the pituitaries was also performed on day 20. Mean (±SEM) LH concentrations in the culture medium containing pituitaries with LHRH (10-7 M) or saline were determined. In vitro analysis of these pituitaries demonstrated a significantly reduced response (P < 0.05) by animals treated sc with LHRH for 19 days. This study represents a source of data for the domestic cat going beyond its own physiology. Serving as a model, this animal provide important information for the study of reproductive physiology in other members of its family (Felidae), almost all of them threatened with extinction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Temporomandibular disorder (TMD) is characterized by a combination of symptoms affecting the temporomandibular joint and/or chewing muscles. The two most common clinical TMD symptoms are pain and dysfunction. Pain is usually caused by dysfunction, and emergency therapy has focused on controlling it. Recent investigations into TMD have led to the recommendation of antidepressants as a supporting treatment against constant neuralgic pain. The aim of this double-blind study was to verify the efficiency of antidepressants (amitriptyline) as a support in the treatment of chronic TMD pain. Twelve female volunteers presenting chronic TMD pain were divided into two groups and treated for 14 days: Group 1 with 25 mg/day of amitriptyline and Group 2 with a placebo. The intensity of pain and discomfort was evaluated daily, using a visual analog scale (VAS), over a period of seven days preceding the treatment (baseline), during the 14-day treatment, and for seven days after the treatment. The results revealed a significant reduction of pain and discomfort in Group 1 (75%) compared to Group 2 (28%) during the three weeks beginning at baseline (p< 0.01). Amitriptyline proved to be an efficient alternative treatment for chronic pain in TMD patients. Copyright © 2003 by CHROMA, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The aim of this study was to evaluate the effectiveness of the clinical use of the gallium-aluminum-arsenium (GaAlAs) laser at the maximum and minimum energies recommended by the manufacturer for the treatment of dentine hypersensitivity. Background Data: Dentine hypersensitivity (DH) is a response to a stimulus that would not usually cause pain in a healthy tooth. It is characterized by sharp pain of short duration from the denuded dentin. Its etiology is unknown. The dentin only begins to show sensitivity when exposed to the buccal environment. This exposure can result after removal of the enamel and/or dental cement, or after root denudation. Different treatments are proposed for this disorder. Materials and Methods: In this study, 25 patients, with a total number of 106 cases of DH, were treated with GaAlAs low-level laser therapy (LLLT). 65% of the teeth were premolars; 14% were incisors and molars; 6.6% were canines. The teeth were irradiated with 3 and 5 J/cm 2 for up to six sessions, with an interval of 72 h between each application, and they were evaluated initially, after each application, and at 15 and 60 days follow-up post-treatment. Results: The treatment was effective in 86.53% and 88.88% of the irradiated teeth, respectively, with the minimum and maximum energy recommended by the manufacturer. There was a statistically significant difference between DH and after a follow-up of 60 days for both groups. The difference among the energy maximum and minimum was not significant. Conclusion: The GaAlAs low-level laser was effective in reducing initial DH. A significant difference was found between initial values of hypersensitivity and after 60 days follow-up post-treatment. No significant difference was found between minimum (3 J/cm 2) and maximum (5 J/cm 2) applied energy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: Before epídural steroids were used in chronic lumbar pain, subarachnoid injection of these agents was the treatment of choice. Although still preconized by some authors, this technique may lead to severe complications with neurological sequelae. This report aimed at describing a case of accidental subarachnoid injection of steroid associated to local anesthetics during epidural puncture to treat lumbar pain. CASE REPORT: Male patient, 46 years old, followed byneuro-surgery for presenting right sciatic pain for 9 month, refractory to clinical treatment due to L 4-L 5 disk protrusion confirmed by CT scan, without neurological deficit. Epidural puncture for pain treatment was performed in L 4-L 5 with 17G needle and 10 mL solution were injected containing 4 mL of 0.25% bupivacaine, 80 mg methylprednisolone and 4 mL of 0.9% saline. Although there has not been CSF reflux, 5 minutes after injection there were sensory block in T 4 and motor block in T 6, associated to blood pressure and heart rate decrease. CONCLUSIONS: Accidental subarachnoid injections with the association of steroids for pain relief may cause adverse effects. There are several risks, varying from mild transient symptoms to nervous injuries, including spinal cord injuries. Our patient had no sequelae from the accidental subarachnoid injection, probably because it has been a single injection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To measure 2-week postoperative sensitivity in Class II composite restorations placed with a self-etching adhesive (Clearfil SE Bond) or a total-etch adhesive (Prime&Bond NT) with or without a flowable composite as cervical increment. Method and materials: Upon approval by the University of Guarulhos Committee on Human Subjects, 100 restorations were inserted in 46 patients who required Class II restorations in their molars and premolars. Enamel and dentin walls were conditioned with a self-etching primer (for Clearfil SE Bond) or etched with 34% phosphoric acid (for Prime&Bond NT). A 1- to 2-mm-thick increment of a flowable composite (Filtek Flow) was used in the proximal box in 50% of the restorations of each adhesive. Preparations were restored with a packable composite (Surefil). The restorations were evaluated preoperatively and 2 weeks postoperatively for sensitivity to cold, air, and masticatory forces using a visual analog scale. Marginal integrity of the accessible margins was also evaluated. Statistical analysis used a mixed linear model with subject as a random effect. Results: Ninety-eight teeth from 44 subjects were observed at 2 weeks. The type of adhesive and use of flowable composite had no significant effects or interaction for any of the four outcomes of interest, ie, change from baseline to 2 weeks in sensitivity and response time for the cold or air stimulus. For the air stimulus, the overall average change from baseline was not significant for either sensitivity or response time. For the cold stimulus, the overall average change from baseline was significant for both sensitivity and response time. No case of sensitivity to masticatory forces was observed. Conclusion: No differences in postoperative sensitivity were observed between a self-etch adhesive and a total-etch adhesive at 2 weeks. The use of flowable composite did not decrease postoperative sensitivity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The accuracy of impressions that transfer the relationship of the implant to the metal framework of the prosthesis continues to be a problem. This study was designed to evaluate the accuracy of the transfer process under variable conditions with regard to implant analog angulations, impression materials, and techniques. Replicas (n = 60) of a metal matrix (control) containing four implants at 90°, 80°, 75°, and 65° in relation to the horizontal surface were obtained by using three impression techniques: T1 - indirect technique with conical copings in closed trays; T2 - direct technique with square copings in open trays; and T3 - square copings splinted with autopolymerizing acrylic resin; and four elastomers: P-polysulfide; I-polyether; A-addition silicone; and Z-condensation silicone. The values of the implant analog annulations were assessed by a profilometer to the nearest 0.017°, then submitted to analysis of variance for comparisons at significance of 5% (P < .05). For implant analog at 90°, the material A associated with T2 and material Z with T3 behaved differently (P < .05) from all groups. At 80°, all materials behaved differently (P < .01) with T1. At 75°, when T1 was associated, materials P and A showed similar behavior, as well as materials I and Z; however, P and A were different from I and Z (P < .01). When T3 was associated, all experimental groups behaved differently among them (P < .01). At 65°, the materials P and Z behaved differently (P < .01) from the control group with T1, T2, and T3; the materials I and A behaved differently from the control group (P < .01) when T1 and T2, respectively, were associated. The more perpendicular the implant analog annulation is in relation to the horizontal surface, the more accurate the impression. The best materials were material I and A and the most satisfactory technique was technique 3.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work aims at finding out the threshold to burning in surface grinding process. Acoustic emission and electric power signals are acquired from an analog-digital converter and processed through algorithms in order to generate a control signal to inform the operator or interrupt the process in the case of burning occurrence. The thresholds that dictate the situation of burn and non-burn were studied as well as a comparison between the two parameters was carried out. In the experimental work one type of steel (ABNT-1045 annealed) and one type of grinding wheel referred to as TARGA model 3TG80.3-NV were employed. Copyright © 2005 by ABCM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Geographic Information Systems (GIS) integrate the technologies related to Geoprocessing, with the ability to manipulate georeferenced information through data storage, management and analysis. One of the GIS applications is the generation of Digital Elevation Models (DEM) as a result of rebuilding the elevation of a region using computation tools and artificial representation. This paper presents the DEM created from a point base in two computational frameworks with different structures (vector and raster), comparing the contour lines generated from these models with the original contour lines from analog cartographic base. It was observed that one of the generated models presented some discrepancies related to real space for both GIS structures. However, using constrained Delaunay's triangulation in raster GIS a digital elevation model was generated with contour lines quite close to the original ones, with satisfactory results. A 3-D terrain representation was also created offering a very useful tool for analysis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents an intelligent search strategy for the conforming bad data errors identification in the generalized power system state estimation, by using the tabu search meta heuristic. The main objective is to detect critical errors involving both analog and topology errors. These errors are represented by conforming errors, whose nature affects measurements that actually do not present bad data and also the conventional bad data identification strategies based on the normalized residual methods. ©2005 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to analyze the electromyographic (EMG) signal behavior of rectus femoris (RF), vastus medialis (VM), vastus lateralis (VL) and biceps femoris (caput longum) (BFCL) from nine women during fatiguing dynamic and isometric knee extensions tests and to determine their EMGFT (Electromyographic Fatigue Threshold). Surface electrodes, biological signal acquisition module, analogical-digital converter board and specific software were used. The RMS (Root Mean Square) values obtained from concentric phase (80 to 30 degrees) of the dynamic knee extension andfrom isometric contraction were correlated with time on each load by linear regression analysis. The respective slopes were correlated with the correspondent load to determine the EMGFT. Force (Kgf) and median frequency - MF (Hz) obtained during MIVC (Maximal Isometric Voluntary Contraction) performed before and after the fatiguing tests were calculated in Matlab environment. The results demonstrated that the endurance time decreases with higher loads the EMG amplitude increase with time and was greater at higher loads, between muscles in dynamic exercise the RF and VL showed higher slopes, and in isometric exercise the VL showed the same behavior The EMGFT values were similar in both exercises; the force values predominantly decreased after fatiguing tests; however the MF only decreased after some loads. The protocols proposed allowed standardizing protocols at least to induce the fatigue process and to determine the EMGFT as an endurance indicative, which may be used to evaluate the effectiveness of rehabilitative or training interventions indicated to reduce muscle weakness and fatigue.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of highly active antiretroviral therapy (HAART) in HIV-infected patients has been associated with the development of risk factors for cardiovascular diseases (CD) including dyslipidemia and insulin resistance, hypertriglyceridemia being the most frequent metabolic disturbance in these patients. Fibrates are indicated when hypertriglyceridemia is accentuated and persists for over six months. We evaluated the efficacy and safety of bezafibrate for the treatment of hypertriglyceridemia in HIV-infected individuals on HAART. All patients received 400mg/day of bezafibrate and were evaluated three times: Mo (pre-treatment), M1 (one month after treatment), and M2 (six months after treatment). Fifteen adult individuals, eight males and seven females with mean age = 41.2 ± 7.97 years and triglyceride serum levels ≥400mg/dL were included in the study. Smoking, alcohol ingestion and sedentarism rates were 50%, 6.66% and 60%, respectively. Family history of CD, hypertension and diabetes mellitus was reported in 33.3%, 40% and 46.7% of the cases, respectively, while dyslipidemia was reported by only 13.3%. More than half of the patients were using a protease inhibitor plus a nucleotide analog transcriptase inhibitor. Eutrophy and tendency toward overweight were observed at all three study time points. There were significant reductions in triglyceride serum levels from Mo to M1 and from Mo to M2. No significant changes were observed in the serum levels of creatine phosphokinase, hepatic enzymes, CD4 +, CD8 + and viral load. Therefore, bezafibrate seems to be safe and effective for the reduction of hypertriglyceridemia in HIV-infected patients on HAART. © 2006 by The Brazilian Journal of Infectious Diseases and Contexto Publishing. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work involved the development of a smart system dedicated to surface burning detection in the grinding process through constant monitoring of the process by acoustic emission and electrical power signals. A program in Visual Basic® for Windows® was developed, which collects the signals through an analog-digital converter and further processes them using burning detection algorithms already known. Three other parameters are proposed here and a comparative study carried out. When burning occurs, the newly developed software program sends a control signal warning the operator or interrupting the process, and delivers process information via the Internet. Parallel to this, the user can also interfere in the process via Internet, changing parameters and/or monitoring the grinding process. The findings of a comparative study of the various parameters are also discussed here. Copyright © 2006 by ABCM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Today, the trend within the electronics industry is for the use of rapid and advanced simulation methodologies in association with synthesis toolsets. This paper presents an approach developed to support mixed-signal circuit design and analysis. The methodology proposed shows a novel approach to the problem of developing behvioural model descriptions of mixed-signal circuit topologies, by construction of a set of subsystems, that supports the automated mapping of MATLAB®/SIMULINK® models to structural VHDL-AMS descriptions. The tool developed, named MS 2SV, reads a SIMULINK® model file and translates it to a structural VHDL-AMS code. It also creates the file structure required to simulate the translated model in the System Vision™. To validate the methodology and the developed program, the DAC08, AD7524 and AD5450 data converters were studied and initially modelled in MATLAB®/ SIMULINK®. The VHDL-AMS code generated automatically by MS 2SV, (MATLAB®/SIMULINK® to System Vision™), was then simulated in the System Vision™. The simulation results show that the proposed approach, which is based on VHDL-AMS descriptions of the original model library elements, allows for the behavioural level simulation of complex mixed-signal circuits.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An analog circuit that implements a radial basis function network is presented. The proposed circuit allows the adjustment of all shape parameters of the radial functions, i.e., amplitude, center and width. The implemented network was applied to the linearization of a nonlinear circuit, a voltage controlled oscillator (VCO). This application can be classified as an open-loop control in which the network plays the role of the controller. Experimental results have proved the linearization capability of the proposed circuit. Its performance can be improved by using a network with more basis functions. Copyright 2007 ACM.