943 resultados para synthetic aperture radar
Resumo:
The multi stage filtration (MSF) is an alternative that permits to enlarge the spectrum of application of the slow sand filtration as for the effluent quality and run duration. In this research the use of MSF technology associated to a granular activated carbon (GAC) column as polishing mechanism of the final effluent was evaluated; in the slow sand filters GAC was used as an intermediate layer and non-woven synthetic fabrics were utilized as a first layer of the filter media. Five different tests were conducted, where the systems subjected to the treatment were: water from the Ipe Lake (Ilha Solteira, Sao Paulo, Brazil); water from the lake with water from a recreational fish pond; water from the lake with a phytoplankton and cyanobacteria overload simulation, with and without the use of the pre-filters as a stage of the treatment. The synthetic fabrics and GAC use resulted in the best turbidity removal and an efficient apparent and true color removal; in spite that the polishing columns reported similar results for those parameters. The utilization of GAC as an intermediate layer contributed to a better organic matter removal and the fabrics improved chlorophyll-a removal. The pre-filtration columns made an efficient algae and cyanobacteria removal, a function that was completed by the filters and reached >98% efficiency. The synthetic non-woven fabrics and GAC inclusion in MSF operation improved performance of this technology with ease of application and operation.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Aim: To determine the immunoreactivity of synthetic Cryptococcus-derived peptides. Materials & methods: A total of 63 B-cell epitopes from previously identified Cryptococcus gattii immunoreactive proteins were synthesized and evaluated as antigens in ELISAs. The peptides were first evaluated for their ability to react against sera from immunocompetent subjects carrying cryptococcal meningitis. Peptides that yielded high sensitivity and specificity in the first test were then retested with sera from individuals with other fungal pathologies for cross-reactivity determination. Results: Six of 63 synthetic peptides were recognized by antibodies in immunoassays, with a specificity of 100%, sensitivity of 78% and low cross-reactivity. Conclusion: We successfully determined the immunoreactivity of selected synthetic peptides of C. gattii derived proteins.
Resumo:
In this work, we analyze a measurement system that will be implanted in a wheels production line, in order to use those wheels for buses and trucks. The measurement device has to be approved according to the MSA study, due to the fact that the mentioned industry is an automobilistic supplier, so that it has to be conform with the ISO/TS 16949 standards. We showed the MSA studies, as well as some concepts for the work understanding. The airlock wheels systematic production is also broached, that is to say, wheels that use airlock tyres, with a better attention given to the rim production, where the device must be implanted. We analyze and assess the data’s acceptance according to the guidelines showed in this study, along with this, improvement proposals are elaborated and their analysis is made, in order to check the obtained results. Finally, we survey the analyzed measurement system, and new studies are suggested, with the intention of improving it
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The steady-state average run length is used to measure the performance of the recently proposed synthetic double sampling (X) over bar chart (synthetic DS chart). The overall performance of the DS X chart in signaling process mean shifts of different magnitudes does not improve when it is integrated with the conforming run length chart, except when the integrated charts are designed to offer very high protection against false alarms, and the use of large samples is prohibitive. The synthetic chart signals when a second point falls beyond the control limits, no matter whether one of them falls above the centerline and the other falls below it; with the side-sensitive feature, the synthetic chart does not signal when they fall on opposite sides of the centerline. We also investigated the steady-state average run length of the side-sensitive synthetic DS X chart. With the side-sensitive feature, the overall performance of the synthetic DS X chart improves, but not enough to outperform the non-synthetic DS X chart. Copyright (C) 2014 John Wiley &Sons, Ltd.
Resumo:
Synthetic-heterodyne demodulation is a useful technique for dynamic displacement and velocity detection in interferometric sensors, as it can provide an output signal that is immune to interferometric drift. With the advent of cost-effective, high-speed real-time signal-processing systems and software, processing of the complex signals encountered in interferometry has become more feasible. In synthetic heterodyne, to obtain the actual dynamic displacement or vibration of the object under test requires knowledge of the interferometer visibility and also the argument of two Bessel functions. In this paper, a method is described for determining the former and setting the Bessel function argument to a set value, which ensures maximum sensitivity. Conventional synthetic-heterodyne demodulation requires the use of two in-phase local oscillators; however, the relative phase of these oscillators relative to the interferometric signal is unknown. It is shown that, by using two additional quadrature local oscillators, a demodulated signal can be obtained that is independent of this phase difference. The experimental interferometer is aMichelson configuration using a visible single-mode laser, whose current is sinusoidally modulated at a frequency of 20 kHz. The detected interferometer output is acquired using a 250 kHz analog-to-digital converter and processed in real time. The system is used to measure the displacement sensitivity frequency response and linearity of a piezoelectric mirror shifter over a range of 500 Hz to 10 kHz. The experimental results show good agreement with two data-obtained independent techniques: the signal coincidence and denominated n-commuted Pernick method.
Resumo:
Objectives: The aim of this study is to report on the treatment of mandibular Class II furcation defects with enamel matrix protein derivative (EMD) combined with a beta TCP/HA (beta-tricalcium phosphate/hydroxyapatite) alloplastic material. Method and Materials: Thirteen patients were selected. All patients were nonsmokers, systemically healthy, and diagnosed with chronic periodontitis; had not taken medications known to interfere with periodontal tissue health and healing; presented one Class II mandibular furcation defect with horizontal probing equal to or greater than 4 mm at buccal site. The clinical parameters evaluated were probing depth (PD), relative gingival margin position (RGMP), relative vertical clinical attachment level (RVCAL), and relative horizontal clinical attachment level (RHCAL). A paired Student t test was used to detect differences between the baseline and 6-month measurements, with the level of significance of .05. Results: After 6 months, the treatment produced a statistically significant reduction in PD and a significant gain in RVCAL and RHCAL, but no observable change in RGMP. RVCAL ranged from 13.77 (+/- 1.31) at baseline to 12.15 (+/- 1.29) after 6 months, with a mean change of -1.62 +/- 1.00 mm (P<.05). RHCAL ranged from 5.54 (+/- 0.75) to 2.92 (+/- 0.92), with a mean change of -2.62 +/- 0.63 mm (P<.05). After 6 months, 76.92% of the patients improved their diagnosis to Class I furcation defects while 23.08% remained as Class II. Conclusion: The present study has shown that positive clinical results may be expected from the combined treatment of Class II furcation defects with EMD and beta TCP/HA, especially considering the gain of horizontal attachment level. Despite this result, controlled clinical studies are needed to confirm our outcomes.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)