982 resultados para solid-phase DNA extraction


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes the development of a sequential injection chromatography (SIC) procedure for separation and quantification of the herbicides simazine, atrazine, and propazine exploring the low backpressure of a 2.5 cm long monolithic C(18) column. The separation of the three compounds was achieved in less than 90 s with resolution > 1.5 using a mobile phase composed by ACN/1.25 mmol/L acetate buffer (pH 4.5) at the volumetric ratio of 35:65 and flow rate of 40 mu L/s. Detection was made at 223 nm using a flow cell with 40 mm of optical path length. The LOD was 10 mu g/L for the three triazines and the quantification limits were of 30 mu g/L for simazine and propazine and 40 mu g/L for atrazine. The sampling frequency is 27 samples per hour, consuming 1.1 mL of ACN per analysis. The proposed methodology was applied to spiked water samples and no statistically significant differences were observed in comparison to a conventional HPLC-UV method. The major metabolites of atrazine and other herbicides did not interfere in the analysis, being eluted from the column either together with the unretained peak, or at retention times well-resolved from the studied compounds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to develop a fast capillary electrophoresis method for the determination of benzoate and sorbate ions in commercial beverages. In the method development the pH and constituents of the background electrolyte were selected using the effective mobility versus pH curves. As the high resolution obtained experimentally for sorbate and benzoate in the studies presented in the literature is not in agreement with that expected from the ionic mobility values published, a procedure to determine these values was carried out. The salicylate ion was used as the internal standard. The background electrolyte was composed of 25 mmol L(-1) tris(hydroxymethyl)aminomethane and 12.5 mmol L(-1) 2-hydroxyisobutyric acid, atpH 8.1.Separation was conducted in a fused-silica capillary(32 cm total length and 8.5 cm effective length, 50 mu m I.D.), with short-end injection configuration and direct UV detection at 200 nm for benzoate and salicylate and 254 nm for sorbate ions. The run time was only 28 s. A few figures of merit of the proposed method include: good linearity (R(2) > 0.999), limit of detection of 0.9 and 0.3 mg L(-1) for benzoate and sorbate, respectively, inter-day precision better than 2.7% (n =9) and recovery in the range 97.9-105%. Beverage samples were prepared by simple dilution with deionized water (1:11, v/v). Concentrations in the range of 197-401 mg L(-1) for benzoate and 28-144 mg L(-1) for sorbate were found in soft drinks and tea. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coupling a liquid core waveguide cell to a sequential injection chromatograph improved the detection limits for determination of triazine herbicides without compromising peak resolution. Separation of simazine, atrazine, and propazine was achieved in water samples by a 25mm long C18 monolithic column. Detection was made at 238nm using a type II LCW (silica capillary coated with Teflon (R) AF2400) cell with 100cm of optical path length. Detection limits for simazine, atrazine, and propazine were 2.3, 1.9, and 4.5 mu g L-1, respectively. Reduced analysis time and low solvent consumption are other remarkable features of the proposed method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The enantiomers of sulfoxide proton pump inhibitors - omeprazole, lansoprazole, rabeprazole and Ro 18-5364 - were enantiomerically separated by liquid chromatography at multimilligram scale on a poly saccharide-based chiral stationary phase using normal and polar organic conditions as mobile phase. The values of the recovery and production rate were significant for each enantiomer; better results were achieved using a solid-phase injection system. However, this system was applied just for the enantionteric separation of omeprazole to demonstrate the applicability of this injection mode at milligram scale. The chiroptical characterization of the compounds was performed using a polarimeter and a circular dichroism detector. The higher enantiomeric purity obtained for the isolated enantiomers suggests that the methods here described should be considered as a simple and rapid way to obtain enantiomeric pure standards for analytical purpose. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Direct analysis, with minimal sample pretreatment, of antidepressant drugs, fluoxetine, imipramine, desipramine, amitriptyline, and nortriptyline in biofluids was developed with a total run time of 8 min. The setup consists of two HPLC pumps, injection valve, capillary RAM-ADS-C18 pre-column and a capillary analytical C 18 column connected by means of a six-port valve in backflush mode. Detection was performed with ESI-MS/MS and only 1 mu m of sample was injected. Validation was adequately carried out using FLU-d(5) as internal standard. Calibration curves were constructed under a linear range of 1-250 ng mL(-1) in plasma, being the limit of quantification (LOQ), determined as 1 ng mL(-1), for all the analytes. With the described approach it was possible to reach a quantified mass sensitivity of 0.3 pg for each analyte (equivalent to 1.1-1.3 fmol), translating to a lower sample consumption (in the order of 103 less sample than using conventional methods). (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A column switching LC method is presented for the analysis of fluoxetine (FLU) and norfluoxetine (NFLU) by direct injection of human plasma using a lab-made restricted access media (RAM) column. A RAM-BSA-octadecyl silica (C-18) column (40 min x 4.6 mm, 10 mu m) is evaluated in both backflush and foreflush elution modes and coupled with a C-18 lab-made (50 mm x 4.6 mm, 3 pm) analytical column in order to perform online sample preparation. Direct injection of 100 mu L, of plasma samples is possible with the developed approach. In addition, reduction of sample handling is obtained when compared with traditional liquid-liquid extraction (LLE) and SPE. The total analysis time is around 20 min. A LOQ of 15 ng/mL is achieved in a concentration range of 15-500 ng/mL, allowing the therapeutic drug monitoring of clinical samples. The precision values achieved are lower than 15% for all the evaluated points with adequate recovery and accuracy. Furthermore, no matrix interferences are found in the analysis and the proposed method shows to be an adequate alternative for analysis of FLU in plasma.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The influence of the sample matrix in the CC-electron-capture detection analysis of the pesticides dimethoate, diazinon, chlorothalonil.. parathion methyl and fenitrothion in fruits samples has been studied. Experiments have been carried out where the pesticide responses in standard solutions prepared in selected solvent were compared with their response when present in apple, mango, papaya, banana, pineapple and melon extracts. The presence of matrix effects (MEs) and their extent were shown to be simultaneously influenced by several factors (matrix concentration, matrix type, pesticide concentration, analytical range). Pronounced MEs were observed particularly for dimethoate and diazinon in all matrices tested; in lower concentrations, all pesticides presented significant ME. The other pesticides presented variable ME. Higher ME enhancement was detected at lower pesticide concentration levels of and/or at higher matrix concentration solutions. The ME detected for fenitrothion, in the analytical range evaluated, were dependent on matrix type. For each pesticide, solvent and matrix-matched calibrations were compared for all fruit samples, and it could be concluded that quantitation based on standard solutions prepared in blank matrix extract (matrix-matched calibration) should be used to compensate the MEs and to obtain more accurate results for the pesticides studied.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method for the determination of pesticide residues in water and sediment was developed using the QuEChERS method followed by gas chromatography - mass spectrometry. The method was validated in terms of accuracy, specificity, linearity, detection and quantification limits. The recovery percentages obtained for the pesticides in water at different concentrations ranged from 63 to 116%, with relative standard deviations below 12%. The corresponding results from the sediment ranged from 48 to 115% with relative standard deviations below 16%. The limits of detection for the pesticides in water and sediment were below 0.003 mg L(-1) and 0.02 mg kg(-1), respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new approach based on microextraction by packed sorbent (MEPS) and reversed-phase high-throughput ultra high pressure liquid chromatography (UHPLC) method that uses a gradient elution and diode array detection to quantitate three biologically active flavonols in wines, myricetin, quercetin, and kaempferol, is described. In addition to performing routine experiments to establish the validity of the assay to internationally accepted criteria (selectivity, linearity, sensitivity, precision, accuracy), experiments are included to assess the effect of the important experimental parameters such as the type of sorbent material (C2, C8, C18, SIL, and C8/SCX), number of extraction cycles (extract-discard), elution volume, sample volume, and ethanol content, on the MEPS performance. The optimal conditions of MEPS extraction were obtained using C8 sorbent and small sample volumes (250 μL) in five extraction cycle and in a short time period (about 5 min for the entire sample preparation step). Under optimized conditions, excellent linearity View the MathML source(Rvalues2>0.9963), limits of detection of 0.006 μg mL−1 (quercetin) to 0.013 μg mL−1 (myricetin) and precision within 0.5–3.1% were observed for the target flavonols. The average recoveries of myricetin, quercetin and kaempferol for real samples were 83.0–97.7% with relative standard deviation (RSD, %) lower than 1.6%. The results obtained showed that the most abundant flavonol in the analyzed samples was myricetin (5.8 ± 3.7 μg mL−1). Quercetin (0.97 ± 0.41 μg mL−1) and kaempferol (0.66 ± 0.24 μg mL−1) were found in a lower concentration. The optimized MEPSC8 method was compared with a reverse-phase solid-phase extraction (SPE) procedure using as sorbent a macroporous copolymer made from a balanced ratio of two monomers, the lipophilic divinylbenzene and the hydrophilic N-vinylpyrrolidone (Oasis HLB) were used as reference. MEPSC8 approach offers an attractive alternative for analysis of flavonols in wines, providing a number of advantages including highest extraction efficiency (from 85.9 ± 0.9% to 92.1 ± 0.5%) in the shortest extraction time with low solvent consumption, fast sample throughput, more environmentally friendly and easy to perform.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This manuscript describes the development and validation of an ultra-fast, efficient, and high throughput analytical method based on ultra-high performance liquid chromatography (UHPLC) equipped with a photodiode array (PDA) detection system, for the simultaneous analysis of fifteen bioactive metabolites: gallic acid, protocatechuic acid, (−)-catechin, gentisic acid, (−)-epicatechin, syringic acid, p-coumaric acid, ferulic acid, m-coumaric acid, rutin, trans-resveratrol, myricetin, quercetin, cinnamic acid and kaempferol, in wines. A 50-mm column packed with 1.7-μm particles operating at elevated pressure (UHPLC strategy) was selected to attain ultra-fast analysis and highly efficient separations. In order to reduce the complexity of wine extract and improve the recovery efficiency, a reverse-phase solid-phase extraction (SPE) procedure using as sorbent a new macroporous copolymer made from a balanced ratio of two monomers, the lipophilic divinylbenzene and the hydrophilic N-vinylpyrrolidone (Oasis™ HLB), was performed prior to UHPLC–PDA analysis. The calibration curves of bioactive metabolites showed good linearity within the established range. Limits of detection (LOD) and quantification (LOQ) ranged from 0.006 μg mL−1 to 0.58 μg mL−1, and from 0.019 μg mL−1 to 1.94 μg mL−1, for gallic and gentisic acids, respectively. The average recoveries ± SD for the three levels of concentration tested (n = 9) in red and white wines were, respectively, 89 ± 3% and 90 ± 2%. The repeatability expressed as relative standard deviation (RSD) was below 10% for all the metabolites assayed. The validated method was then applied to red and white wines from different geographical origins (Azores, Canary and Madeira Islands). The most abundant component in the analysed red wines was (−)-epicatechin followed by (−)-catechin and rutin, whereas in white wines syringic and p-coumaric acids were found the major phenolic metabolites. The method was completely validated, providing a sensitive analysis for bioactive phenolic metabolites detection and showing satisfactory data for all the parameters tested. Moreover, was revealed as an ultra-fast approach allowing the separation of the fifteen bioactive metabolites investigated with high resolution power within 5 min.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The oil and petrochemical industry is responsable to generate a large amount of waste and wastewater. Among some efluents, is possible find the benzene, toluene, ethilbenze and isomers of xilenes compounds, known as BTEX. These compounds are very volatily, toxic for environment and potencially cancerigenous in man. Oxidative advanced processes, OAP, are unconventional waste treatment, wich may be apply on treatment and remotion this compounds. Fenton is a type of OAPs, wich uses the Fenton s reactant, hydrogen peroxide and ferrous salt, to promove the organic degradation. While the Photo-Fenton type uses the Fenton s reactant plus UV radiation (ultraviolet). These two types of OAP, according to literature, may be apply on BTEX complex system. This project consists on the consideration of the utilization of technologies Fenton and Photo-Fenton in aqueous solution in concentration of 100 ppm of BTEX, each, on simulation of condition near of petrochemical effluents. Different reactors were used for each type of OAP. For the analyticals results of amount of remotion were used the SPME technique (solid phase microextraction) for extraction in gaseous phase of these analytes and the gas chromatography/mass espectrometry The arrangement mechanical of Photo-Fenton system has been shown big loss by volatilization of these compounds. The Fenton system has been shown capable of degradate benzene and toluene compounds, with massic percentage of remotion near the 99%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This dissertation aims the development of an experimental device to determine quantitatively the content of benzene, toluene and xylenes (BTX) in the atmosphere. BTX are extremely volatile solvents, and therefore play an important role in atmospheric chemistry, being precursors in the tropospheric ozone formation. In this work a BTX new standard gas was produced in nitrogen for stagnant systems. The aim of this dissertation is to develop a new method, simple and cheaper, to quantify and monitor BTX in air using solid phase microextraction/ gas chromatography/mass spectrometry (SPME/CG/MS). The features of the calibration method proposed are presented in this dissertation. SPME sampling was carried out under non-equilibrium conditions using a Carboxen/PDMS fiber exposed for 10 min standard gas mixtures. It is observed that the main parameters that affect the extraction process are sampling time and concentration. The results of the BTX multicomponent system studied have shown a linear and a nonlinear range. In the non-linear range, it is remarkable the effect of competition by selective adsorption with the following affinity order p-xylene > toluene > benzene. This behavior represents a limitation of the method, however being in accordance with the literature. Furthermore, this behavior does not prevent the application of the technique out of the non-linear region to quantify the BTX contents in the atmosphere.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Biosurfactants are molecules produced by microorganisms mainly bacteria as Pseudomonas and Bacillus. Among the biosurfactants, rhamnolipids play an important role due to their tensoactive as well as emulsifying properties. Besides can be produced in a well consolidated way the production costs of biosurfactants are quite expansive mainly if downstream processing is goning to be considered. Actually, attention has been given to identification of biosurfactants as well as optimization of its fermentative processes including downstream ones. This work deals with the development of strategies to recovery and purification of rhamnolipids produced by Pseudomonas aeruginosa P029-GVIIA using sugar-cane molasses as substrate. Broth free of cells was used in order to investigate the best strategies to recovery and purification produced by this system. Between the studied acids (HCl and H2SO4) for the acid precipitation step, HCl was the best one as has been showed by the experimental design 24. Extraction has been carried out using petroleum ether and quantification has been done using the thioglycolic acid method. Adsorption studies were carried out with activated carbon in a batch mode using a 24 experimental design as well as combined with an hydrophobic resin Streamline Phenyl aiming to separate the produced biosurfactant. Biosurfactant partial identification was carried out using High Performance Liquid Chromatography (HPLC). Experiments in batch mode showed that adsorption has been controlled mainly by pH and temperature. It was observed a reduction of 41.4% for the liquid phase and the solid phase it was possible to adsorb up to 15 mg of rhamnolipd/g of activated carbon. The kinetics of adsorption has been well fitted to a pseudo-first order reaction with velocity constant (k1) of 1.93 x 10-2 min-1. Experiments in packed bed ranging concentration on eluent (acetone) has been shown the highest recovery factor of 98% when pure acetone has been used. The combined effect if using activated carbon with an hydrophobic resin Streamline Phenyl has been shown successful for the rhamnolipids purification. It has been possible to purify a fraction of the crude broth with 98% of purity when the eluted of activated carbon packed bed was used with pure acetone

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work was to identify the degradation compounds produced during irradiation of multilayer polyamide 6 (PA-6) films and to study their migration into water and 95% ethanol food simulant. After irradiation of multilayer PA-6 films at 3, 7 and 12 kGy, degradation compounds were extracted using solid-phase microextraction, for which the time and temperature of extraction and stirring were optimized, and identified by gas chromatography-mass spectrometry. Caprolactam, 2-cyclopentylcyclopentanone and aldehydes, among other compounds, were identified in the headspace of the films. Polydimethylsiloxane was considered the best fiber for extraction. The optimum conditions of time, temperature and stirring to extract the compounds were 20 min, 80 degrees C and 225 rpm. For validation purposes, the compounds were quantified in water and 95% ethanol and the results showed high sensitivity, good precision and accuracy. Migration of compounds from irradiated and non-irradiated multilayer PA-6 films into water and 95% ethanol food simulants was carried out at 40 degrees C for 10 days. The method was efficient for the quantification of decaldehyde, 2-cyclopentylcyclopentanone and caprolactam that migrated from multilayer PA-6 films into food simulants.