968 resultados para signal detection


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aims of this study were a) to assess the ability of primary care doctors to make accurate ratings of psychiatric disturbance and b) to evaluate the use of a case-finding questionnaire in the detection of psychiatric morbidity. The estudy took place in three primary care clinics in the city of São Paulo, Brazil, during a six-month survey. A time sample of consecutive adult attenders were asked to complete a case-finding questionnaire for psychiatric disorders (the Self Report Questionnaire - SRQ) and a subsample were selected for a semi-structured psychiatric interview (the Clinical Interview Schedule - CIS). At the end of the consultation the primary care doctors were asked to assess, in a standardized way, the presence or absence of psychiatric disorder; these assessments were then compared with that ratings obtained in the psychiatric interview. A considerable proportion of minor psychiatric morbidity remained undetected by the three primary care doctors: the hidden morbidity ranged from 22% to 79%. When these were compared to those of the case-finding questionnaire, they were consistently lower, indicating that the use of these instruments can enhance the recognition of psychiatric disorders in primary care settings. Four strategies for adopting the questionnaire are described, and some of the clinical consequences of its use are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A series of studies in the field of Epidemiological Psychiatry have been performed over the last two decades, and these have focused on the ability of primary care physicians to detect emotional disorders in the patients that attend their practices. The scientific methodology utilized in these studies is the subject of this review, which contains a discussion concerning: a) interviewer awareness bias; b) accuracy of the instruments and c) medical and psychological concepts involved in defining minor emotional disorders. Suggestions for change in the methodology are made in each of the sections of the review.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we present results on the optimization of multilayered a-SiC:H heterostructures that can be used as optical transducers for fluorescent proteins detection using the Fluorescence Resonance Energy Transfer approach. Double structures composed by pin based aSiC:H cells are analyzed. The color discrimination is achieved by ac photocurrent measurement under different externally applied bias. Experimental data on spectral response analysis, current-voltage characteristics and color and transmission rate discrimination are reported. An electrical model, supported by a numerical simulation gives insight into the device operation. Results show that the optimized a-SiC:H heterostructures act as voltage controlled optical filters in the visible spectrum. When the applied voltages are chosen appropriately those optical transducers can detect not only the selective excitation of specimen fluorophores, but also the subsequent weak acceptor fluorescent channel emission.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we present an amorphous silicon device that can be used in two operation modes to measure the concentration of ions in solution. While crystalline devices present a higher sensitivity, their amorphous counterpart present a much lower fabrication cost, thus enabling the production of cheap disposable sensors for use, for example, in the food industry. The devices were fabricated on glass substrates by the PECVD technique in the top gate configuration, where the metallic gate is replaced by an electrolytic solution with an immersed Ag/AgCl reference electrode. Silicon nitride is used as gate dielectric enhancing the sensitivity and passivation layer used to avoid leakage and electrochemical reactions. In this article we report on the semiconductor unit, showing that the device can be operated in a light-assisted mode, where changes in the pH produce changes on the measured ac photocurrent. In alternative the device can be operated as a conventional ion selective field effect device where changes in the pH induce changes in the transistor's threshold voltage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cryptosporidium sp., a coccidian parasite usually found in the faeces of cattle, has been recently implicated as an agent of human intestinal disease, mainly in immunocompromised patients. In the study realized, by an indirect immunofluorescence technique, specific immunoglobulins (IgG and IgM) have been demonstrated in human serum against Cryptosporidium oocysts. Purified oocysts were used as antigens in the indirect immunofluorecence assay. After analyzing this test in sera from selected groups of patients, the frequency of both specific IgG and IgM of immunocompetent children who were excreting oocysts in their faeces was 62% and in children with negative excretion of oocysts was 20% and 40%, respectively. In adults infected with the human immunodeficiency virus (HIV) and who were excreting Cryptosporidium in their stools, the frequency was 57% for IgG but only 2% for IgM. Twenty three percent of immunocompromised adults with not determined excretion of oocysts in their stools had anti-Cryptosporidium IgG in their sera. Children infected with human immunodeficiency virus had no IgM and only 14% had IgG detectable in their sera. The indirect immunoflorescence assay, when used with other parasitological techniques appears to be useful for retrospective population studies and for diagnosis of acute infection. The humoral immune response of HIV positive patients to this protozoan agent needs clarification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A motivação para este trabalho vem da necessidade que o autor tem em poder registar as notas tocadas na guitarra durante o processo de improviso. Quando o músico está a improvisar na guitarra, muitas vezes não se recorda das notas tocadas no momento, este trabalho trata o desenvolvimento de uma aplicação para guitarristas, que permita registar as notas tocadas na guitarra eléctrica ou clássica. O sinal é adquirido a partir da guitarra e processado com requisitos de tempo real na captura do sinal. As notas produzidas pela guitarra eléctrica, ligada ao computador, são representadas no formato de tablatura e/ou partitura. Para este efeito a aplicação capta o sinal proveniente da guitarra eléctrica a partir da placa de som do computador e utiliza algoritmos de detecção de frequência e algoritmos de estimação de duração de cada sinal para construir o registo das notas tocadas. A aplicação é desenvolvida numa perspectiva multi-plataforma, podendo ser executada em diferentes sistemas operativos Windows e Linux, usando ferramentas e bibliotecas de domínio público. Os resultados obtidos mostram a possibilidade de afinar a guitarra com valores de erro na ordem de 2 Hz em relação às frequências de afinação standard. A escrita da tablatura apresenta resultados satisfatórios, mas que podem ser melhorados. Para tal será necessário melhorar a implementação de técnicas de processamento do sinal bem como a comunicação entre processos para resolver os problemas encontrados nos testes efectuados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O trabalho apresentado nesta dissertação refere-se à concepção, projecto e realização experimental de um conversor estático de potência tolerante a falhas. Foram analisados trabalhos de investigação sobre modos de falha de conversores electrónicos de potência, topologias de conversores tolerantes a falhas, métodos de detecção de falhas, entre outros. Com vista à concepção de uma solução, foram nomeados e analisados os principais modos de falhas para três soluções propostas de conversores com topologias tolerantes a falhas onde existem elementos redundantes em modo de espera. Foram analisados os vários aspectos de natureza técnica dos circuitos de potência e guiamento de sinais onde se salientam a necessidade de tempos mortos entre os sinais de disparo de IGBT do mesmo ramo, o isolamento galvânico entre os vários andares de disparo, a necessidade de minimizar as auto-induções entre o condensador DC e os braços do conversor de potência. Com vista a melhorar a fiabilidade e segurança de funcionamento do conversor estático de potência tolerante a falhas, foi concebido um circuito electrónico permitindo a aceleração da actuação normal de contactores e outro circuito responsável pelo encaminhamento e inibição dos sinais de disparo. Para a aplicação do conversor estático de potência tolerante a falhas desenvolvido num accionamento com um motor de corrente contínua, foi implementado um algoritmo de controlo numa placa de processamento digital de sinais (DSP), sendo a supervisão e actuação do sistema realizados em tempo-real, para a detecção de falhas e actuação de contactores e controlo de corrente e velocidade do motor utilizando uma estratégia de comando PWM. Foram realizados ensaios que, mediante uma detecção adequada de falhas, realiza a comutação entre blocos de conversores de potência. São apresentados e discutidos resultados experimentais, obtidos usando o protótipo laboratorial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The devastating impact of the Sumatra tsunami of 26 December 2004, raised the question for scientists of how to forecast a tsunami threat. In 2005, the IOC-UNESCO XXIII assembly decided to implement a global tsunami warning system to cover the regions that were not yet protected, namely the Indian Ocean, the Caribbean and the North East Atlantic, the Mediterranean and connected seas (the NEAM region). Within NEAM, the Gulf of Cadiz is the more sensitive area, with an important record of devastating historical events. The objective of this paper is to present a preliminary design for a reliable tsunami detection network for the Gulf of Cadiz, based on a network of sea-level observatories. The tsunamigenic potential of this region has been revised in order to define the active tectonic structures. Tsunami hydrodynamic modeling and GIS technology have been used to identify the appropriate locations for the minimum number of sea-level stations. Results show that 3 tsunameters are required as the minimum number of stations necessary to assure an acceptable protection to the large coastal population in the Gulf of Cadiz. In addition, 29 tide gauge stations could be necessary to fully assess the effects of a tsunami along the affected coasts of Portugal, Spain and Morocco.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Results on the use of a double a-SiC:H p-i-n heterostructure for signal multiplexing and demultiplexing applications in the visible range are presented. Pulsed monochromatic beams together (multiplexing mode), or a single polychromatic beam (demultiplexing mode) impinge on the device and are absorbed, accordingly to their wavelength. Red, green and blue pulsed input channels are transmitted together, each one with a specific transmission rate. The combined optical signal is analyzed by reading out, under different applied voltages, the generated photocurrent. Results show that in the multiplexing mode the output signal is balanced by the wavelength and transmission rate of each input channel, keeping the memory of the incoming optical carriers. In the demultiplexing mode the photocurrent is controlled by the applied voltage allowing regaining the transmitted information. A physical model supported by a numerical simulation gives insight into the device operation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ZnO:Al/p (SiC:H)/i (Si:H)/n (SiC:H) large area image and colour sensor are analysed. Carrier transport and collection efficiency are investigated from dark and illuminated current-voltage (I-V) dependence and spectral response measurements under different optical and electrical bias conditions. Results show that the carrier collection depends on the optical bias and on the applied voltage. By changing the electrical bias around the open circuit voltage it is possible to filter the absorption at a given wavelength and so to tune the spectral sensitivity of the device. Transport and optical modelling give insight into the internal physical process and explain the bias control of the spectral response and the image and colour sensing properties of the devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study the implications for two-Higgs-doublet models of the recent announcement at the LHC giving a tantalizing hint for a Higgs boson of mass 125 GeV decaying into two photons. We require that the experimental result be within a factor of 2 of the theoretical standard model prediction, and analyze the type I and type II models as well as the lepton-specific and flipped models, subject to this requirement. It is assumed that there is no new physics other than two Higgs doublets. In all of the models, we display the allowed region of parameter space taking the recent LHC announcement at face value, and we analyze the W+W-, ZZ, (b) over barb, and tau(+)tau(-) expectations in these allowed regions. Throughout the entire range of parameter space allowed by the gamma gamma constraint, the numbers of events for Higgs decays into WW, ZZ, and b (b) over bar are not changed from the standard model by more than a factor of 2. In contrast, in the lepton-specific model, decays to tau(+)tau(-) are very sensitive across the entire gamma gamma-allowed region.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVES: To detect anti-Giardia lamblia serum antibodies in healthy children attending public day care centers and to assess serological tests as tools for estimating the prevalence of G. lamblia in endemic areas. METHODS: Three separate stool specimens and filter paper blood samples were collected from 147 children ranging from 0 to 6 years old. Each stool sample was processed using spontaneous sedimentation and zinc sulfate flotation methods. Blood samples were tested by indirect immunofluorescence (IIF) and enzyme-linked immunosorbent assay (ELISA) for Giardia IgG. RESULTS AND CONCLUSIONS: Of 147 individuals tested, 93 (63.3%) showed Giardia cysts in their feces. Using IIF and ELISA, serum antibodies were detected in 93 (63.3%) and 100 (68%) samples , respectively. Sensitivity of IIF and ELISA was 82% and 72%, respectively. However, ELISA revealed to be less specific (39%) than IIF (70%). IIF also showed a higher concordance with microscopic examination than ELISA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optical colour sensors based on multilayered a-SiC:H heterostructures can act as voltage controlled optical filters in the visible range. In this article we investigate the application of these structures for Fluorescence Resonance Energy Transfer (FRET) detection, The characteristics of a-SiC:H multilayered structure are studied both theoretically and experimentally in several wavelengths corresponding to different fluorophores. The tunable optical p-i'(a-SiC:H)-n/p-i(a-Si:H)-n heterostructures were produced by PECVD and tested for a proper fine tuning in the violet, cyan and yellow wavelengths. The devices were characterized through transmittance and spectral response measurements, under different electrical bias and frequencies. Violet, cyan and yellow signals were applied in simultaneous and results have shown that they can be recovered under suitable applied bias. A theoretical analysis supported by numerical simulation is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The characteristics of tunable wavelength filters based on a-SiC:H multilayered stacked pin cells are studied both theoretically and experimentally. The optical transducers were produced by PECVD and tested for a proper fine tuning of the cyan and yellow fluorescent proteins emission. The active device consists of a p-i'(a-SiC:H)-n/p-i(a-Si:H)-n heterostructures sandwiched between two transparent contacts. Experimental data on spectral response analysis, current-voltage characteristics and color and transmission rate discrimination are reported. Cyan and yellow fluorescent input channels were transmitted together, each one with a specific transmission rate and different intensities. The multiplexed optical signal was analyzed by reading out, under positive and negative applied voltages, the generated photocurrents. Results show that the optimized optical transducer has the capability of combining the transient fluorescent signals onto a single output signal without losing any specificity (color and intensity). It acts as a voltage controlled optical filter: when the applied voltages are chosen appropriately the transducer can select separately the cyan and yellow channel emissions (wavelength and frequency) and also to quantify their relative intensities. A theoretical analysis supported by a numerical simulation is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To comparatively detect A. actinomycetemcomitans and F. nucleatum from periodontal and healthy sites. METHODS: Subgingival clinical samples from 50 periodontitis adult patients and 50 healthy subjects were analyzed. Both organisms were isolated using a trypticase soy agar-bacitracin-vancomycin (TSBV) medium and detected by PCR. Conventional biochemical tests were used for bacteria identification. RESULTS: A. actinomycetemcomitans and F. nucleatum were isolated in 18% and 20% of the patients, respectively, and in 2% and 24% of healthy subjects. Among A. actinomycetemcomitans isolates, biotype II was the most prevalent. Primer pair AA was 100% sensitive in the detection of A. actinomycetemcomitans from both subject groups. Primers ASH and FU were also 100% sensitive to detect this organism in healthy subject samples. Primer pair FN5047 was more sensitive to detect F. nucleatum in patients or in healthy samples than primer 5059S. Primers ASH and 5059S were more specific in the detection of A. actinomycetemcomitans and F. nucleatum, respectively, in patients and in healthy subject samples. CONCLUSIONS: PCR is an effective tool for detecting periodontal pathogens in subgingival samples, providing a faster and safer diagnostic tool of periodontal diseases. The method's sensitivity and specificity is conditioned by the choice of the set of primers used.