999 resultados para radiation variability
Resumo:
Computed tomography (CT) is a modality of choice for the study of the musculoskeletal system for various indications including the study of bone, calcifications, internal derangements of joints (with CT arthrography), as well as periprosthetic complications. However, CT remains intrinsically limited by the fact that it exposes patients to ionizing radiation. Scanning protocols need to be optimized to achieve diagnostic image quality at the lowest radiation dose possible. In this optimization process, the radiologist needs to be familiar with the parameters used to quantify radiation dose and image quality. CT imaging of the musculoskeletal system has certain specificities including the focus on high-contrast objects (i.e., in CT of bone or CT arthrography). These characteristics need to be taken into account when defining a strategy to optimize dose and when choosing the best combination of scanning parameters. In the first part of this review, we present the parameters used for the evaluation and quantification of radiation dose and image quality. In the second part, we discuss different strategies to optimize radiation dose and image quality at CT, with a focus on the musculoskeletal system and the use of novel iterative reconstruction techniques.
Resumo:
In radionuclide metrology, Monte Carlo (MC) simulation is widely used to compute parameters associated with primary measurements or calibration factors. Although MC methods are used to estimate uncertainties, the uncertainty associated with radiation transport in MC calculations is usually difficult to estimate. Counting statistics is the most obvious component of MC uncertainty and has to be checked carefully, particularly when variance reduction is used. However, in most cases fluctuations associated with counting statistics can be reduced using sufficient computing power. Cross-section data have intrinsic uncertainties that induce correlations when apparently independent codes are compared. Their effect on the uncertainty of the estimated parameter is difficult to determine and varies widely from case to case. Finally, the most significant uncertainty component for radionuclide applications is usually that associated with the detector geometry. Recent 2D and 3D x-ray imaging tools may be utilized, but comparison with experimental data as well as adjustments of parameters are usually inevitable.
Resumo:
This study investigated changes in heart rate variability (HRV) in elite Nordic-skiers to characterize different types of "fatigue" in 27 men and 30 women surveyed from 2004 to 2008. R-R intervals were recorded at rest during 8 min supine (SU) followed by 7 min standing (ST). HRV parameters analysed were powers of low (LF), high (HF) frequencies, (LF+HF) (ms(2)) and heart rate (HR, bpm). In the 1 063 HRV tests performed, 172 corresponded to a "fatigue" state and the first were considered for analysis. 4 types of "fatigue" (F) were identified: 1. F(HF(-)LF(-))SU_ST for 42 tests: decrease in LFSU (- 46%), HFSU (- 70%), LFST (- 43%), HFST (- 53%) and increase in HRSU (+ 15%), HRST (+ 14%). 2. F(LF(+) SULF(-) ST) for 8 tests: increase in LFSU (+ 190%) decrease in LFST (- 84%) and increase in HRST (+ 21%). 3. F(HF(-) SUHF(+) ST) for 6 tests: decrease in HFSU (- 72%) and increase in HFST (+ 501%). 4. F(HF(+) SU) for only 1 test with an increase in HFSU (+ 2161%) and decrease in HRSU (- 15%). Supine and standing HRV patterns were independently modified by "fatigue". 4 "fatigue"-shifted HRV patterns were statistically sorted according to differently paired changes in the 2 postures. This characterization might be useful for further understanding autonomic rearrangements in different "fatigue" conditions.
Resumo:
OBJECTIVE: EEG is widely used to predict outcome in comatose cardiac arrest patients, but its value has been limited by lack of a uniform classification. We used the EEG terminology proposed by the American Clinical Neurophysiology Society (ACNS) to assess interrater variability in a cohort of cardiac arrest patients included in the Target Temperature Management trial. The main objective was to evaluate if malignant EEG-patterns could reliably be identified. METHODS: Full-length EEGs from 103 comatose cardiac arrest patients were interpreted by four EEG-specialists with different nationalities who were blinded for patient outcome. Percent agreement and kappa (κ) for the categories in the ACNS EEG terminology and for prespecified malignant EEG-patterns were calculated. RESULTS: There was substantial interrater agreement (κ 0.71) for highly malignant patterns and moderate agreement (κ 0.42) for malignant patterns. Substantial agreement was found for malignant periodic or rhythmic patterns (κ 0.72) while agreement for identifying an unreactive EEG was fair (κ 0.26). CONCLUSIONS: The ACNS EEG terminology can be used to identify highly malignant EEG-patterns in post cardiac arrest patients in an international context with high reliability. SIGNIFICANCE: The establishment of strict criteria with high transferability between interpreters will increase the usefulness of routine EEG to assess neurological prognosis after cardiac arrest.
Resumo:
Computed tomography (CT) is a modality of choice for the study of the musculoskeletal system for various indications including the study of bone, calcifications, internal derangements of joints (with CT arthrography), as well as periprosthetic complications. However, CT remains intrinsically limited by the fact that it exposes patients to ionizing radiation. Scanning protocols need to be optimized to achieve diagnostic image quality at the lowest radiation dose possible. In this optimization process, the radiologist needs to be familiar with the parameters used to quantify radiation dose and image quality. CT imaging of the musculoskeletal system has certain specificities including the focus on high-contrast objects (i.e., in CT of bone or CT arthrography). These characteristics need to be taken into account when defining a strategy to optimize dose and when choosing the best combination of scanning parameters. In the first part of this review, we present the parameters used for the evaluation and quantification of radiation dose and image quality. In the second part, we discuss different strategies to optimize radiation dose and image quality of CT, with a focus on the musculoskeletal system and the use of novel iterative reconstruction techniques.
Resumo:
BACKGROUND: The most important adverse effect of BoNT-A is the systemic diffusion of the toxin. There is some evidence that the administration of high doses can increase the risk of systemic diffusion and the development of clinically evident adverse effects, however an international consensus does not exist about its maximum dose. AIM: The aim of this study was to evaluate changes in autonomic heart drive induced by high doses (higher than 600 units) of incobotulinumtoxinA injection in spastic stroke patients. Moreover, the treatment safety by monitoring adverse events occurrence was assessed. DESIGN: Case control study. POPULATION: Eleven stroke survivors with spastic hemiplegia. METHODS: Patients were treated with intramuscular focal injections of IncobotulinumtoxinA (NT 201; Xeomin®, Merz Pharmaceuticals GmbH, Frankfurt, Germany). Doses were below 12 units/Kg. Each patient underwent an ECG recording before injection and 10 days after treatment. Linear and non-linear Heart Rate variability (HRV) measures were derived from ECGs with a dedicated software. RESULTS: None of the variable considered showed statistically significant changes after BoNT-A injection. CONCLUSION: The use of incobotulinumtoxinA in adult patients at doses up to 12 units/kg seems to be safe regarding autonomic heart drive. CLINICAL REHABILITATION IMPACT: The use of IncobotulinumtoxinA up to 600 units could be a safe therapeutic option in spastic hemiplegic stroke survivors.
Ambient radiation levels in positron emission tomography/computed tomography (PET/CT) imaging center
Resumo:
Objective: To evaluate the level of ambient radiation in a PET/CT center. Materials and Methods: Previously selected and calibrated TLD-100H thermoluminescent dosimeters were utilized to measure room radiation levels. During 32 days, the detectors were placed in several strategically selected points inside the PET/CT center and in adjacent buildings. After the exposure period the dosimeters were collected and processed to determine the radiation level. Results: In none of the points selected for measurements the values exceeded the radiation dose threshold for controlled area (5 mSv/year) or free area (0.5 mSv/year) as recommended by the Brazilian regulations. Conclusion: In the present study the authors demonstrated that the whole shielding system is appropriate and, consequently, the workers are exposed to doses below the threshold established by Brazilian standards, provided the radiation protection standards are followed.
Resumo:
AbstractObjective:In the present study, the authors investigated the in vitrobehavior of radio-resistant breast adenocarcinoma (MDA-MB-231) cells line and radiosensitive peripheral blood mononuclear cells (PBMC), as a function of different radiation doses, dose rates and postirradiation time kinetics, with a view to the interest of clinical radiotherapy.Materials and Methods:The cells were irradiated with Co-60, at 2 and 10 Gy and two different exposure rates, 339.56 cGy.min–1 and the other corresponding to one fourth of the standard dose rates, present over a 10-year period of cobalt therapy. Post-irradiation sampling was performed at pre-established kinetics of 24, 48 and 72 hours. The optical density response in viability assay was evaluated and a morphological analysis was performed.Results:Radiosensitive PBMC showed decrease in viability at 2 Gy, and a more significant decrease at 10 Gy for both dose rates. MDAMB- 231 cells presented viability decrease only at higher dose and dose rate. The results showed MDA-MB-231 clone expansion at low dose rate after 48–72 hours post-radiation.Conclusion:Low dose rate shows a possible potential clinical impact involving decrease in management of radio-resistant and radiosensitive tumor cell lines in cobalt therapy for breast cancer.
Resumo:
AbstractObjective:To assess the reduction of estimated radiation dose in abdominal computed tomography following the implementation of new scan protocols on the basis of clinical suspicion and of adjusted images acquisition parameters.Materials and Methods:Retrospective and prospective review of reports on radiation dose from abdominal CT scans performed three months before (group A – 551 studies) and three months after (group B – 788 studies) implementation of new scan protocols proposed as a function of clinical indications. Also, the images acquisition parameters were adjusted to reduce the radiation dose at each scan phase. The groups were compared for mean number of acquisition phases, mean CTDIvol per phase, mean DLP per phase, and mean DLP per scan.Results:A significant reduction was observed for group B as regards all the analyzed aspects, as follows: 33.9%, 25.0%, 27.0% and 52.5%, respectively for number of acquisition phases, CTDIvol per phase, DLP per phase and DLP per scan (p < 0.001).Conclusion:The rational use of abdominal computed tomography scan phases based on the clinical suspicion in conjunction with the adjusted images acquisition parameters allows for a 50% reduction in the radiation dose from abdominal computed tomography scans.