977 resultados para nuclear resonance, medical diagnostic, lung
Resumo:
Magnetic resonance (MR) imaging has been used to analyse and evaluate the vocal tract shape through different techniques and with promising results in several fields. Our purpose is to demonstrate the relevance of MR and image processing for the vocal tract study. The extraction of contours of the air cavities allowed the set - up of a number of 3D reconstruction image stacks by means of the combination of orthogonally oriented sets of slices for e ach articulatory gesture, as a new approach to solve the expected spatial under sampling of the imaging process. In result these models give improved information for the visualization of morphologic and anatomical aspects and are useful for partial measure ments of the vocal tract shape in different situations. Potential use can be found in Medical and therapeutic applications as well as in acoustic articulatory speech modelling.
Resumo:
The first and second authors would like to thank the support of the PhD grants with references SFRH/BD/28817/2006 and SFRH/PROTEC/49517/2009, respectively, from Fundação para a Ciência e Tecnol ogia (FCT). This work was partially done in the scope of the project “Methodologies to Analyze Organs from Complex Medical Images – Applications to Fema le Pelvic Cavity”, wi th reference PTDC/EEA- CRO/103320/2008, financially supported by FCT.
Resumo:
Mestrado em Gestão e Avaliação de Tecnologias em Saúde
Resumo:
Introdução – O melanoma maligno cutâneo (MMC) é considerado uma das mais letais neoplasias e no seu seguimento recorre-se, para além dos exames clínicos e da análise de marcadores tumorais, a diversos métodos imagiológicos, como é o exame Tomografia por Emissão de Positrões/Tomografia Computorizada (PET/CT, do acrónimo inglês Positron Emission Tomography/Computed Tomography) com 18fluor-fluorodeoxiglucose (18F-FDG). O presente estudo tem como objetivo avaliar a utilidade da PET/CT relativamente à análise da extensão e à suspeita de recidiva do MMC, comparando os achados imagiológicos com os descritos em estudos CT. Metodologia – Estudo retrospetivo de 62 estudos PET/CT realizados em 50 pacientes diagnosticados com MMC. Excluiu-se um estudo cujo resultado era duvidoso (nódulo pulmonar). As informações relativas aos resultados dos estudos anatomopatológicos e dos exames imagiológicos foram obtidas através da história clínica e dos relatórios médicos dos estudos CT e PET/CT. Foi criada uma base de dados com os dados recolhidos através do software Excel e foi efetuada uma análise estatística descritiva. Resultados – Dos estudos PET/CT analisados, 31 foram considerados verdadeiros positivos (VP), 28 verdadeiros negativos (VN), um falso positivo (FP) e um falso negativo (FN). A sensibilidade, especificidade, o valor preditivo positivo (VPP), o valor preditivo negativo (VPN) e a exatidão da PET/CT para o estadiamento e avaliação de suspeita de recidiva no MMC são, respetivamente, 96,9%, 96,6%, 96,9%, 96,6% e 96,7%. Dos resultados da CT considerados na análise estatística, 14 corresponderam a VP, 12 a VN, três a FP e cinco a FN. A sensibilidade, especificidade, o VPP e o VPN e a exatidão da CT para o estadiamento e avaliação de suspeita de recidiva no MMC são, respetivamente, 73,7%, 80,0%, 82,4%, 70,6% e 76,5%. Comparativamente aos resultados CT, a PET/CT permitiu uma mudança na atitude terapêutica em 23% dos estudos. Conclusão – A PET/CT é um exame útil na avaliação do MMC, caracterizando-se por uma maior acuidade diagnóstica no estadiamento e na avaliação de suspeita de recidiva do MMC comparativamente à CT isoladamente.
Resumo:
This paper analyses the provision of auxiliary clinical services that are typically carried out within the hospital. We estimate a exible cost function for the three most important (cost- wise) diagnostic techniques and therapeutic services in Portuguese hospitals: Clinical Pathology, Medical Imaging and Physical Medicine and Rehabilitation. Our objective in carrying out this estimation is the evaluation of economies of scale and scope in the provision of these services. For all services, we nd evidence of ray economies of scale and some evidence of economies of scope. These results have important policy implications and can be related to the ongoing discussion of where and how should hospitals provide these services.
Resumo:
Semi quantification (SQ) in DaTScan® studies is broadly used in clinic daily basis, however there is a suspicious about its discriminative capability, and concordance with the diagnostic classification performed by the physician. Aim: Evaluate the discriminate capability of an adapted database and reference's values of healthy controls for the Dopamine Transporters (DAT) with 123I–FP-IT named DBRV adapted to Nuclear Medicine Department's protocol and population of Infanta Cristina's Hospital, and its concordance with the physician classification.
Resumo:
Background - Medical image perception research relies on visual data to study the diagnostic relationship between observers and medical images. A consistent method to assess visual function for participants in medical imaging research has not been developed and represents a significant gap in existing research. Methods - Three visual assessment factors appropriate to observer studies were identified: visual acuity, contrast sensitivity, and stereopsis. A test was designed for each, and 30 radiography observers (mean age 31.6 years) participated in each test. Results - Mean binocular visual acuity for distance was 20/14 for all observers. The difference between observers who did and did not use corrective lenses was not statistically significant (P = .12). All subjects had a normal value for near visual acuity and stereoacuity. Contrast sensitivity was better than population norms. Conclusion - All observers had normal visual function and could participate in medical imaging visual analysis studies. Protocols of evaluation and populations norms are provided. Further studies are necessary to understand fully the relationship between visual performance on tests and diagnostic accuracy in practice.
Resumo:
Introduction: Anxiety is a common problem in primary care and specialty medical settings. Treating an anxious patient takes more time and adds stress to staff. Unrecognized anxiety may lead to exam repetition, and impedance of exam performance. Objective: The aim of the study was to examine the anxiety levels of patients who are to undergo diagnostic exams related to cancer diagnostic: PET/CT and mammography. Methods: Two hundred and thirty two patients who undergo PET/CT and one hundred thirteen women who undergo mammography filled out one questionnaire after the procedure to determine their concerns, expectations and perceptions of anxiety. Results: Our results show that the main causes of anxiety in patients who are having a PET/CT is the fear of the procedure itself and fear of the results. Patients who suffered from greater anxiety were those who were scanned during the initial stage of an oncological disease. On the other hand, the diagnostic is the main cause of anxiety in women who are requiring a mammography. 28% of the women reported having experienced pain or intense pain. Conclusions: The performance of diagnostic exams related to cancer diagnostic like a PET/CT and a mammography are important and statistically generators of anxiety. Patients are often poorly informed and present with a range of anxieties that may ultimately affect examination quality. These results provide expertise that can be used in the development of future training programs to integrate post-graduate courses of health professionals.
Resumo:
Introduction: Standard Uptake Value (SUV) is a measurement of the uptake in a tumour normalized on the basis of a distribution volume and is used to quantify 18F-Fluorodeoxiglucose (FDG) uptake in tumors, such as primary lung tumor. Several sources of error can affect its accuracy. Normalization can be based on body weight, body surface area (BSA) and lean body mass (LBM). The aim of this study is to compare the influence of 3 normalization volumes in the calculation of SUV: body weight (SUVW), BSA (SUVBSA) and LBM (SUVLBM), with and without glucose correction, in patients with known primary lung tumor. The correlation between SUV and weight, height, blood glucose level, injected activity and time between injection and image acquisition is evaluated. Methods: Sample included 30 subjects (8 female and 22 male) with primary lung tumor, with clinical indication for 18F-FDG Positron Emission Tomography (PET). Images were acquired on a Siemens Biography according to the department’s protocol. Maximum pixel SUVW was obtained for abnormal uptake focus through semiautomatic VOI with Quantification 3D isocontour (threshold 2.5). The concentration of radioactivity (kBq/ml) was obtained from SUVW, SUVBSA, SUVLBM and the glucose corrected SUV were mathematically obtained. Results: Statistically significant differences between SUVW, SUVBSA and SUVLBM and between SUVWgluc, SUVBSAgluc and SUVLBMgluc were observed (p=0.000<0.05). The blood glucose level showed significant positive correlations with SUVW (r=0.371; p=0.043) and SUVLBM (r=0.389; p=0.034). SUVBSA showed independence of variations with the blood glucose level. Conclusion: The measurement of a radiopharmaceutical tumor uptake normalized on the basis of different distribution volumes is still variable. Further investigation on this subject is recommended.
Resumo:
Os métodos utilizados pela Medicina moderna no âmbito da Imagem Molecular e na sua capacidade de diagnosticar a partir da “Função do Orgão” em vez da “Morfologia do Orgão”, vieram trazer á componente fundamental desta modalidade da Imagiologia Médica – A Medicina Nuclear – uma importância acrescida, que se tem traduzido num aumento significativo no recurso á sua utilização nas diferentes formas das suas aplicações clínicas. Para além dos aspectos meramente clínicos, que só por si seriam suficientes para ocupar várias dissertações como a presente; a própria natureza desta técnica de imagem, com a sua inerente baixa resolução e tempos longos de aquisição, vieram trazer preocupações acrescidas quanto ás questões relacionadas com a produtividade (nº de estudos a realizar por unidade de tempo); com a qualidade (aumento da resolução da imagem obtida) e, com os níveis de actividade radioactiva injectada nos pacientes (dose de radiação efectiva sobre as populações). Conhecidas que são então as limitações tecnológicas associadas ao desenho dos equipamentos destinados á aquisição de dados em Medicina Nuclear, que apesar dos avanços introduzidos, mantêm mais ou menos inalteráveis os conceitos base de funcionamento de uma Câmara Gama, imaginou-se a alteração significativa dos parâmetros de aquisição (tempo, resolução, actividade), actuando não ao nível das condições técnico-mecânicas dessa aquisição, mas essencialmente ao nível do pós-processamento dos dados adquiridos segundo os métodos tradicionais e que ainda constituem o estado da arte desta modalidade. Este trabalho tem então como objectivo explicar por um lado, com algum pormenor, as bases tecnológicas que desde sempre têm suportado o funcionamento dos sistemas destinados á realização de exames de Medicina Nuclear, mas sobretudo, apresentar as diferenças com os inovadores métodos, que aplicando essencialmente conhecimento (software), permitiram responder ás questões acima levantadas.
Resumo:
Dissertation to Obtain the Degree of Master in Biomedical Engineering
Resumo:
Neuroschistosomiasis (NS) is the second most common form of presentation of infection by the trematode, Schistosoma mansoni. Granulomatous inflammatory reaction occurs as a result of schistosome eggs being transmitted to spinal cord or brain via the vascular system, or by inadvertent adult worm migration to these organs. The two main clinical syndromes are spinal cord neuroschistosomiasis (acute or subacute myelopathy) and localized cerebral or cerebellar neuroschistosomiasis (focal CNS impairment, seizures, increased intracranial pressure). Presumptive diagnosis of NS requires confirming the presence of S. mansoni infection by stool microscopy or rectal biopsy for trematode eggs, and serologic testing of blood and spinal fluid. The localized lesions are identified by signs and symptoms, and confirmed by imaging techniques (contrast myelography, CT and MRI). Algorithms are presented to allow a stepwise approach to diagnosis.
Resumo:
Neste trabalho foi desenvolvido um estudo detalhado dos equipamentos de imagiologia médica, que recorrem ao uso de radiação-X, bem como da ressonância magnética. No seguimento deste estudo foram realizadas diversas atividades com equipamentos reais, desde instalações, reparações, manutenções, até ao seu desmantelamento. Este tipo de atividade permitiu ter uma melhor perceção do funcionamento de cada equipamento e o tipo de trabalho que é realizado por um engenheiro eletrotécnico na PHILIPS no sector healthcare. Durante estas atividades foi possível fazer um estudo da qualidade de imagem, em termos de fatores geométricos, em que foi estudada a distorção, a ampliação e a penumbra de uma imagem. Todos estes parâmetros foram alvos de estudo de forma a poder obter imagens com grande qualidade, mas sem que seja comprometida a saúde do doente, devido à elevada exposição de radiação que corpo humano pode absorver. Este estudo tem como intuito perceber como é que a variação de certos parâmetros irá alterar a qualidade da imagem. Desta forma pretende-se perceber como podem ser calibrados os equipamentos de diagnóstico por imagem, para que o técnico de diagnóstico e terapêutica apenas tenha de indicar qual a parte do corpo humano a radiografar, sendo que a máquina se coloca automaticamente nos parâmetros pré-definidos sem qualquer intervenção humana.
Resumo:
A 64-year-old apparently immunocompetent white man developed lung and brain lesions of disseminated cryptococcosis. The radiologic features mimicked those of lung cancer metastatic to the central nervous system. C. gattii was recovered from cultures of bronchoalveolar lavage fluid, brain biopsy, and blood. The same fungus was recovered from pulmonary and brain specimens at autopsy. Serum and cerebrospinal fluid cryptococcal antigen tests were diagnostic in our case and should be included in the diagnostic evaluation of unexplained pulmonary and cerebral lesions. A literature search showed few reports of fungemia by this species of Cryptococcus, contrasting to C. neoformans.
Resumo:
A significant number of Brazilian gestational-age women are still not tested for HIV, representing a high risk of transmission to their newborns. The current study sought to identify the number of pregnant women with no previous testing or undocumented for HIV referred to the Gynecology and Obstetrics Department of a Regional Teaching Hospital and included diagnosis of HIV infection determined by a rapid test and perinatal transmission in pregnancy. Medical records of all pregnant women admitted to hospital from January 2001 to December 2005 were reviewed. Pregnant women without HIV results were submitted to a rapid HIV test. Those who tested positive were further tested by ELISA and confirmed by indirect immunofluorescence assay (IIA) or Western blot (WB). The viral load from babies born to HIV-infected mothers was assessed by bDNA. Of the 16,424 pregnant women analyzed (6.6%), 1,089 were undocumented for HIV. Eleven women were positive in rapid testing and 10 were confirmed by ELISA, IIA or WB, with 0.9% seropositivity. Mother/infant pairs received zidovudine monotherapy prophylaxis and infant viral load was lower than 50 copies/mL. A higher number of pregnant women previously tested for HIV during antenatal care was verified, compared to that obtained nationwide.