984 resultados para mobility group a2
Resumo:
PH Health Protection Sub-Group Interim Report January 2006
Resumo:
Cleusonite, (Pb,Sr)(U4+,U6+) (Fe2+,Zn)(2) (Ti,Fe2+,Fe3+)(18) (O,OH)(38), is a new member of the crichtonite group. It was found at two occurrences in greenschist facies metamorphosed gneissic series of the Mont Fort and Siviez-Mischabel Nappes in Valais, Switzerland (Cleuson and Bella Tolla summit), and named after the type locality. It occurs as black opaque cm-sized tabular crystals with a bright sub-metallic lustre. The crystals consist of multiple rhombohedra and hexagonal prisms that are generally twinned. Measured density is 4.74(4) g/cm(3) and can be corrected to 4.93(12) g/cm(3) for macroscopic swelling due to radiation damage; the calculated density varies from 5.02(6) (untreated) to 5.27(5) (heat-treated crystals); the difference is related to the cell swelling due to the metamictisation. The empirical formula for cleusonite from Cleuson is (Pb0.89Sr0.12)(Sigma=1.01) (U0.79+4U0.30+6)(Sigma=1.09) (Fe1.91+2Zn0.09)(Sigma=2.00) (Ti11.80Fe3.44+2Fe2.33+3V0.19+5Mn0.08Al0.07)(Sigma=17.90) [O-35.37(OH)(2.63)](Sigma=38). Cations were measured by electron microprobe, the presence of structural (OH) was confirmed by infrared spectroscopy and the U6+/U4+ and Fe2+/Fe3+ ratios were determined by X-ray photoelectron spectroscopy. Cleusonite is partly metamict, and untreated crystals only show three major X-ray diffraction peaks. Because of this radiation-damaged state, the mineral appears optically isotropic and shows a light-grey to white colour in reflected polarized light. Cleusonite is trigonal, space group R $(3) over bar $, and unit-cell parameters are varying from a = 10.576(3), c = 21.325(5) angstrom (untreated crystal) to a = 10.4188(6), c = 20.942(1) angstrom (800 degrees C treatment) and to a = 10.385(2), c = 20.900(7) angstrom (1000 degrees C treatment). The three cells give a common axial ratio 2.01 (1), which is identical to the measured morphological one 2.04(6). ne name cleusonite also applies to the previously described ``uranium-rich senaite'' from Alinci (Macedonia) and the ``plumbodavidite'' from Huanglongpu (China).
Resumo:
Terms of Reference
Resumo:
The treatment of wounds is a challenge that caregivers of all specialities encounter daily in the care of an ageing population and chronically ill patients. An interdisciplinary group has been created in recent years within the Hospices-CHUV to assist caregivers in their care of patients with wounds. This group has developed a variety of tools to assist decision-making and offers a range of continuing education for those employees involved in wound care. The authors describe the approach of the group and the documents produced during the first two years of experience.
Resumo:
OBJECTIVE: Quality assurance (QA) in clinical trials is essential to ensure treatment is safely and effectively delivered. As QA requirements have increased in complexity in parallel with evolution of radiation therapy (RT) delivery, a need to facilitate digital data exchange emerged. Our objective is to present the platform developed for the integration and standardization of QART activities across all EORTC trials involving RT. METHODS: The following essential requirements were identified: secure and easy access without on-site software installation; integration within the existing EORTC clinical remote data capture system; and the ability to both customize the platform to specific studies and adapt to future needs. After retrospective testing within several clinical trials, the platform was introduced in phases to participating sites and QART study reviewers. RESULTS: The resulting QA platform, integrating RT analysis software installed at EORTC Headquarters, permits timely, secure, and fully digital central DICOM-RT based data review. Participating sites submit data through a standard secure upload webpage. Supplemental information is submitted in parallel through web-based forms. An internal quality check by the QART office verifies data consistency, formatting, and anonymization. QART reviewers have remote access through a terminal server. Reviewers evaluate submissions for protocol compliance through an online evaluation matrix. Comments are collected by the coordinating centre and institutions are informed of the results. CONCLUSIONS: This web-based central review platform facilitates rapid, extensive, and prospective QART review. This reduces the risk that trial outcomes are compromised through inadequate radiotherapy and facilitates correlation of results with clinical outcomes.
Resumo:
The Melan-A/MART-1(26-35) antigenic peptide is one of the best studied human tumor-associated antigens. It is expressed in healthy melanocytes and malignant melanoma and is recognized by CD8(+) T cells in the context of the MHC class I molecule HLA-A*0201. While an unusually large repertoire of CD8(+) T cells specific for this antigen has been documented, the reasons for its generation have remained elusive. In this issue of the European Journal of Immunology, Pinto et al. [Eur. J. Immunol. 2014. 44: 2811-2821] uncover one important mechanism by comparing the thymic expression of the Melan-A gene to that in the melanocyte lineage. This study shows that medullary thymic epithelial cells (mTECs) dominantly express a truncated Melan-A transcript, the product of misinitiation of transcription. Consequently, the protein product in mTECs lacks the immunodominant epitope spanning residues 26-35, thus precluding central tolerance to this antigen. In contrast, melanocytes and melanoma tumor cells express almost exclusively the full-length Melan-A transcript, thus providing the target antigen for efficient recognition by HLA-A2-restricted CD8(+) T cells. The frequency of these alternative gene transcription modes may be more common than previously appreciated and may represent an important factor modulating the efficiency of central tolerance induction in the thymus.
Resumo:
En el nostre projecte, considerem un escenari urbà o interurbà on persones amb dispositius mòbils (smartphones) o vehicles equipats amb interfícies de comunicació, estan interessats en compartir fitxers entre ells o descarregar-los al creuar Punts d’Accés (APs) propers a la carretera. Estudiem la possibilitat d’utilizar la cooperació en les trobades casuals entre nodes per augmentar la velocitat de descàrrega global. Amb aquest objectiu, plantejem algoritmes per a la selecció de quins paquets, per a quins destins i quins transportistes s’escullen en cada moment. Mitjançant extenses simulacions, mostrem com les cooperacions carry&forward dels nodes augmenten significativament la velocitat de descàrrega dels usuaris, i com aquest resultat es manté per a diversos patrons de mobilitat, col•locacions d'AP i càrregues de la xarxa. Per altra banda, aparells com els smartphones, on la targeta de WiFi està encesa contínuament, consumeixen l'energia de la bateria en poques hores. En molts escenaris, una targeta WiFi sempre activa és poc útil, perque sovint no hi ha necessitat de transmissió o recepció. Aquest fet es veu agreujat en les Delay Tolerant Networks (DTN), on els nodes intercanvien dades quan es creuen i en tenen l’oportunitat. Les tècniques de gestió de l’estalvi d’energia permeten extendre la duració de les bateries. El nostre projecte analitza els avantatges i inconvenients que apareixen quan els nodes apaguen períodicament la seva targeta wireless per a estalviar energia en escenaris DTN. Els nostres resultats mostren les condicions en que un node pot desconnectar la bateria sense afectar la probabilitat de contacte amb altres nodes, i les condicions en que aquesta disminueix. Per exemple, es demostra que la vida del node pot ser duplicada mantenint la probabilitat de contacte a 1. I que aquesta disminueix ràpidament en intentar augmentar més la vida útil.
Resumo:
OBJECTIVE: To compare three spin-echo sequences, transverse T1-weighted (T1WI), transverse fat-saturated (FS) T2-weighted (T2WI), and transverse gadolinium-enhanced (Gd) FS T1WI, for the visualisation of normal and abnormal finger A2 pulley with magnetic resonance (MR) imaging at 3 tesla (T). MATERIALS AND METHODS: Sixty-three fingers from 21 patients were consecutively investigated. Two musculoskeletal radiologists retrospectively compared all sequences to assess the visibility of normal and abnormal A2 pulleys and the presence of motion or ghost artefacts. RESULTS: Normal and abnormal A2 pulleys were visible in 94% (59/63) and 95% (60/63) on T1WI sequences, in 63% (40/63) and 60% (38/63) on FS T2WI sequences, and in 87% (55/63) and 73% (46/63) on Gd FS T1WI sequences when read by the first and second observer, respectively. Motion and ghost artefacts were higher on FS T2WI sequences. Seven among eight abnormal A2 pulleys were detected, and were best depicted with Gd FS T1WI sequences in 71% (5/7) and 86% (6/7) by the first and the second observer, respectively. CONCLUSION: In 3-T MRI, the comparison between transverse T1WI, FS T2WI, and Gd FS T1WI sequences shows that transverse T1WI allows excellent depiction of the A2 pulley, that FS T2WI suffers from a higher rate of motion and ghost artefacts, and transverse Gd FS T1WI is the best sequence for the depiction of abnormal A2 pulley.
Resumo:
This document is also available in the Publications Section of the DHSS website at:www.dhssni.gov.uk åÊ åÊ