998 resultados para minimization methods
Resumo:
Background Accurate automatic segmentation of the caudate nucleus in magnetic resonance images (MRI) of the brain is of great interest in the analysis of developmental disorders. Segmentation methods based on a single atlas or on multiple atlases have been shown to suitably localize caudate structure. However, the atlas prior information may not represent the structure of interest correctly. It may therefore be useful to introduce a more flexible technique for accurate segmentations. Method We present Cau-dateCut: a new fully-automatic method of segmenting the caudate nucleus in MRI. CaudateCut combines an atlas-based segmentation strategy with the Graph Cut energy-minimization framework. We adapt the Graph Cut model to make it suitable for segmenting small, low-contrast structures, such as the caudate nucleus, by defining new energy function data and boundary potentials. In particular, we exploit information concerning the intensity and geometry, and we add supervised energies based on contextual brain structures. Furthermore, we reinforce boundary detection using a new multi-scale edgeness measure. Results We apply the novel CaudateCut method to the segmentation of the caudate nucleus to a new set of 39 pediatric attention-deficit/hyperactivity disorder (ADHD) patients and 40 control children, as well as to a public database of 18 subjects. We evaluate the quality of the segmentation using several volumetric and voxel by voxel measures. Our results show improved performance in terms of segmentation compared to state-of-the-art approaches, obtaining a mean overlap of 80.75%. Moreover, we present a quantitative volumetric analysis of caudate abnormalities in pediatric ADHD, the results of which show strong correlation with expert manual analysis. Conclusion CaudateCut generates segmentation results that are comparable to gold-standard segmentations and which are reliable in the analysis of differentiating neuroanatomical abnormalities between healthy controls and pediatric ADHD.
Resumo:
La aplicabilidad, repetibilidad y capacidad de diferentes métodos de análisis para discriminar muestras de aceites con diferentes grados de oxidación fueron evaluadas mediante aceites recogidos en procesos de fritura en continuo en varias empresas españolas. El objetivo de este trabajo fue encontrar métodos complementarios a la determinación del índice de acidez para el control de calidad rutinario de los aceites de fritura empleados en estas empresas. La optimización de la determinación de la constante dieléctrica conllevó una clara mejora de la variabilidad. No obstante, excepto en el caso del índice del ATB, el resto de métodos ensayados mostraron una menor variabilidad. La determinación del índice del ATB fue descartada ya que su sensibilidad fue insuficiente para discriminar entre aceites con diferente grado de oxidación. Los diferentes parámetros de alteración determinados en los aceites de fritura mostraron correlaciones significativas entre el índice de acidez y varios parámetros de oxidación diferentes, como la constante dieléctrica, el índice de p-anisidina, la absorción al ultravioleta y el contenido en polímeros de los triacilgliceroles. El índice de acidez solo evalúa la alteración hidrolítica, por lo que estos parámetros aportan información complementaria al evaluar la alteración termooxidativa.
Resumo:
"Most quantitative empirical analyses are motivated by the desire to estimate the causal effect of an independent variable on a dependent variable. Although the randomized experiment is the most powerful design for this task, in most social science research done outside of psychology, experimental designs are infeasible. (Winship & Morgan, 1999, p. 659)." This quote from earlier work by Winship and Morgan, which was instrumental in setting the groundwork for their book, captures the essence of our review of Morgan and Winship's book: It is about causality in nonexperimental settings.
Resumo:
The centrifugal liquid membrane (CLM) cell has been utilized for chiroptical studies of liquid-liquid interfaces with a conventional circular dichroism (CD) spectropolarimeter. These studies required the characterization of optical properties of the rotating cylindrical CLM glass cell, which was used under the high speed rotation. In the present study, we have measured the circular and linear dichroism (CD and LD) spectra and the circular and linear birefringence (CB and LB) spectra of the CLM cell itself as well as those of porphyrine aggregates formed at the liquid-liquid interface in the CLM cell, applying Mueller matrix measurement method. From the results, it was confirmed that the CLM-CD spectra of the interfacial porphyrin aggregates observed by a conventional CD spectropolarimeter should be correct irrespective of LD and LB signals in the CLM cell.
Resumo:
With the use of supplementary cementing materials (SCMs) in concrete mixtures, salt scaling tests such as ASTM C672 have been found to be overly aggressive and do correlate well with field scaling performance. The reasons for this are thought to be because at high replacement levels, SCM mixtures can take longer to set and to develop their properties: neither of these factors is taken into account in the standard laboratory finishing and curing procedures. As a result, these variables were studied as well as a modified scaling test, based on the Quebec BNQ scaling test that had shown promise in other research. The experimental research focused on the evaluation of three scaling resistance tests, including the ASTM C672 test with normal curing as well as an accelerated curing regime used by VDOT for ASTM C1202 rapid chloride permeability tests and now included as an option in ASTM C1202. As well, several variations on the proposed draft ASTM WK9367 deicer scaling resistance test, based on the Quebec Ministry of Transportation BNQ test method, were evaluated for concretes containing varying amounts of slag cement. A total of 16 concrete mixtures were studied using both high alkali cement and low alkali cement, Grade 100 slag and Grade 120 slag with 0, 20, 35 and 50 percent slag replacement by mass of total cementing materials. Vinsol resin was used as the primary air entrainer and Micro Air® was used in two replicate mixes for comparison. Based on the results of this study, a draft alternative test method to ASTM C762 is proposed.
Resumo:
The method of instrumental variable (referred to as Mendelian randomization when the instrument is a genetic variant) has been initially developed to infer on a causal effect of a risk factor on some outcome of interest in a linear model. Adapting this method to nonlinear models, however, is known to be problematic. In this paper, we consider the simple case when the genetic instrument, the risk factor, and the outcome are all binary. We compare via simulations the usual two-stages estimate of a causal odds-ratio and its adjusted version with a recently proposed estimate in the context of a clinical trial with noncompliance. In contrast to the former two, we confirm that the latter is (under some conditions) a valid estimate of a causal odds-ratio defined in the subpopulation of compliers, and we propose its use in the context of Mendelian randomization. By analogy with a clinical trial with noncompliance, compliers are those individuals for whom the presence/absence of the risk factor X is determined by the presence/absence of the genetic variant Z (i.e., for whom we would observe X = Z whatever the alleles randomly received at conception). We also recall and illustrate the huge variability of instrumental variable estimates when the instrument is weak (i.e., with a low percentage of compliers, as is typically the case with genetic instruments for which this proportion is frequently smaller than 10%) where the inter-quartile range of our simulated estimates was up to 18 times higher compared to a conventional (e.g., intention-to-treat) approach. We thus conclude that the need to find stronger instruments is probably as important as the need to develop a methodology allowing to consistently estimate a causal odds-ratio.
Resumo:
The pursuit of high response rates to minimise the threat of nonresponse bias continues to dominate decisions about resource allocation in survey research. Yet a growing body of research has begun to question this practice. In this study, we use previously unavailable data from a new sampling frame based on population registers to assess the value of different methods designed to increase response rates on the European Social Survey in Switzerland. Using sampling data provides information about both respondents and nonrespondents, making it possible to examine how changes in response rates resulting from the use of different fieldwork methods relate to changes in the composition and representativeness of the responding sample. We compute an R-indicator to assess representativity with respect to the sampling register variables, and find little improvement in the sample composition as response rates increase. We then examine the impact of response rate increases on the risk of nonresponse bias based on Maximal Absolute Bias (MAB), and coefficients of variation between subgroup response rates, alongside the associated costs of different types of fieldwork effort. The results show that increases in response rate help to reduce MAB, while only small but important improvements to sample representativity are gained by varying the type of effort. These findings lend further support to research that has called into question the value of extensive investment in procedures aimed at reaching response rate targets and the need for more tailored fieldwork strategies aimed both at reducing survey costs and minimising the risk of bias.