986 resultados para microwave-assisted extraction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduced in 2008, the femtosecond laser is a promising new technological advance which plays an ever increasing role in cataract surgery where it automates the three main surgical steps: corneal incision, capsulotomy and lens fragmentation. The proven advantages over manual surgery are: a better quality of incision with reduced induced astigmatism; increased reliability and reproducibility of the capsulotomy with increased stability of the implanted lens; a reduction in the use of ultrasound. Regarding refractive results or safety, however, no prospective randomized study to date has shown significant superiority compared with standard manual technique. The significant extra cost generated by this laser, undertaken by the patient, is a limiting factor for both its use and study. This review outlines the potential benefits of femtosecond-laser-assisted cataract surgery due to the automation of key steps and the safety of this new technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper provides a simple theoretical framework to discuss the relationship between assisted reproductive technologies and the microeconomics of fertility choice. Individuals make choices of education and work along with decisions about whether and when to have children. Decisions regarding fertility are influenced by policy and labor market factors that affect the earnings opportunities of mothers and the costs of raising children. We show how observed differences in these economic factors across countries explain observed different fertility and childbearing age patterns. We then use the model to predict behavioral responses to biomedical improvements in assisted reproductive technologies, and hence the impact of these technologies on fertility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An ammonium chloride erythrocyte-lysing procedure was used to prepare a bacterial pellet from positive blood cultures for direct matrix-assisted laser desorption-ionization time of flight (MALDI-TOF) mass spectrometry analysis. Identification was obtained for 78.7% of the pellets tested. Moreover, 99% of the MALDI-TOF identifications were congruent at the species level when considering valid scores. This fast and accurate method is promising.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Freehand positioning of the femoral drill guide is difficult during hip resurfacing and the surgeon is often unsure of the implant position achieved peroperatively. The purpose of this study was to find out whether, by using a navigation system, acetabular and femoral component positioning could be made easier and more precise. Eighteen patients operated on by the same surgeon were matched by sex, age, BMI, diagnosis and ASA score (nine patients with computer assistance, nine with the regular ancillary). Pre-operative planning was done on standard AP and axial radiographs with CT scan views for the computer-assisted operations. The final position of implants was evaluated by the same radiographs for all patients. The follow-up was at least 1 year. No difference between both groups in terms of femoral component position was observed (p > 0.05). There was also no difference in femoral notching. A trend for a better cup position was observed for the navigated hips, especially for cup anteversion. There was no additional operating time for the navigated hips. Hip navigation for resurfacing surgery may allow improved visualisation and hip implant positioning, but its advantage probably will be more obvious with mini-incisions than with regular incision surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: In order to improve safety of pedicle screw placement several techniques have been developed. More recently robotically assisted pedicle insertion has been introduced aiming at increasing accuracy. The aim of this study was to compare this new technique with the two main pedicle insertion techniques in our unit namely fluoroscopically assisted vs EMG aided insertion. Material and methods: A total of 382 screws (78 thoracic,304 lumbar) were introduced in 64 patients (m/f = 1.37, equally distributed between insertion technique groups) by a single experienced spinal surgeon. From those, 64 (10 thoracic, 54 lumbar) were introduced in 11 patients using a miniature robotic device based on pre operative CT images under fluoroscopic control. 142 (4 thoracic, 138 lumbar) screws were introduced using lateral fluoroscopy in 27 patients while 176 (64 thoracic, 112 lumbar) screws in 26 patients were inserted using both fluoroscopy and EMG monitoring. There was no difference in the distribution of scoliotic spines between the 3 groups (n = 13). Screw position was assessed by an independent observer on CTs in axial, sagittal and coronal planes using the Rampersaud A to D classification. Data of lumbar and thoracic screws were processed separately as well as data obtained from axial, sagittal and coronal CT planes. Results: Intra- and interobserver reliability of the Rampersaud classification was moderate, (0.35 and 0.45 respectively) being the least good on axial plane. The total number of misplaced screws (C&D grades) was generally low (12 thoracic and 12 lumbar screws). Misplacement rates were same in straight and scoliotic spines. The only difference in misplacement rates was observed on axial and coronal images in the EMG assisted thoracic screw group with a higher proportion of C or D grades (p <0.05) in that group. Recorded compound muscle action potentials (CMAP) values of the inserted screws were 30.4 mA for the robot and 24.9mA for the freehand technique with a CI of 3.8 of the mean difference of 5.5 mA. Discussion: Robotic placement did improve the placement of thoracic screws but not that of lumbar screws possibly because our misplacement rates in general near that of published navigation series. Robotically assisted spine surgery might therefore enhance the safety of screw placement in particular in training settings were different users at various stages of their learning curve are involved in pedicle instrumentation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Images obtained from high-throughput mass spectrometry (MS) contain information that remains hidden when looking at a single spectrum at a time. Image processing of liquid chromatography-MS datasets can be extremely useful for quality control, experimental monitoring and knowledge extraction. The importance of imaging in differential analysis of proteomic experiments has already been established through two-dimensional gels and can now be foreseen with MS images. We present MSight, a new software designed to construct and manipulate MS images, as well as to facilitate their analysis and comparison.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acetabular cup orientation is a key factor determining hip stability, and standard mechanical guides have shown little help in improving alignment. An in vitro study was carried out to compare the accuracy and precision of a new gravity-assisted guidance system with a standard mechanical guide. Three hundred ten cups were impacted by 5 surgeons, and the final cup orientation was measured. With the new guide, the average error in anteversion was 0.4 degrees , compared with 10.4 degrees with the standard guide and 0.3 degrees and -4.7 degrees , respectively, for abduction angles. The average time required for orienting the cups was similar for both guides. The accuracy and reproducibility obtained with the new guide were better (P < .0001). These good results would require a clinical validation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to evaluate the effect of chaotropic agents on proteoglycan and non-collagenous proteins, chicken xiphoid cartilage was treated with guanidine-HCI and MgCl2 in different concentrations (1M to 5M), and different periods of time (12, 24, 48 and 72hr). The maximum yield of uronic acid was obtained with 3M MgCl2 (73.3 per cent). Concentrations of 4M and 5M of MgCl2 showed that much less uronic acid was removed, 55.3 per cent and 38.1 respectively. Extraction with 3M MgCl2 and 3M guanidine-HCl resulted better efficiency when performed for 48 hr. Analysis by SDS-PAGE of the extracts obtained with guanidine-HCl and MgCl, in different concentrations pointed out that most components are equally removed with the two solvents, showing that the extraction with MgCl2 is an alternative assay to remove non-collagenous proteins from extracellular matrix.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the outbreak of an epidemic neuropathy (EN) of unknown ethiology, a study of the prevalence and factors associated to the disease was carried out in the Zamora community, municipality of Marianao, Havana City. There were 11 patients identified with EN for a prevalence rate of 1.7/100. The major risk group was the one between 45 and 64 years of age, female sex, black skin. In the univaried analysis, a high prevalence ratio (PR) was found linked to beverage intake (PR=5.32 95%; confidence intervals (CI) = 1.2-24.4), frequent drugs intake (PR=6.59; CI=1.8-24.6), consumption of edible of non certified fats (PR=4.48; CI=1.2-16.7) and the smoking habit (PR=3.6; CI=1.1-12.2). More than73/100 (CI= 68.7-78.3) of the people under serologic study were infected with Coxsakie virus A-9 (strain 47) isolated from a patient still under research. It seems there are many factors like linder intake, antecedents of hemorrhagic conjuntivitis, nutritional aspects and others that, with the virus isolated were associated with this epidemiologic situation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapport de Synthèse : Un sevrage lent comme méthode élective pour l'interruption de la méthadone est coûteux en termes de temps, le plus souvent associé à un taux élevé d'abandon. Bien que les méthodes ultrarapides de désintoxication des opiacés aient gagné en popularité récemment, elles sont chères et posent les problèmes spécifiques liés aux patients traités par la méthadone. Méthodologie: ont été inclus dans l'étude dix patients en traitement de substitution avec de la méthadone. La dernière dose de méthadone a été administrée le matin même du jour de l'admission, en préalable à l'hospitalisation. Les médicaments suivants ont été administrés le jour suivant l'admission: ondansetron 36mg, ranitidine 40mg, loperamide 8m., clonazepam 4m., promazine 1OOmg, metoclopramide 70mg, naltrexone 5Omg. L'échelle objective de sevrage des opiacés (Objective Opiate Withdrawal Scale) a été appliquée au deuxième, troisième et quatrième jour d'hospitalisation, deux fois par jour, à 8h00 et 18h00. Un suivi a été réalisé sous la forme d'entretiens téléphoniques pendant une semaine, respectivement six mois après la date de sortie de l'hôpital, faisant suite à la désintoxication. Un autre entretient téléphonique a été réalisé dans les six mois suivant le "post-sevrage", avec pour objectif d'investiguer la continuité du traitément, une éventuelle rechute dans l'abus de drogues et une possible réintroduction de la méthadone. Résultats: nous avons pu déterminer quatre groupes de symptômes, sur la base d'une observation de trois jours d'évolution: 1) Les signes typiques du syndrome de sevrage de retrait des opiacés, symptôme de froid et chaud, pilo-érection, anxiété caractérisée par une intensité initiale élevée et une disparition relativement continue. 2) Hyperactivité neurovégétative caractérisée par une intensité initiale élevée et une rapide disparition. 3) Phénomènes neurovégétatifs dont l'intensité s'est maintenue durant toute la période d'observation. 4) Contractions musculaires, insomnies et anorexie, manque d'appétit, réapparaissant chez certains patients au 2ème et au début du 3ème jour. Conclusions: une procédure courte de désintoxication utilisant une dose unique de naltrexone s'avère être une méthode alternative valable pour un sevrage de la méthadone. Cette méthode semble accélérer et écourter la symptomatologie associée au sevrage. Le cours des symptômes peut être interprété comme biphasique. Une première phase de retrait est éminemment caractérisée par tous les symptômes typiques eux-mêmes et probablement induits par la naltrexone. La seconde phase, pour un plus petit nombre de patients, peut être interprétée comme en corrélation avec une concentration de méthadone en diminution significative ultérieurement.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estimating the time since the last discharge of firearms and/or spent cartridges may be a useful piece of information in forensic firearm-related cases. The current approach consists of studying the diffusion of selected volatile organic compounds (such as naphthalene) released during the shooting using solid phase micro-extraction (SPME). However, this technique works poorly on handgun car-tridges because the extracted quantities quickly fall below the limit of detection. In order to find more effective solutions and further investigate the aging of organic gunshot residue after the discharge of handgun cartridges, an extensive study was carried out in this work using a novel approach based on high capacity headspace sorptive extraction (HSSE). By adopting this technique, for the first time 51 gunshot residue (GSR) volatile organic compounds could be simultaneously detected from fired handgun cartridge cases. Application to aged specimens showed that many of those compounds presented significant and complementary aging profiles. Compound-to-compound ratios were also tested and proved to be beneficial both in reducing the variability of the aging curves and in enlarging the time window useful in a forensic casework perspective. The obtained results were thus particularly promising for the development of a new complete forensic dating methodology.