844 resultados para metrological reliability
Resumo:
My study investigated internal consistency estimates of psychometric surveys as an operationalization of the state of measurement precision of constructs in industrial and organizational (I/O) psychology. Analyses were conducted of samples used in research articles published in the Journal of Applied Psychology between 1975 and 2010 in five year intervals (K = 934) from 480 articles yielding 1427 coefficients. Articles and their respective samples were coded for test-taker characteristics (e.g., age, gender, and ethnicity), research settings (e.g., lab and field studies), and actual tests (e.g., number of items and scale anchor points). A reliability and inter-item correlations depository was developed for I/O variables and construct groups. Personality measures had significantly lower inter-item correlations than other construct groups. Also, internal consistency estimates and reporting practices were evaluated over time, demonstrating an improvement in measurement precision and missing data.
Resumo:
The emergence of microgeneration has recently lead to the concept of microgrid, a network of LV consumers and producers able to export electric energy in some circumstances and also to work in an isolated way in emergency situations. Research on the organization of microgrids, control devices, functionalities and other technical aspects is presently being carried out, in order to establish a consistent technical framework to support the concept. The successful development of the microgrid concept implies the definition of a suitable regulation for its integration on distribution systems. In order to define such a regulation, the identification of costs and benefits that microgrids may bring is a crucial task. Actually, this is the basis for a discussion about the way global costs could be divided among the different agents that benefit from the development of microgrids. Among other aspects, the effect of microgrids on the reliability of the distribution network has been pointed out as an important advantage, due to the ability of isolated operation in emergency situations. This paper identifies the situations where the existence of a microgrid may reduce the interruption rate and duration and thus improve the reliability indices of the distribution network. The relevant expressions necessary to quantify the reliability are presented. An illustrative example is included, where the global influence of the microgrid in the reliability is commented.
Resumo:
Predicting risk of adverse healthcare outcomes is important to enable targeted delivery of interventions. The Risk Instrument for Screening in the Community (RISC), designed for use by public health nurses (PHNs), measures the one-year risk of hospitalisation, institutionalisation and death in community-dwelling older adults according to a five-point global risk score: from low (score 1,2), medium (3) and high (4,5). We examined the inter-rater reliability (IRR) of the RISC between student PHNs (n=32) and expert raters using six cases (two low, medium and high-risk), scored before and after RISC training. Correlations increased for each adverse outcome, statistically significantly for institutionalisation (r=0.72 to 0.80,p=0.04) and hospitalisation, (r=0.51 to 0.71,p<0.01) but not death. Training improved accuracy for low-risk but not all high-risk cases. Overall, the RISC showed good IRR, which increased after RISC training. That reliability reduced for some high-risk cases suggests that the training programme requires adjustment to further improve IRR.
Resumo:
Background: Food allergy (FA) is a heavy burden for patients and their families and can significantly reduce the quality of life (QoL) of both. To provide adequate support, qualitative and quantitative evaluation of the parents' QoL may be helpful. The objective of this study is to develop and validate a Japanese version of the Food Allergy QoL QuestionnaireeParent Form (FAQLQ-PF-J), an internationally validated disease-specific QoL measurement of the parental burden of having a child with FA. Methods: The FAQLQ-PF and the Food Allergy Independent Measure (FAIM), an instrument to test the construct validity of the FAQLQ-PF-J, were translated into Japanese. After language validation, the questionnaires were administered to parents of FA children aged 0e12 years and those of age-matched healthy (without FA) children. Internal consistency (by Cronbach's a) and test-retest reliability were evaluated. Construct validity and discriminant validity were also examined. Results: One hundred twenty-seven parents of children with FA and 48 parents of healthy children filled out the questionnaire. The FAQLQ-PF-J showed excellent internal consistency (Cronbach's a > 0.77) and test-retest reliability. Good construct validity was demonstrated by significant correlations between the FAQLQ-PF-J and FAIM-J scores. It discriminated parents of children with FA from those without. The scores were significantly higher (lower QoL) for parents of FA children with a history of anaphylaxis than those without, for those with >6 FA-related symptoms experienced than those with less FA-related symptoms. Conclusions: The FAQLQ-PF-J is a reliable and valid measure of the parental burden of FA in children.
Resumo:
The International FItness Scale (IFIS) is a self-reported measure of physical fitness that could easily. This scale has been validated in children, adolescents, and young adults; however, it is unknown whether the IFIS represents a valid and reliable estimate of physical fitness in Latino-American youth population. In the present study we aimed to examine the validity and reliability of the IFIS on a population-based sample of schoolchildren in Bogota, Colombia. Participants were 1,875 Colombian youth (56.2% girls) aged 9 to 17.9 years old. We measured adiposity markers (body fat, waist-to-height ratio, skinfold thicknesses and BMI), blood pressure, lipids profile, fasting glucose, and physical fitness level (self reported and measured). Also, a validated cardiometabolic risk index was used. An age- and sex-matched sample of 229 Schoolchildren originally not included in the study sample fulfilled IFIS twice for reliability purposes. Our data suggest that both measured and self-reported overall fitness were associated inversely with adiposity indicators and a cardiometabolic risk score. Overall, schoolchildren who self-reported “good” and “very good” fitness had better measured fitness than those who reported “very poor” and “poor” fitness (all p<0.001). Test–retest reliability of IFIS items was also good, with an average weighted Kappa of 0.811. Therefore, our findings suggest that self-reported fitness, as assessed by IFIS, is a valid, reliable, and health-related measure, and it can be a good alternative for future use in large studies with Latin-schoolchildren from Colombia.
Resumo:
The aim of the present study was to examine the reliability of tethered swimming in the evaluation of age group swimmers. The sample was composed of 8 male national level swimmers with at least 4 years of experience in competitive swimming. Each swimmer performed two 30 second maximal intensity tethered swimming tests, on separate days. Individual force-time curves were registered to assess maximum force, mean force and the mean impulse of force. Both consistency and reliability were very strong, with Cronbach’s Alpha values ranging from 0.970 to 0.995. All the applied metrics presented a very high agreement between tests, with the mean impulse of force presenting the highest. These results indicate that tethered swimming can be used to evaluate age group swimmers. Furthermore, better comprehension of the swimmers ability to effectively exert force in the water can be obtained using the impulse of force. Key words: swimming, training and testing, propulsive force, front crawl.
Resumo:
Molecular radiotherapy (MRT) is a fast developing and promising treatment for metastasised neuroendocrine tumours. Efficacy of MRT is based on the capability to selectively "deliver" radiation to tumour cells, minimizing administered dose to normal tissues. Outcome of MRT depends on the individual patient characteristics. For that reason, personalized treatment planning is important to improve outcomes of therapy. Dosimetry plays a key role in this setting, as it is the main physical quantity related to radiation effects on cells. Dosimetry in MRT consists in a complex series of procedures ranging from imaging quantification to dose calculation. This doctoral thesis focused on several aspects concerning the clinical implementation of absorbed dose calculations in MRT. Accuracy of SPECT/CT quantification was assessed in order to determine the optimal reconstruction parameters. A model of PVE correction was developed in order to improve the activity quantification in small volume, such us lesions in clinical patterns. Advanced dosimetric methods were compared with the aim of defining the most accurate modality, applicable in clinical routine. Also, for the first time on a large number of clinical cases, the overall uncertainty of tumour dose calculation was assessed. As part of the MRTDosimetry project, protocols for calibration of SPECT/CT systems and implementation of dosimetry were drawn up in order to provide standard guidelines to the clinics offering MRT. To estimate the risk of experiencing radio-toxicity side effects and the chance of inducing damage on neoplastic cells is crucial for patient selection and treatment planning. In this thesis, the NTCP and TCP models were derived based on clinical data as help to clinicians to decide the pharmaceutical dosage in relation to the therapy control and the limitation of damage to healthy tissues. Moreover, a model for tumour response prediction based on Machine Learning analysis was developed.
Resumo:
This thesis studies the state-of-the-art of phasor measurement units (PMUs) as well as their metrological requirements stated in the IEEE C37.118.1 and C37.118.2 Standards for guaranteeing correct measurement performances. Communication systems among PMUs and their possible applicability in the field of power quality (PQ) assessment are also investigated. This preliminary study is followed by an analysis of the working principle of real-time (RT) simulators and the importance of hardware-in-the-loop (HIL) implementation, examining the possible case studies specific for PMUs, including compliance tests which are one of the most important parts. The core of the thesis is focused on the implementation of a PMU model in the IEEE 5-bus network in Simulink and in the validation of the results using OPAL RT-4510 as a real-time simulator. An initial check allows one to get an idea about the goodness of the results in Simulink, comparing the PMU data with respect to the load-flow steady-state information. In this part, accuracy indices are also calculated for both voltage and current synchrophasors. The following part consists in the implementation of the same code in OPAL-RT 4510 simulator, after which an initial analysis is carried out in a qualitative way in order to get a sense of the goodness of the outcomes. Finally, the confirmation of the results is based on an examination of the attained voltage and current synchrophasors and accuracy indices coming from Simulink models and from OPAL system, using a Matlab script. This work also proposes suggestions for an upcoming operation of PMUs in a more complex system as the Digital Twin (DT) in order to improve the performances of the already-existing protection devices of the distribution system operator (DSO) for a future enhancement of power systems reliability.
Resumo:
The Smart Grid needs a large amount of information to be operated and day by day new information is required to improve the operation performance. It is also fundamental that the available information is reliable and accurate. Therefore, the role of metrology is crucial, especially if applied to the distribution grid monitoring and the electrical assets diagnostics. This dissertation aims at better understanding the sensors and the instrumentation employed by the power system operators in the above-mentioned applications and studying new solutions. Concerning the research on the measurement applied to the electrical asset diagnostics: an innovative drone-based measurement system is proposed for monitoring medium voltage surge arresters. This system is described, and its metrological characterization is presented. On the other hand, the research regarding the measurements applied to the grid monitoring consists of three parts. The first part concerns the metrological characterization of the electronic energy meters’ operation under off-nominal power conditions. Original test procedures have been designed for both frequency and harmonic distortion as influence quantities, aiming at defining realistic scenarios. The second part deals with medium voltage inductive current transformers. An in-depth investigation on their accuracy behavior in presence of harmonic distortion is carried out by applying realistic current waveforms. The accuracy has been evaluated by means of the composite error index and its approximated version. Based on the same test setup, a closed-form expression for the measured current total harmonic distortion uncertainty estimation has been experimentally validated. The metrological characterization of a virtual phasor measurement unit is the subject of the third and last part: first, a calibrator has been designed and the uncertainty associated with its steady-state reference phasor has been evaluated; then this calibrator acted as a reference, and it has been used to characterize the phasor measurement unit implemented within a real-time simulator.
Resumo:
The work carried out in this thesis aims at: - studying – in both simulative and experimental methods – the effect of electrical transients (i.e., Voltage Polarity Reversals VPRs, Temporary OverVoltages TOVs, and Superimposed Switching Impulses SSIs) on the aging phenomena in HVDC extruded cable insulations. Dielectric spectroscopy, conductivity measurements, Fourier Transform Infra-Red FTIR spectroscopy, and space charge measurements show variation in the insulating properties of the aged Cross-Linked Polyethylene XLPE specimens compared to non-aged ones. Scission in XLPE bonds and formation of aging chemical bonds is also noticed in aged insulations due to possible oxidation reactions. The aged materials show more ability to accumulate space charges compared to non-aged ones. An increase in both DC electrical conductivity and imaginary permittivity has been also noticed. - The development of life-based geometric design of HVDC cables in a detailed parametric analysis of all parameters that affect the design. Furthermore, the effect of both electrical and thermal transients on the design is also investigated. - The intrinsic thermal instability in HVDC cables and the effect of insulation characteristics on the thermal stability using a temperature and field iterative loop (using numerical methods – Finite Difference Method FDM). The dielectric loss coefficient is also calculated for DC cables and found to be less than that in AC cables. This emphasizes that the intrinsic thermal instability is critical in HVDC cables. - Fitting electrical conductivity models to the experimental measurements using both models found in the literature and modified models to find the best fit by considering the synergistic effect between field and temperature coefficients of electrical conductivity.
Resumo:
In the last years the increasing demand of higher torque and power densities has led to the adoption of hairpin windings (HWs) in electrical machines, mainly in those intended for automotive applications. However, this winding topology is quite sensitive to AC losses, hence one of their main challenges is represented by their reduction. This work deals with different design aspects related to the enhancements of some performance figures of rotating electrical machines for traction applications, above all power density and reliability, mainly through the adoption of HWs.
Resumo:
The ambitious goals of increasing the efficiency, performance and power densities of transportation drives cannot be met with compromises in the motor reliability. For the insulation specialists the challenge will be critical as the use of wide-bandgap converters (WBG, based on SiC and GaN switches) and the higher operating voltages expected for the next generation drives will enhance the electrical stresses to unprecedented levels. It is expected for the DC bus in aircrafts to reach 800 V (split +/-400 V) and beyond, driven by the urban air mobility sector and the need for electrification of electro-mechanical/electro-hydraulic actuators (an essential part of the "More Electric Aircraft" concept). Simultaneously the DC bus in electric vehicles (EV) traction motors is anticipated to increase up to 1200 V very soon. The electrical insulation system is one of the most delicate part of the machine in terms of failure probability. In particular, the appearance of partial discharges (PD) is disruptive on the reliability of the drive, especially under fast repetitive transients. Extensive experimental activity has been performed to extend the body of knowledge on PD inception, endurance under PD activity, and explore and identify new phenomena undermining the reliability. The focus has been concentrated on the impact of the WGB-converter produced waveforms and the environmental conditions typical of the aeronautical sector on insulation models. Particular effort was put in the analysis at the reduced pressures typical of aircraft cruise altitude operation. The results obtained, after a critical discussion, have been used to suggest a coordination between the insulation PD inception voltage with the converter stresses and to propose an improved qualification procedure based on the existing IEC 60034-18-41 standard.
Resumo:
The world is quickly changing, and the field of power electronics assumes a pivotal role in addressing the challenges posed by climate change, global warming, and energy management. The introduction of wide-bandgap semiconductors, particularly gallium nitride (GaN), in contrast to the traditional silicon technology, is leading to lightweight, compact and evermore efficient circuitry. However, GaN technology is not mature yet and still presents reliability issues which constrain its widespread adoption. Therefore, GaN reliability is a hotspot for the research community. Extensive efforts have been directed toward understanding the physical mechanisms underlying the performance and reliability of GaN power devices. The goal of this thesis is to propose a novel in-circuit degradation analysis in order to evaluate the long-term reliability of GaN-based power devices accurately. The in-circuit setup is based on measure-stress-measure methodology where a high-speed synchronous buck converter ensures the stress while the measure is performed by means of full I-V characterizations. The switch from stress mode to characterization mode and vice versa is automatic thanks to electromechanical and solid-state relays controlled by external unit control. Because these relays are located in critical paths of the converter layout, the design has required a comprehensive study of electrical and thermal problems originated by the use of GaN technology. In addition, during the validation phase of the converter, electromagnetic-lumped-element circuit simulations are carried out to monitor the signal integrity and junction temperature of the devices under test. However, the core of this work is the in-circuit reliability analysis conducted with 80 V GaN HEMTs under several operating conditions of the converter in order to figure out the main stressors which contribute to the device's degradation.
Resumo:
The objectives of this study were to develop a questionnaire that evaluates the perception of nursing workers to job factors that may contribute to musculoskeletal symptoms, and to evaluate its psychometric properties. Internationally recommended methodology was followed: construction of domains, items and the instrument as a whole, content validity, and pre-test. Psychometric properties were evaluated among 370 nursing workers. Construct validity was analyzed by the factorial analysis, known-groups technique, and convergent validity. Reliability was assessed through internal consistency and stability. Results indicated satisfactory fit indices during confirmatory factor analysis, significant difference (p < 0.01) between the responses of nursing and office workers, and moderate correlations between the new questionnaire and Numeric Pain Scale, SF-36 and WRFQ. Cronbach's alpha was close to 0.90 and ICC values ranged from 0.64 to 0.76. Therefore, results indicated that the new questionnaire had good psychometric properties for use in studies involving nursing workers.