899 resultados para high performance liquid chromatography with diode array detection
Resumo:
This paper describes the use of a dental amalgam electrode (DAE) to evaluate the electrochemical behaviour and to develop an electroanalytical procedure for determination of diquat herbicide in natural water and potato samples. The work was based on the square wave voltammetry responses of diquat, which presented two well-defined and reversible reduction peaks, at -0.56 V (peak 1) and -1.00V (peak 2). The experimental and voltammetric parameters were optimised, and the analytical curves were constructed and compared to similar curves performed by high performance liquid chromatography coupled to ultraviolet-visible spectrophotometric detector (HPLC/UV-vis). The responses were directly proportional to diquat concentration in a large interval of concentration, and the calculated detection limits were very similar, around 10 mu g L(-1) (10 ppb) for voltammetric and chromatographic experiments. These values were lower than the maximum residue limit established for natural water by the Brazilian Environmental Agency. The recovery percentages in pure electrolyte, natural water and potato samples showed values from 70% to 130%, demonstrating that the voltammetric methodology proposed is suitable for determining any contamination by diquat in different samples, minimising the toxic residues due to the use of liquid mercury or the adsorptive process relative to use of other solid surfaces. (C) 2009 Published by Elsevier B.V.
Resumo:
A simple and highly selective electrochemical method was developed for the single or simultaneous determination of paracetamol (N-acetyl-p-aminophenol, acetaminophen) and caffeine (3,7-dihydro-1,3,7-trimethyl-1H-purine-2,6-dione) in aqueous media (acetate buffer, pH 4.5) on a boron-doped diamond (BDD) electrode using square wave voltammetry (SWV) or differential Pulse voltammetry (DPV). Using DPV with the cathodically pre-treated BDD electrode, a separation of about 550 mV between the peak oxidation potentials Of paracetamol and caffeine present in binary mixtures was obtained. The calibration curves for the simultaneous determination of paracetamol and caffeine showed an excellent linear response, ranging from 5.0 x 10(-7) mol L(-1) to 8.3 x 10(-7) mol L(-1) for both compounds. The detection limits for the simultaneous determination of paracetamol and caffeine were 4.9 x 10(-7) mol L-1 and 3.5 x 10(-8) mol L(-1), respectively. The proposed method Was Successfully applied in the simultaneous determination of paracetamol and caffeine in several pharmaceutical formulations (tablets), with results similar to those obtained using a high-performance liquid chromatography method (at 95% confidence level). (C) 2008 Elsevier BY. All rights reserved.
Resumo:
Tuberculosis is a serious disease, but curable in practically 100% of new cases, since complied the principles of modern chemotherapy. Isoniazid (ISN), Rifampicin (RIF), Pyrazinamide (PYR) and Chloride Ethambutol (ETA) are considered first line drugs in the treatment of tuberculosis, by combining the highest level of efficiency with acceptable degree of toxicity. Concerning USP 33 - NF28 (2010) the chromatography analysis to 3 of 4 drugs (ISN, PYR and RIF) last in average 15 minutes and 10 minutes more to obtain the 4th drug (ETA) using a column and mobile phase mixture different, becoming its industrial application unfavorable. Thus, many studies have being carried out to minimize this problem. An alternative would use the UFLC, which is based with the same principles of HPLC, however it uses stationary phases with particles smaller than 2 μm. Therefore, this study goals to develop and validate new analytical methods to determine simultaneously the drugs by HPLC/DAD and UFLC/DAD. For this, a analytical screening was carried out, which verified that is necessary a gradient of mobile phase system A (acetate buffer:methanol 94:6 v/v) and B (acetate buffer:acetonitrile 55:45 v/v). Furthermore, to the development and optimization of the method in HPLC and UFLC, with achievement of the values of system suitability into the criteria limits required for both techniques, the validations have began. Standard solutions and tablets test solutions were prepared and injected into HPLC and UFLC, containing 0.008 mg/mL ISN, 0.043 mg/mL PYR, 0.030 mg.mL-1 ETA and 0.016 mg/mL RIF. The validation of analytical methods for HPLC and UFLC was carried out with the determination of specificity/selectivity, analytical curve, linearity, precision, limits of detection and quantification, accuracy and robustness. The methods were adequate for determination of 4 drugs separately without interfered with the others. Precise, due to the fact of the methods demonstrated since with the days variation, besides the repeatability, the values were into the level required by the regular agency. Linear (R> 0,99), once the methods were capable to demonstrate results directly proportional to the concentration of the analyte sample, within of specified range. Accurate, once the methods were capable to present values of variation coefficient and recovery percentage into the required limits (98 to 102%). The methods showed LOD and LOQ very low showing the high sensitivity of the methods for the four drugs. The robustness of the methods were evaluate, facing the temperature and flow changes, where they showed robustness just with the preview conditions established of temperature and flow, abrupt changes may influence with the results of methods
Resumo:
The effect of four extracts from neem seeds (Azadirachta indica) containing 2000, 5000, 9000 and 10,000 ppm of azadirachtin A (AZA), quantified by high-performance liquid chromatography (HPLC) and diluted to 1.25%; 2.5%; 5.0%; 10.0% and 12.8% was verified by in vitro tests with engorged females and larvae of the cattle tick Rhipicephalus micro plus. The results from the bioassays with the engorged females showed that the main toxic effect of the extracts was reduction of the reproductive parameters, with a sharp drop in the number of eggs laid and the hatching rate, mainly when the extracts were diluted to 10.0% and 12.8%. The product effectiveness (PE) calculations for all the solutions tested showed that the AZA solution at 10,000 ppm (N10) was the most effective. However, statistical analysis of the PE data obtained for the proportional AZA concentrations in the different diluted extracts showed significance (P<0.05) of the effects included in the model (extract dilution, principle effect (classificatory) of the assay (extract) and the interaction between the two), indicating significant variations due to the dilution, the test and the interaction between the two factors in the tests with engorged females. For solutions N2, N5, and N9, it was not possible to estimate LC(90) values in the dilution range tested. The lowest LC(50) was observed for extract N5, and although extract N10 was the only extract for which the LC(90) could be estimated within the range tested, the LC(50) was higher than for N5 and N9. These results suggest that substances other than AZA present in the extracts influenced the efficacy, especially up to a certain LC range. In the tests with larvae, no mortality was observed, indicating zero effectiveness of all the extracts tested. The results of the tests with engorged females showed that the neem extracts had acaricide activity, inhibiting egg laying and the larval hatching rate. Complementary studies are necessary to develop new methods to isolate and/or identify other substances besides AZA contained in this plant, to enable using products made from it as acaricides. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
A simple and rapid method was developed for the determination of amfepramone hydrochloride, fenprorex, and diazepam in capsules using high performance liquid chromatography (HPLC) with UV detection. This procedure provided conditions for the separation of the active ingredient from the complex matrices of the dosage forms by extraction in methanol. Isocratic reversed phase chromatography was performed using acetonitrile, methanol, and aqueous 0,1% ammonium carbonate (50:10:40) as a mobile phase, LiChrospher 100 RP 18 column (125 x 5 mm id, 5 mu m), a column temperature of 25 +/- 1 degrees C and detection at 230 nm.The calibration curves were linear over a wide concentration range (20-2000 mu g.mL(-1) to amfepramone hydrochloride, 8-800 mu g.mL(-1) to fenproporex, and 4-200 mu g.mL(-1) to diazepam) and good analytical recovery (87.1 to 107.8%) was obtained. The method is accurate and precise, as well as having advantages such as simplicity and short duration of analysis. Twenty samples of pharmaceutical preparations labelled as natural products were analysed. Anorectics and diazepam, were detected in 40% of the samples.
Resumo:
Propolis obtained from honeybee hives has been widely used in medicine, cosmetics, and industry due to its versatile biological activities (antioxidant, antimicrobial, fungicidal, antiviral, antiulcer, immunostimulating, and cytostatic). These activities are mainly attributed to the presence of flavonoids in propolis, which points out the interest in quantifying these constituents in propolis preparations, as well as validation of analytical methodologies. High-performance liquid chromatography (HPLC) methods have been reported to quantify isolated flavonoids or these compounds in complex biological matrices, such as herbal raw materials and extractive preparations. An efficient, precise, and reliable method was developed for quantification of propolis extractive solution using HPLC with UV detection. The chromatograms were obtained from various gradient elution systems (GES) tested in order to establish the ideal conditions for the analysis of propolis extractive solution, using methanol and water: acetonitrile (97.5 : 2.5, v/v) as mobile phase. Gradient reversed phase chromatography was performed using a stainless steel column (250 x 4.6 mm i.d., 5 mum) filled with Chromsep RP 18 (Varian), column temperature at 30.0 +/- 0.1degreesC and detection at 310 nm. The main validation parameters of the method were also determined. The method showed linearity for chrysin in the range 0.24-2.4 mug mL(-1) with good correlation coefficients (0.9975). Precision and accuracy were determined. The obtained results demonstrate the efficiency of the proposed method. The analytical procedure is reliable and offers advantages in terms of speed and cost of reagents.
Resumo:
A sensitive, accurate, reliable and easy method was developed for the quantification of oxamniquine in capsules using high-performance liquid chromatography (HPLC) with UV detection. This technique provided conditions for the separation of the active ingredient from the dosage form by extraction in methanol. Isocratic reversed phase chromatography was performed using methanol, water, and triethanolamine (60:40:0.099, v/v/w) (System C) or methanol, acetonitrile, water and formic acid (40:30:30:0.083, v/v/w) (System D) as mobile phase, a stainless steel column (125 x 4 mm i.d., 5 mum) filled with LiChrospher 100 RP-18 (Merck), column temperature of 28 +/- 2 degreesC and detection at 260 nm. The calibration curves were linear over a wide concentration range (1.0-20.0 mug ml(-1) of oxamniquine) to the Systems C and D with good correlation factor (0.9990 and 0.9982, respectively). The average content obtained were 100.1 +/- 1.5% (System C) and 102.4 +/- 0.8% (System D). The presence of lactose, starch, magnesium stearate and sodium laurylsulphate did not interfere in the results of the analysis. The above findings showed the proposed method to be both simple and added advantage of allowing for fast analysis. (C) 2001 Elsevier B.V. B.V. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The pharmacokinetics of enrofloxacin (ENRO), a fluoroquinolone antimicrobial agent, was studied in male broiler chickens (Cobb) after single oral administration of 10 mg of ENRO/kg b.w. A high-performance liquid chromatography-photodiode array detector (DAD) (HPLC-DAD) method was developed and validated and used for quantitation of ENRO and its major metabolite ciprofloxacin in plasma. The HPLC analyses were carried out using a cationic-octadecyl mixed column and 0.05 mol/L phosphate buffer (pH 2.5)/acetonitrile as mobile phase. The sample preparation of plasma consisted of the precipitation of proteins followed by solid phase extraction on cationic-octadecyl mixed cartridges. The method was validated considering linear range, linearity, selectivity, sensitivity, limit of detection (LOD), limit of quantitation (LOQ), intra- and inter-day precisions and accuracy. The LOD and LOQ for both fluoroquinolones were 60 and 200 ng/mL for plasma. The plasma concentration vs. time graph was characteristic of a two-compartment open model. The maximal plasma concentration of 1.5 +/- 0.2 mg/mL was achieved at 9 +/- 2 h. The elimination half-life and the mean residence time of ENRO were 1.5 +/- 0.2 and 15.64 h, respectively. The area under the concentration-time curve was calculated as 35 +/- 4 mg(.)h/mL.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The acidic ninhydrin spectrophotometric method (ANSM) for quantitative determination of free and bound sialic acid of milk glycoprotein has been proved to be fast and efficient for routine detection of fraudulent addition of rennet whey to fluid milk. In this research the ANSM was compared with the high performance liquid chromatography (HPLC) method, internationally recommended for caseinomacropeptide (CMP) determination, which besides its high accuracy is more sophisticated and requires trained personnel. For several sample conditions (raw milk and milk with variable added amounts of rennet cheese whey), the methods showed an excellent linear correlation, with r = 0.981 when milk was deproteinized with a 120 g.L-1 final concentration of trichloroacetic acid (TCA) concentration. The best correlations could be seen with final concentrations of 100 g.L-1 and 80 g.L-1 TCA; respectively, r = 0.992 and 0.993.
Resumo:
Dimorphandra mollis: An Alternative as a Source of Flavonoids with Antioxidant Action. Dimorphandra molls fruits are rich in flavonoids rutin and quercetin, which are compounds with high antioxidant activity and can be used to prevent diseases caused by free radicals. The aim of this study was to obtain an extract rich in flavonoids from fruits of D. mollis. The extract was analyzed using the methods of determination by spectrophotometry and high performance liquid chromatography. The presence of rutin and quercetin was identified in the extract, which showed a total flavonoids content of 33.71 To. The extract also showed antioxidant activity as scanvanger of DPPH and ABTS radicals. It was possible to conclude that D. mollis fruits are a rich source of flavonoids with antioxidant action.
Resumo:
A procedure to determine residue concentrations of synthetic pyrethroid insecticides (flumethrin, deltamethrin, cypermethrin and cyhalothrin) in the milk and blood of lactating dairy cows was developed. Extraction was performed with acetonitrile, n-hexane partitioning, and silica gel column cleanup with n-hexane and diethyl ether. Analysis was carried out by high- performance liquid chromatography and ultraviolet detection. Recovery of the four pyrethroids averaged 78 to 91% with a minimum detectable concentration of 0.001 mg/kg. The method was reproducible and sensitive.
Resumo:
A simple, rapid, and sensitive spectrophotometric method for routine analysis of saccharin in commercial noncaloric sweeteners is proposed. This method is based on the reaction of saccharin with tetrachloro-p-benzoquinone (p-chloranil) accelerated by hydrogen peroxide and conducted in an ethanol:acetone (4:1) medium, producing a violet-red compound (γ max = 550 nm). Beer's law is obeyed in a concentration range of 2.05 × 10 -4 to 3.00 × 10 -3 M with an excellent correlation coefficient (r = 0.9998). The detection limit was 1.55 × 10 -5 M, and the effect of interferences on the spectrophotometric measurements was evaluated. The proposed procedure was applied successfully to the determination of saccharin in noncaloric sweeteners. Recoveries were within 99.2-104.3% with standard deviations ranging from to 0.5-1.6%. Results of the proposed method compare very favorably with those given by the high-performance liquid chromatography method recommended by the Food and Drug Administration.