779 resultados para heritage buildings


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Physiological parameters measured by an embedded body sensor system were demonstrated to respond to changes of the air temperature in an office environment. The thermal parameters were monitored with the use of a wireless sensor system that made possible to turn any existing room into a field laboratory. Two human subjects were monitored over daily activities and at various steady-state thermal conditions when the air temperature of the room was altered from 22-23°C to 25-28°C. The subjects indicated their thermal feeling on questionnaires. The measured skin temperature was distributed close to the calculated mean skin temperature corresponding to the given activity level. The variation of Galvanic Skin Response (GSR) reflected the evaporative heat loss through the body surfaces and indicated whether sweating occurred on the subjects. Further investigations are needed to fully evaluate the influence of thermal and other factors on the output given by the investigated body sensor system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an investigation of the natural ventilation cooling potential (NVCP) of office buildings in the five generally recognised climate zones in China using the Thermal Resistance Ventilation (TRV) model, which is a simplified, coupled, thermal and airflow model. The acceptable operative temperature for naturally conditioned space supplied by the ASHARE Standard 55-2004 has been used for the comfort temperature setting. Dynamic simulations for a typical office room in the five representative cities, which are Harbin, Beijing, Shanghai, Kunming and Guangzhou, have been carried out. The study demonstrates that the NVCP depends on the multiple impacts of climate, the building's thermal characteristics, internal gains, ventilation profiles and regimes. The work shows how the simplified method can be used to generate detailed, indoor, operative temperature data based on the various building conditions and control profiles which are used to investigate the NVCP at the strategic design stage. The simulation results presented in this paper can be used as a reference guideline for natural ventilation design in China.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wireless sensor networks (WSNs) have been widely used in pervasive systems such as intelligent buildings. As a vital factor of product cost, energy consuming in WSN has been focused upon, but only via energy harvesting can the problem be overcome radically. This article presents a new approach to harvesting electromagnetic energy for WSN from useless radio frequency (RF) signals transmitted in WSN, with a quantitative analysis showing its feasibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mirror lightpipes are useful for providing healthy and energy-efficient daylight into buildings where windows and skylights are unsuitable, insufficient or generate too much heat gain. The lightpipes have been installed in dozens of buildings in the UK. Field monitoring has been carried out to assess their performance in four different buildings: the headquaters of a major insurance company, a health clinic, a residential building and a college dining hall In those cases where lighipipes with moderate aspect ratios were installed, good illuminance of up to 450 lux has been obtained with internal/external illuminance ratios around 1%. When long and narrow lightpipes with many bends are used, however, the ratio reduced to around 0.1%. These results showed that lightpipes can be effective daylighting devices provided that excessive aspect ratios and numbers of bends are avoided. Lightpipes with larger diameters should be used whenever possible. The lightpipes often improved signiScantly the visual quality af the interior environment, and high user satisfaction was found even in buildings where a relatively low level of daylight was admitted through the lightpipes

Relevância:

20.00% 20.00%

Publicador: