893 resultados para grid-interfaced inverter
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Data-intensive Grid applications require huge data transfers between grid computing nodes. These computing nodes, where computing jobs are executed, are usually geographically separated. A grid network that employs optical wavelength division multiplexing (WDM) technology and optical switches to interconnect computing resources with dynamically provisioned multi-gigabit rate bandwidth lightpath is called a Lambda Grid network. A computing task may be executed on any one of several computing nodes which possesses the necessary resources. In order to reflect the reality in job scheduling, allocation of network resources for data transfer should be taken into consideration. However, few scheduling methods consider the communication contention on Lambda Grids. In this paper, we investigate the joint scheduling problem while considering both optical network and computing resources in a Lambda Grid network. The objective of our work is to maximize the total number of jobs that can be scheduled in a Lambda Grid network. An adaptive routing algorithm is proposed and implemented for accomplishing the communication tasks for every job submitted in the network. Four heuristics (FIFO, ESTF, LJF, RS) are implemented for job scheduling of the computational tasks. Simulation results prove the feasibility and efficiency of the proposed solution.
Resumo:
Data-intensive Grid applications require huge data transfers between grid computing nodes. These computing nodes, where computing jobs are executed, are usually geographically separated. A grid network that employs optical wavelength division multiplexing (WDM) technology and optical switches to interconnect computing resources with dynamically provisioned multi-gigabit rate bandwidth lightpath is called a Lambda Grid network. A computing task may be executed on any one of several computing nodes which possesses the necessary resources. In order to reflect the reality in job scheduling, allocation of network resources for data transfer should be taken into consideration. However, few scheduling methods consider the communication contention on Lambda Grids. In this paper, we investigate the joint scheduling problem while considering both optical network and computing resources in a Lambda Grid network. The objective of our work is to maximize the total number of jobs that can be scheduled in a Lambda Grid network. An adaptive routing algorithm is proposed and implemented for accomplishing the communication tasks for every job submitted in the network. Four heuristics (FIFO, ESTF, LJF, RS) are implemented for job scheduling of the computational tasks. Simulation results prove the feasibility and efficiency of the proposed solution.
Resumo:
In the developed world, grid-connected photovoltaics (PVs) are the fastest-growing segment of the energy market. From 1999 to 2009, this industry had a 42% compound annual growth-rate. From 2009 to 2013, it is expected to grow to 45%, and in 2013 the achievement of grid parity - when the cost of solar electricity becomes competitive with conventional retail (including taxes and charges) grid-supplied electricity - is expected in many places worldwide. Grid-connected PV is usually perceived as an energy technology for developed countries, whereas isolated, stand-alone PV is considered as more suited for applications in developing nations, where so many individuals still lack access to electricity. This rationale is based on the still high costs of PV when compared with conventional electricity. We make the case for grid-connected PV generation in Brazil, showing that with the declining costs of PV and the rising prices of conventional electricity, urban populations in Brazil will also enjoy grid parity in the present decade. We argue that governments in developing nations should act promptly and establish the mandates and necessary conditions for their energy industry to accumulate experience in grid-connected PV, and make the most of this benign technology in the near future. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
This paper proposes three new hybrid mechanisms for the scheduling of grid tasks, which integrate reactive and proactive approaches. They differ by the scheduler used to define the initial schedule of an application and by the scheduler used to reschedule the application. The mechanisms are compared to reactive and proactive mechanisms. Results show that hybrid approach produces performance close to that of the reactive mechanisms, but demanding less migrations.
Resumo:
Fractures of the mandibular angle deserve particular attention because they represent the highest percentage of mandibular fractures and have the highest postsurgical complication rate, making them the most challenging and unpredictable mandibular fractures to treat. Despite the evolution in the treatment of maxillofacial trauma and fixation methods, no single treatment modality has been revealed to be ideal for mandibular angle fractures. Several methods of internal fixation have been studied with great variation in complications rates, especially postoperative infections. Recently, new studies have shown reduction of postsurgical complications rates using three-dimensional plates to treat mandibular angle fractures. Nevertheless, only few surgeons have used this type of plate for the treatment of mandibular angle fractures. The aim of this clinical report was to describe a case of a patient with a mandibular angle fracture treated by an intraoral approach and a three-dimensional rectangular grid miniplate with 4 holes, which was stabilized with monocortical screws. The authors show a follow-up of 8 months, without infection and with occlusal stability.
Resumo:
Bioinformatics is a recent and emerging discipline which aims at studying biological problems through computational approaches. Most branches of bioinformatics such as Genomics, Proteomics and Molecular Dynamics are particularly computationally intensive, requiring huge amount of computational resources for running algorithms of everincreasing complexity over data of everincreasing size. In the search for computational power, the EGEE Grid platform, world's largest community of interconnected clusters load balanced as a whole, seems particularly promising and is considered the new hope for satisfying the everincreasing computational requirements of bioinformatics, as well as physics and other computational sciences. The EGEE platform, however, is rather new and not yet free of problems. In addition, specific requirements of bioinformatics need to be addressed in order to use this new platform effectively for bioinformatics tasks. In my three years' Ph.D. work I addressed numerous aspects of this Grid platform, with particular attention to those needed by the bioinformatics domain. I hence created three major frameworks, Vnas, GridDBManager and SETest, plus an additional smaller standalone solution, to enhance the support for bioinformatics applications in the Grid environment and to reduce the effort needed to create new applications, additionally addressing numerous existing Grid issues and performing a series of optimizations. The Vnas framework is an advanced system for the submission and monitoring of Grid jobs that provides an abstraction with reliability over the Grid platform. In addition, Vnas greatly simplifies the development of new Grid applications by providing a callback system to simplify the creation of arbitrarily complex multistage computational pipelines and provides an abstracted virtual sandbox which bypasses Grid limitations. Vnas also reduces the usage of Grid bandwidth and storage resources by transparently detecting equality of virtual sandbox files based on content, across different submissions, even when performed by different users. BGBlast, evolution of the earlier project GridBlast, now provides a Grid Database Manager (GridDBManager) component for managing and automatically updating biological flatfile databases in the Grid environment. GridDBManager sports very novel features such as an adaptive replication algorithm that constantly optimizes the number of replicas of the managed databases in the Grid environment, balancing between response times (performances) and storage costs according to a programmed cost formula. GridDBManager also provides a very optimized automated management for older versions of the databases based on reverse delta files, which reduces the storage costs required to keep such older versions available in the Grid environment by two orders of magnitude. The SETest framework provides a way to the user to test and regressiontest Python applications completely scattered with side effects (this is a common case with Grid computational pipelines), which could not easily be tested using the more standard methods of unit testing or test cases. The technique is based on a new concept of datasets containing invocations and results of filtered calls. The framework hence significantly accelerates the development of new applications and computational pipelines for the Grid environment, and the efforts required for maintenance. An analysis of the impact of these solutions will be provided in this thesis. This Ph.D. work originated various publications in journals and conference proceedings as reported in the Appendix. Also, I orally presented my work at numerous international conferences related to Grid and bioinformatics.
Resumo:
L’introduzione massiccia dell’elettronica di potenza nel campo degli azionamenti elettrici negli ultimi decenni ha sostanzialmente rivoluzionato la tipologia di alimentazione dei motori elettrici. Da un lato ciò ha migliorato la qualità del controllo della velocità, ma dall’altro ha aggravato le sollecitazioni che gli isolanti delle macchine devono sopportare. Si è infatti passati da tecniche di controllo tradizionali, che consistevano nell’alimentare i motori in alternata direttamente con la rete sinusoidale a 50 Hz (o a 60 Hz), ad alimentazioni indirette, cioè realizzate interponendo tra la rete e la macchina un convertitore elettronico (inverter). Tali dispositivi operano una conversione di tipo ac/dc e dc/ac che permette, come nella modulazione Pulse Width Modulation (PWM), di poter variare la frequenza di alimentazione della macchina, generando una sequenza di impulsi di larghezza variabile. Si è quindi passati dalle tradizionali alimentazioni con forme d’onda alternate sinusoidali a forme di tensione impulsive e ad elevata frequenza, cioè caratterizzate da rapidi fronti di salita e di discesa (dell’ordine di qualche kV/µs). La natura impulsiva di queste forme d’onda ha aggravato la sollecitazione elettrica a cui sono sottoposti i materiali impiegati per l’isolamento dei conduttori degli avvolgimenti delle macchine. E’ importante notare che l’utilizzo dei dispositivi elettronici, che ormai si trovano sparsi nelle reti di bassa tensione, assorbono correnti ad elevato contenuto armonico sul lato di prelievo, hanno quindi un effetto distorcente che altera l’andamento sinusoidale della rete stessa. Quindi, senza opportuni filtri, anche tutte le altre utenze connesse nelle vicinanze, dimensionate per alimentazioni sinusoidali di tipo tradizionale, possono risentire di queste distorsioni armoniche. Per tutti questi motivi è sorta la necessità di verificare l’adeguatezza dei tradizionali isolamenti ad essere in grado di sopportare le sollecitazioni che derivano dall’utilizzo di convertitori elettronici. In particolare, per i motori elettrici tale interrogativo è stato posto in seguito al verificarsi di un elevato numero di guasti inaspettati (precoci), probabilmente imputabile alla diversa sollecitazione elettrica applicata ai materiali. In questa tesi ci si è occupati della progettazione di un inverter di media tensione, che verrà impiegato per eseguire prove sugli avvolgimenti di statore di motori (formette), al fine di condurre successivamente uno studio sull’invecchiamento dei materiali che compongono gli isolamenti. Tale inverter è in grado di generare sequenze di impulsi con modulazione PWM. I parametri caratteristici delle sequenze possono essere modificati in modo da studiare i meccanismi di degradazione in funzione della tipologia delle sollecitazioni applicate. Avendo a che fare con provini di natura capacitiva, il cui isolamento può cedere durante la prova, il sistema deve essere intrinsecamente protetto nei confronti di tutte le condizioni anomale e di pericolo. In particolare deve essere in grado di offrire rapide ed efficaci protezioni per proteggere l’impianto stesso e per salvaguardare la sicurezza degli operatori, dato l’elevato livello delle tensioni in gioco. Per questo motivo è stata pensata un’architettura di sistema ad hoc, in grado di fronteggiare le situazioni anomale in modo ridondante. E’ infatti stato previsto l’inserimento di un sistema di controllo basato sul CompactRIO, sul quale è stato implementato un software in grado di monitorare le grandezze caratteristiche del sistema e le protezioni che affiancheranno quelle hardware, realizzate con dispositivi elettronici. I dispositivi elettronici di protezione e di interfacciamento sono stati studiati, implementati e simulati con PSpice, per poi essere successivamente dimensionati e realizzati su schede elettroniche, avvalendosi del software OrCAD. La tesi è strutturata come segue: - Il primo capitolo tratta, in maniera generale, i motori asincroni trifase, gli inverter e l’invecchiamento dei sistemi isolanti, con particolare interesse alle sollecitazioni meccaniche, termiche ed elettriche nel caso di sollecitazioni impulsive; - Il secondo capitolo riguarda il sistema realizzato nel suo complesso. Inizialmente verrà descritto lo schema elettrico generale, per poi analizzare più nello specifico le varie parti di cui il sistema è composto, come l’inverter di media tensione, il generatore di media tensione, la scheda di disaccoppiamento ottico, la scheda di controllo del generatore di media tensione, la scheda OCP; - Il terzo capitolo descrive le lavorazioni meccaniche eseguite sulle scatole contenti i rami di inverter, la realizzazione delle fibre ottiche e riporta le fasi di collaudo dell’intero sistema. Infine, verranno tratte le conclusioni.
Resumo:
Studio e simulazione di un inverter di tipo Z in grado di innalzare il valore della tensione fornita dalla sorgente fino alla tensione richiesta al carico. L'inverter Z-source può essere utilizzato convenientemente nell'azionamento di un veicolo elettrico, in particolare ad idrogeno.
Resumo:
Research work carried out in focusing a novel multiphase-multilevel ac motor drive system much suitable for low-voltage high-current power applications. In specific, six-phase asymmetrical induction motor with open-end stator winding configuration, fed from four standard two-level three-phase voltage source inverters (VSIs). Proposed synchronous reference frame control algorithm shares the total dc source power among the 4 VSIs in each switching cycle with three degree of freedom. Precisely, first degree of freedom concerns with the current sharing between two three-phase stator windings. Based on modified multilevel space vector pulse width modulation shares the voltage between each single VSIs of two three-phase stator windings with second and third degree of freedom, having proper multilevel output waveforms. Complete model of whole ac motor drive based on three-phase space vector decomposition approach was developed in PLECS - numerical simulation software working in MATLAB environment. Proposed synchronous reference control algorithm was framed in MATLAB with modified multilevel space vector pulse width modulator. The effectiveness of the entire ac motor drives system was tested. Simulation results are given in detail to show symmetrical and asymmetrical, power sharing conditions. Furthermore, the three degree of freedom are exploited to investigate fault tolerant capabilities in post-fault conditions. Complete set of simulation results are provided when one, two and three VSIs are faulty. Hardware prototype model of quad-inverter was implemented with two passive three-phase open-winding loads using two TMS320F2812 DSP controllers. Developed McBSP (multi-channel buffered serial port) communication algorithm able to control the four VSIs for PWM communication and synchronization. Open-loop control scheme based on inverse three-phase decomposition approach was developed to control entire quad-inverter configuration and tested with balanced and unbalanced operating conditions with simplified PWM techniques. Both simulation and experimental results are always in good agreement with theoretical developments.
Resumo:
Modellizzazione della macchina asincrona esafase asimmetrica mediante i vettori di spazio trifase. Determinazione delle trasformazioni esafase dallo studio del campo magnetico rotante. Modellizzazione della macchina asincrona esafase asimmetrica mediante i vettori di spazio esafase. Studio dell’inverter esafase e delle relative tecniche di modulazione. Definizione del modello Simulink dell’azionamento. Studio del ripple della corrente di carico.