967 resultados para finite integral transform technique


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three GST fusion recombinant antigen of Treponema pallidum, described as GST-rTp47, GST-rTp17 and GST-rTp15 were analyzed by Western blotting techniques. We have tested 53 serum samples: 25 from patients at different clinical stages of syphilis, all of them presenting anti-treponemal antibody, 25 from healthy blood donors and three from patients with sexually transmitted disease (STD) other than syphilis. Almost all samples from patients with syphilis presented a strong reactivity with GST-rTp17 antigen. Some samples were non-reactive or showed a weak reaction with GST-rTp47 and/or GST-rTp15, and apparently there was no correlation with the stage of disease. There was no seropositivity among blood donors. No sample reacted with purified GST. We concluded that due to their specificity these recombinant antigens can be used as GST fusion protein for development of syphilis diagnostic assays.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Conservação e Restauro

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Com a necessidade de encontrar uma forma de ligar componentes de forma mais vantajosa, surgiram as ligações adesivas. Nos últimos anos, a utilização de juntas adesivas em aplicações industriais tem vindo a aumentar, substituindo alguns métodos de ligação tradicionais, por apresentarem vantagens tais como, redução de concentração de tensões, reduzido peso e facilidade de processamento/fabrico. O seu estudo permite prever a sua resistência e durabilidade. Este trabalho refere-se ao estudo de juntas de sobreposição simples (JSS), nas quais são aplicados os adesivos comerciais que variam desde frágeis e rígidos, como o caso do Araldite® AV138, até adesivos mais dúcteis, como o Araldite® 2015 e o Sikaforce® 7888. Estes são aplicados em substratos de alumínio (AL6082-T651) em juntas com diferentes geometrias e diferentes comprimentos de sobreposição (L), sendo sujeitos a esforços de tracção. Foi feita uma análise dos valores experimentais fornecidos e uma posterior comparação destes com diferentes métodos numéricos baseados em Elementos Finitos (EF). A comparação foi feita por uma análise de Modelos de Dano Coesivo (MDC) e segundo os critérios baseados em tensões e deformações do Método de Elementos Finitos Extendido (MEFE). A utilização destes métodos numéricos capazes de simular o comportamento das juntas poderá levar a uma poupança de recursos e de tempo. A análise por MDC revelou que este método é bastante preciso, excepto para os adesivos que sejam bastante dúcteis. A aplicação de uma outra lei coesiva pode solucionar esse problema. Por sua vez a análise por MEFE demonstrou que esta técnica não é particularmente adequada para o crescimento de dano em modo misto e, comparativamente com o MDC, a sua precisão é bastante inferior.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The formalin-Tween sedimentation method was compared with the formalin-ether sedimentation for parasitic detection. Of a total 297 fecal specimens examined, 72.1% were positive. The formalin-tween technique was effective for ascertaining helminths, particularly Ascaris lumbricoides, Trichuris trichiura and hookworm eggs; however it has less capability for protozoa detection. This method is simple, inexpensive, less time consuming and highly sensitive when detecting the parasitic infection, particularly when focusing on helminth eggs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid test based on an immunochromatography assay - Determine™ Syphilis TP (Abbott Lab.) for detecting specific antibodies to Treponema pallidum was evaluated against serum samples from patients with clinical, epidemiological and serological diagnosis of syphilis, patients with sexually transmitted disease other than syphilis, and individuals with negative serology for syphilis. The Determine™ test presented the sensitivity of 93.6%, specificity of 92.5%, and positive predictive value and negative predictive value of 95.2% and 93.7%, respectively. One serum sample from patient with recent latent syphilis showed a prozone reaction. Determine™ is a rapid assay, highly specific and easy to perform. This technique obviates the need of equipment and its diagnostic features demonstrate that it may be applicable as an alternative assay for syphilis screening under some emergency conditions or for patients living in remote localities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the fractional Fourier transform (FrFT) is applied to the spectral bands of two component mixture containing oxfendazole and oxyclozanide to provide the multicomponent quantitative prediction of the related substances. With this aim in mind, the modulus of FrFT spectral bands are processed by the continuous Mexican Hat family of wavelets, being denoted by MEXH-CWT-MOFrFT. Four modulus sets are obtained for the parameter a of the FrFT going from 0.6 up to 0.9 in order to compare their effects upon the spectral and quantitative resolutions. Four linear regression plots for each substance were obtained by measuring the MEXH-CWT-MOFrFT amplitudes in the application of the MEXH family to the modulus of the FrFT. This new combined powerful tool is validated by analyzing the artificial samples of the related drugs, and it is applied to the quality control of the commercial veterinary samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we present the operational matrices of the left Caputo fractional derivative, right Caputo fractional derivative and Riemann–Liouville fractional integral for shifted Legendre polynomials. We develop an accurate numerical algorithm to solve the two-sided space–time fractional advection–dispersion equation (FADE) based on a spectral shifted Legendre tau (SLT) method in combination with the derived shifted Legendre operational matrices. The fractional derivatives are described in the Caputo sense. We propose a spectral SLT method, both in temporal and spatial discretizations for the two-sided space–time FADE. This technique reduces the two-sided space–time FADE to a system of algebraic equations that simplifies the problem. Numerical results carried out to confirm the spectral accuracy and efficiency of the proposed algorithm. By selecting relatively few Legendre polynomial degrees, we are able to get very accurate approximations, demonstrating the utility of the new approach over other numerical methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel control technique is investigated in the adaptive control of a typical paradigm, an approximately and partially modeled cart plus double pendulum system. In contrast to the traditional approaches that try to build up ”complete” and ”permanent” system models it develops ”temporal” and ”partial” ones that are valid only in the actual dynamic environment of the system, that is only within some ”spatio-temporal vicinity” of the actual observations. This technique was investigated for various physical systems via ”preliminary” simulations integrating by the simplest 1st order finite element approach for the time domain. In 2004 INRIA issued its SCILAB 3.0 and its improved numerical simulation tool ”Scicos” making it possible to generate ”professional”, ”convenient”, and accurate simulations. The basic principles of the adaptive control, the typical tools available in Scicos, and others developed by the authors, as well as the improved simulation results and conclusions are presented in the contribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Signal Processing: Algorithms, Architectures, Arrangements, and Applications (SPA), 2013

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we propose a novel fully probabilistic solution to the stereo egomotion estimation problem. We extend the notion of probabilistic correspondence to the stereo case which allow us to compute the whole 6D motion information in a probabilistic way. We compare the developed approach against other known state-of-the-art methods for stereo egomotion estimation, and the obtained results compare favorably both for the linear and angular velocities estimation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O método de união com ligações adesivas está cada vez mais a ser utilizado na conceção de estruturas mecânicas, por causa das vantagens significativas desta técnica em comparação com as ligações tradicionais. De facto, as juntas com ligação adesiva estão sob investigação intensa há bastante tempo. Entre as vantagens, destaca-se a redução de peso e possibilidade de unir diferentes materiais, incluindo compósitos, sem danificar as estruturas a ligar. Os adesivos comerciais variam desde resistentes e frágeis (por exemplo, Araldite® AV138) a menos resistentes e dúcteis (por exemplo, Araldite® 2015). Uma nova família de adesivos de poliuretano combina elevada resistência e ductilidade (por exemplo, Sikaforce® 7888). Este trabalho compara o desempenho à tração dos três adesivos supracitados, em juntas de alumínio (Al6082-T651) de sobreposição simples e dupla, com variação dos valores de comprimento de sobreposição (LO). A análise numérica de modelos de dano coesivo (MDC) foi realizada para analisar as tensões de arrancamento (oy) e as de corte (txy) na camada adesiva, para estudar a variável de dano do MDC durante o processo de rotura e para avaliar a capacidade MDC na previsão da resistência da junta. A análise da resistência e da variável de dano ajudou na compreensão das diferenças entre os adesivos no que se refere ao processo de rotura e resistência da junta. Observou-se que as juntas de sobreposição dupla apresentam uma distribuição de tensões bastante mais favorável relativamente às juntas de sobreposição simples, principalmente devido à eliminação da flexão do substrato interior. Como resultado, a resistência destas juntas foi tipicamente superior ao dobro da observada para as juntas de sobreposição simples, com exceção de algumas configurações de junta em que houve plastificação extensa ou mesmo rotura dos substratos por tração. O trabalho proposto permitiu também concluir que as previsões MDC são tipicamente precisas, e qual a família de adesivos é mais adequada para cada configuração de junta, com a clara vantagem para o Sikaforce® 7888. Como resultado deste trabalho, foram propostas diretrizes de conceção para juntas adesivas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Progressive disseminated histoplasmosis (PDH) is an increasingly common cause of infection in patients with acquired immune deficiency syndrome (AIDS). We report 21 cases of PDH associated with AIDS diagnosed by lysis-centrifugation blood culture method. The most prevalent clinical findings were fever, weight loss, respiratory symptoms, and mucocutaneous lesions. Chest roentgenogram showed diffuse pulmonary infiltrates in 13 of 21 patients (62%). Brochoalveolar fluid has yelded positive culture in four patients only in medium with cycloheximide.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The integrity of multi-component structures is usually determined by their unions. Adhesive-bonding is often used over traditional methods because of the reduction of stress concentrations, reduced weight penalty, and easy manufacturing. Commercial adhesives range from strong and brittle (e.g., Araldite® AV138) to less strong and ductile (e.g., Araldite® 2015). A new family of polyurethane adhesives combines high strength and ductility (e.g., Sikaforce® 7888). In this work, the performance of the three above-mentioned adhesives was tested in single lap joints with varying values of overlap length (LO). The experimental work carried out is accompanied by a detailed numerical analysis by finite elements, either based on cohesive zone models (CZM) or the extended finite element method (XFEM). This procedure enabled detailing the performance of these predictive techniques applied to bonded joints. Moreover, it was possible to evaluate which family of adhesives is more suited for each joint geometry. CZM revealed to be highly accurate, except for largely ductile adhesives, although this could be circumvented with a different cohesive law. XFEM is not the most suited technique for mixed-mode damage growth, but a rough prediction was achieved.