895 resultados para finite element modeling
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The Finite Element Method (FEM) is a way of numerical solution applied in different areas, as simulations used in studies to improve cardiac ablation procedures. For this purpose, the meshes should have the same size and histological features of the focused structures. Some methods and tools used to generate tetrahedral meshes are limited mainly by the use conditions. In this paper, the integration of Open Source Softwares is presented as an alternative to solid modeling and automatic mesh generation. To demonstrate its efficiency, the cardiac structures were considered as a first application context: atriums, ventricles, valves, arteries and pericardium. The proposed method is feasible to obtain refined meshes in an acceptable time and with the required quality for simulations using FEM.
Resumo:
Objective: This study evaluated the effect of quantity of resin composite, C-factor, and geometry in Class V restorations on shrinkage stress after bulk fill insertion of resin using two-dimensional finite element analysis.Methods: An image of a buccolingual longitudinal plane in the middle of an upper first premolar and supporting tissues was used for modeling 10 groups: cylindrical cavity, erosion, and abfraction lesions with the same C-factor (1.57), a second cylindrical cavity and abfraction lesion with the same quantity of resin (QR) as the erosion lesion, and then all repeated with a bevel on the occlusal cavosurface angle. The 10 groups were imported into Ansys 13.0 for two-dimensional finite element analysis. The mesh was built with 30,000 triangle and square elements of 0.1 mm in length for all the models. All materials were considered isotropic, homogeneous, elastic, and linear, and the resin composite shrinkage was simulated by thermal analogy. The maximum principal (MPS) and von Mises stresses (VMS) were analyzed for comparing the behavior of the groups.Results: Different values of angles for the cavosurface margin in enamel and dentin were obtained for all groups and the higher the angle, the lower the stress concentration. When the groups with the same C-factor and QR were compared, the erosion shape cavity showed the highest MPS and VMS values, and abfraction shape, the lowest. A cavosurface bevel decreased the stress values on the occlusal margin. The geometry factor overcame the effects of C-factor and QR in some situations.Conclusion: Within the limitations of the current methodology, it is possible to conclude that the combination of all variables studied influences the stress, but the geometry is the most important factor to be considered by the operator.
Resumo:
In this paper, natural frequencies were analyzed (axial, torsional and flexural) and frequency response of a vertical rotor with a hard disk at the edge through the classical modal and complex analysis. The equation that rules the movement was obtained through the Lagrangian formulation. The model considered the effects of bending, torsion and axial deformation of the shaft, besides the gravitational and gyroscopic effects. The finite element method was used to discretize the structure into hollow cylindrical elements with 12 degrees of freedom. Mass, stiffness and gyroscopic matrices were explained consistently. The classical modal analysis, usually applied to stationary structures, does not consider an important characteristic of rotating machinery which are the methods of forward and backward whirl. Initially, through the traditional modal analysis, axial and torsional natural frequencies were obtained in a static shaft, since they do not suffer the influence of gyroscopic effects. Later research was performed by complex modal analysis. This type of tool, based on the use of complex coordinates to describe the dynamic behavior of rotating shaft, allows the decomposition of the system in two submodes, backward and forward. Thus, it is possible to clearly visualize that the orbit and direction of the precessional motion around the line of the rotating shaft is not deformed. A finite element program was developed using MATLAB (TM) and numerical simulations were performed to validate this model. Natural frequencies and directional frequency forced response (dFRF) were obtained using the complex modal analysis for a simple vertical rotor and also for a typical drill string used in the construction of oil wells.
Resumo:
Mass reduction coupled with the mechanical performance in service has been the goal of many projects related to the transport area, considering the advantages that mass reduction can bring. However, make a simple material substitution without design a new geometry to corroborate for the best component performance, often makes the replacement unviable. In this study, it was investigated the advantages of replacing the prototype BAJA SAE front suspension lower arm of Equipe Piratas do Vale de BAJA SAE - Universidade Paulista, Campus Guaratinguetá, actually produced with steel, for a new component made of carbon fiber composite. The new geometry has been developed to provide the best possible performance for this component and your easy manufacturing. The study was done using the 3D modeling tools and computer simulations via finite element method. The first stage of this work consisted on calculation of the estimated maximum contact force tire / soil in a prototype landing after jump at one meter high, drop test in the laboratory with the current vehicle, current front suspension lower arm 3D modeling, finite element simulation and analysis of critical regions. After all current component analysis, a new geometry for the part in study was designed and simulated in order to reduce the component mass and provide a technological innovation using composite materials. With this work it was possible to obtain a theoretical component mass reduction of 25,15% maintaining the mechanical strength necessary for the appropriated component performance when incited
Modelagem em 3D de uma patela humana e análise de esforços utilizando o método dos elementos finitos
Resumo:
Throughout the history of medicine surgeons realized the importance of the patella to the functioning of the knee. The main function of the patella is to increase the mechanical efficiency of the quadriceps tendon and knee extensor mechanism. It was found that 50% to 80% of the fractures without deviation of the patella have the transversal pattern, possibly due to excessive tensile forces applied to the extensor mechanism. The purpose of this study is to analyze the loads to which a patella is submitted during a normal extension movement of knee. This analysis will be done by modeling a 3D patella and subsequent load simulation as, described in medical literature, using the finite element method
Resumo:
This work aims the design and analysis of a thrust frame system for a liquid fuel rocket engine. The project was developed following the design requirements established by the Division of Space Propulsion of the Institute of Aeronautics and Space. The layout of the structure was developed with the aid of a software of 3D modeling and static and dynamic analysis were performed by using a finite element package. The results of the analyzes helped in defining the layout of the structure which met all design requirements. The safety factor and the mass achieved were comfortably low, which may be useful in the future because the liquid fuel rocket engine is still in development
Resumo:
The finite element method is of great importance for the development and analysis of a new product being designed or already on the market, and that requires some specific request or special application. The tower crane, being an essential equipment for modern construction to increase productivity and safety on construction sites, is required for many types of special applications day after day, in many kinds of work. Paying attention to this growing need for handling special projects for the tower crane, faced with the importance and necessity of development and improvement of knowledge in more accurate and practical calculation methods such as the finite element method , for greater agility and precision in the response to a new project. The tower crane is defined by the maximum load moment that it can act with a certain amount of load. The tower crane which will be analyzed in this work , for example, is a tower crane with a resulting capacity of 85 Metric Tons which are considered basic dimensions data of a fisical tower crane of a crane company Liebherr in Guaratinguetá . Thus, the project analysis will begin with the threedimensional representation of the crane lines with AutoCAD software , conversion of this model to the format accepted ANSYS Workbench and completion of 3D modeling of structural components in Design module ANSYS software. After structural modeling is completed, the simulation is performed in static simulation of ANSYS Workbench software mode. The standards will be adopted to DIN (Deutsches Institut für Normung) and EN 14439 (Europäische Normung 14439) and some NR 's related to specific security class of tower cranes, which will be referred throughout the work
Resumo:
The objective of this study was to develop a model that allows testing in the wind tunnel at high angles of attack and validates its most critical components by analyzing the results of simulations in finite element software. During the project this structure suffered major loads identified during the flight conditions and, from these, we calculated the stresses in critical regions defined as the parts of the model that have higher failure probabilities. All aspects associated with Load methods, mesh refining and stress analysis were taken into account in this approach. The selection of the analysis software was based on project needs, seeking greater ease of modeling and simulation. We opted for the software ANSYS® since the entire project is being developed in CAD platforms enabling a friendly integration between software's modeling and analysis
Resumo:
The purpose of this study was to evaluate the effect of occlusal contact area for loading on the cuspal defection and stress distribution in a first premolar restored with a high elastic modulus restorative material. The Rhinoceros 4.0 software was used for modeling the three-dimensional geometries of dental and periodontal structures and the inlay restoration. Thus, two different models, intact and restored teeth with three occlusal contact areas, 0.1, 0.5 and 0.75 mm(2), on enamel at the occlusal surface of buccal and lingual cusps. Finite element analysis (FEA) was performed with the program ANSYS (Workbench 13.0), which generated a mesh with tetrahedral elements with greater refinement in the regions of interest, and was constrained at the bases of cortical and trabecular bone in all axis and loaded with 100 N normal to each contact area. To analysis of maximum principal stress, the smaller occlusal contact area showed greater compressive stress in region of load application for both the intact and inlay restored tooth. However, tensile stresses at the occlusal isthmus were similar for all three tested occlusal contact areas (60 MPa). To displacement of the cusps was higher for teeth with inlay (0.46-0.48 mm). For intact teeth, the smaller contact area showed greater displacement (0.10 mm). For teeth with inlays, the displacement of the cusps were similar in all types of occlusal area. Cuspal displacement was higher in the restored tooth when compared to the intact tooth, but there were no significant variations even with changes in the occlusal contact area. RELEVANCE CLINICAL: Occlusal contacts have a great influence on the positioning of teeth being able to maintain the position and stability of the mandible. Axial loads would be able to generate more uniform stress at the root presenting a greater concentration of load application in the point and the occlusal surface. Thus, is necessary to analyze the relationship between these occlusal contacts as dental wear and subsequent occlusal interferences.
Resumo:
The aim of this study was to evaluate the biomechanical behavior of different implant connection types, by means of three-dimensional finite element analysis. 3 Three-dimensional models were created with a graphic modeling software: SolidWorks 2006 and Rhinoceros 4.0, and InVesalius (CTI, São Paulo, Brasil), the bone was obtained by computerized tomography of a sagittal section of the molar region. The model was composed by bone block with an implant (4 x 10 mm) (Conexão Sistemas de Prótese, São Paulo), with different implant connections: external hex, internal hex and Morse-taper with the corresponding prosthetic component Ucla or Morse-taper abutment. The Three-dimensional models were transferred to finite element software Femap 10.0 (Siemens PLM Software Inc., CA, USA), to generate a mesh, boundary conditions and loading. An axial (200N) and oblique load (100N) was applied on the occlusal surface of the crowns. Analyses were performed using the finite element software NEiNastran 9.0 (Noran Engineering, Inc., USA) and transferred to the Femap 10.0 to obtain the results; after the results were visualized using von Mises stress maps and Maximum stress principal. The results showed the stress distribution was similar between models, with a little superiority of Morse-taper connection. It was concluded that: the three connection types were biomechanical viable; The Morse-taper connection presented the better internal stress distribution; there was not significant biomechanical differences on the bone.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The most important property of austenitic stainless steels is corrosion resistance. In these steels, the transition between paramagnetic and ferromagnetic conditions occurs at low temperatures. Therefore, the use of austenitic stainless steels in conditions in which ferromagnetism absence is important can be considered. On the other hand, the formation of strain-induced martensite is detected when austenitic stainless steels are deformed as well as machined. The strain-induced martensite formed especially in the machining process is not uniform through the chip and its formation can also be related to the Md temperature. Therefore, both the temperature distribution and the gradient during the cutting and chip formation are important to identify regions in which martensite formation is propitiated. The main objective here is evaluate the strain-induced martensite formation throughout machining by observing microstructural features and comparing these to thermal results obtained through finite element method analysis. Results show that thermal analysis can give support to the martensite identified in the microstructural analysis.