724 resultados para denture rebasing
Resumo:
PURPOSE. Adequate passive-fitting of one-piece cast 3-element implant-supported frameworks is hard to achieve. This short communication aims to present an alternative method for section of one-piece cast frameworks and for casting implant-supported frameworks. MATERIALS AND METHODS. Three-unit implant-supported nickel-chromium (Ni-Cr) frameworks were tested for vertical misfit (n = 6). The frameworks were cast as one-piece (Group A) and later transversally sectioned through a diagonal axis (Group B) and compared to frameworks that were cast diagonally separated (Group C). All separated frameworks were laser welded. Only one side of the frameworks was screwed. RESULTS. The results on the tightened side were significantly lower in Group C (6.43 +/- 3.24 mu m) when compared to Groups A (16.50 +/- 7.55 mu m) and B (16.27 +/- 1.71 mu m) (P<.05). On the opposite side, the diagonal section of the one-piece castings for laser welding showed significant improvement in the levels of misfit of the frameworks (Group A, 58.66 +/- 14.30 mu m; Group B, 39.4.8 +/- 12.03 mu m; Group C, 23.13 +/- 8.24 mu m) (P<.05). CONCLUSION. Casting diagonally sectioned frameworks lowers the misfit levels. Lower misfit levels for the frameworks can be achieved by diagonally sectioning one-piece frameworks. [J Adv Prosthodont 2012;4:89-92]
Resumo:
The aim of this study was to evaluate the efficacy of experimental toothpastes for removing denture biofilm by means of a randomized crossover trial. Thirty volunteers brushed their dentures using a brush and four pastes: (1) Corega refreshing mint (control), (2)0.2% chloramine T, (3)1.0% chloramine T, and (4) 0.01% fluorosurfactant. Each paste was used for 7 days, and participants were randomized to use them according to one of four sequences. Biofilm was disclosed (neutral red) after each period, photographed, and quantified by means of a software program. All experimental toothpastes were similar to the control in terms of posttreatment biofilm coverage. Int J Prosthodont 2012;25:157-159.
Resumo:
Objective: Antimicrobial photodynamic therapy (aPDT) has been used to combat local infections, and it consists of the combination of a photosensitizer, a light source, and reactive oxygen species (ROS) to kill microbial cells. In this study, we evaluated the effectiveness of aPDT in the treatment of candidiasis in HIV-infected patients. Methods: Twenty-one patients were divided into three groups. Control group (CG) was treated with the conventional medication for candidiasis (fluconazole 100 mg/day during 14 days). Laser group (LG) was subjected to low-level laser therapy (LLLT), wavelength 660 nm, power of 30 mW, and fluence of 7.5 J/cm(2), in contact with mucosa during 10 sec on the affected point. An aPDT group (aPDTG) was treated with aPDT, that is, combination of a low-power laser and methylene blue 450 mu g/mL. Pre-irradiation time was 1 min. Parameters of irradiation were the same ones as for the LG, and patients were single irradiated. Patients were clinically evaluated and culture analysis was performed before, immediately after, and 7, 15, and 30 days after the treatment. Results: Our results showed that fluconazole was effective; however, it did not prevent the return of the candidiasis in short-term. LLLT per se did not show any reduction on Candida spp. aPDT eradicated 100% of the colonies of this fungus and the patients did not show recurrence of candidiasis up to 30 days after the irradiation. Conclusions: These findings suggest that aPDT is a potential approach to oral candidiasis treatment in HIV-infected patients.
Resumo:
Two cases of swallowing of foreign material related to dental implants during dental practice are described. A conservative approach by clinical-radiographic follow-up was performed in both cases; however, one of the patients required colonoscopy under general anesthesia for the removal of the impacted foreign body from the intestinal region. These complications not only have associated economic cost but also carry the risk of malpractice litigation against the professional; thus, the surgeon was responsible for all the costs of hospital and surgery management of this case. Details of the clinical signs, radiographic examinations, type of treatment, and follow-up are presented.
Resumo:
Purpose: This study aimed to investigate the antimicrobial properties and cytotoxicity of the monomer methacryloyloxyundecylpyridinium bromide (MUPB), an antiseptic agent capable of copolymerizing with denture base acrylic resins. Materials and Methods: The antimicrobial activity of MUPB was tested against the species Candida albicans, Candida dubliniensis, Candida glabrata, Lactobacillus casei, Staphylococcus aureus, and Streptococcus mutans. The minimum inhibitory and fungicidal/bactericidal concentrations (MIC, MFC/MBC) of MUPB were determined by serial dilutions in comparison with cetylpyridinium chloride (CPC). The cytotoxic effects of MUPB at concentrations ranging from 0.01 to 1 g/L were assessed by MTT test on L929 cells and compared with methyl methacrylate (MMA). The antimicrobial activity of copolymerized MUPB was tested by means of acrylic resin specimens containing three concentrations of the monomer (0, 0.3, 0.6% w/w). Activity was quantified by means of a disc diffusion test and a quantification of adhered planktonic cells. Statistical analysis employed the Mann-Whitney test for MIC and MFC/MBC, and ANOVA for the microbial adherence test (a= 0.05). Results: MUBP presented lower MIC values when compared with CPC, although differences were significant for C. dubliniensis and S. mutans only (p= 0.046 and 0.043, respectively). MFC/MBC values were similar for all species except C. albicans; in that case, MUPB presented significantly higher values (p= 0.046). MUPB presented higher cytotoxicity than MMA for all tested concentrations (p < 0.001) except at 0.01 g/L. Irrespective of the concentration incorporated and species, there was no inhibition halo around the specimens. The incorporation of MUPB influenced the adhesion of C. albicans only (p= 0.003), with lower CFU counts for the 0.6% group. Conclusions: It was concluded that non-polymerized MUPB has an antimicrobial capacity close to that of CPC and high cytotoxicity when compared with MMA. The antimicrobial activity of MUPB after incorporation within a denture base acrylic resin did not depend on its elution, but was shown to be restricted to C. albicans.
Resumo:
The aim of this study was to evaluate the effectiveness of photodynamic therapy (PDT) for the disinfection of complete dentures. Biofilm samples were collected from dentures of 60 denture users who were randomly divided into four experimental groups (n = 15 each): subjects whose maxillary dentures were sprayed with 50 and 100 mg/l of PhotogemA (R) suspension (groups P50S and P100S) and patients whose maxillary dentures were treated with 50 and 100 mg/l of PhotogemA (R) gel (groups P50G and P100G). Dentures with photosensitizers were left in the dark for 30 min (pre-irradiation time) and then irradiated with blue LED light at 37.5 J/cm(2) (26 min). Denture samples were taken with sterile cotton swab before (left side surfaces) and after (right side surfaces) PDT. All microbial material was diluted and plated on selective media for Candida spp., Staphylococcus mutans spp., streptococci and a non-selective media. After incubation (48 h/37A degrees C), the number of colony-forming units (cfu/ml) was counted. Microorganisms grown on selective media were identified using biochemical methods before and after PDT. The data were submitted to McNemar and Kruskal-Wallis tests (alpha = 0.05). No growth after PDT was observed in 60, 53, 47, and 40% of dentures from P100G, P50G, P100S, and P50S groups, respectively. When evidence of microorganisms' growth was observed, PDT regimens eliminated over 90% of microorganisms on dentures. This clinical study showed that PDT was effective for disinfecting dentures.
Resumo:
From a recent perspective the morse-taper dental implants connections are increasingly being used as an alternative for replacement of a missing teeth. Nevertheless, there are a large variety of prosthetic components available on the market with some limitations regarding the final prothesis. This article demonstrated the difficulties and limitations of prosthesis implant-retained connections when using morse-taper implants (with a prosthetic index) case in which the surgical placement of the implant wasn’t successfully performed. The alternative to overcome this scenario was the technique using the tube screw over the top of a mini abutment component. It was possible to manufacture and to have satisfactory adaptation, achieving the satisfaction of the patient, restoring function and esthetics.
Resumo:
The main objective of this paper was to discuss the importance of the reverse planning as guidance to surgical procedures on immediate loading implant-retained prosthesis, presenting a case report. Such design aims to define anchorage orientation after determination of prosthetic design. This is quite important because the possibility of success of cases with this kind of planning may achieve high levels of satisfaction. Another important aspect is the possibility of fast and definitive restoration of patients’ function and aesthetics
Resumo:
Loss of posterior teeth may cause an imbalance in the stomatognathic system. Overlay removable partial dentures (ORPD) are a reversible and relatively inexpensive treatment for patients with severely worn teeth. This paper presents a treatment with ORPD in a 55-year-old male patient who had severe attrition in the maxillary and mandibular teeth, temporomandibular joint pain and reduced vertical dimension of occlusion (VDO). The treatment consisted in the reestablishment of the VDO using Lucia’s jig, fabricating removable partial denture with reconstruction of the worn teeth without preparation. This therapy can be used as an alternative treatment to provide esthetic, function and stable occlusion in patients with severely worn teeth.
Resumo:
Introduction. Ectodermal Dysplasias are a heterogeneous group of inherited disorders characterized by dysplasia of tissues of ectodermal origin (hair, nails, teeth, skins and glands). Clinically, it may be divided into two broad categories: the X-linked hypoidrotic form and the hidrotic form. Hypohidrotic Ectodermal Dysplasia (H.E.D) is characterized by the triad oligo-anodontia, hypotricosis, hypo-anhydrosis (Christ-Siemens-Tourane syndrome). The incidence of HED is about 1/100,000. Mutation in the actodysplasin-A (EDA) and ectodysplasin-A receptor (EDAR) genes are responsible for X-linked and autosomal HED. The clinical features include sparse, fine hair, missing or conical-shaped teeth, decreased sweat and mucous glands, hypoplastic skin, and heat intolerance with exercise or increased ambient temperature. Complete or partial anodontia and malformation of teeth are the most frequent dental findings. Incisors and canines are often conical-shaped while primarily second molars, if present, are mostly affected by taurodontism. Treatment is supportive and includes protection from heat exposure, early prosthetic rehabilitation, skin, hair ear, nose and nail care, and genetic counseling for family planning. The diagnosis of HED in the neonatal and early infancy period may be difficult since sparse hair and absent teeth are normal finding at this age. In childhood the diagnosis is more easily made on the basis of history and clinical examination. Dental abnormalities are the most common complaint. Prosthetic rehabilitation has been recommended as an essential part of the management of HED because is important from functional, esthetic, and psychological standpoint. A team approach that includes input from a pediatric dentist, an orthodontist, a prosthodontist, and an oral and maxillofacial surgeon is necessary for a successful outcome. Conventional prosthodontic rehabilitation in young patient is often difficult because of the anatomical abnormalities of existing teeth and alveolar ridges. The conical shaped teeth and “knife-edge” alveolar ridges result in poor retention and instability of dentures. Moreover, denture must permit jaws expansion and a correct pattern of growth. Materials and Methods. Complete removable dentures were provided to allow for normal physiological development and a corrected masticatory function. Initial maxillary and mandibular impressions were made with smallest stock trays and irreversible hydrocolloid and then final impressions ware made with light-bodied polysulfide rubber base impression material. A base of autopolymerizing resin was constructed and a wax rim was added to the base. The patient’s vertical dimension of occlusion was established by assessing phonetic and esthetic criteria. Preliminary occlusal relations were recorded, and the mandibular cast was mounted on the articulator. Acrylic resin teeth specific for children dentures were selected and mounted. The dentures were tried in and, after proper adjustments, were inserted. The patients were monitored clinically every month to fit prostheses. Cephalometric radiographs were taken every 6 month with the prostheses in place in order to evaluate correct pattern of growth. Cephalometric measurements were realized and used to evaluate the effect of rehabilitation on craniofacial growth. Cephalometric measurements of sound patients were compared with ED patients. After two month expander screws (three-way screw in the upper denture and two-way the lower one)were inserted in each denture in order to permit the expansion of the denture and the jaws growth. Where conical teeth were present, composite crown were realized and luted to improve the esthetic and phonesis. In order to improve retention the placement of endosseous implants was carried out. TC 3D Accuitomo was performed and a resin model of mandibular bone of the patient was realized. At the age of 11 years two implants were inserted into anterior mandible in a child with anodontia. Despite a remarkable multi-dimensional atrophy of the mandibular alveolar process, the insertion of two tapered screw implants (SAMO Smiler, diameter 3.8, length 10 mm). After a submerged healing period of two-three month, the implants were exposed. Implants were connected with an expansion guide that permits mandibular growth and prosthetic retention. The amount of mandibular growth was also evaluate dusing the expansion guide. Results. Early oral rehabilitation improve oral function, phonesis and esthetic, reducing social impairment. Treated patients showed normal cephalometric measurement. Early rehabilitation is able to prevent the prognatissm of the mandibula . The number of teeth was significantly related to several changes in craniofacial morphology. Discussion. In the present study the 5,3% of ED patients showed hypodontia, the l’89,4% di oligodontia, and the 5,3% di anodontia. The cephalometric analysis supports that ED patients showed midface hypoplasia. ED groups showed an increased pogonion to nasion measurement than sound patients, indicative of class III tendency. The present study demonstrated that number of teeth was significantly correlated with deviation of cephalometric measurements from normality. Oligoanodontia is responsible for changing of cephalometric measuraments also on sagittal plane with a class III tendency. Maxillary jaw showed a retrused position related to the presence of hypodontia.
Resumo:
PURPOSE: The mandibular implant overdenture is a popular treatment modality and is well documented in the literature. Follow-up studies with a long observation period are difficult to perform due to the increasing age of patients. The present data summarize a long-term clinical observation of patients with implant overdentures. MATERIALS AND METHODS: Between 1984 and 1997, edentulous patients were consecutively admitted for treatment with an implant overdenture. The dentures were connected to the implants by means of bars or ball anchors. Regular maintenance was provided with at least one or two scheduled visits per year. Recall attendance and reasons for dropout were analyzed based on the specific history of the patient. Denture maintenance service, relining, repair, and fabrication of new dentures were identified, and complications with the retention devices specified separately. RESULTS: In the time period from 1984 to 2008, 147 patients with a total of 314 implants had completed a follow-up period of >10 years. One hundred one patients were still available in 2008, while 46 patients were not reexamined for various reasons. Compliance was high, with a regular recall attendance of >90%. More than 80% of dentures remained in continuous service. Although major prosthetic maintenance was rather low in relation to the long observation period, visits to a dental hygienist and dentist resulted in an annual visit rate of 1.5 and 2.4, respectively. If new dentures became necessary, these were made in student courses, which increased the treatment time and number of appointments needed. Complications with the retention devices consisted mostly of the mounting of new female retainers, the repair of bars, and the changing of ball anchors. The average number of events and the rate of prosthetic service with ball anchors were significantly higher than those with bars. Twenty-two patients changed from ball anchors to bars; 9 patients switched from a clip bar to a rigid U-shaped bar. CONCLUSIONS: This long-term follow-up study demonstrates that implant overdentures are a favorable solution for edentulous patients with regular maintenance. In spite of specific circumstances in an aging population, it is possible to provide long-term care, resulting in a good prognosis and low risk for this treatment modality. For various reasons the dropout rate can be considerable in elderly patients and prosthetic service must be provided regularly.
Resumo:
This case report documents the prosthetic rehabilitation of a patient showing the typical features of combination syndrome. This case documentation gives a general overview of the suspected development and the prevalence of this "syndrome". A treatment option should be shown by the example of a patient from the starting situation until the prosthetic therapy by means of a complete maxillary denture and an implant-supported mandibular overdenture rigidly retained with a milled bar.
Resumo:
The wear of telescopic crowns is a common problem often reducing the patient's satisfaction with the denture and resulting in a renewal of the denture. The study aims to compare the wear behavior of conical crowns using electroplated copings (group E ) with standard telescopic crowns with cast female parts (group C).
Resumo:
The aim of this study was to examine the wear behavior of conical crowns with electroplated gold copings that are used to connect implants and teeth to a removable denture. Gold alloy and zirconium dioxide ceramic crowns were compared.
Resumo:
This study deals with the development of the retentive forces of double crowns intraorally measured. Twenty-five combined fixed-removable prostheses with a total of 84 double crowns were included in the study. The intraoral measurement was performed at 72 defined measuring points directly adjacent to the double crowns of the dentures. The measurement was performed 4-6 weeks (baseline), 6 months (recall 1), and 18 months (recall 2) after the insertion of the restoration. A specifically designed measuring device was used. The median values for the single measuring points reached 4.705 N at the baseline, 5.190 N after 6 months, and 3.740 N after 18 months. The measured values were analyzed according to differences between the median retention forces at the three defined points in time. The statistical analysis of the median values showed no statistical difference for the retention force change after 6 months but for the decrease until the second recall (Mann-Whitney test). The retention force per denture was calculated by a summation of the single measuring points. At the baseline, 12.9 N was reached. The forces did only decrease slightly and were not statistically significant. The results indicate that retention force values of double crowns, measured intraorally at the patient, do not relevantly change clinically within the first 1.5 years. Within the limitations of this study, it can be stated that wear does not influence the retentive forces of double crowns within the first 18 months. After this period the retention force should be still sufficient for denture retention.