978 resultados para dental cements
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The aim of this study was to evaluate the micro-shear bond strength of 5 adhesive systems to enamel, one single-bottle acid-etch adhesive (O), two self-etching primers (P) and two all-in-one self-etching adhesives (S). Method: Sixty premolar enamel surfaces (buccal or lingual) were ground flat with 400- and 600-grit SiC papers and randomly divided into 5 groups (n=12), according to the adhesive system.. SB2 - Single Bond 2 (O); CSE - Clearfil SE Bond (P); ADS - AdheSE (P); PLP - Adper Prompt L-Pop (S); XE3 - Xeno III (S). Tygon tubing (inner diameter of 0.8mm) restricted the bonding area to obtain the resin composite (Z250) cylinders. After storage in distilled water at 37 degrees C for 24h and thermocycling, micro-shear testing was performed (crosshead speed of 0.5mm/min). Data were submitted to one-way ANOVA and Tukey test (a=5%). Samples were also subjected to stereomicroscopic and SEM evaluations after micro-shear testing. Mean bond strength values (MPa +/- SD) and the results of Tukey test were: SB2: 36.36(+/- 3.34)a; ADS: 33.03(+/- 7.83)a; XE3: 32.76(+/- 5.61)a; CSE: 30.61(+/- 6.68)a; PLP: 22.17(+/- 6.05)b. Groups with the same letter were not statistically different. It can be concluded that no significant difference was there between SB2, ADS, XE3 and CSE, in spite of different etching patterns of these adhesives. Only PLP presented statistically lower bond strengths compared with others. J Clin Pediatr Dent 35(3): 301-304, 2011
Resumo:
This study aimed to describe how to evaluate and quantify the ergonomic satisfaction level of dental clinics rooms. Requirements for design, production and selection of dental equipment as described in ISO/TC-106/SC-6-N-411, support more comprehensive studies for an ergonomic evaluation and ergo design of the dental workstations. It was created a checklist of ergonomics requirements which is supported by Standards ISO/FDI and acquired by mean of a literature review. According to information exposed at the document of the Ergonomics Society of Dental Ergonomics - ESDE we can consider that the elaboration of an ergonomic evaluation protocol regard to the dental workstation is an important demand for the ergonomics, particularly in relation to the performance of the ergonomic design which presents qualified to assist to dental equipment manufactures. By this means, the identification of the evaluation factors pointed in ISO/TC 106/SC 6 N 411 offers the basic information to the process of elaboration of this protocol addressed by the described general guidelines.
Resumo:
Objectives: To evaluate the microtensile bond strength (mu TBS) of one-(Xeno III, Dentsply) and two-step (Tyrian-One Step Plus, Bisco) self-etching adhesive systems bonded to dentin and cemented to chemically cured (C&B Metabond) or light-cured paste of a dual-cure resin cement (Variolink II, Ivoclar) within a short (24 h) and long period of evaluation (90 days). Material and Methods: Forty recently extracted human molars had their roots removed and their occlusal dentin exposed and ground wet with 600-grit SiC paper. After application of one of the adhesives, the resin cement was applied to the bonded surface and a composite resin block was incrementally built up to a height of 5 mm (n = 10). The restored teeth were stored in distilled water at 37 C for 7 days. The teeth were then cut along two axes (x and y), producing beam-shaped specimens with 0.8 mm(2) cross-sectional area, which were subjected to mu TBS testing at a crosshead speed of 0.05 mm/min and stressed to failure after 24 h or 90 days of storage in water. The mu TBS data in MPa were subjected to three-way analysis of variance and Tukey's test (alpha = 0.05). Results: The interaction effect for all three factors was statistically significant (three-way ANOVA, p < 0.001). All eight experimental means (MPa) were compared by the Tukey's test (p < 0.05) and the following results were obtained: Tyrian-One Step Plus /C&B/24 h (22.4 +/- 7.3); Tyrian-One Step Plus /Variolink II/24 h (39.4 +/- 11.6); Xeno III/C&B/24 h (40.3 +/- 12.9); Xeno III/Variolink II/24 h (25.8 +/- 10.5); Tyrian-One Step Plus / C&B/90 d (22.1 +/- 12.8) Tyrian-One Step Plus/VariolinkII/90 d (24.2 +/- 14.2); Xeno III/C&B/90 d (27.0 +/- 13.5); Xeno III/Variolink II/90 d (33.0 +/- 8.9). Conclusions: Xeno III/Variolink II was the luting agent/adhesive combination that provided the most promising bond strength after 90 days of storage in water.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this paper is to compare the fluoride-releasing and mechanical properties of an experimental luting glass ionomer cement, which has a modified composition and a commercial luting cement. The experimental powder was obtained by sol-gel process and then, it was used to prepare the experimental cements. The properties of cement pastes, such as setting time and working time, microhardness and diametral tensile strength were determined. Fluoride release from GICs was evaluated at time intervals of 1, 7, 14, 21 and 28 days in deionized water. Atomic force microscopy (AFM) analyses showed that the surface of the experimental cements is more homogeneous than commercial GICs. The mechanical properties and the measure of liberation of fluoride of the two cements were influenced by ratio powder:liquid and chemical composition of the precursor powders. Experimental cements released less fluoride than commercial cements. However, this liberation was more constant during the analyzed period. Thus, the results obtained in this study indicated that the composition of the experimental powder modified by the niobium can lead the formation of the polysalt matrix with good mechanical properties. In other words, we can say that experimental powder offered considerable promise for exploitation in dental field.
Resumo:
The corrosion resistance of three of the constituent phases in high copper dental amalgams has been investigated by electrochemical methods in 0.9% NaCl solution. Polarization curves show corrosion potentials most positive for gamma(1)-Ag2Hg3, followed by Ag-Cu, and gamma-Ag3Sn in agreement with the order of corrosion resistance deduced from the corrosion currents. Complex plane impedance plots at the open circuit potential showed distorted semicircles with diffusional components at low frequency for Ag-Hg and Ag-Cu, while for gamma-Ag3Sn a layer of corrosion products is formed, partially or completely covering the surface of the electrode. Impedance and noise spectra have been compared in the frequency domain, and show good agreement. (C) 2004 Elsevier Ltd. All rights reserved.
Resumo:
Dental amalgams, formed by reaction of mercury with a powder alloy containing mainly Ag, Sn, Cu and Zn, have a complex metallurgical structure which can contain up to six phases. Their observed corrosion is thus a complex process, which involves contributions from each of the phases present as well as intergranular corrosion. It is thus of interest to investigate the corrosion of individual phases present in dental amalgams. In this work the corrosion behaviour in 0.9% NaCl solution of Ag-Hg, Ag-Sn and Sn-Hg phase components of dental amalgams was investigated by electrochemical methods. The corrosion resistance was found to decrease in the order gamma (1)-Ag2\Hg3, gamma -Ag3Sn and gamma (2)-Sn7Hg. (C) 2001 Elsevier B.V. Ltd. All rights reserved.
Resumo:
Metallographic studies by scanning electron microscopy and energy dispersive spectroscopy carried out for two types of dental amalgam showing a porous multiphase material. Surface analysis shows that the structure of the Dispersalloy amalgam consists of gamma-Ag3Sn, gamma(1)-Ag2Hg3, eta'-Cu6Sn5, epsilon-Cu3Sn and eutectic Ag-Cu phases. while Velvalloy amalgam consists mainly of gamma, gamma(1) and gamma(2)-Sn7-8Hg phases. The latter phase presents an uniform distribution often associated with voids.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
OBJECTIVE: This prospective clinical study was conducted with the purpose of evaluating the influence of the banded Herbst appliance on dental changes during the early treatment of Class II malocclusion. METHOD: The sample consisted of 15 prepubertal subjects (12 boys and 3 girls, initial age: 9 years and 6 months) who were treated with the Herbst appliance. Treatment effects were compared with those of a Class II Division 1 group of 15 subjects (8 boys and 7 girls, mean initial age 9 years and 1 month), not treated orthodontically. Statistical analysis was performed using Student t-test with 5% significance level. RESULTS: The results showed that treatment with the banded Herbst appliance in the mixed dentition stage tended to upright maxillary incisors (mean: 4.14°). The maxillary molars were distalized and intruded significantly (mean 2.65 mm and 1.24 mm, respectively), the lower incisors slightly protruded anteriorly (mean 1.64 mm) and the molars showed no significant changes in the horizontal and vertical directions. Furthermore, significant improvements were noted in overbite (1.26 mm), overjet (4.8 mm) and molar relationship (12.08 mm). CONCLUSIONS: Changes in the upper dental arch were found to be greater than changes in the lower arch. Furthermore, mandibular anchorage loss was reduced due to the anchorage system used in the study.
Resumo:
Fez-se o acompanhamento radiográfico mensal da erupção dental de cinco fêmeas e sete machos da espécie Agouti paca durante 30 meses. Os animais foram radiografados mês-a-mês. As pacas nasceram com três dentes em cada hemiarcada dental, um incisivo de crescimento contínuo por toda a vida, um pré-molar decíduo (o único que é decíduo) e um molar. No quarto mês houve a erupção do segundo molar. O nivelamento da superfície de oclusão dos dentes inferiores ocorreu no sexto mês e o dos superiores ao redor do nono mês. No 14° mês, houve o início da erupção do terceiro molar e, no 16° mês, a evidenciação radiográfica do pré-molar permanente, ainda com preservação de correspondente decíduo. No 21° mês, ocorreu o nivelamento da superfície de oclusão dos quatro dentes superiores e inferiores. Entre o 22° e o 24° mês, iniciou-se a queda dos pré-molares decíduos inferiores e, entre o 23º e o 24° mês, a dos superiores. Entre o 24º e o 25º mês, a superfície de oclusão dos dentes inferiores estava nivelada, e a dos dentes superiores aconteceu no 27º mês.
Resumo:
Este estudo foi realizado objetivando estudar o efeito das práticas de alimentação infantil e de fatores associados sobre a ocorrência de cárie dental. Para isso, determinou-se o ceo-d e o ceo-s em 156 crianças de 18 a 48 meses e foi aplicado às mães um questionário incluindo perguntas sobre a ocupação do pai, nível educacional da mãe, higiene bucal, época de erupção do dente e sobre práticas de alimentação infantil. Os dados obtidos foram analisados através dos testes X2 e Mann-Whitney U. A média do ceo-s foi 3,4 com 40% das crianças livres de cáries, sendo que 36 e 24% tinham um ceo-d maior que 0 e 4, respectivamente. Notou-se que 72% das crianças eram alimentadas ao seio, 17% apenas com mamadeira e 10% pelos dois meios. Das crianças alimentadas apenas com mamadeira 70% apresentaram cárie. A cárie de mamadeira foi observada em 20% das crianças, sendo que 77% destas tinham sido alimentadas por mais de 12 meses. As crianças, cujos pais eram profissionais com terceiro grau de escolaridade, tiveram significativamente menos cárie do que aquelas de pais com nível técnico ou pais operários. A prevalência de cárie na faixa etária estudada foi relativamente alta. As crianças com cárie de mamadeira tenderam a manter seus hábitos de aleitamento por mais de 12 meses, sendo que o uso de mamadeira açucarada estava presente em 100% dos casos.