980 resultados para degradation gradient


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of population models able to reproduce the dynamics of zooplankton is a central issue when trying to understand how a changing environment would affect zooplankton in the future. Using 10 years of monthly data on phytoplankton and zooplankton abundance in the Bay of Biscay from the IEO's RADIALES time-series programme, we built non-parametric Generalized Additive Models (GAMs) able to reproduce the dynamics of plankton on the basis of environmental factors (nutrients, temperature, upwelling and photoperiod). We found that the interaction between these two plankton components is approximately linear, whereas the effects of environmental factors are non-linear. With the inclusion of the environmental variability, the main seasonal and inter-annual dynamic patterns observed within the studied plankton assemblage indicate the prevalence of bottom-up regulatory control. The statistically deduced models were used to simulate the dynamics of the phytoplankton and zooplankton. A good agreement between observations and simulations was obtained, especially for zooplankton. We are presently developing spatio-temporal GAM models for the North Sea based on the Continuous Plankton Recorder database.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Se estudia la influencia de los siguientes factores sobre el valor del cociente de feofitinización DO 435 nm/DO 415 nm en el líquen Anaptychia ciliaris (L.) Kórber: edad del líquen, concentración final de pigmentos, trasplante de los líquenes a áreas distintas sobre sustratos diferentes o similares y el valor de pH del sustrato original o el adoptado tras el trasplante. Se discute la utilización de A. ciliaris como un bioindicador de la presencia de factorcs acidificantes en la atmósfera o en el agua de lluvia que provoquen la feofitinización de las clorofilas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poly-L-Lactide is a bioresorbable polymer which degrades through hydrolysis of its ester linkage influenced by initial molecular weight and degree of crystallinity. Polymers belonging to the aliphatic polyester family currently represent the most attractive group of polymers that meet the medical and physical demands for safe clinical applications. Compression moulded PLLA pellets were produced as rods, sterilized and degraded both in vitro and in vivo (sub-dermal implantation model). The material molecular weight, crystallinity, mechanical strength and thermal properties were evaluated. In both in vitro and in vivo environments, degradation proceeded at the same rate and followed the general sequence of aliphatic polyester degradation, ruling out enzymes accelerating the degradation rate in vivo. By 44 weeks duration of implantation the PLLA rods were still biocompatible, before any mass loss was observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poly-L-lactide (PLLA) is one of the most significant members of a group of polymers regarded as bioresorbable. The degradation of PLLA proceeds through hydrolysis of the ester linkages in the polymer's backbone; however, the time for the complete resorption of orthopaedic devices manufactured from PLLA is known to be in excess of five years in a normal physiological environment. To evaluate the degradation of PLLA in an accelerated time period, PLLA pellets were processed by compression moulding into tensile test specimens, prior to being sterilized by ethylene oxide gas (EtO) and degraded in a phosphate-buffered solution (PBS) at both 50°C and 70°C. On retrieval, at predetermined time intervals, procedures were used to evaluate the material's molecular weight, crystallinity, mechanical strength, and thermal properties. The results from this study suggest that at both 50°C and 70°C, degradation proceeds by a very similar mechanism to that observed at 37°C in vitro and in vivo. The degradation models developed also confirmed the dependence of mass loss, melting temperature, and glass transition temperature (Tg) on the polymer's molecular weight throughout degradation. Although increased temperature appears to be a suitable method for accelerating the degradation of PLLA, relative to its physiological degradation rate, concerns still remain over the validity of testing above the polymer's Tg and the significance of autocatalysis at increased temperatures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ageing behaviour of ultra-high molecular weight polyethylene (UHMWPE) has been studied following gamma irradiation (25 or 40 kGy) in air. Accelerated ageing procedures used elevated temperature (70°C) and/or pressurised oxygen (5 bar). Shelf-aged UHMWPE was also studied. The variation in surface density and mechanical properties were determined following the various sterilisation and ageing treatments. Microabrasive wear testing was also performed. Wear rates were found to correlate well with stress at break for sterilised and aged UHMWPE but not with elongation to failure. It is proposed that the wear mechanism is fracture dominated and occurs following some disentanglement of the polymer chains. Wear also depends upon embrittlement of the surface layer due to its processing and ageing. Elongation to failure in a tensile test is not a good measure of this embrittlement whereas the microabrasion test provides more surface sensitive information concerning this property.