975 resultados para constant rate infusion
Resumo:
The Schwinger proper-time method is an effective calculation method, explicitly gauge-invariant and nonperturbative. We make use of this method to investigate the radiatively induced Lorentz- and CPT-violating effects in quantum electrodynamics when an axial-vector interaction term is introduced in the fermionic sector. The induced Lorentz- and CPT-violating Chern-Simons term coincides with the one obtained using a covariant derivative expansion but differs from the result usually obtained in other regularization schemes. A possible ambiguity in the approach is also discussed. (C) 2001 Published by Elsevier Science B.V.
Resumo:
A navegação aérea, enquanto atividade regulada, está sujeita a legislação específica, dependendo o seu exercício de autorização própria atribuída por uma entidade supervisora, que também verifica as tarifas a aplicar. O regulamento (CE) N.º 550/2004 identifica os requisitos comuns para a prestação de serviços de navegação aérea na Europa, dando particular importância à transparência do relato financeiro ao exigir a sua elaboração segundo as normas internacionais de contabilidade e a verificação por uma auditoria independente. Adicionalmente, o Regulamento (EU) N.º 1191/2010, que alterou o Regulamento (CE) N.º 1794/2006, estabelece o regime comum de tarifação de tais serviços, nomeadamente a recuperabilidade de desvios relativos ao volume de tráfego e aos gastos controláveis e não controláveis. Ao nível do enquadramento contabilístico, as atividades reguladas não têm uma norma específica. Existem dois projetos do IASB – um de 2009, que foi suspenso, e um de 2013, relativo à implementação de uma norma transitória que incentive a adoção das normas internacionais por entidades que exerçam atividades reguladas. Existe, ainda, uma norma do FASB não aplicável no espaço europeu. Os R&C de várias entidades evidenciam a existência de diferentes referenciais contabilísticos e que a generalidade dos relatórios de auditoria não tem reservas ou ênfases. Enquanto algumas entidades apenas divulgam os montantes dos desvios, outras entidades consideram que tais montantes se qualificam, reconhecendo-os. Tal facto decorre da inexistência de uma norma internacional que põe em causa a comparabilidade da informação financeira e dificulta o julgamento do auditor quanto à adequação ou não dos procedimentos adotados pela entidade.
Resumo:
Airflow rate is one of the most important parameters for the soil vapor extraction of contaminated sites, due to its direct influence on the mass transfer occurring during the remediation process. This work reports the study of airflow rate influence on soil vapor extractions, performed in sandy soils contaminated with benzene, toluene, ethylbenzene, xylene, trichloroethylene and perchloroethylene. The objectives were: (i) to analyze the influence of airflow rate on the process; (ii) to develop a methodology to predict the remediation time and the remediation efficiency; and (iii) to select the most efficient airflow rate. For dry sandy soils with negligible contents of clay and natural organic matter, containing the contaminants previously cited, it was concluded that: (i) if equilibrium between the pollutants and the different phases present in the soil matrix was reached and if slow diffusion effects did not occur, higher airflow rates exhibited the fastest remediations, (ii) it was possible to predict the remediation time and the efficiency of remediation with errors below 14%; and (iii) the most efficient remediation were reached with airflow rates below 1.2 cm3 s 1 standard temperature and pressure conditions.
Resumo:
A flow-spectrophotometric method is proposed for the routine determination of tartaric acid in wines. The reaction between tartaric acid and vanadate in acetic media is carried out in flowing conditions and the subsequent colored complex is monitored at 475 nm. The stability of the complex and the corresponding formation constant are presented. The effect of wavelength and pH was evaluated by batch experiments. The selected conditions were transposed to a flowinjection analytical system. Optimization of several flow parameters such as reactor lengths, flow-rate and injection volume was carried out. Using optimized conditions, a linear behavior was observed up to 1000 µg mL-1 tartaric acid, with a molar extinction coefficient of 450 L mg-1 cm-1 and ± 1 % repeatability. Sample throughput was 25 samples per hour. The flow-spectrophotometric method was satisfactorily applied to the quantification of tartaric acid (TA) in wines from different sources. Its accuracy was confirmed by statistical comparison to the conventional Rebelein procedure and to a certified analytical method carried out in a routine laboratory.
Resumo:
Abstract This work reports the analysis of the efficiency and time of soil remediation using vapour extraction as well as provides comparison of results using both, prepared and real soils. The main objectives were: (i) to analyse the efficiency and time of remediation according to the water and natural organic matter content of the soil; and (ii) to assess if a previous study, performed using prepared soils, could help to preview the process viability in real conditions. For sandy soils with negligible clay content, artificially contaminated with cyclohexane before vapour extraction, it was concluded that (i) the increase of soil water content and mainly of natural organic matter content influenced negatively the remediation process, making it less efficient, more time consuming, and consequently more expensive; and (ii) a previous study using prepared soils of similar characteristics has proven helpful for previewing the process viability in real conditions.
Resumo:
Zero valent iron (ZVI) has been extensively used as a reactive medium for the reduction of Cr(VI) to Cr(III) in reactive permeable barriers. The kinetic rate depends strongly on the superficial oxidation of the iron particles used and the preliminary washing of ZVI increases the rate. The reaction has been primarily modelled using a pseudo-first-order kinetics which is inappropriate for a heterogeneous reaction. We assumed a shrinking particle type model where the kinetic rate is proportional to the available iron surface area, to the initial volume of solution and to the chromium concentration raised to a power ˛ which is the order of the chemical reaction occurring at surface. We assumed α= 2/3 based on the likeness to the shrinking particle models with spherical symmetry. Kinetics studies were performed in order to evaluate the suitability of this approach. The influence of the following parameters was experimentally studied: initial available surface area, chromium concentration, temperature and pH. The assumed order for the reaction was confirmed. In addition, the rate constant was calculated from data obtained in different operating conditions. Digital pictures of iron balls were periodically taken and the image treatment allowed for establishing the time evolution of their size distribution.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização de Estruturas
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Química
The utilization bound of non-preemptive rate-monotonic scheduling in controller area networks is 25%
Resumo:
Consider a distributed computer system comprising many computer nodes, each interconnected with a controller area network (CAN) bus. We prove that if priorities to message streams are assigned using rate-monotonic (RM) and if the requested capacity of the CAN bus does not exceed 25% then all deadlines are met.
Resumo:
Temporal isolation is an increasingly relevant con- cern in particular for ARINC-351 and virtualisation- based systems. Traditional approaches like the rate- based scheduling framework RBED do not take into account the impact of preemptions in terms of loss of working set in the acceleration hardware (e.g. caches). While some improvements have been suggested in the literature, they are overly heavy in the presence of small high-priority tasks such as interrupt service routines. Within this paper we propose an approach enabling adaptive assessment of this preemption delay in a tem- poral isolation framework with special consideration of capabilities and limitations of the approach.
Resumo:
The self similar branching arrangement of the airways makes the respiratory system an ideal candidate for the application of fractional calculus theory. The fractal geometry is typically characterized by a recurrent structure. This study investigates the identification of a model for the respiratory tree by means of its electrical equivalent based on intrinsic morphology. Measurements were obtained from seven volunteers, in terms of their respiratory impedance by means of its complex representation for frequencies below 5 Hz. A parametric modeling is then applied to the complex valued data points. Since at low-frequency range the inertance is negligible, each airway branch is modeled by using gamma cell resistance and capacitance, the latter having a fractional-order constant phase element (CPE), which is identified from measurements. In addition, the complex impedance is also approximated by means of a model consisting of a lumped series resistance and a lumped fractional-order capacitance. The results reveal that both models characterize the data well, whereas the averaged CPE values are supraunitary and subunitary for the ladder network and the lumped model, respectively.
Resumo:
Si3N4 tools were coated with a thin diamond film using a Hot-Filament Chemical Vapour Deposition (HFCVD) reactor, in order to machining a grey cast iron. Wear behaviour of these tools in high speed machining was the main subject of this work. Turning tests were performed with a combination of cutting speeds of 500, 700 and 900 m min−1, and feed rates of 0.1, 0.25 and 0.4 mm rot−1, remaining constant the depth of cut of 1 mm. In order to evaluate the tool behaviour during the turning tests, cutting forces were analyzed being verified a significant increase with feed rate. Diamond film removal occurred for the most severe set of cutting parameters. It was also observed the adhesion of iron and manganese from the workpiece to the tool. Tests were performed on a CNC lathe provided with a 3-axis dynamometer. Results were collected and registered by homemade software. Tool wear analysis was achieved by a Scanning Electron Microscope (SEM) provided with an X-ray Energy Dispersive Spectroscopy (EDS) system. Surface analysis was performed by a profilometer.
Resumo:
OBJECTIVE To analyze the effects of acupressure at the SP6 point on labor duration and cesarean section rates in parturients served in a public maternity hospital.METHODS This controlled, randomized, double-blind, pragmatic clinical trial involved 156 participants with gestational age ≥ 37 weeks, cervical dilation ≥ 4 cm, and ≥ 2 contractions in 10 min. The women were randomly divided into an acupressure, placebo, or control group at a university hospital in an inland city in the state of Sao Paulo, Brazil, in 2013. Acupressure was applied to the SP6 point during contractions for 20 min.RESULTS The average labor duration was significantly different between the SP6 acupressure group [221.5 min (SD = 162.4)] versus placebo [397.9 min (SD = 265.6)] and versus control [381.9 min (SD = 358.3)] (p = 0.0047); however, the groups were similar regarding the cesarean section rates (p = 0.2526) and Apgar scores in the first minute (p = 0.9542) and the fifth minute (p = 0.7218) of life of the neonate.CONCLUSIONS The SP6 acupressure point proved to be a complementary measure to induce labor and may shorten the labor duration without causing adverse effects to the mother or the newborn. However, it did not affect the cesarean section rate.
Resumo:
This paper describes the hardware implementation of a High-Rate MIMO Receiver in an FPGA for three modulations, namely BPSK, QPSK and 16-QAM based on the Alamouti scheme. The implementation with 16-QAM achieves more than 1.6 Gbps with 66% of the resources of a medium-sized Virtex-4 FPGA. This results indicate that the Alamouti scheme is a good design option for hardware implementation of a high-rate MIMO receiver. Also, using an FPGA, the modulation can be dynamically changed on demand.
Resumo:
ABSTRACT OBJECTIVE To describe the response rate and characteristics of people who either took part or not in from the Study of Cardiovascular Risks in Adolescents (ERICA) , according to information subsets. METHODS ERICA is a school-based, nation-wide investigation with a representative sample of 12 to 17-year-old adolescents attending public or private schools in municipalities with over 100,000 inhabitants in Brazil. Response rate of eligible subjects were calculated according to macro-regions, sex, age, and type of school (public or private). We also calculated the percentages of replacement schools in comparison with the ones originally selected as per the sample design, according to the types of schools in the macro-regions. The subjects and non-subjects were compared according to sex, age, and average body mass indices (kg/m2). RESULTS We had 102,327 eligible adolescents enrolled in the groups drawn. The highest percentage of complete information was obtained for the subset of the questionnaire (72.9%). Complete information regarding anthropometric measurements and the ones from the questionnaire were obtained for 72.0% of the adolescents, and the combination of these data with the 24-hour dietary recall were obtained for 70.3% of the adolescents. Complete information from the questionnaire plus biochemical blood evaluation data were obtained for 52.5% of the morning session adolescents (selected for blood tests). The response percentage in private schools was higher than the one in public schools for most of the combination of information. The ratio of older and male adolescents non-participants was higher than the ratio among participants. CONCLUSIONS The response rate for non-invasive procedures was high. The response rate for blood collection – an invasive procedure that requires a 12-hour fasting period and the informed consent form from legal guardians – was lower. The response rate observed in public schools was lower than in the private ones, and that may reflect lower school frequency of registered students.