947 resultados para caries depth


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mandibles of two cats containing carious lesions were discovered among the previously published findings of feline dental resorptive lesions from materials examined at an archaeological museum. These lesions were too small to be noted on radiographs, and consisted of two inconspicuous enamel lesions in a mandibular left first molar tooth (309), a clinically visible white spot area containing an enamel lesion in a mandibular left fourth premolar tooth (308), and a root surface caries in the 308 of a different specimen. Histologic examination using special stains and polarized light revealed both initial and early initial stage enamel caries, as well as root surface caries. Knoop hardness measurements confirmed these findings, considered the first documented cases of feline caries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to test whether the status of the adjacent tooth surface has an influence on the signal of a new laser fluorescence (LF) device for the detection of approximal caries. Seventy-eight teeth were selected from a pool of extracted permanent human molars, frozen at -20 degrees C until use. Before being measured the teeth were defrosted, cleaned, and any calculus removed. As a control, a defined approximal surface of each tooth was measured with the LF device holding the tip with the detecting- and the reverse-side on it, but without a neighboring tooth contacting the surface. The proximal site under examination was then placed adjacent to a tooth, which had deep dentinal caries, a composite restoration, a provisional ZnO-Eugenol restoration, or a ceramic restoration. The adjacent tooth with the ZnO-Eugenol restoration, the composite restoration, and the dentinal caries all demonstrated a statistically significant increase of LF readings on sound tooth surfaces. Teeth with enamel or dentinal caries were only slightly (and not statistically significantly) influenced by the different types of neighboring surfaces compared with the control LF readings. It can be concluded that caries detection of approximal tooth surfaces with the new LF system might be influenced by the condition of the adjacent tooth surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Research suggests that mutans streptococci play an important role in cariogenesis in children but the usefulness of bacterial testing in risk assessment is unknown. Our objective was to summarize the literature assessing the association of mutans streptococci and dental caries in preschool children, (Pre)Medline (1966-2003), Embase (1980-2003), the Cochrane Register of Controlled Trials (2003, issue 3), and reference lists of included studies were searched. All abstracts found by the electronic searches (n = 981) were independently scrutinized by 2 reviewers. Minimal requirements for inclusion were assessment of preschool children without caries at baseline, reporting of mutans streptococci present in saliva or plaque at baseline and assessment of caries presence after a minimum of 6 months of follow-up. Participants' details, test methods, methodological characteristics and findings were extracted by one reviewer and cross-checked by another. Homogeneity was tested using chi2 tests. Results of plaque and saliva testing were pooled separately using a fixed effects model. Methodological quality of reports was low. Out of 9 studies included, data from 3 reports on plaque test assessment alone (n = 300) and from 4 reports on saliva test assessment alone (n = 451) were available for pooled analysis. The pooled risk ratio (95% CI) was 3.85 (2.48-5.96) in studies using plaque tests and 2.11 (1.47-3.02) in those using saliva testing. Presence of mutans streptococci, both in plaque or saliva of young caries-free children, appears to be associated with a considerable increase in caries risk. Lack of adjustment for potential confounders in the original studies, however, limits the extent to which interpretations for practice can be made.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this study was to evaluate the cavitation rate of proximal caries using different magnification aids in vitro. METHODS: Radiographs of 285 extracted teeth were taken and the proximal surfaces were graded to the criteria R0 (no radiolucency), R1 (radiolucency confined to the outer half of enamel), R2 (inner half of enamel) and R3 (outer half of dentin). Subsequently, the proximal surfaces were checked for the presence of cavitations with the naked eye (NE), and by using 4.3 x magnification eyeglasses (ME), a stereo microscope (SM, 10x), or a scanning electron microscope (SEM, up to 2000 x magnification). RESULTS: In surfaces with R3 caries, cavitations were visible in 56 of 59 cases with the naked eye. When using SEM, all surfaces revealed cavitations (100%). Regarding the surfaces with R2 lesion, 36 of 46 cases showed cavitations (NE); the corresponding values were 39/46 (ME), 41/46 (SM), and 46/46 (SEM); in the latter, in most cases deep defects could be observed. With regard to R1 lesions, 36/60 (NE), 43/60 (ME), 45/60 (SM), and 58/60 (SEM) cases revealed cavitations. A breakdown of radiographically sound surfaces (R0) was present in some 10% of the examined surfaces (24/261, NE; 33/261, SEM). CONCLUSIONS: Cavitations (defined as breakdown of the surface) are present in significantly more cases than previously reported. This might be an explanation why even small radiolucencies tend to progress, albeit slowly. Thus, close follow-ups should strongly be recommended when considering a preventive treatment regimen with small radiolucencies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The laser device DIAGNOdent developed for the detection of occlusal caries has limited value on approximal surfaces. The aim of this study was to develop and to test a new laser fluorescence (LF) device for the detection of approximal caries. Light with a wavelength of 655 nm was transported to the approximal surface using two different sapphire fibre tips. Seventy-five teeth were selected from a pool of extracted permanent human molars, frozen at -20 degrees C until use. Before being measured, they were defrosted, cleaned and calculus was removed with a scaler. The molars were set in blocks simulating the contact area of adults. Bitewing radiographs were obtained using Kodak Insight films. After two independent assessments with the new LF device, the teeth were histologically prepared, and assessed for caries extension. Using the laser, specificity values for D1 threshold (outer half of enamel), D2 threshold (inner half of enamel), D3 threshold (dentine) ranged between 0.81 and 0.93, sensitivity between 0.84 and 0.92 with no difference between the two tips. Bitewing radiography showed an inferior performance compared to LF (p<0.05). Intraex aminer reproducibility was high (kappa>.74). The new LF system might be a useful additional tool in detecting approximal caries. Because of its good reproducibility, it could be used to monitor caries regression or progression on approximal surfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The new device DIAGNOdent pen based on red laser light induced fluorescence was introduced for the detection of approximal and occlusal caries. The aim of this study was to test its performance on occlusal surfaces. The new device comes with two different sapphire fibre tips: a cylindrical tip and a conical tip. The two new sapphire fibre tips were used and compared with the tip currently available with DIAGNOdent (DD). METHODS: The teeth were selected from a pool of extracted permanent human molars, which were stored frozen at -20 degrees C, until use. Prior to being measured the teeth were defrosted and cleaned. One hundred and nineteen teeth were selected and measured with the old tip and with the two new tips of the new device by two independent assessments. The teeth were histologically prepared and assessed for caries extension. RESULTS: Specificity values for D(1), D(2) and D(3) ranged between 0.69 and 0.89, sensitivity between 0.78 and 0.96. There were no statistically significant differences obtained between the two tips of the new and the one tip of the old device (p>0.05). Intra-examiner reliability with kappa values of >0.83 was high. CONCLUSIONS: In this study, the new laser fluorescence device performed on occlusal surfaces as well as the available device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Periodontitis and caries are common diseases in older adults. Aims: To test if rinsing with chlorhexidine over five years has an impact on the subgingival microbiota. Methods: In a double blind randomized five years chlorhexidine rinse study clinical oral data and subgingival plaque samples were analyzed by the checkerboard DNA-DNA hybridization method. Results: At year 5 subject mean age was 71.2 years (S.D. + 4.1) (56.2% women). Only in subjects with no bone loss did the chlorhexidine rinse group subjects presented with lower total bacterial (DNA) counts (mean diff: 63.1 (x105), S.E diff + 30.1 (x105), 95%CI: 0.8 to 120.5 (x105), p<0.05) [(i.e.Lactobacillus acidophilicus (p<0.05) , Streptococcus oralis (p<0.05), Eikenella. corrodens (p< 0.05), C. gracilis (p<0.01), F.nucl.sp. nucleatum (p< 0.02), Fusobacterium nucl. sp. polymorphum (p<0.02), Neisseria mucosa (p<0.02), Leptothrichia buccalis (p<0.02), and Selenomonas noxia (p<0.050)]. Higher bacterial loads were found for the green (p<0.05), yellow (streptococci spp) (p<0.01), and the ‘other' complexes (p<0.01). Conclusions: Independent of probing pocket depth, older subjects carry a large variety of bacteria associated with periodontitis. The oral microbiota in older subjects is linked to alveolar bone loss and not to probing depth. Chlorhexidine may provide a benefit in preventing periodontitis in older persons.