757 resultados para brand values
Resumo:
The pH values near a planar dissociating membrane are studied under a mean field approximation using the Poisson-Boltzmann equation and its linear form. The equations are solved in planar symmetry with the consideration that the charge density on the dissociating membrane surface results from an equilibrium process with the neighboring electrolyte. Results for the membrane dissociation degree are presented as a function of the electrolyte ionic strength and membrane surface charge density. Our calculations indicate that pH values have an appreciable variation within 2 nm from the membrane. It is shown that the dissociation process is enhanced due to the presence of bivalent ions and that pH values acquire better stability than in an electrolyte containing univalent ions.
Resumo:
An experiment was carried out to determine the chemical composition, metabolizable energy values, and coefficients of nutrient digestibility of corn germ meal for layers. The chemical composition of corn germ meal was determined, and then a metabolism assay was performed to determine its apparent metabolizable energy (AME) and apparent metabolizable energy corrected for nitrogen (AMEn) values and its dry matter and gross energy apparent metabolizability coefficients (CAMDM and CAMGE, respectively). In the 8-day assay (four days of adaptation and four days of total excreta collection), 60 29-week-old white Lohman LSL layers were used. A completely randomized experimental design, with three treatments with five replicates of four birds each, was applied. Treatments consisted of a reference diet and two test diets, containing 20 or 30% corn germ meal. Results were submitted to analysis of variance and means were compared by the Tukey tests at 5% probability level. The chemical composition of corn germ meal was: 96.39% dry matter, 49.48% ether extract, 1.87% ashes, 7243 kcal gross energy/kg, 11.48% protein, 0.19% methionine, 0.21% cystine, 0.48% lysine, 0.40% threonine, 0.72% arginine, 0.35% isoleucine, 0.83% leucine, 0.57% valine, and 0.37% histidine, on as-fed basis. There were no statistical differences in AME, AMEn, CAMDM, and CAMGE values with the inclusion of 20 and 30% corn germ meal in the diets. On dry matter basis, AME, AMEn, CAMDM, and CAMGE values of corn germ meal were: 4,578 and 4,548 kcal/kg, 4,723 and 4,372 kcal/kg, 64.95 and 61.86%, respectively.
Resumo:
OBJECTIVE: To verify if the reference values of Sleep Apnea cephalometric analysis of North American individuals are similar to the ones of Brazilian individuals presenting no craniofacial anomalies. The study also aimed to identify craniofacial alterations in Obstructive Sleep Apnea-Hypopnea Syndrome (OSAHS) patients in relation to individuals without clinical characteristics of the disease through this cephalometric analysis. METHOD: It were used 55 lateral cephalograms consisting of 29 for the control group of adult individuals without clinical characteristics of OSAHS and 26 apneic adults. All radiographs were submitted to Sleep Apnea cephalometric analysis through Radiocef Studio 2.0. The standard values of this analysis were compared, by means of z test, to the ones obtained from the control group and these were compared to values from apneic group through Student's t test. RESULTS: There were no significant differences between values obtained from control group and standard values. On the group of OSAHS patients it was observed a decrease on the dimensions of upper airways and an increase on the soft palate length. CONCLUSIONS: The standard values of Sleep Apnea analysis can be used as reference in Brazilian individuals. Besides, through lateral cephalograms it was possible to identify craniofacial alterations in OSAHS patients.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Knowledge of the effectiveness of prostaglandins in uterine involution process led to the development of protocols with its analogues in postpartum period. However, this hormone mechanism of action is not yet fully elucidated. Thus, the objective of this study was to verify if chloprostenol administration, at early or intermediary puerperium, can induce changes on progesterone, PGFM and oestradiol plasma concentrations. 30 Murrah postpartum buffaloes were randomly divided into three groups: CONT (saline, n = 10); CLO2 (chloprostenol at days 2 and 5 postpartum, n = 10) and; CLO15 (chloprostenol at days 15 and 20 postpartum, n = 10). Blood samples were collected from jugular vein to measure progesterone, PGFM and oestradiol plasma concentrations at days 2, 7, 14, 21 and 28 postpartum. CLO2 group presented lower progesterone and PGFM plasma concentrations in relation to CONT and CLO15 groups (0.23 +/- 0.00 and 0.32 +/- 0.11, 0.19 +/- 0.00 and 0.23 +/- 0.11, 0.23 +/- 0.00 and 0.30 +/- 0.19, for groups CONT, CLO2 and CLO15, respectively; P < 0.05). There was no significant difference in oestradiol plasma concentration between experimental groups (P > 0.05). Prostaglandin synthetic analogue administration induced hormonal changes in postpartum buffaloes, which can partially explain its positive effect under reproductive function of this specie.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Atualmente o titânio é empregado como biomaterial devido à sua biocompatibilidade e resistência à corrosão. Entretanto, íons fluoretos, freqüentemente empregados em dentifrícios bucais, podem interferir no processo de corrosão. O objetivo deste estudo foi analisar a influência de um meio fluoretado com diferentes pH nas propriedades mecânicas e na resistência à corrosão dos conjuntos implantes/componentes protéticos à base de Ti c.p., a partir dos testes de fadiga, microscopia eletrônica de varredura (MEV) e dureza. Foram simulados cinco anos de uso regular de meios de higiene oral com conteúdo de 1500 ppm de NaF, com dois diferentes pH, 7,4 e 5,3, mediante imersão das amostras nesses meios durante 184 horas e também em água destilada, grupo controle. As amostras foram testadas num durômetro Micromet 2001 (500gf/30s). Os dados dos testes de dureza foram analisados pelo teste de Wilcoxon, demonstrando que as amostras sofreram influência negativa na dureza após a ação dos íons fluoreto. Entretanto, essa influência não ocorreu nos testes de fadiga realizados em uma máquina de ensaios mecânicos MTS-810, fixada a 100.000 ciclos, 15Hz e programada com força de fadiga a 150 N. Pela análise de MEV foram constatadas evidências de corrosão na superfície das amostras após ação de íons fluoretos, entretanto pelo EDS não se verificou incorporação de íons fluoretos sobre a superfície dos conjuntos. Concluiu-se que a concentração de flúor e o pH das soluções não exerceram influência nas propriedades mecânicas.
Resumo:
Given the importance of Guzera breeding programs for milk production in the tropics, the objective of this study was to compare alternative random regression models for estimation of genetic parameters and prediction of breeding values. Test-day milk yields records (TDR) were collected monthly, in a maximum of 10 measurements. The database included 20,524 records of first lactation from 2816 Guzera cows. TDR data were analyzed by random regression models (RRM) considering additive genetic, permanent environmental and residual effects as random and the effects of contemporary group (CG), calving age as a covariate (linear and quadratic effects) and mean lactation curve as fixed. The genetic additive and permanent environmental effects were modeled by RRM using Wilmink, All and Schaeffer and cubic B-spline functions as well as Legendre polynomials. Residual variances were considered as heterogeneous classes, grouped differently according to the model used. Multi-trait analysis using finite-dimensional models (FDM) for testday milk records (TDR) and a single-trait model for 305-days milk yields (default) using the restricted maximum likelihood method were also carried out as further comparisons. Through the statistical criteria adopted, the best RRM was the one that used the cubic B-spline function with five random regression coefficients for the genetic additive and permanent environmental effects. However, the models using the Ali and Schaeffer function or Legendre polynomials with second and fifth order for, respectively, the additive genetic and permanent environmental effects can be adopted, as little variation was observed in the genetic parameter estimates compared to those estimated by models using the B-spline function. Therefore, due to the lower complexity in the (co)variance estimations, the model using Legendre polynomials represented the best option for the genetic evaluation of the Guzera lactation records. An increase of 3.6% in the accuracy of the estimated breeding values was verified when using RRM. The ranks of animals were very close whatever the RRM for the data set used to predict breeding values. Considering P305, results indicated only small to medium difference in the animals' ranking based on breeding values predicted by the conventional model or by RRM. Therefore, the sum of all the RRM-predicted breeding values along the lactation period (RRM305) can be used as a selection criterion for 305-day milk production. (c) 2014 Elsevier B.V. All rights reserved.
Resumo:
PurposeThe mechanical properties of acrylic resins used in intraoral prostheses may be altered by frequent exposure to liquids such as beverages and mouthwashes. This study aimed to evaluate the effect of thermocycling and liquid immersion on the hardness of four brands of acrylic resins commonly used in removable prostheses (Onda Cryl, QC-20, Classico, Lucitone).Materials and MethodsFor each brand of resin, seven specimens were immersed in each of six solutions (coffee, cola, red wine, Plax-Colgate, Listerine [LI], Oral B), and seven more were placed in artificial saliva (control). The hardness was tested using a microhardness tester before and after 5000 thermocycles and after 1, 3, 24, 48, and 96 hours of immersion. The results were analyzed using three-way repeated-measures ANOVA and Tukey's test (p < 0.05).ResultsThe hardness of the resins decreased following thermocycling and immersion in the solutions. Specimens immersed in cola and wine exhibited significant decreases in hardness after immersion for 96 hours, although the greatest significant decrease in hardness occurred in specimens immersed in LI. However, according to American Dental Association specification 12, the Knoop hardness of acrylic resins for intraoral prostheses should not be below 15. Thus, the median values of superficial hardness observed in most of the acrylic resins in this study are considered clinically acceptable.ConclusionsThe microhardness of polymers used for intraoral prostheses decreases following thermocycling. Among specimens immersed in beverages, those immersed in cola or wine experienced the greatest decrease in microhardness. Immersion of acrylic resins in LI significantly decreased the microhardness in relation to the initial value. Among the resins assessed, QC-20 exhibited the lowest initial hardness.
Resumo:
Muscle fatigue is described as a cause of injuries among the many related to the running practice. Therefore, the purpose of this study was to analyze the behavior of the amplitude (RMS) and median frequency (MF) of EMG signal of the iliocostalis (CI), rectus femoris (RF), vastus lateralis (VL), vastus medialis (VM) biceps femoris (long head) (BFCL), tibialis anterior (TA) and gastrocnemius (lateral) (LNG) from the right lower limb, and the behavior of the parameters of amplitude (AP) and frequency (PF) spent in different percentages of the maximum speed during incremental protocol of treadmill running. 10 volunteers participated in this study, athletes, male, aged between 18 and 30 years with no history of injury in lower limbs and similar anthropometry. The protocol consisted of a treadmill test with initial velocity of 10 km.h-¹ and increments of 1 km.h-¹ each three minutes until volitional exhaustion, without rest interval. Synchronized collections were made of electromyographic and kinematic data. The signals were obtained through an acquisition module of biological signals (Telemyo 900 - Noraxon - USA) and software (Myoresearch - Noraxon - USA) calibrated with a sampling frequency of 1000 Hz, gain 2000 times. The raw data were filtered with a 60Hz notch filter, high pass and low pass 20Hz to 500Hz. To capture the image was used a digital video recorder (model NV-GS320, PANASONIC brand), and for image scanning and kinematic data collection was used the software Peak Motus 9.0 (ViconPeak). To obtain the values of RMS and FM analyzed the last ten passes of each speed through a specific routine (Matlab). To obtain these variables AP (m) and FP (stride I min) were analyzed for the last ten past each speed, using specific software (Peak Motus 9.0). After verification of data normality (Shapiro-Wilk) and homogeneity of the data (Levene), the comparison ...(Complete abstract click electronic access below)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This study evaluated the effect of the addition of 5% calcium chlorite (CaCl2) on pH values in calcium hydroxide pastes (CH), with or without 2% chlorhexidine digluconate (CHX) used as vehicle, in several periods analysis. Polyethylene tubes were filled with CH mixed with water (G1), 2% CHX solution (G2) or gel (G3), or CHX solution or gel with 5% CaCl2 (G4 and G5, respectively). All tubes were individually immersed in distilled water. After 12, 24 hours, 7, 14 and 28 days, pH value was evaluated directly in water which the tubes were stored. Data were submitted to ANOVA and Tukey tests (α=0.05). In 24 hs and 14 days, pH values were similar to all groups. In 12 hs, the G1 presented lower pH value than other groups except to G4 (p < 0.05), and G4 presented lower pH value than G5 (p < 0.05). In 7 days, G1 presented lower pH value than G4 and G5 (p < 0.05). In 28 days, G1 and G5 presented lower pH values than G2 and G4 (p < 0.05) and among other groups there are no statistical differences (p > 0.05). The pH values increased in long-term analysis to all CH pastes. The association of 5% calcium chloride with 2% CHX solution as vehicle of CH paste provided a pH value increase in relation to CH mixed with distilled water. The CHX gel interfered negatively on pH value in comparison to CHX solution when mixed with CaCl2.
Resumo:
Introduction: Alkalinization potential is a fundamental property of endodontic epoxy-based cements containing calcium hydroxide. Studies have shown discrepant pH results for same materials at different evaluation periods. A possible reason accounting for these differences may be the assessment procedures. Objective: To evaluate the pH value of an epoxy-based cement (Sealer 26) in different periods of analysis, using two assessment methods. Material and methods: Sealer 26 was manipulated and immediately placed into polyethylene tubes (n=10, each group) and immersed in distilled water. In G1, the tubes were kept in the same water during all experiment; and in G2, the tubes were removed and placed into another flask with an equal amount of water after the pH evaluation. The pH of these solutions was measured at 24 hours, 7, 14 and 28 days. Analysis were made within the same group according to the experimental periods and between groups in each experimental period. Data were submitted to ANOVA (α = 5%) and t test, respectively. Results: For G1 and G2, all periods showed different pH values (p < 0.05), except between 14 and 28 days (p > 0.05) and between 7 and 14 days (p > 0.05), respectively. In each period, no significant differences were observed between the groups. Conclusion: The method to obtain the pH values in different experimental periods no interfered in the final results. However, difference was observed when the results were analyzed at same group.