909 resultados para assisted hosting
Resumo:
Total restorative proctocolectomy with ileal pouch-anal anastomosis (RP/IPAA) has become the standard of care for the surgical treatment of ulcerative colitis. Despite its correlation with an excellent quality of life and favorable long-term outcomes, RP/IPAA has been associated with several complications. Prolapse of the ileoanal pouch is a rare and debilitating complication that should be considered in the differential diagnosis of pouch failure. Limited data exist regarding the prevalence and treatment of pouch prolapse. We present the case of a recurrent J-pouch prolapse treated with a novel minimally invasive "salvage" approach involving a robotic-assisted laparoscopic rectopexy with mesh.
Resumo:
AIMS No standardized local thrombolysis regimen exists for the treatment of pulmonary embolism (PE). We retrospectively investigated efficacy and safety of fixed low-dose ultrasound-assisted catheter-directed thrombolysis (USAT) for intermediate- and high-risk PE. METHODS AND RESULTS Fifty-two patients (65 ± 14 years) of whom 14 had high-risk PE (troponin positive in all) and 38 intermediate-risk PE (troponin positive in 91%) were treated with intravenous unfractionated heparin and USAT using 10 mg of recombinant tissue plasminogen activator per device over the course of 15 h. Bilateral USAT was performed in 83% of patients. During 3-month follow-up, two [3.8%; 95% confidence interval (CI) 0.5-13%] patients died (one from cardiogenic shock and one from recurrent PE). Major non-fatal bleeding occurred in two (3.8%; 95% CI, 0.5-13%) patients: one intrathoracic bleeding after cardiopulmonary resuscitation requiring transfusion, one intrapulmonary bleeding requiring lobectomy. Mean pulmonary artery pressure decreased from 37 ± 9 mmHg at baseline to 25 ± 8 mmHg at 15 h (P < 0.001) and cardiac index increased from 2.0 ± 0.7 to 2.7 ± 0.9 L/min/m(2) (P < 0.001). Echocardiographic right-to-left ventricular end-diastolic dimension ratio decreased from 1.42 ± 0.21 at baseline to 1.06 ± 0.23 at 24 h (n = 21; P < 0.001). The greatest haemodynamic benefit from USAT was found in patients with high-risk PE and in those with symptom duration < 14 days. CONCLUSION A standardized catheter intervention approach using fixed low-dose USAT for the treatment of intermediate- and high-risk PE was associated with rapid improvement in haemodynamic parameters and low rates of bleeding complications and mortality.
Resumo:
A means of analyzing protein quaternary structure using matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI MS) and chemical crosslinking was evaluated. Proteins of known oligomeric structure, as well as monomeric proteins, were analyzed to evaluate the method. The quaternary structure of proteins of unknown or uncertain structure was investigated using this technique. The stoichiometry of recombinant E. coli carbamoyl phosphate synthetase and recombinant human farnesyl protein transferase were determined to be heterodimers using glutaraldehyde crosslinking, agreeing with the stoichiometry found for the wild type proteins. The stoichiometry of the gamma subunit of E. coli DNA polymerase III holoenzyme was determined in solution without the presence of other subunits to be a homotetramer using glutaraldehyde crosslinking and MALDI MS analysis. Chi and psi subunits of E. coli DNA polymerase III subunits appeared to form a heterodimer when crosslinked with heterobifunctional photoreactive crosslinkers.^ Comparison of relative % peak areas obtained from MALDI MS analysis of crosslinked proteins and densitometric scanning of silver stained sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) gels showed excellent qualitative agreement for the two techniques, but the quantitative analyses differed, sometimes significantly. This difference in quantitation could be due to SDS-PAGE conditions (differential staining, loss of sample) or to MALDI MS conditions (differences in ionization and/or detection). Investigation of pre-purified crosslinked monomers and dimers recombined in a specific ratio revealed the presence of mass discrimination in the MALDI MS process. The calculation of mass discrimination for two different MALDI time-of-flight instruments showed the loss of a factor of approximately 2.6 in relative peak area as the m/z value doubles over the m/z range from 30,000 to 145,000 daltons.^ Indirect symmetry was determined for tetramers using glutaraldehyde crosslinking with MALDI MS analysis. Mathematical modelling and simple graphing allowed the determination of the symmetry for several tetramers known to possess isologous D2 symmetry. These methods also distinguished tetramers that did not fit D2 symmetry such as apo-avidin. The gamma tetramer of E. coli DNA polymerase III appears to have isologous D2 symmetry. ^
Resumo:
BACKGROUND In patients with acute pulmonary embolism, systemic thrombolysis improves right ventricular (RV) dilatation, is associated with major bleeding, and is withheld in many patients at risk. This multicenter randomized, controlled trial investigated whether ultrasound-assisted catheter-directed thrombolysis (USAT) is superior to anticoagulation alone in the reversal of RV dilatation in intermediate-risk patients. METHODS AND RESULTS Fifty-nine patients (63±14 years) with acute main or lower lobe pulmonary embolism and echocardiographic RV to left ventricular dimension (RV/LV) ratio ≥1.0 were randomized to receive unfractionated heparin and an USAT regimen of 10 to 20 mg recombinant tissue plasminogen activator over 15 hours (n=30; USAT group) or unfractionated heparin alone (n=29; heparin group). Primary outcome was the difference in the RV/LV ratio from baseline to 24 hours. Safety outcomes included death, major and minor bleeding, and recurrent venous thromboembolism at 90 days. In the USAT group, the mean RV/LV ratio was reduced from 1.28±0.19 at baseline to 0.99±0.17 at 24 hours (P<0.001); in the heparin group, mean RV/LV ratios were 1.20±0.14 and 1.17±0.20, respectively (P=0.31). The mean decrease in RV/LV ratio from baseline to 24 hours was 0.30±0.20 versus 0.03±0.16 (P<0.001), respectively. At 90 days, there was 1 death (in the heparin group), no major bleeding, 4 minor bleeding episodes (3 in the USAT group and 1 in the heparin group; P=0.61), and no recurrent venous thromboembolism. CONCLUSIONS In patients with pulmonary embolism at intermediate risk, a standardized USAT regimen was superior to anticoagulation with heparin alone in reversing RV dilatation at 24 hours, without an increase in bleeding complications. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT01166997.
Resumo:
Patients with ilio-femoral deep-vein thrombosis (DVT) are at high risk of developing the post-thrombotic syndrome (PTS). In comparison to anticoagulation therapy alone, extended venography-guided catheter-directed thrombolysis without routine stenting of venous stenosis in patients with ilio-femoral DVT is associated with an increased risk of bleeding and a moderate reduction of PTS. We performed a prospective single-centre study to investigate safety, patency and incidence of PTS in patients with acute ilio-femoral DVT treated with fixed-dose ultrasound-assisted catheter-directed thrombolysis (USAT; 20 mg rt-PA during 15 hours) followed by routing stenting of venous stenosis, defined as residual luminal narrowing >50%, absent antegrade flow, or presence of collateral flow at the site of suspected stenosis. A total of 87 patients (age 46 ± 21 years, 60% women) were included. At 15 hours, thrombolysis success ≥50% was achieved in 67 (77%) patients. Venous stenting (mean 1.9 ± 1.3 stents) was performed in 70 (80%) patients, with the common iliac vein as the most frequent stenting site (83%). One major (1%; 95% CI, 0-6%) and 6 minor bleedings (7%; 95%CI, 3-14%) occurred. Primary and secondary patency rates at 1 year were 87% (95% CI, 74-94%) and 96% (95% CI, 88-99%), respectively. At three months, 88% (95% CI, 78-94%) of patients were free from PTS according to the Villalta scale, with a similar rate at one year (94%, 95% CI, 81-99%). In conclusion, a fixed-dose USAT regimen followed by routine stenting of underlying venous stenosis in patients with ilio-femoral DVT was associated with a low bleeding rate, high patency rates, and a low incidence of PTS.
Resumo:
Pulmonary embolism remains a common and potentially life-threatening disease. For patients with intermediate- and high-risk pulmonary embolism, catheter-based revascularization therapy has emerged as potential alternative to systemic thrombolysis or surgical embolectomy. Ultrasound-assisted catheter-directed thrombolysis is a contemporary catheter-based technique and is the focus of the present review. Ultrasound-assisted catheter-directed thrombolysis is more effective in reversing right ventricular dysfunction and dilatation in comparison with anticoagulation alone in patients at intermediate risk. However, a direct comparison of ultrasound-assisted thrombolysis with systemic thrombolysis or surgical thrombectomy is not available. Ultrasound-assisted thrombolysis with initial intrapulmonary thrombolytic bolus may also be effective in high-risk patients, but evidence from randomized trials is not available. This review summarizes current data on ultrasound-assisted thrombolysis for acute pulmonary embolism.
Resumo:
OBJECTIVES To find the best pairing of first and second reader at highest sensitivity for detecting lung nodules with CT at various dose levels. MATERIALS AND METHODS An anthropomorphic lung phantom and artificial lung nodules were used to simulate screening CT-examination at standard dose (100 mAs, 120 kVp) and 8 different low dose levels, using 120, 100 and 80 kVp combined with 100, 50 and 25 mAs. At each dose level 40 phantoms were randomly filled with 75 solid and 25 ground glass nodules (5-12 mm). Two radiologists and 3 different computer aided detection softwares (CAD) were paired to find the highest sensitivity. RESULTS Sensitivities at standard dose were 92%, 90%, 84%, 79% and 73% for reader 1, 2, CAD1, CAD2, CAD3, respectively. Combined sensitivity for human readers 1 and 2 improved to 97%, (p1=0.063, p2=0.016). Highest sensitivities--between 97% and 99.0%--were achieved by combining any radiologist with any CAD at any dose level. Combining any two CADs, sensitivities between 85% and 88% were significantly lower than for radiologists combined with CAD (p<0.03). CONCLUSIONS Combination of a human observer with any of the tested CAD systems provide optimal sensitivity for lung nodule detection even at reduced dose at 25 mAs/80 kVp.
Resumo:
OBJECTIVES The aim of this phantom study was to minimize the radiation dose by finding the best combination of low tube current and low voltage that would result in accurate volume measurements when compared to standard CT imaging without significantly decreasing the sensitivity of detecting lung nodules both with and without the assistance of CAD. METHODS An anthropomorphic chest phantom containing artificial solid and ground glass nodules (GGNs, 5-12 mm) was examined with a 64-row multi-detector CT scanner with three tube currents of 100, 50 and 25 mAs in combination with three tube voltages of 120, 100 and 80 kVp. This resulted in eight different protocols that were then compared to standard CT sensitivity (100 mAs/120 kVp). For each protocol, at least 127 different nodules were scanned in 21-25 phantoms. The nodules were analyzed in two separate sessions by three independent, blinded radiologists and computer-aided detection (CAD) software. RESULTS The mean sensitivity of the radiologists for identifying solid lung nodules on a standard CT was 89.7% ± 4.9%. The sensitivity was not significantly impaired when the tube and current voltage were lowered at the same time, except at the lowest exposure level of 25 mAs/80 kVp [80.6% ± 4.3% (p = 0.031)]. Compared to the standard CT, the sensitivity for detecting GGNs was significantly lower at all dose levels when the voltage was 80 kVp; this result was independent of the tube current. The CAD significantly increased the radiologists' sensitivity for detecting solid nodules at all dose levels (5-11%). No significant volume measurement errors (VMEs) were documented for the radiologists or the CAD software at any dose level. CONCLUSIONS Our results suggest a CT protocol with 25 mAs and 100 kVp is optimal for detecting solid and ground glass nodules in lung cancer screening. The use of CAD software is highly recommended at all dose levels.
Resumo:
BACKGROUND:
Robotics-assisted tilt table technology was introduced for early rehabilitation of neurological patients. It provides cyclical stepping movement and physiological loading of the legs. The aim of the present study was to assess the feasibility of this type of device for peak cardiopulmonary performance testing using able-bodied subjects.
METHODS:
A robotics-assisted tilt table was augmented with force sensors in the thigh cuffs and a work rate estimation algorithm. A custom visual feedback system was employed to guide the subjects' work rate and to provide real time feedback of actual work rate. Feasibility assessment focused on: (i) implementation (technical feasibility), and (ii) responsiveness (was there a measurable, high-level cardiopulmonary reaction?). For responsiveness testing, each subject carried out an incremental exercise test to the limit of functional capacity with a work rate increment of 5 W/min in female subjects and 8 W/min in males.
RESULTS:
11 able-bodied subjects were included (9 male, 2 female; age 29.6 ± 7.1 years: mean ± SD). Resting oxygen uptake (O
Resumo:
STATE OF THE ART The proximal median nerve compression syndrome includes the pronator teres and the Kiloh-Nevin syndrome. This article presents a new surgical technique of endoscopic assisted median nerve decompression. MATERIAL AND SURGICAL TECHNIQUE Endoscopic scissor decompression of the median nerve is always performed under plexus anaesthesia. It includes 6 key steps documented in this article. We review the indications and limitations of the surgical technique. RESULTS Since 2011, three clinical series have highlighted the advantages of this technique. Functional and subjective results are discussed. We also review the limitations of the technique and its potential for future development. CONCLUSION Although clinical results after endoscopic assisted decompression of the median nerve appear excellent they still need to be compared with conventional techniques. Clinical studies are likely to develop primarily due to the mini-invasive nature of this new surgical technique.
Resumo:
Since October 2011, the enzymatic lysis of Dupuytren's cord was introduced in Switzerland (Xiapex(®), Auxilium Pharmaceuticals, Pfizer). Here we present our first university experience and underline the major role of ultrasound during the injection. Between December 2011 and February 2013, 52 injections were performed to eliminate 43 Dupuytren's cords in 33 patients. The mean age of the patients was 64.4 ± 8.5 years. Complications were documented for each patient. Before, directly after and after a minimum of 6 months post-injection, the contracture of the treated joint was measured with use of a goniometer. The DASH score was evaluated after a minimum of 6 months and the patients were asked to subjectively evaluate the outcome of the treatment (very good, good, mild, poor) and whether they would reiterate it if necessary. Four skin defects, one lymphangitis, and one CRPS were responsible for a complication rate of 18%. There was no infection and no tendon rupture in the series. The mean MCP joint contracture was respectively 36.8 ± 27.4°, 3.5 ± 7.8° (gain of mobility compared to the preoperative situation 33.3°, P<0.001), and 8.4 ± 13.9° (gain 28.4°, P<0.001) respectively before, just after and at the long-term clinical control. The mean PIP joint contracture was respectively 36.5 ± 29.1°, 5.9 ± 6.7° (gain 30.6°, P<0.001), and 15.1 ± 13.8° (gain 21.4°, P<0.001) respectively before injection, just after and at the long-term clinical control. The DASH score decreased from 24 ± 14 to 7 ± 9 (P<0.001). Eighty-one per cent of the patients were satisfied or very satisfied of the treatment. All but two would reiterate the treatment if necessary. Ultrasound is able to target the injection of collagenase in order to reduce complications. The short-term results of this non-invasive therapy are very promising however comparison with conventional procedures is difficult as the long-term results are lacking.