845 resultados para WSN, Routing, Lifetime, Energy, Save, Power, CC2530, Texas, Standard IEEE 802.15.4


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a measurement of the top quark mass with the matrix element method in the lepton+jets final state. As the energy scale for calorimeter jets represents the dominant source of systematic uncertainty, the matrix element likelihood is extended by an additional parameter, which is defined as a global multiplicative factor applied to the standard energy scale. The top quark mass is obtained from a fit that yields the combined statistical and systematic jet energy scale uncertainty. Using a data set of 0.4 fb(-1) taken with the D0 experiment at Run II of the Fermilab Tevatron Collider, the mass of the top quark is measured using topological information to be: m(top)(center dot+jets)(topo)=169.2(-7.4)(+5.0)(stat+JES)(-1.4)(+1.5)(syst) GeV, and when information about identified b jets is included: m(top)(center dot+jets)(b-tag)=170.3(-4.5)(+4.1)(stat+ JES)(-1.8)(+1.2)(syst) GeV. The measurements yield a jet energy scale consistent with the reference scale.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a study of eey and mu mu gamma events using 1109 (1009) pb-(1) of data in the electron (muon) channel, respectively. These data were collected with the DO detector at the Fermilab Tevatron pp collider at Is = 1.96 TeV. Having observed 453 (515) candidates in the eey (jtAy) final state, we measure the Z gamma production cross section for a photon with transverse energy ET > 7 GeV, separation between the photon and leptons Delta Rey > 0.7, and invariant mass of the di-lepton pair Mee > 30 GeV/(2)(c), to be 4.96 0.30(stat. + syst.) zE 0.30(lumi.) pb, in agreement with the Standard Model prediction of 4.74 0.22 pb. This is the most precise Zy cross section measurement at a hadron collider. We set limits on anomalous trilinear Zyy and ZZy gauge boson couplings of -0.085 < h(30)(y) < 0.084, -0.0053 < h(40)(y) < 0.0054 and -0.083 < h(30)(Z) < 0.082, 30 40 30 -0.0053 < h(40)(Z) < 0.0054 at the 95% C.L. for the form-factor scale A = 1.2 TeV. 40 Published by Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Large scale combinatorial problems such as the network expansion problem present an amazingly high number of alternative configurations with practically the same investment, but with substantially different structures (configurations obtained with different sets of circuit/transformer additions). The proposed parallel tabu search algorithm has shown to be effective in exploring this type of optimization landscape. The algorithm is a third generation tabu search procedure with several advanced features. This is the most comprehensive combinatorial optimization technique available for treating difficult problems such as the transmission expansion planning. The method includes features of a variety of other approaches such as heuristic search, simulated annealing and genetic algorithms. In all test cases studied there are new generation, load sites which can be connected to an existing main network: such connections may require more than one line, transformer addition, which makes the problem harder in the sense that more combinations have to be considered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have investigated and extensively tested three families of non-convex optimization approaches for solving the transmission network expansion planning problem: simulated annealing (SA), genetic algorithms (GA), and tabu search algorithms (TS). The paper compares the main features of the three approaches and presents an integrated view of these methodologies. A hybrid approach is then proposed which presents performances which are far better than the ones obtained with any of these approaches individually. Results obtained in tests performed with large scale real-life networks are summarized.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The simulated annealing optimization technique has been successfully applied to a number of electrical engineering problems, including transmission system expansion planning. The method is general in the sense that it does not assume any particular property of the problem being solved, such as linearity or convexity. Moreover, it has the ability to provide solutions arbitrarily close to an optimum (i.e. it is asymptotically convergent) as the cooling process slows down. The drawback of the approach is the computational burden: finding optimal solutions may be extremely expensive in some cases. This paper presents a Parallel Simulated Annealing, PSA, algorithm for solving the long term transmission network expansion planning problem. A strategy that does not affect the basic convergence properties of the Sequential Simulated Annealing algorithm have been implementeded and tested. The paper investigates the conditions under which the parallel algorithm is most efficient. The parallel implementations have been tested on three example networks: a small 6-bus network, and two complex real-life networks. Excellent results are reported in the test section of the paper: in addition to reductions in computing times, the Parallel Simulated Annealing algorithm proposed in the paper has shown significant improvements in solution quality for the largest of the test networks.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work the influence of two different iron sources, Fe(NO3)(3) and complexed ferrioxalate (FeOx), on the degradation efficiency of 4-chlorophenol (4CP), malachite green, formaldehyde, dichloroacetic acid (DCA) and the commercial products of the herbicides diuron and tebuthiuron was studied. The oxidation of 4CP, DCA, diuron and tebuthiuron shows a strong dependence on the iron source. While the 4CP degradation is favored by the use of Fe(NO3)(3), the degradation of DCA and the herbicides diuron and tebuthiuron is most efficient when ferrioxalate is used. on the other hand, the degradation of malachite green and formaldehyde is not very influenced by the iron source showing only a slight improvement when ferrioxalate is used. In the case of formaldehyde, DCA, diuron and tebuthiuron, despite of the additional carbon introduced by the use of ferrioxalate, higher mineralization percentages were observed, confirming the beneficial effect of ferrioxalate on the degradation of these compounds. The degradation of tebuthiuron was studied in detail using a shallow pond type solar flow reactor of 4.5 L capacity and 4.5 cm solution depth. Solar irradiation of tebuthiuron at a flow rate of 9 L h(-1), in the presence of 10.0 mmol L-1 H2O2 and 1.0 mmol L-1 ferrioxalate resulted in complete conversion of this herbicide and 70% total organic carbon removal. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The capacitor placement (replacement) problem for radial distribution networks determines capacitor types, sizes, locations and control schemes. Optimal capacitor placement is a hard combinatorial problem that can be formulated as a mixed integer nonlinear program. Since this is a NP complete problem (Non Polynomial time) the solution approach uses a combinatorial search algorithm. The paper proposes a hybrid method drawn upon the Tabu Search approach, extended with features taken from other combinatorial approaches such as genetic algorithms and simulated annealing, and from practical heuristic approaches. The proposed method has been tested in a range of networks available in the literature with superior results regarding both quality and cost of solutions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of combining the photocatalytic processes using TiO 2 and the photo-Fenton reaction with Fe3+ or ferrioxalate as a source of Fe2+ was investigated in the degradation of 4-chlorophenol (4CP) and dichloroacetic acid (DCA) using solar irradiation. Multivariate analysis was used to evaluate the role of three variables: iron, H2O2 and TiO2 concentrations. The results show that TiO2 plays a minor role when compared to iron and H2O2 in the solar degradation of 4CP and DCA in the studied conditions. However, its presence can improve TOC removal when H2O2 is totally consumed. Iron and peroxide play major roles, especially when Fe(NO3)3 used in the degradation of 4CP. No significant synergistic effect was observed by the addition of TiO 2 in this process. On the other hand, synergistic effects were observed between FeOx and TiO2 and between H 2O2 and TiO2 in the degradation of DCA. © IWA Publishing 2004.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an alternative methodology for loading margin improvement and total real power losses reduction by using a continuation method. In order to attain this goal, a parameterizing equation based on the total real power losses and the equations of the reactive power at the slack and generation buses are added to the conventional power flow equations. The voltages at these buses are considered as control variables and a new parameter is chosen to reduce the real power losses in the transmission lines. The results show that this procedure leads to maximum loading point increase and consequently, in static voltage stability margin improvement. Besides, this procedure also takes to a reduction in the operational costs and, simultaneously, to voltage profile improvement. Another important result of this methodology is that the resulting operating points are close to that provided by an optimal power flow program. © 2004 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a study of eeγ and μμγ events using 1109 (1009) pb-1 of data in the electron (muon) channel, respectively. These data were collected with the DØ detector at the Fermilab Tevatron p over(p, ̄) collider at sqrt(s) = 1.96   TeV. Having observed 453 (515) candidates in the eeγ (μμγ) final state, we measure the Zγ production cross section for a photon with transverse energy ET > 7   GeV, separation between the photon and leptons Δ Rℓ γ > 0.7, and invariant mass of the di-lepton pair Mℓ ℓ > 30   GeV / c2, to be 4.96 ± 0.30 (stat . + syst .) ± 0.30 (lumi .)   pb, in agreement with the Standard Model prediction of 4.74 ± 0.22   pb. This is the most precise Zγ cross section measurement at a hadron collider. We set limits on anomalous trilinear Zγγ and ZZγ gauge boson couplings of - 0.085 < h30 γ < 0.084, - 0.0053 < h40 γ < 0.0054 and - 0.083 < h30 Z < 0.082, - 0.0053 < h40 Z < 0.0054 at the 95% C.L. for the form-factor scale Λ = 1.2   TeV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: This study aimed to determine the energy expenditure (EE) in terms of caloric cost and metabolic equivalents (METs) of two sessions of an exercise protocol. Methods: Fifteen subjects (51.0 ± 5.5years) performed the exercise sessions (80min), which were composed by (warming, walking and flexibility exercises; Session A) and (warming, walking and local muscular endurance exercises; Session B). Heart hate (HR) was measured during each part of the sessions. In laboratory environment, maximal oxygen consumption (VO2max) and oxygen uptake in rest and exercise conditions (using mean HR obtained in classes) were measured on different days, using indirect calorimetry. Exercise METs were obtained by dividing VO2 in exercise (mL.kg-1.min-1) by VO2 in rest (mL.kg-1.min-1). The EE of the exercises was calculated by the formula: MET x Weight(kg) x Time(min)/60. The results were analyzed by ANOVA with Tuckey post hoc test (p < 0.05). Results: One MET for this group was 2.7 ± 0.1mL.kg-1.min-1. The mean METs of exercises were 4,7 ± 0,8 (warming), 5,8 ± 0,9 (walking) and 3,6 ± 0,7 (flexibility) on session A, and 4,6 ± 1,2 (warming), 5,6 ± 1,0 (walking) and 4.8 ± 1,0 (local muscular endurance exercises) on Session B. The training sessions showed similar energy cost (A: 398 ± 86.72 kcal and B: 404 ± 38.85 kcal; p > 0,05). None of activities were classified into vigorous intensity (> 7 METs). There were no differences on VO2 between walking (15,6 ± 2,8 or 15,4 ± 2,6 mL.kg-1.min-1) and local muscular endurance exercises (13,2 ± 2,9 mL.kg-1.min-1), although both were higher (p > 0.05) than flexibility exercises (10.1 ± 2.2 mL.kg-1.min-1). Conclusion: The proposed protocol achieves the physical activity needed by healthy adults to improve and maintain health, by their structure, moderate intensity, duration, frequency and caloric expenditure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)