865 resultados para Validation of analytical methods
Resumo:
Objectives: The present study evaluates the reliability of the Radio Memory® software (Radio Memory; Belo Horizonte,Brasil.) on classifying lower third molars, analyzing intra- and interexaminer agreement of the results. Study Design: An observational, descriptive study of 280 lower third molars was made. The corresponding orthopantomographs were analyzed by two examiners using the Radio Memory® software. The exam was repeated 30 days after the first observation by each examiner. Both intra- and interexaminer agreement were determined using the SPSS v 12.0 software package for Windows (SPSS; Chicago, USA). Results: Intra- and interexaminer agreement was shown for both the Pell & Gregory and the Winter classifications, p<0.01, with 99% significant correlation between variables in all the cases. Conclusions: The use of Radio Memory® software for the classification of lower third molars is shown to be a valid alternative to the conventional method (direct evaluation on the orthopantomograph), for both clinical and investigational applications.
Resumo:
The purpose of this study is the adaptation and validation of the"Survey Work-Home Interaction NijmeGen" (SWING) developed by Geurts and colleagues to Spanish speaking countries (SWING-SSC). In order to analyze the questionnaire"s psychometric properties, confirmatory factor analysis (CFA) was carried out with a sample of 203 employees from various Spanish-speaking countries. Criterion related validity was tested by examining correlations between the SWING-SSC, and the theoretically relevant variables: health, role conflict, role clarity and supervisor support. Finally, reliability was tested analyzing the internal consistency of the scales. The analyses carried out indicate that SWING-SSC has good psychometric properties. In addition, the present results support the relation of the construct with health, role conflict, role clarity, and supervisor support. This study offers evidence for a sound work-life balance measure that contributes to the encouragement adequate conditions in the workplace, to reduce the conflict between the two spheres of professional and personal life, and to enhance positive relationships.
Resumo:
We have designed and validated a novel generic platform for production of tetravalent IgG1-like chimeric bispecific Abs. The VH-CH1-hinge domains of mAb2 are fused through a peptidic linker to the N terminus of mAb1 H chain, and paired mutations at the CH1-CL interface mAb1 are introduced that force the correct pairing of the two different free L chains. Two different sets of these CH1-CL interface mutations, called CR3 and MUT4, were designed and tested, and prototypic bispecific Abs directed against CD5 and HLA-DR were produced (CD5xDR). Two different hinge sequences between mAb1 and mAb2 were also tested in the CD5xDR-CR3 or -MUT4 background, leading to bispecific Ab (BsAbs) with a more rigid or flexible structure. All four Abs produced bound with good specificity and affinity to CD5 and HLA-DR present either on the same target or on different cells. Indeed, the BsAbs were able to efficiently redirect killing of HLA-DR(+) leukemic cells by human CD5(+) cytokine-induced killer T cells. Finally, all BsAbs had a functional Fc, as shown by their capacity to activate human complement and NK cells and to mediate phagocytosis. CD5xDR-CR3 was chosen as the best format because it had overall the highest functional activity and was very stable in vitro in both neutral buffer and in serum. In vivo, CD5xDR-CR3 was shown to have significant therapeutic activity in a xenograft model of human leukemia.
Resumo:
COD discharges out of processes have increased in line with elevating brightness demands for mechanical pulp and papers. The share of lignin-like substances in COD discharges is on average 75%. In this thesis, a plant dynamic model was created and validated as a means to predict COD loading and discharges out of a mill. The assays were carried out in one paper mill integrate producing mechanical printing papers. The objective in the modeling of plant dynamics was to predict day averages of COD load and discharges out of mills. This means that online data, like 1) the level of large storage towers of pulp and white water 2) pulp dosages, 3) production rates and 4) internal white water flows and discharges were used to create transients into the balances of solids and white water, referred to as “plant dynamics”. A conversion coefficient was verified between TOC and COD. The conversion coefficient was used for predicting the flows from TOC to COD to the waste water treatment plant. The COD load was modeled with similar uncertainty as in reference TOC sampling. The water balance of waste water treatment was validated by the reference concentration of COD. The difference of COD predictions against references was within the same deviation of TOC-predictions. The modeled yield losses and retention values of TOC in pulping and bleaching processes and the modeled fixing of colloidal TOC to solids between the pulping plant and the aeration basin in the waste water treatment plant were similar to references presented in literature. The valid water balances of the waste water treatment plant and the reduction model of lignin-like substances produced a valid prediction of COD discharges out of the mill. A 30% increase in the release of lignin-like substances in the form of production problems was observed in pulping and bleaching processes. The same increase was observed in COD discharges out of waste water treatment. In the prediction of annual COD discharge, it was noticed that the reduction of lignin has a wide deviation from year to year and from one mill to another. This made it difficult to compare the parameters of COD discharges validated in plant dynamic simulation with another mill producing mechanical printing papers. However, a trend of moving from unbleached towards high-brightness TMP in COD discharges was valid.
Resumo:
The purpose of the present study was to examine the clinical validation of a Virtual Reality Environment (VRE) designed to normalize eating patterns in Eating Disorders (ED). The efficacy of VR in eliciting emotions, sense of presence and reality of the VRE were explored in 22 ED patients and 37 healthy eating individuals. The VRE (non-immersive) consisted of a kitchen room where participants had to eat a virtual pizza. In order to assess the sense of presence and reality produced by the VRE, participants answered seven questions with a Likert scale (0-10) during the experience, and then filled out the Reality Judgment and Presence Questionnaire (RJPQ) and ITC-Sense of Presence Inventory (ITC-SOPI). The results showed that the VRE induced a sense of presence and was felt as real for both groups, without differences in the experience of 'ease' with the VRE, sense of physical space, or the ecological validity assigned to the virtual kitchen and eating virtually. However, the ED patients reported paying more attention and experiencing greater emotional involvement and dysphoria after virtual eating. The results suggest that the VRE was clinically meaningful to the ED patients and might be a relevant therapy tool for normalizing their eating patterns.
Resumo:
Mixed methods research involves the combined use of quantitative and qualitative methods in the same research study, and it is becoming increasingly important in several scientific areas. The aim of this paper is to review and compare through a mixed methods multiple-case study the application of this methodology in three reputable behavioural science journals: the Journal of Organizational Behavior, Addictive Behaviors and Psicothema. A quantitative analysis was carried out to review all the papers published in these journals during the period 2003-2008 and classify them into two blocks: theoretical and empirical, with the latter being further subdivided into three subtypes (quantitative, qualitative and mixed). A qualitative analysis determined the main characteristics of the mixed methods studies identified, in order to describe in more detail the ways in which the two methods are combined based on their purpose, priority, implementation and research design. From the journals selected, a total of 1.958 articles were analysed, the majority of which corresponded to empirical studies, with only a small number referring to research that used mixed methods. Nonetheless, mixed methods research does appear in all the behavioural science journals studied within the period selected, showing a range of designs, where the sequential equal weight mixed methods research design seems to stand out.
Resumo:
Mixed methods research is becoming increasingly important in several scientific areas. The analysis of prevalence rates is a new line of research that has emerged in mixed methods research, and this methodological approach has only been applied carefully in a handful of journals. The purpose of this article was to analyse the prevalence of mixed methods research in interdisciplinary educational journals. Moreover, the main characteristics of the mixed methods articles identified were examined. This study used a mixed methods approach to analyse these aspects. Specifically, a partially mixed sequential equal status multiple-case study design was applied with a development mixed methods purpose. Three educational journals in different disciplines were reviewed from 2005 to 2010 (Academy of Management Learning and Education, Educational Psychology Review, Journal of the Learning Sciences). The findings show differences among the journals in the prevalence rates and characteristics of the mixed methods studies
Resumo:
Plastic packaging materials intended for use in food packaging is an area of great interest from the scientific and economic point of view due to the irreversible internationalization and globalization process of food products. Nevertheless, a debate related to food safety aspects has emerged within the scientific community. Therefore, the development of analytical methods that allow identifying and quantifying chemical substances of toxicological potential in the packaging is considered essential. This article focuses on the main analytical methods, including validation parameters, as well as extraction and quantification techniques for determination of volatile organic compounds from food packaging materials.
Resumo:
A dissolution test for telithromycin tablets was validated and developed. In order to choose the most discriminatory one, the conditions to carry out are 900 mL of sodium phosphate buffer at pH 7.5, paddles at 50 rpm stirring speed, time test set to 60 min and using USP apparatus 2 with paddles. The UV spectrophotometric method for determination of telithromycin released was developed and validated. The method presents linearity (r = 1) in the concentration range of 20-60 µg/mL. Precision and recoveries were good, 100.62 and 97.06%, respectively. The method was successfully used for the dissolution test of telithromycin tablets.
Resumo:
A sensitive RP-HPLC method with UV detection successfully measured phenol(s) in an ointment containing 3% Stryphnodendron adstringens extract. Chromatography used acetonitrile (0.05% trifluoroacetic acid):water (0.05% trifluoroacetic acid) (v/v), flow rate 0.8 mL min-1. Quantitation was accomplished by the external-standard method. Linearity for 2.00 to 16.00 μg mL-1 (gallic acid) and 1.14 to 18.24 μg mL-1 (gallocatechin) was established. Intra- and inter-day precision levels were under 5%. LOD and LOQ were 0.231 and 0.770 μg mL-1 (gallic acid) and 0.151 and 0.504 μg mL-1 (gallocatechin), respectively. Determination of phenols was unaffected by product excipients.
Resumo:
A LC-ESI-MS/MS method was developed and validated according to the European Union decision 2002/657/EC, for the determination of tetracyclines (TCs) in chicken-muscle since Europe is one of the main markets for Brazilian products. Linearity of r > 0.9979, limits of quantification in the range of 7.0-35.0 ng/g, average recoveries of 89.38 - 106.27%, within-day and between-day precision were adequate for all TCs. The decision limit and the detection capability were 93.00-106.46 ng/g and 95.84-114.38 ng/g, respectively. This method is suitable for application in surveillance programmes of residues of TCs in chicken-muscle samples.
Resumo:
An HPLC method was developed and validated aiming to quantify the cyclosporine-A incorporated into intraocular implants, released from them; and in direct contact with the degradation products of PLGA. The separation was carried out in isocratic mode using acetonitrile/water (70:30) as mobile phase, a C18 column at 80 ºC and UV detection at 210 nm. The method provided selectivity based on resolution among peaks. It was linear over the range of 2.5-40.0 µg/mL. The quantitation and detection limits were 0.8 and 1.2 µg/mL, respectively. The recovery was 101.8% and intra-day and inter-day precision was close to 2%.
Resumo:
The present work describes a novel stability-indicating reversed-phase ultra performance liquid chromatography method for the separation and quantification of rosuvastatin (RSV) and its related impurities in the pharmaceutical dosage forms under forced degradation conditions. An unknown degradation impurity detected in the acid degradation was identified by using quadrupole time-of-flight mass spectrometry. The chromatographic separation was carried out on C-18 column (100 x 2.1 mm, 1.7 μm) using isocratic elution with methanol and 0.1% trifluoroacetic acid (50:50). The total run time was 12 min within which RSV as well as all related impurities and degradation products were separated. The developed method was validated for RSV and related impurities in pharmaceutical dosage forms.
Resumo:
This work describes the development and validation of a dissolution test for 60 mg of diltiazem hydrochloride in immediate release capsules. The best dissolution in vitro profile was achieved using potassium phosphate buffer at pH 6.8 as the dissolution medium and paddle as the apparatus at 50 rpm. The drug concentrations in the dissolution media were determined by UV spectrophotometry and HPLC and a statistical analysis revealed that there were significant differences between HPLC and spectrophotometry. This study illustrates the importance of an official method for the dissolution test, since there is no official monograph for diltiazem hydrochloride in capsules.