992 resultados para VESSEL PHANTOM


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To compare the outcome of balloon PTCA with final coronary stenosis diameter (SD) <=30%, with elective coronary stenting. METHODS: We performed a comparative analysis of the 6 month outcomes in patients treated with primary stenting and those who obtained an optimal balloon PTCA result treated during the first 12 hours of AMI onset included in the STENT PAMI randomized trial. RESULTS: The results were analysed into 3 groups: primary stenting (441 patients, SD=22±6%), optimal PTCA (245 patients), and nonoptimal PTCA (182 patients, SD= 37±5%). At the end of the 6 months primary stent group presented with the lowest restenosis(23 vs. 31 vs. 45%, p=0.001, respectively). Ischemia-driven target vessel revascularization rate (TVR) (7 vs. 15.5 vs. 19%, p=0.001, respectively). CONCLUSION: At the 6 month follow-up, primary stenting offered the lowest restenosis and ischemia-driven TVR rates. Compared to optimal balloon PTCA. Nonoptimal primary balloon PTCA pts (SD=31-50%), had the worst late angiographic outcomes and should be treated more actively with coronary stent implantation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aneurysm of the left main coronary artery is a rare angiographic finding, with few cases described in the international literature. We report the case of a 42-year-old male with a previous history of acute myocardial infarction, whose coronariography indicated triple vessel coronary disease and an aneurysm of the left main coronary artery. A review of the etiology, clinical aspects, and surgical management of coronary arterial aneurysm is presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: We conducted a comparative analysis of the in-hospital outcomes of patients who underwent primary percutaneous transluminal angioplasty (PTCA) or stent implantation because of an acute myocardial infarction (AMI) related to an acute vein graft occlusion. METHODS: Since 1991 the Brazilian Society of Hemodynamic and Interventional Cardiology has maintained a large database (CENIC). From these, we selected all consecutive patients, who underwent primary PTCA or stenting in the first 24 hours of AMI, with the target vessel being an occluded vein graft. Immediate results and major coronary events occurring up until hospital discharge were analyzed. RESULTS: During this period, 5,932 patients underwent primary PTCA or stenting; 158 (3%) of the procedures were performed because of an acute vein graft occlusion. Stenting was performed in 74 (47%) patients. Patients treated with stents had a higher success rate and lower mean residual stenosis compared with those who underwent primary balloon PTCA. The incidence of reinfarction and death were similar for stenting and balloon PTCA. CONCLUSION: Primary percutaneous treatment of AMI related to acute vein graft occlusion is still an uncommon practice. Primary stenting improved luminal diameter and offered higher rates of success; however, this strategy did not reduce the in-hospital reinfarction and death rate, compared with that occurring with PTCA treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE - This analysis was undertaken to determine the composite incidence of cumulative adverse events (death, reinfarction, disabling stroke, and target vessel revascularization) at the end of the first year after acute myocardial infarction, in diabetic patients who underwent coronary stenting or primary coronary balloon angioplasty. METHODS - From the STENT PAMI trial, we analyzed the 6-month angiographic and 1-year clinical outcomes of 135 diabetic (112, noninsulin dependent) patients who underwent the randomization process of the trial and compared them with 758 nondiabetic patients. RESULTS - Coronary stenting did not significantly reduce the primary composite clinical end point when compared with PTCA (20 vs. 30%, p=0.2). A significant benefit from stenting was observed in patients with noninsulin dependent diabetes, with a trend toward a lesser need for new revascularization procedures (10 vs. 21%, p<.001), with a significant reduction in the primary composite clinical end point at 1 year (12 vs. 28%, p=. 04). At 6 months, the restenosis rate were significantly reduced only in nondiabetic patients (18 vs. 33%, p<. 001). Diabetic patients had the same restenosis rate (38%) either with stenting or balloon PTCA. CONCLUSIONS - Coronary Stenting in diabetics noninsulin dependent offered a significant reduction in the composite incidence of major clinical adverse events compared with balloon PTCA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report a case in which the Amplatzer device for percutaneous occlusion of ductus arteriosus was successfully used for occluding a large systemic-pulmonary collateral vessel in a patient who had previously undergone surgery for correction of pulmonary atresia and ventricular septal defect (Rastelli technique), and was awaiting the change of a cardiac tube. In the first attempt, the device embolized to the distal pulmonary bed and, after being rescued with a Bitome, it was appropriately repositioned with no complications and with total occlusion of the vessel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To verify the possible role of adventitial inflammation in atherosclerotic plaque vulnerability and coronary artery remodelling. METHODS: We compared the mean numbers of lymphocytes in the adventitia and in the plaque of ruptured thrombosed and stable equi-stenotic coronary segments of 34 patients who died due to acute myocardial infarction. We also analysed adventitial microvessels, adventitial fibrosis and the external elastic membrane. RESULTS: In the adventitia, the numbers of lymphocytes and microvessels/mm² were 69.5±88.3 and 60.9± 32.1 in culprit lesions and 16.4 ± 21.1 and 44.3±16.1 in stable lesions (p<0.05); within the plaques, the mean number of lymphocytes was 24±40.8 in culprit lesions and 10.9±13.2 in stable ones (p=0.17). The mean percent area of adventitial fibrosis/cross-sectional area of the vessel was significantly lower in unstable plaques (p<0.001). The confocal images showed holes in the external elastic membrane. CONCLUSION: Unstable plaques exhibit chronic pan-arteritis, accompanied by enlargement, medial thinning, and less fibrosis than in stable lesions, which is compatible with vessel aneurysm. Adventitial inflammation may contribute significantly to atheroma instability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE:To verify the influence of moderate- or high-pressure balloon inflation during primary coronary stent implantation for acute myocardial infarction. METHODS: After successful coronary stent implantation, 82 patients were divided into 2 groups according to the last balloon inflation pressure: group 1 (³12 to <16 atm) and group 2 (³16 to 20 atm), each with 41 cases. All patients underwent late coronary angiography. RESULTS: In group 1, the mean stent deployment pressure was 13.58±0.92 atm, and in the group 2 it was 18.15±1.66 atm. Stents implanted with moderate pressures (³12 to <16 atm) had a significantly smaller postprocedural minimal lumen diameter, compared to with those with higher pressure, with lesser acute gain (2.7± 0.4 mm vs 2.9±04 mm; p=0.004), but the late lumen loss (0,9±0,8 mm vs 0,9±0,6 mm) and the restenosis (22% vs. 17.1%) and target-vessel revascularization rates (9.8% vs 7.3%) were similar between the groups. CONCLUSION: During AMI stenting, the use of high pressures (³16 atm) did not cause a measurable improvement in late outcome, either in the late loss, its index, and the net gain, or in clinical and angiographic restenosis rates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To study atheromas, Mycoplasma pneumoniae (M. pneumoniae), and Chlamydia pneumoniae (C. pneumoniae). METHODS: C. pneumoniae was studied with immunohistochemistry and M. pneumoniae with in situ hybridization (ISH), in segments of coronary arteries (SCA) as follows: group A - thrombosed ruptured plaques (TRP) of 23 patients who died due to acute myocardial infarction (AMI); group B - 23 nonruptured plaques (NRP) of group A patients; group C - NRP of 11 coronary patients who did not die due to AMI; and group D - 11 SCA from patients with dilated cardiomyopathy or Chagas' disease without atherosclerosis. RESULTS: The mean number of C. pneumoniae+ cells/400x in groups A, B, C, and D was, respectively, 3.3±3.6; 1.0±1.3; 1.2±2.4; and 0.4±0.3; and the percentage of M. pneumoniae area was, respectively, 3.9±3.5; 1.5± 1.6; 0.9±0.9; and 0.4±0.2. More M. pneumoniae and C. pneumoniae were found in of group A than in group B (P<0.01). Good correlation was seen between the area of the vessel and the M. pneumoniae area in the plaque (r = 0.46; P=0.001) and between C. pneumoniae+ cells and CD4+ T lymphocytes (r = 0.42; P<0.01). The number of C. pneumoniae+ cells correlated with CD20+ B cells (r=0.48; P<0.01). CONCLUSION: M. pneumoniae and C. pneumoniae are more frequently found in TRP correlate with the intensity of the inflammation and diameter of the vessel (positive remodeling).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to verify whether HDL particles isolated from patients with coronary artery disease (CAD) and low HDL-C had diminished ability to promote cholesterol efflux from cultured cells compared with HDL isolated from subjects without CAD and with normal HDL-C. METHODS: Smooth muscle cells isolated from human aortas cultured and radiolabeled with ³H-cholesterol were loaded with cholesterol and incubated with increasing concentrations of HDL isolated from 13 CAD patients with low HDL-C (CAD group) or from 5 controls without CAD (C group). Efflux of cellular cholesterol was measured by cellular depletion of radiolabeled cholesterol and by the appearance of ³H-cholesterol into experimental medium expressed as a percentage of total labeled cholesterol. RESULTS: Cholesterol efflux increased with the amount of HDL present in the medium, and no difference was found between groups at various HDL protein concentrations: efflux was 28 ± 6.3% (C) and 25.5 ± 8.9% (CAD) with 25 mg/mL; 34 ± 4.3% (C) and 31.9 ± 6.6% (CD) with 50 mg/mL and 39.5 ± 3.5% (C) and 37.1 ± 4.4% (CAD) with 100 mg/mL, HDL. CONCLUSION: Because the HDL fraction of CAD patients with low HDL-C have normal ability to extract cholesterol from cells of the vessel wall, it is suggested that low HDL-C atherogenicity should be ascribed to diminished concentrations of HDL particles rather than to the qualitative properties of the HDL fraction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To obtain information about the profile and behavior of a population with ischemic heart disease undergoing cine coronary angiography and to determine disease severity. METHODS: Retrospective study assessing patients hospitalized at InCor from 1986 to 1995, in which the variables age, sex, and number of major coronary arteries with obstruction degree > 40% were analyzed. RESULTS: We studied 18,221 patients and observed a significant increase in the number of females (22.8% to 25.2%, P=0.001) and an increase in age (57.1±29.3 to 60.4±10.7 years, P=0.0001). A significant increase in the incidence of multivessel disease was observed, which was more frequent among males (69.2% and 64.5%) and among the older patients (59.8±9.8 and 56.8±10.7 years, P=0.0001). A reduction in the incidence of single-vessel disease was also observed (66.2% vs 69.2% and 33.8% vs 30.5%, respectively, P<0.0001). CONCLUSION: A change in the profile of the population studied was observed as follows: patients undergoing cine coronary angiography at InCor were older, had a greater number of impaired major coronary arteries, and the number of females affected increased, leading to indices suggestive of a poorer prognosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

FUNDAMENTO: A Doença Arterial Coronariana (DAC) é a aterosclerose das artérias coronárias que transportam o sangue para o coração. A aterosclerose é uma doença inflamatória. As variações gênicas das citocinas - como as associadas à família IL1 - fazem parte da patogênese da aterosclerose. OBJETIVO: O objetivo deste estudo foi determinar a relação entre os polimorfismos da família IL1 (VNTR do IL1RN, posições -511 e +3953 do IL1B) e a DAC na população turca. MÉTODOS: Um total de 427 indivíduos foram submetidos à angiografia coronariana e em seguida divididos da seguinte forma: 170 no grupo controle e 257 no grupo de pacientes com DAC. Os sujeitos com DAC foram divididos em dois subgrupos: 91 no grupo de Doença Coronariana em um único vaso (Single Vessel Disease - SVD) e 166 no grupo Doença Coronariana em múltiplos vasos (Multiple Vessel Disease - MVD). Os genótipos de IL1RN e IL1B (-511, +3953) foram determinados por reação em cadeia da polimerase (RCP), seguida de análise da digestão por enzima de restrição. RESULTADOS: Não foram observadas diferenças significantes nas distribuições de genótipos de IL1RN e IL1B (-511 e +3953) entre os sujeitos com DAC e os controles, ou entre sujeitos com MVD e controles. No entanto, observou-se uma relação significante no genótipo IL1RN 2/2 entre sujeitos portadores de SVD e controles (P= 0,016, x2: 10,289, OR: 2,94IC 95% 1,183 - 7,229). Tampouco foi observada diferença estatisticamente significante nas freqüências dos alelos de IL1RN e IL1B (-511 e +3953) entre os sujeitos com DAC e controles, os sujeitos com MVD e controles, ou ainda os sujeitos SVD e controles. CONCLUSÃO: Não foi observada nenhuma relação na freqüência alélica e nem na distribuição genotípica dos polimorfismos de IL1RN e IL1B entre sujeitos com DAC e grupos controle. No entanto, o genótipo IL1RN 2/2 pode representar um fator de risco para sujeitos com SVD na população turca.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A composting Heat Extraction Unit (HEU) was designed to utilise waste heat from decaying organic matter for a variety of heating application The aim was to construct an insulated small scale, sealed, organic matter filled container. In this vessel a process fluid within embedded pipes would absorb thermal energy from the hot compost and transport it to an external heat exchanger. Experiments were conducted on the constituent parts and the final design comprised of a 2046 litre container insulated with polyurethane foam and kingspan with two arrays of qualpex piping embedded in the compost to extract heat. The thermal energy was used in horticultural trials by heating polytunnels using a radiator system during a winter/spring period. The compost derived energy was compared with conventional and renewable energy in the form of an electric fan heater and solar panel. The compost derived energy was able to raise polytunnel temperatures to 2-3°C above the control, with the solar panel contributing no thermal energy during the winter trial and the electric heater the most efficient maintaining temperature at its preset temperature of 10°C. Plants that were cultivated as performance indicators showed no significant difference in growth rates between the heat sources. A follow on experiment conducted using special growing mats for distributing compost thermal energy directly under the plants (Radish, Cabbage, Spinach and Lettuce) displayed more successful growth patterns than those in the control. The compost HEU was also used for more traditional space heating and hot water heating applications. A test space was successfully heated over two trials with varying insulation levels. Maximum internal temperature increases of 7°C and 13°C were recorded for building U-values of 1.6 and 0.53 W/m2K respectively using the HEU. The HEU successfully heated a 60 litre hot water cylinder for 32 days with maximum water temperature increases of 36.5°C recorded. Total energy recovered from the 435 Kg of compost within the HEU during the polytunnel growth trial was 76 kWh which is 3 kWh/day for the 25 days when the HEU was activated. With a mean coefficient of performance level of 6.8 calculated for the HEU the technology is energy efficient. Therefore the compost HEU developed here could be a useful renewable energy technology particularly for small scale rural dwellers and growers with access to significant quantities of organic matter

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background:Long-term outcomes of drug-eluting stents (DES) versus bare-metal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI) remain uncertain.Objective:To investigate long-term outcomes of drug-eluting stents (DES) versus bare-metal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI).Methods:We performed search of MEDLINE, EMBASE, the Cochrane library, and ISI Web of Science (until February 2013) for randomized trials comparing more than 12-month efficacy or safety of DES with BMS in patients with STEMI. Pooled estimate was presented with risk ratio (RR) and its 95% confidence interval (CI) using random-effects model.Results:Ten trials with 7,592 participants with STEMI were included. The overall results showed that there was no significant difference in the incidence of all-cause death and definite/probable stent thrombosis between DES and BMS at long-term follow-up. Patients receiving DES implantation appeared to have a lower 1-year incidence of recurrent myocardial infarction than those receiving BMS (RR = 0.75, 95% CI 0.56 to 1.00, p= 0.05). Moreover, the risk of target vessel revascularization (TVR) after receiving DES was consistently lowered during long-term observation (all p< 0.01). In subgroup analysis, the use of everolimus-eluting stents (EES) was associated with reduced risk of stent thrombosis in STEMI patients (RR = 0.37, p=0.02).Conclusions:DES did not increase the risk of stent thrombosis in patients with STEMI compared with BMS. Moreover, the use of DES did lower long-term risk of repeat revascularization and might decrease the occurrence of reinfarction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The autonomic nervous system plays a central role in cardiovascular regulation; sympathetic activation occurs during myocardial ischemia. Objective: To assess the spectral analysis of heart rate variability during stent implantation, comparing the types of stent. Methods: This study assessed 61 patients (mean age, 64.0 years; 35 men) with ischemic heart disease and indication for stenting. Stent implantation was performed under Holter monitoring to record the spectral analysis of heart rate variability (Fourier transform), measuring the low-frequency (LF) and high-frequency (HF) components, and the LF/HF ratio before and during the procedure. Results: Bare-metal stent was implanted in 34 patients, while the others received drug-eluting stents. The right coronary artery was approached in 21 patients, the left anterior descending, in 28, and the circumflex, in 9. As compared with the pre-stenting period, all patients showed an increase in LF and HF during stent implantation (658 versus 185 ms2, p = 0.00; 322 versus 121, p = 0.00, respectively), with no change in LF/HF. During stent implantation, LF was 864 ms2 in patients with bare-metal stents, and 398 ms2 in those with drug-eluting stents (p = 0.00). The spectral analysis of heart rate variability showed no association with diabetes mellitus, family history, clinical presentation, beta-blockers, age, and vessel or its segment. Conclusions: Stent implantation resulted in concomitant sympathetic and vagal activations. Diabetes mellitus, use of beta-blockers, and the vessel approached showed no influence on the spectral analysis of heart rate variability. Sympathetic activation was lower during the implantation of drug-eluting stents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Drug-eluting stents have been used in daily practice since 2002, with the clear advantages of reducing the risk of target vessel revascularization and an impressive reduction in restenosis rate by 50%-70%. However, the occurrence of a late thrombosis can compromise long-term results, particularly if the risks of this event were sustained. In this context, a registry of clinical cases gains special value. Objective: To evaluate the efficacy and safety of drug-eluting stents in the real world. Methods: We report on the clinical findings and 8-year follow-up parameters of all patients that underwent percutaneous coronary intervention with a drug-eluting stent from January 2002 to April 2007. Drug-eluting stents were used in accordance with the clinical and interventional cardiologist decision and availability of the stent. Results: A total of 611 patients were included, and clinical follow-up of up to 8 years was obtained for 96.2% of the patients. Total mortality was 8.7% and nonfatal infarctions occurred in 4.3% of the cases. Target vessel revascularization occurred in 12.4% of the cases, and target lesion revascularization occurred in 8% of the cases. The rate of stent thrombosis was 2.1%. There were no new episodes of stent thrombosis after the fifth year of follow-up. Comparative subanalysis showed no outcome differences between the different types of stents used, including Cypher®, Taxus®, and Endeavor®. Conclusion: These findings indicate that drug-eluting stents remain safe and effective at very long-term follow-up. Patients in the "real world" may benefit from drug-eluting stenting with excellent, long-term results.