960 resultados para Ultrasound stimulated hydroxide


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes an efficient, fast, and reliable analytical methodology for mercury determination in urine samples using stripping chronopotentiometry at gold film electrodes. The samples were sonicated in the presence of concentrated HCl and H2O2 for 15 min in order to disrupt the organic ligands and release the mercury. Thirty samples can be treated over the optimized region of the ultrasonic bath. This sample preparation was enough to allow the accurate stripping chronopotentiometric determination of mercury in the treated samples. No background currents and no passivation of the gold film electrode due to the sample matrix were verified. The samples were also analyzed by cold vapour atomic absorption spectrometry (CV-AAS) and good agreement between the results was verified. The analysis of NIST SRM 2670 (Toxic Metals in Freeze-Dried Urine) also validated the proposed electroanalytical method. Finally, this method was applied for mercury evaluation in urine of workers exposed to hospital waste incinerators. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The acid and ultrasound catalyzed hydrolysis of solventless TEOS-water mixtures are studied, as a function of the initial additions of ethanol to the mixtures, by means of flux calorimetry measurements. A device was specially designed for this purpose. Under acid conditions, our proposed method has been able to resolve hydrolysis from other condensation reactions, by detecting the exothermal hydrolysis reaction heat. The process has been explained by a dissolution and reaction mechanism. Ultrasound forces the dissolution process to start the reaction. The alcohol produced in the reaction helps the dissolution process to further enhance the hydrolysis. Initial amounts of pure ethanol added to the mixtures shorten the start time of the reaction, due to an additional effect of dissolution, and diminish the reaction rate, as a result of the solvent dilution effect. Our dissolution and reaction mechanism modeling describes the main points arising from the experimental data and yields k(H) = 0.24 M(-1) min(-1) for the second-order hydrolysis rate constant at 39 degrees C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pure and mixed tetramethoxysilane (TMOS) and tetraethoxysilane (TEOS) were hydrolyzed at 35 degrees C, using oxalic acid as a catalyst and ultrasound stimulation. The hydrolysis reaction was carried out in a specially designed device, in which a heat flow steady state, between the ultrasound source and an external thermostatic bath, was maintained, in the absence of reactions. The exothermic hydrolysis causes a time dependent thermal peak. An induction time is apparent in pure TEOS before the hydrolysis peaks starts, which has been explained by the initial immiscibility gap of the TEOS-water system. The induction time was found to be approximately of the same magnitude as in the HCl catalyzed hydrolysis, in spite of the uncertainty accompanying the peak definition. No induction period is apparent in pure TMOS, so that the hydrolysis starts with its maximum rate. Two independent thermal peaks in the mixed TMOS-TEOS samples were found, both associated to the respective hydrolyses of the pure component. The induction time for the TEOS hydrolysis is decreased as more alcohol (and silanol) is produced in the earlier TMOS hydrolysis. This effect is explained by improvement of homogenization by alcohol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an approximate universality displayed by thermally stimulated depolarization currents ruled by stretched exponential relaxations when properly re-scaled. A visually perfect universality occurs especially when the energy and the heating rate are varied. It becomes somewhat poorer when the frequency factor or the stretched exponent changes. Empirical relations between the half widths and other pertinent parameters are given.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous in vitro studies have demonstrated zinc (Zn++) inhibition of basal and of potassium (K+) or thyrotropin-releasing hormone (TRH)-stimulated prolactin (PRL) secretion, in a selective, reversible, and dose-dependent manner. Thus, Zn++ may regulate physiologically pituitary PRL secretion. Furthermore, studies with patients with uremia, cirrhosis or prolactinoma, have shown the coexistence of hypozincemia and hyperprolactinemia and zinc supplementation did not correct hyperprolactinemia in these patients. In normal individuals Zn++ administration produced controversial results on PRL secretion. Here, we investigated whether zinc administration affects TRH-stimulated PRL in healthy men. We found that Zn++ administration does not change the TRH-stimulated PRL. Therefore, in normal conditions, Zn++ does not inhibit TRH-stimulated prolactinemia. In addition, we found that acute increases of blood PRL and TRH do not alter blood Zn++ levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The acid hydrolysis under ultrasound stimulation of solventless tetraethoxysilane(TEOS)-water mixtures was studied at 40 degrees C, by means of a heat flux calorimetric method, as a function of the initial water/TEOS molar ratio (r) ranging from 2 to 10. The method is based on the time record of the exothermic heat peak of hydrolysis, arising after an induction time under ultrasound stimulation, which is a measure of the reaction rate. The hydrolysed quantity was found to be approximately independent of the water/TEOS molar ratio, even for r < 4. Polycondensation reaction takes place mainly for low water/TEOS molar ratio in order to supply water to allow almost complete hydrolysis. The overall process of dissolution and hydrolysis has reasonably been described by a previous modelling. The dissolution process of water in TEOS, under ultrasound stimulation and acid conditions, was found to be rather dependent of the alcohol produced in the hydrolysis reaction instead of the initial water quantity present in the mixture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To compare the periapical repair of teeth with periapical lesion following root canal treatment by using a calcium hydroxide-based intracanal dressing for several time periods or filling in a single visit.Study design. After induction of periapical lesions in 4 dogs, the root canals were prepared using 5.25% sodium hypochlorite for irrigation, and animals were separated into 4 experimental groups; in group I, root canals were filled in a single session; in groups II, III, and IV, a calcium hydroxide-based dressing was kept in place for 15, 30, or 180 days, respectively. Root canals from groups I, II, and III were filled with gutta-percha cones and AH Plus sealer. After 180 days, animals were killed and histological sections were stained with hematoxylin-eosin to evaluate periapical repair.Results. Periapical repair was better in groups II, III, and IV (intracanal dressing) compared with group I (single session; P <.05).Conclusion. The use of a calcium hydroxide-based intracanal dressing was important for periapical repair in teeth with periapical lesion. Dressing with calcium hydroxide paste results in better periapical repair than when the root canal is filled in a single-session treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dopamine (DA) and zinc (Zn++) share common mechanisms in their inhibition of prolactin (PRL) secretion. Both substances are present in the same brain areas, where Zn++ is released together with DA, suggesting a modulatory effect of Zn++ on dopaminergic receptors. The aim of the present study was to evaluate the effect of Zn supplementation on basal and PRL secretion stimulated by metoclopramide (MCP), a dopaminergic antagonist. Seven healthy men were evaluated in controlled study, where MCP (5 mg) was given intravenously, before and after 3 months of oral Zn++ (25 mg) administration. Our results indicate that chronic Zn++ administration does not change basal or MCP-stimulated plasma PRL secretion suggesting that, in humans, Zn++ does not interfere on PRL secretion mediated through dopaminergic receptors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simplified dissolution and reaction modeling was employed to study the hydrolysis of heterogeneous tetraethoxysilane (TEOS)-water-HCl mixtures under ultrasound stimulation. The nominal pH was changed from 0.8 to 2.0. The acid specific hydrolysis rate constant was determined as k = 6.1 mol(-1) 1 min(-1) [H+](-1) at 39 degreesC, in good agreement with the literature. Along the heterogeneous step of the reaction, the ultrasound maintains an additional quantity of water under a virtual state of dissolution besides the water dissolved due to the homogenizing effect of the alcohol produced in the reaction. The forced virtually dissolved water is probably represented by water at the TEOS-water interface during the heterogeneous step of the reaction. The mean radius of the heterogeneity represented by water dispersed in TEOS phase, while hydrolysis has not started yet, was evaluated as about 290 A. The HCl concentration accordingly increases the hydrolysis rate constant but its fundamental role on the immiscibility gap of the TEOS-water-ethanol system has not been unequivocally established. (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A regimen of progesterone plus estradiol (P&E) was used as a standard for ovarian synchronization to test the efficacy and evaluate the commercial application of ultrasound-guided follicle ablation as a non-steroidal alternative for ovulation synchronization in mares. Recipient mares at a private embryo transfer facility were at unknown stages of the estrous cycle at the start of the experiment on Day 1 when they were randomly assigned to an ablation group (n = 18-21 mares) or to a ME group (n = 20-21 mares). In the ablation group, mares were lightly sedated and all follicles > 10 mm were removed by transvaginal ultrasound-guided follicle aspiration. In the ME group, a combination of progesterone (150 mg) plus estradiol (10 mg) prepared in safflower oil was given daily (im) for 10 d. Two doses of prostaglandin FZ, (PGF, 10 mg/dose, im) were given 12 h apart on Day 5 in the ablation group, or a single dose on Day 10 in the ME group. Human chorionic gonadotropin (hCG, 2500 IU/mare, im) was given at a fixed time, 6 and 10 d after PGF treatment in the ablation and ME groups, respectively, with the expectation of a follicle > 30 mm at the time of treatment. In both the ablation and P&E groups, transrectal ultrasonography was done at the start of the study (Day 1) and again on the day of hCG treatment and daily thereafter to determine the presence of a CL, measure diameter of the largest follicle and detect ovulation. The mean interval from the start of the study and from PGF treatment to ovulation was shorter (P < 0.0001) in the ablation group (13.7 and 9.7 d, respectively) compared to the P&E group (22.3 and 13.2 d, respectively). Following fixed-day treatment with hCG after PGF treatment, the degree of ovulation synchronization was not different (P > 0.05) between the ablation and P&E groups within a 2-d (56 and 70%) or 4-d (83% and 90%) period. Although ultrasound-guided follicle ablation may not be practical in all circumstances, it excluded the conventional 10-d regimen of progesterone and estradiol and was considered an efficacious and feasible, non-steroidal alternative for ovulation synchronization in mares during the estrous cycle. (C 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Twenty eight Mediterranean buffaloes bulls were scanned with real-time ultrasound (RTU), slaughtered, and fabricated into retail cuts to determine the potential for ultrasound measures to predict carcass retail yield. Ultrasound measures of fat thickness, ribeye area and rump fat thickness were recorded three to five days prior to slaughter. Carcass measurements were taken, and one side of each carcass was fabricated into retail cuts. Stepwise regression analysis was used to compare possible models for prediction of either kilograms or percent retail product from carcass mesaurements and ultrasound measures. Results indicate that possible prediction models for percent or kilograms of retail products using RTU measures were similar in their predictive power and accuracy when compared to models derived from carcass measurements. Both fat thickness and ribeye area were over-predicted when measured ultrasonically compared to measurements taken on the carcass in the cooler. The mean absolute differences for both traits are larger than the mean differences, indicating that some images were interpreted to be larger and some smaller than actual carcass measurements. Ultrasound measurements of REA and FT had positive correlations with carcass measures of the same traits (r=.96 for REA and r=.99 for FT). Standard errors of prediction currently are being used as the standard to certify ultrasound technicians for accuracy. Regression equations using live weight (LW), rib eye area (REAU) and subcutaneous fat thickness (FTU) between 12(th) and 13 (th) ribs and also over the biceps femoris muscle (FTP8) by ultrasound explained 95% of the variation in the hot carcass weight when measure immediately before slaughter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to estimate the correlations among measurements taken in vivo with ultrasound equipment with some carcass traits measured after slaughter. Twenty eight Mediterranean bulls, with average shrunk body weight of 330 kg and 14 months of age, were fed by 120 days with high concentrate diets. The shrunk body weight, the ribeye area (REAU), the back fat thickness (FTU) over the Longissimus dorsi muscle between 12(a) and 13(a) ribs and rump fat (EGP8U), were measured at 28 days intervals. Real-time ultrasound equipment Piemedical Scanner 200 VET, with 18 cm linear array transducer was utilized. After the slaughter, the hot carcass weight (PCQ) and the kidney, pelvic and inguinal fat (GRPI) were weighted and the dressing percentage (DP) calculated. After 24 hours of cooling the ribeye area (REAC), backfat thickness (FTC) and rump fat (EGP8C) were measured. Both the REAC, FTC and EGP8C were underestimated by ultrasound measurements. The Pearson correlation coefficients for ribeye area, backfat thickness and rump fat measured in the carcass and with ultrasound, were 0.96, 0.99 and 0.91, respectively. The coefficient between DP and REAU was 0.47; 0.45 between DP and REAC, 0.56 between DP and FTU and 0.58 between DP and FTC. DP presented a 0.59 correlation coefficient with EGP8U. The Spearman correlation was estimated between REAU and REAC, FTU and FTC, EGP8U and EGP8C, and the values were 0.96, 0.99 and 0.91,respectively. The ultrasound measures could be used to estimate carcass traits in buffaloes with good accuracy.