800 resultados para URBAN LIBRARY JOURNAL
Resumo:
The aim of this paper is to illustrate the impact of urban wind environments when assessing the availability of natural ventilation. A numerical study of urban airflow for a complex of five building blocks located at the University of Reading, UK is presented. The computational fluid dynamics software package ANSYS was used to simulate six typical cases of urban wind environments and the potential for natural ventilation assessed. The study highlights the impact of three typical architectural forms (street canyons, semi-enclosures and courtyards) on the local wind environment. Simulation results have also been compared with experimental data collected from six locations on the building complex. The study demonstrates that ventilation strategies formed using regional weather data, may have a propensity to over-estimate the potential for natural ventilation and cooling, due to the impact of urban form which creates a unique microclimate. Characteristics of urban wind flow patterns are presented as a guideline and can be used to assess the design and performance of natural or hybrid ventilation and the opportunity for passive cooling.
Resumo:
In the first part of this article, we introduced a new urban surface scheme, the Met Office – Reading Urban Surface Exchange Scheme (MORUSES), into the Met Office Unified Model (MetUM) and compared its impact on the surface fluxes with respect to the current urban scheme. In this second part, we aim to analyze further the reasons behind the differences. This analysis is conducted by a comparison of the performance of the two schemes against observations and against a third model, the Single Column Reading Urban model (SCRUM). The key differences between the three models lie in how each model incorporates the heat stored in the urban fabric and how the surface-energy balance is coupled to the underlying substrate. The comparison of the models with observations from Mexico City reveals that the performance of MORUSES is improved if roof insulation is included by minimizing the roof thickness. A comparison of MORUSES and SCRUM reveals that, once insulation is included within MORUSES, these two models perform equally well against the observations overall, but that there are differences in the details of the simulations at the roof and canyon level. These differences are attributed to the different representations of the heat-storage term, specifically differences in the dominant frequencies captured by the urban canopy and substrate, between the models. These results strongly suggest a need for an urban model intercomparison exercise. Copyright © 2010 Royal Meteorological Society and Crown Copyright
Resumo:
This paper describes the formulation of a new urban scheme, MORUSES (Met Office–Reading Urban Surface Exchange Scheme) for use in the Met Office Unified Model. The implementation of the new scheme ensures that (1) the new scheme offers more flexibility in the parametrization of the building properties, and hence provides a more realistic representation of the fluxes; (2) the bulk outputs are in satisfactory agreement with previous observational studies; and (3) the impact of the new scheme on the energy balance fluxes is similar to the impact of the current urban scheme when set up to mimic it. As well as having a better physical basis, MORUSES also gains in flexibility in applications and adaptations to different urban materials as well as urban planning. The new scheme represents the urban area as a composition of two tiles, a canyon and a roof, using a simple 2D geometry. Sensitivity analysis to canyon geometry and thickness of the roof canopy emphasizes the gain in flexibility captured by the new scheme. Copyright © 2010 Royal Meteorological Society and Crown Copyright
Resumo:
Carbon monoxide (CO) concentration data from 1999–2006, monitored at 5 different pollution stations in a high-rise mega city (Hong Kong), were collected and investigated. The spatio-temporal characteristics of urban CO concentration profiles were obtained. A new approach was put forward to examine the relationship between urban CO concentration and different wind flow patterns. Rather than relying on the meteorological data from a single weather station, usually adopted in previous studies, four weather stations on the boundary of Hong Kong territory were used in the present study so as to identify 16 different wind flow patterns, among which a typical urban heat island circulation (UHIC) can be distinguished. Higher concentrations were observed to be associated with the flow pattern of an inflow from Lau Fau Shan (LFS) station which is located in the northwest of Hong Kong. This suggests that the ability of dilution for north-to-west wind is relatively weak due to the pollutants carried from outside Hong Kong. The effectiveness of wind speed on the alleviation of urban concentration is dependent on the initial concentration of the approaching wind. The increase of wind speed of north-to-west wind from 0 m/s to 6 m/s has little effect on the reduction of urban CO concentration, especially on the non-roadside stations. By contrast, for the southerly marine wind, pollution concentration decreases sharply with an increase in the wind speed. It was also found that urban heat island circulation (UHIC) is conducive of the accumulation of pollutants, especially at night. There exists a positive correlation between CO concentration and UHI intensity. This correlation is much stronger at night compared to during the day. Keywords: urban pollution monitoring, urban ventilation pattern, urban heat island circulation, mega city
Resumo:
In addition to the expression of recombinant proteins, baculoviruses have been developed as a platform for the display of complex eukaryotic proteins on the surface of virus particles or infected insect cells. Surface display has been used extensively for antigen presentation and targeted gene delivery but is also a candidate for the display of protein libraries for molecular screening. However, although baculovirus gene libraries can be efficiently expressed and displayed on the surface of insect cells, target gene selection is inefficient probably due to super-infection which gives rise to cells expressing more than one protein. In this report baculovirus superinfection of Sf9 cells has been investigated by the use of two recombinant multiple nucleopolyhedrovirus carrying green or red fluorescent proteins under the control of both early and late promoters (vAcBacGFP and vAcBacDsRed). The reporter gene expression was detected 8 hours after the infection of vAcBacGFP and cells in early and late phases of infection could be distinguished by the fluorescence intensity of the expressed protein. Simultaneous infection with vAcBacGFP and vAcBacDsRed viruses each at 0.5 MOI resulted in 80% of infected cells coexpressing the two fluorescent proteins at 48 hours post infection (hpi), and subsequent infection with the two viruses resulted in similar co-infection rate. Most Sf9 cells were re-infectable within the first several hours post infection, but the reinfection rate then decreased to a very low level by 16 hpi. Our data demonstrate that Sf9 cells were easily super-infectable during baculovirus infection, and super-infection could occur simultaneously at the time of the primary infection or subsequently during secondary infection by progeny viruses. The efficiency of super-infection may explain the difficulties of baculovirus display library screening but would benefit the production of complex proteins requiring co-expression of multiple polypeptides.
Resumo:
Four established mature tree species (Aesculus hippocastanum L., Betula pendula Roth., Primus avium L. and Quercus rohur L.) commonly planted in UK urban landscapes were subjected to soil injections of the carbohydrate sucrose at 25, 50 and 70g per litre of water. Fine root dry weight was recorded at month 5 following soil injections. Soil injections of sucrose significantly increased fine root dry weight compared to controls, however; growth responses were influenced by species and the concentration of sucrose applied. Results indicate soil injections of sucrose ≥ 50g litre of water may be able to improve root growth of established mature trees. Such a response is desirable as root damage following construction is a frequent problem encountered by established trees growing in UK towns and cities.
Resumo:
Four commercially available, biostimulants sold under the trade names ‘Generate’, ‘Crop Set’, ‘Fulcrum’ and ‘Redicrop 2000’ were applied either as a root drench or foliar spray to three transplant-sensitive tree species, red oak(Quercus rubra), birch(Betula pendula) and beech (Fagus sylvatica) post transplanting. The short and long-term efficacy of the biostimulants on growth was quantified by recording root and shoot vigour at week 8 and 20. In addition, improvements in tree vitality were assessed by measurement of a chlorophyll a performance index based on leaf chlorophyll fluorescence emissions. Irrespective of species, no significant effect of mode of application (foliar spray versus root drench) was recorded on growth and vitality. The biostimulants Generate and Fulcrum increased growth of all three tree species. No significant effects on growth and chlorophyll fluorescence of birch and beech were recorded following applications of the biostimulants Crop Set and Redicrop 2000, however, significant increase in growth of red oak was recorded. Only the biostimulant Generate increased chlorophyll fluorescence values of all test species. Results show use of biostimulants can improve root and shoot vigour following transplanting. However, selection of an appropriate biostimulant is critical as effects on growth and vitality can vary widely between tree species possibly as a result of the differing active ingredient used in the formulation of the product.
Resumo:
In a Report for the Society of Bookmen in 1928, British publishers estimated that between a quarter to two thirds of all the books they published went to four circulating libraries: Boots, Smith’s, Mudie’s, and The Times bookclub. This essay examines the literary impact of one of the largest of these, Boots Book-lovers’ Library (1899-66), which by 1935 had around 400 libraries attached to their high-street pharmacies catering for the tastes of over one million subscribers a year. Compared to the wealth of studies examining the influence of the library market in the Victorian period, the significance of the subscription libraries as key distributors of fiction in the twentieth century is not well known. But private libraries expanded rapidly in the early twentieth century to cater for what Sidney Dark termed a ‘new reading public’, and records in publishers’ archives indicate that authors routinely adapted their unpublished manuscripts in order to meet the perceived demands of this library reader. This article examines the impact of the Boots Book-lovers’ Library market on authors’ practices of writing and revision, and on literary marketing and censorship. It focuses in particular on the author James Hanley (1897-1985), using unpublished correspondence in the Chatto & Windus archive at the University of Reading to demonstrate how the publisher’s sense of the tastes and expectations of the Boots library reader influenced the editorial process.
Resumo:
A better understanding of links between the properties of the urban environment and the exchange to the atmosphere is central to a wide range of applications. The numerous measurements of surface energy balance data in urban areas enable intercomparison of observed fluxes from distinct environments. This study analyzes a large database in two new ways. First, instead of normalizing fluxes using net all-wave radiation only the incoming radiative fluxes are used, to remove the surface attributes from the denominator. Second, because data are now available year-round, indices are developed to characterize the fraction of the surface (built; vegetation) actively engaged in energy exchanges. These account for shading patterns within city streets and seasonal changes in vegetation phenology; their impact on the partitioning of the incoming radiation is analyzed. Data from 19 sites in North America, Europe, Africa, and Asia (including 6-yr-long observation campaigns) are used to derive generalized surface–flux relations. The midday-period outgoing radiative fraction decreases with an increasing total active surface index, the stored energy fraction increases with an active built index, and the latent heat fraction increases with an active vegetated index. Parameterizations of these energy exchange ratios as a function of the surface indices [i.e., the Flux Ratio–Active Index Surface Exchange (FRAISE) scheme] are developed. These are used to define four urban zones that characterize energy partitioning on the basis of their active surface indices. An independent evaluation of FRAISE, using three additional sites from the Basel Urban Boundary Layer Experiment (BUBBLE), yields accurate predictions of the midday flux partitioning at each location.
Resumo:
The large scale urban consumption of energy (LUCY) model simulates all components of anthropogenic heat flux (QF) from the global to individual city scale at 2.5 × 2.5 arc-minute resolution. This includes a database of different working patterns and public holidays, vehicle use and energy consumption in each country. The databases can be edited to include specific diurnal and seasonal vehicle and energy consumption patterns, local holidays and flows of people within a city. If better information about individual cities is available within this (open-source) database, then the accuracy of this model can only improve, to provide the community data from global-scale climate modelling or the individual city scale in the future. The results show that QF varied widely through the year, through the day, between countries and urban areas. An assessment of the heat emissions estimated revealed that they are reasonably close to those produced by a global model and a number of small-scale city models, so results from LUCY can be used with a degree of confidence. From LUCY, the global mean urban QF has a diurnal range of 0.7–3.6 W m−2, and is greater on weekdays than weekends. The heat release from building is the largest contributor (89–96%), to heat emissions globally. Differences between months are greatest in the middle of the day (up to 1 W m−2 at 1 pm). December to February, the coldest months in the Northern Hemisphere, have the highest heat emissions. July and August are at the higher end. The least QF is emitted in May. The highest individual grid cell heat fluxes in urban areas were located in New York (577), Paris (261.5), Tokyo (178), San Francisco (173.6), Vancouver (119) and London (106.7). Copyright © 2010 Royal Meteorological Society
Resumo:
For an increasing number of applications, mesoscale modelling systems now aim to better represent urban areas. The complexity of processes resolved by urban parametrization schemes varies with the application. The concept of fitness-for-purpose is therefore critical for both the choice of parametrizations and the way in which the scheme should be evaluated. A systematic and objective model response analysis procedure (Multiobjective Shuffled Complex Evolution Metropolis (MOSCEM) algorithm) is used to assess the fitness of the single-layer urban canopy parametrization implemented in the Weather Research and Forecasting (WRF) model. The scheme is evaluated regarding its ability to simulate observed surface energy fluxes and the sensitivity to input parameters. Recent amendments are described, focussing on features which improve its applicability to numerical weather prediction, such as a reduced and physically more meaningful list of input parameters. The study shows a high sensitivity of the scheme to parameters characterizing roof properties in contrast to a low response to road-related ones. Problems in partitioning of energy between turbulent sensible and latent heat fluxes are also emphasized. Some initial guidelines to prioritize efforts to obtain urban land-cover class characteristics in WRF are provided. Copyright © 2010 Royal Meteorological Society and Crown Copyright.
Resumo:
An urban energy and water balance model is presented which uses a small number of commonly measured meteorological variables and information about the surface cover. Rates of evaporation-interception for a single layer with multiple surface types (paved, buildings, coniferous trees and/or shrubs, deciduous trees and/or shrubs, irrigated grass, non-irrigated grass and water) are calculated. Below each surface type, except water, there is a single soil layer. At each time step the moisture state of each surface is calculated. Horizontal water movements at the surface and in the soil are incorporated. Particular attention is given to the surface conductance used to model evaporation and its parameters. The model is tested against direct flux measurements carried out over a number of years in Vancouver, Canada and Los Angeles, USA. At all measurement sites the model is able to simulate the net all-wave radiation and turbulent sensible and latent heat well (RMSE = 25–47 W m−2, 30–64 and 20–56 W m−2, respectively). The model reproduces the diurnal cycle of the turbulent fluxes but typically underestimates latent heat flux and overestimates sensible heat flux in the day time. The model tracks measured surface wetness and simulates the variations in soil moisture content. It is able to respond correctly to short-term events as well as annual changes. The largest uncertainty relates to the determination of surface conductance. The model has the potential be used for multiple applications; for example, to predict effects of regulation on urban water use, landscaping and planning scenarios, or to assess climate mitigation strategies.