981 resultados para Tomography, computed axial


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magnetic resonance imaging (MRI) relies on the physical properties of unpaired protons in tissues to generate images. Unpaired protons behave like tiny bar magnets and will align themselves in a magnetic field. Radiofrequency pulses will excite these aligned protons to higher energy states. As they return to their original state, they will release this energy as radio waves. The frequency of the radio waves depends on the local magnetic field and by varying this over a subject, it is possible to build the images we are familiar with. In general, MRI has not been sufficiently sensitive or specific in the assessment of diffuse liver disease for clinical use. However, because of the specific characteristics of fat and iron, it may be useful in the assessment of hepatic steatosis and iron overload. Magnetic resonance imaging is useful in the assessment of focal liver disease, particularly in conjunction with contrast agents. Haemangiomas have a characteristic bright appearance on T-2 weighted images because of the slow flowing blood in dilated sinusoids. Focal nodular hyperplasia (FNH) has a homogenous appearance, and enhances early in the arterial phase after gadolinium injection, while the central scar typically enhances late. Hepatic adenomas have a more heterogenous appearance and also enhance in the arterial phase, but less briskly than FNH. Hepatocellular carcinoma is similar to an adenoma, but typically occurs in a cirrhotic liver and has earlier washout of contrast. The appearance of metastases depends on the underlying primary malignancy. Overall, MRI appears more sensitive and specific than computed tomography with contrast for the detection and evaluation of malignant lesions. (C) 2000 Blackwell Science Asia Pty Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. A decline in muscle mass and muscle strength characterizes normal aging. As clinical and animal studies show it relationship between higher cytokine levels and low muscle mass, the aim of this study was to investigate whether markers, of inflammation are associated with muscle mass and strength in well-functioning elderly persons. Methods. We Used baseline data (1997-1998) of the Health, Aging, and Body Composition (Health ABC) Study on 3075 black and white men and women aged 70-79 years. Midthigh muscle cross-sectional area (computed tomography), appendicular muscle mass (dual-energy x-ray ab absorptiometry). isokinetic knee extensor strength (KinCom). and isometric inip strength were measured. plasma levels of interleukin-6 (IL-6) and tumor necrosis factor-alpha (TNF-alpha) were assessed by enzyme-linked immunosorbent assay (ELISA). Results. Higher cytokine levels were generally associated with lower muscle mass and lower muscle strength. The most consistent relationship across the gender and race groups was observed for IL-6 and grip strength: per SD increase in IL-6, grip strength was 1.1 to 2.4 kg lower (p < .05) after adjustment for age, clinic Site. health status, medications, physical activity. smoking. height. and body fat. Ail overall measure of elevated cytokine level was created by combining the levels of IL-6 and TNF-alpha. With the exception of white men, elderly persons having high levels of IL-6 (> 1.80 pg/ml) as well as high levels of TNF-alpha (> 3.20 pg/ml) had a smaller muscle area, less appendicular mass. a lower knee extensor strength. and a lower grip strength compared to those with low levels of both cytokines. Conclusions. Higher plasma concentrations of IL-6 and TNF-alpha are associated with lower muscle mass and lower muscle strength in well-functioning older men and women. Higher cytokine levels. as often observed in healthy older persons. may contribute to the loss Of muscle mass and strength that accompanies aging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method for the evaluation of radiotherapy 3D polymer gel dosimeters has been developed using ultrasound to assess the significant structural changes that occur following irradiation of the dosimeters. The ultrasonic parameters of acoustic speed of propagation, attenuation and transmitted signal intensity were measured as a function of absorbed radiation dose. The dose sensitivities for each parameter were determined as 1.8 x 10(-4) s m(-1) Gy(-1), 3.9 dB m(-1) Gy(-1) and 3.2 V-1 Gy(-1) respectively. All parameters displayed a strong variation with absorbed dose that continued beyond absorbed doses of 15 Gy. The ultrasonic measurements demonstrated a significantly larger dynamic range in dose response curves than that achieved with previously published magnetic resonance imaging (MRI) dose response data. It is concluded that ultrasound shows great potential as a technique for the evaluation of polymer gel dosimeters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Off-resonance RF pre-saturation was used to obtain contrast in MRI images of polymer gel dosimeters irradiated to doses up to 50 Gy. Two different polymer gel dosimeters composed of 2-hydroxyethyl-acryl ate or methacrylic acid monomers mixed with N, N'-methylene-bisacrylamide (BIS), dispersed in an aqueous gelatin matrix were evaluated. Radiation-induced polymerization of the co-monomers generates a fast-relaxing insoluble polymer. Saturation of the polymer using off-resonance Gaussian RF pulses prior to a spin-echo read-out with a short echo time leads to contrast that is dependent on the absorbed dose. This contrast is attributed to magnetization transfer (MT) between free water and the polymer, and direct saturation of water was found to be negligible under the prevailing experimental conditions. The usefulness of MT imaging was assessed by computing the dose resolution obtained with this technique. We found a low value of dose resolution over a wide range of doses could be obtained with a single experiment. This is an advantage over multiple spin echo (MSE) experiments using a single echo spacing where an optimal dose resolution is achieved over only very limited ranges of doses. The results suggest MT imaging protocols may be developed into a useful tool for polymer gel dosimetry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Concerns exist regarding the effect of radiation dose from paediatric pelvic CT scans and the potential later risk of radiation-induced neoplasm and teratogenic outcomes in these patients. Objective: To assess the diagnostic quality of CT images of the paediatric pelvis using either reduced mAs or increased pitch compared with standard settings. Materials and methods: A prospective study of pelvic CT scans of 105 paediatric patients was performed using one of three protocols: (1) 31 at a standard protocol of 200 mA with rotation time of 0.75 s at 120 kVp and a pitch factor approximating 1.4; (2) 31 at increased pitch factor approaching 2 and 200 mA; and (3) 43 at a reduced setting of 100 mA and a pitch factor of 1.4. All other settings remained the same in all three groups. Image quality was assessed by radiologists blinded to the protocol used in each scan. Results: No significant difference was found between the quality of images acquired at standard settings and those acquired at half the standard mAs. The use of increased pitch factor resulted in a higher proportion of poor images. Conclusions: Images acquired at 120 kVp using 75 mAs are equivalent in diagnostic quality to those acquired at 150 mAs. Reduced settings can provide useful imaging of the paediatric pelvis and should be considered as a standard protocol in these situations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the kinematics and muscle activity associated with the standard sit-up, as a first step in the investigation of complex motor coordination. Eight normal human subjects lay on a force table and performed at least 15 sit-ups, with the arms across the chest and the legs straight and unconstrained. Several subjects also performed sit-ups with an additional weight added to the head. Support surface forces were recorded to calculate the location of the center of pressure and center of gravity; conventional motion analysis was used to measure segmental positions; and surface EMG was recorded from eight muscles. While the sit-up consists of two serial components, 'trunk curling' and 'footward pelvic rotation', it can be further subdivided into five phases, based on the kinematics. Phases I and II comprise trunk curling. Phase I consists of neck and upper trunk flexion, and phase II consists of lumbar trunk lifting. Phase II corresponds to the point of peak muscle contraction and maximum postural instability, the 'critical point' of the sit-up. Phases III-V comprise footward pelvic rotation. Phase III begins with pelvic rotation towards the feet. phase W with leg lowering, and phase V with contact between the legs and the support surface. The overall pattern of muscle activity was complex with times of EMG onset, peak activity, offset, and duration differing for different muscles. This complex pattern changed qualitatively from one phase to the next, suggesting that the roles of different muscles and, as a consequence, the overall form of coordination, change during the sit-up. (C) 2003 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Direct and simultaneous observation of root growth and plant water uptake is difficult because soils are opaque. X-ray imaging techniques such as projection radiography or Computer Tomography (CT) offer a partial alternative to such limitations. Nevertheless, there is a trade-off between resolution, large field-of-view and 3-dimensionality: With the current state of the technology, it is possible to have any two. In this study, we used X-ray transmission through thin-slab systems to monitor transient saturation fields that develop around roots as plants grow. Although restricted to 2-dimensions, this approach offers a large field-of-view together with high spatial and dynamic resolutions. To illustrate the potential of this technology, we grew peas in 1 cm thick containers filled with soil and imaged them at regular intervals. The dynamics of both the root growth and the water content field that developed around the roots could be conveniently monitored. Compared to other techniques such as X-ray CT, our system is relatively inexpensive and easy to implement. It can potentially be applied to study many agronomic problems, such as issues related to the impact of soil constraints (physical, chemical or biological) on root development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to exemplify the specific contribution of both two- and three-dimensional (31)) X-ray computed tomography to characterise earthworm burrow systems. To achieve this purpose we used 3D mathematical morphology operators to characterise burrow systems resulting from the activity of an anecic (Aporrectodea noctunia), and an endogeic species (Allolobophora chlorotica), when both species were introduced either separately or together into artificial soil cores. Images of these soil cores were obtained using a medical X-ray tomography scanner. Three-dimensional reconstructions of burrow systems were obtained using a specifically developed segmentation algorithm. To study the differences between burrow systems, a set of classical tools of mathematical morphology (granulometries) were used. So-called granulometries based on different structuring elements clearly separated the different burrow systems. They enabled us to show that burrows made by the anecic species were fatter, longer, more vertical, more continuous but less sinuous than burrows of the endogeic species. The granulometry transform of the soil matrix showed that burrows made by A. nocturna were more evenly distributed than those of A. chlorotica. Although a good discrimination was possible when only one species was introduced into the soil cores, it was not possible to separate burrows of the two species from each other in cases where species were introduced into the same soil core. This limitation, partly due to the insufficient spatial resolution of the medical scanner, precluded the use of the morphological operators to study putative interactions between the two species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exponential and sigmoidal functions have been suggested to describe the bulk density profiles of crusts. The present work aims to evaluate these conceptual models using high resolution X-radiography. Repacked seedbeds from two soil materials, air-dried or prewetted by capillary rise, were subjected to simulated rain, which resulted in three types of structural crusts, namely, slaking, infilling, and coalescing. Bulk density distributions with depth were generated using high-resolution (70 mum), calibrated X-ray images of slices from the resin-impregnated crusted seedbeds. The bulk density decreased progressively with depth, which supports the suggestion that a crust should be considered as a nonuniform layer. For the slaking and the coalescing crusts, the exponential function underestimated the strong change in bulk density across the morphologically defined transition between the crust and the underlying material; the sigmoidal function provided a better description. Neither of these crust models effectively described the shape of the bulk density profiles through the whole seedbed. Below the infilling and slaking crusts, bulk density increased linearly with depth as a result of slumping. In the coalescing crusted seedbed, the whole seedbed uniformly collapsed and most of the bulk density change within the crust could be ascribed to slumping (0.33 g cm(-3)) rather than to crusting (0.12 g cm(-3)). Finally, (i) X-radiography appears as a unique tool to generate high resolution bulk density profiles and (ii) in structural crusts, bulk density profiles could be modeled using the existing exponential and sigmoidal crusting models, provided a slumping model would be coupled.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate complete characterization of a two-qubit entangling process-a linear optics controlled-NOT gate operating with coincident detection-by quantum process tomography. We use a maximum-likelihood estimation to convert the experimental data into a physical process matrix. The process matrix allows an accurate prediction of the operation of the gate for arbitrary input states and a calculation of gate performance measures such as the average gate fidelity, average purity, and entangling capability of our gate, which are 0.90, 0.83, and 0.73, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on a self-similar array model, we systematically investigated the axial Young's modulus (Y-axis) of single-walled carbon nanotube (SWNT) arrays with diameters from nanometer to meter scales by an analytical approach. The results show that the Y-axis of SWNT arrays decreases dramatically with the increases of their hierarchy number (s) and is not sensitive to the specific size and constitution when s is the same, and the specific Young's modulus Y-axis(s) is independent of the packing configuration of SWNTs. Our calculations also show that the Y-axis of SWNT arrays with diameters of several micrometers is close to that of commercial high performance carbon fibers (CFs), but the Y-axis(s) of SWNT arrays is much better than that of high performance CFs. (C) 2005 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The relationship between saddle nose deformity (SND) in Wegener`s granulomatosis (WG) and other clinical features, including retro-orbital mass formation (ROM), has been poor described. Therefore, this relationship was analyzed retrospectively from 2000 to 2010. Patients and Methods: Eighteen consecutive WG patients with SND diagnosed by computed tomography were matched to 36 WG patients without SND (control group) for gender, age at WG diagnosis and disease duration. Results: No difference was found between the two groups in relation to WG type (limited and systemic forms), ethnicity, laboratory features, constitutional symptoms or clinical manifestations, including upper respiratory tract, and treatment, except for ROM (33.3 vs. 2.8% in SND(+) and SND(-) groups, respectively; p=0.004) and subglottic stenosis (22.2 vs. 2.8%; p=0.038). However, on multivariate analysis, only ROM (OR 17.15; 95% CI 1.11-265.52) was statistically associated to SND. In addition, in more than half of the cases, SND manifested prior to ROM. Conclusions: Results of this prospective analysis showed that SND was strongly associated to ROM in WG. Since early diagnosis and aggressive treatment of orbital involvement could lead to better prognosis, the presence of SND warrants additional vigilance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: We tested the hypothesis that the universal application of myocardial scanning with single-photon emission computed tomography (SPECT) would result in better risk stratification in renal transplant candidates (RTC) compared with SPECT being restricted to patients who, in addition to renal disease, had other clinical risk factors. Methods: RTCs (n=363) underwent SPECT and clinical risk stratification according to the American Society of Transplantation (AST) algorithm and were followed up until a major adverse cardiovascular event (MACE) or death. Results: Of the 363 patients, 79 patients (22%) had an abnormal SPECT scan and 270 (74%) were classified as high risk. Both methods correctly identified patients with increased probability of MACE. However, clinical stratification performed better (sensitivity and negative predictive value 99% and 99% vs. 25% and 87%, respectively). High-risk patients with an abnormal SPECT scan had a modest increased risk of events (log-rank = 0.03; hazard ratio [HR] = 1.37; 95% confidence interval [95% CI], 1.02-1.82). Eighty-six patients underwent coronary angiography, and coronary artery disease (CAD) was found in 60%. High-risk patients with CAD had an increased incidence of events (log-rank = 0.008; HR=3.85; 95% CI, 1.46-13.22), but in those with an abnormal SPECT scan, the incidence of events was not influenced by CAD (log-rank = 0.23). Forty-six patients died. Clinical stratification, but not SPECT, correlated with the probability of death (log-rank = 0.02; HR=3.25; 95% CI, 1.31-10.82). Conclusion: SPECT should be restricted to high-risk patients. Moreover, in contrast to SPECT, the AST algorithm was also useful for predicting death by any cause in RTCs and for selecting patients for invasive coronary testing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vascular calcification is a strong prognostic marker of mortality in hemodialysis patients and has been associated with bone metabolism disorders in this population. In earlier stages of chronic kidney disease (CKD), vascular calcification also has been documented. This study evaluated the association between coronary artery calcification (CAC) and bone histomorphometric parameters in CKD predialysis patients assessed by multislice coronary tomography and by undecalcified bone biopsy. CAC was detected in 33 (66%) patients, and their median calcium score was 89.7 (0.4-2299.3 AU). The most frequent bone histologic alterations observed included low trabecular bone volume, increased eroded and osteoclast surfaces, and low bone-formation rate (BFR/BS). Multiple logistic regression analysis, adjusted for age, sex, and diabetes, showed that BFR/BS was independently associated with the presence of coronary calcification [p=.009; odd ratio (OR) = 0.15; 95% confidence interval (Cl) 0.036-0.619] This study showed a high prevalence of CAC in asymptomatic predialysis CKD patients. Also, there was an independent association of low bone formation and CAC in this population. In conclusion, our results provide evidence that low bone-formation rate constitutes another nontraditional risk factor for cardiovascular disease in CKD patients. 2010 American Society for Bone and Mineral Research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives This study was designed to evaluate whether the absence of coronary calcium could rule out >= 50% coronary stenosis or the need for revascularization. Background The latest American Heart Association guidelines suggest that a calcium score (CS) of zero might exclude the need for coronary angiography among symptomatic patients. Methods A substudy was made of the CORE64 (Coronary Evaluation Using Multi-Detector Spiral Computed Tomography Angiography Using 64 Detectors) multicenter trial comparing the diagnostic performance of 64-detector computed tomography to conventional angiography. Patients clinically referred for conventional angiography were asked to undergo a CS scan up to 30 days before. Results In all, 291 patients were included, of whom 214 (73%) were male, and the mean age was 59.3 +/- 10.0 years. A total of 14 (5%) patients had low, 218 (75%) had intermediate, and 59 (20%) had high pre-test probability of obstructive coronary artery disease. The overall prevalence of >= 50% stenosis was 56%. A total of 72 patients had CS = 0, among whom 14 (19%) had at least 1 >= 50% stenosis. The overall sensitivity for CS = 0 to predict the absence of >= 50% stenosis was 45%, specificity was 91%, negative predictive value was 68%, and positive predictive value was 81%. Additionally, revascularization was performed in 9 (12.5%) CS = 0 patients within 30 days of the CS. From a total of 383 vessels without any coronary calcification, 47 (12%) presented with >= 50% stenosis; and from a total of 64 totally occluded vessels, 13 (20%) had no calcium. Conclusions The absence of coronary calcification does not exclude obstructive stenosis or the need for revascularization among patients with high enough suspicion of coronary artery disease to be referred for coronary angiography, in contrast with the published recommendations. Total coronary occlusion frequently occurs in the absence of any detectable calcification. (Coronary Evaluation Using Multi-Detector Spiral Computed Tomography Angiography Using 64 Detectors [CORE-64]; NCT00738218) (J Am Coll Cardiol 2010;55:627-34) (C) 2010 by the American College of Cardiology Foundation