997 resultados para Tomografia computadorizada multislice
Resumo:
Introduction: This study aimed to describe the anatomy of mandibular premolars with type IX canal configuration by using micro–computed tomography. Methods: Mandibular premolars with radicular grooves (n = 105) were scanned, and 16 teeth with type IX configuration were selected. Number and location of canals, distances between anatomic landmarks, occurrence of apical delta, root canal fusion, and furcation canals, as well as 2-dimensional (area, perimeter, roundness, major and minor diameters) and 3-dimensional (volume, surface area, and structuremodel index) analysis were performed. Data were statistically compared by using analysis of variance and Kruskal-Wallis tests (a = 0.05). Results: Overall, specimens had 1 root with a main canal that divided into mesiobuccal, distobuccal, and lingual canals at the furcation level. Mean length of the teeth was 22.9 2.06 mm, and the configuration of the pulp chamber was mostly triangle-shaped. Mean distances from the furcation to the apex and cementoenamel junction were 9.14 2.07 and 5.59 2.19 mm, respectively. Apical delta, root canal fusion, and furcation canals were present in 4, 5, and 10 specimens, respectively. No statistical differences were found in the 2-dimensional and 3-dimensional analyses between root canals (P > .05). Conclusions: Type IX configuration of the root canal system was found in 16 of 105 mandibular premolars with radicular grooves. Most of the specimens had a triangle-shaped pulp chamber. Within this anatomic configuration, complexities of the root canal systems such as the presence of furcation canals, fusion of canals, oval-shaped canals in the apical third, small orifices at the pulp chamber level, and apical delta were also observed
Resumo:
Introduction: This study aimed to evaluate the close proximity established between the maxillary sinus floor and posterior teeth roots apices by using cone-beam computed tomographic scanning. Methods: The relationship of maxillary sinuses and posterior teeth roots, which were divided into 2 groups, was analyzed using i-CAT Vision software (Imaging Sciences, Hatfield, PA). Group 1 included all root apices found in close contact with the maxillary sinus floor without sinus floor elevation, whereas group 2 included all root apices that were protruded within the sinus producing an elevation of the bony cortical. Results: A total of 100 maxillary sinuses and 601 roots apices were evaluated. Group 1 presented 130 of 601 (21.6%) roots and group 2 presented 86 of 601 (14.3%) roots. Conclusions: The second molar mesiobuccal root apex is frequently found in close proximity with the sinus floor, and the relation between these anatomic structures should be considered in order to prevent an iatrogenic procedure and minimize the risks from an infectious disease within the sinus
Resumo:
A doença cardiovascular representa a principal causa de mortalidade no mundo. A capacidade de identificar, dentre os indivíduos assintomáticos, o subgrupo que apresenta maior risco de desenvolver eventos cardiovasculares no futuro representa uma etapa fundamental em qualquer estratégia voltada para a diminuição da taxas de eventos cardiovasculares. O primeiro passo na estratificação do risco cardiovascular é a utilização dos "escores de risco global", dentre os quais o mais frequentemente utilizado é o escore de Framingham. Entretanto, estudos prévios demonstraram que embora muito úteis, os escores clínicos, quando utilizados isoladamente, apresentam capacidade limitada de estratificação do risco cardiovascular em uma parcela significativa da população. É nesse contexto que o escore de cálcio (EC) coronariano e a angiotomografia das artérias coronárias podem desempenhar papel importante como ferramentas complementares na estratificação de risco dos pacientes assintomáticos. O EC coronariano proporciona importantes informações prognósticas que são incrementais aos escores clínicos baseados nos fatores de risco tradicionais e a outras modalidades diagnósticas, como a dosagem da proteína C reativa, por exemplo. Além disso, o EC também tem o potencial de alterar a conduta e auxiliar no manejo clínico dos pacientes. Já a angiotomografia coronariana proporciona avaliação detalhada da anatomia das artérias coronárias, permitindo visualizar não apenas o lúmen, mas também as paredes arteriais coronarianas. Comparada à coronariografia invasiva convencional, a angiotomografia apresenta excelente acurácia para identificar e, principalmente, excluir a presença de lesões obstrutivas significativas. Adicionalmente, demonstrou-se capaz de proporcionar informações prognósticas incrementais aos fatores de risco tradicionais e ao EC coronariano.
Resumo:
O termo gossipiboma é usado para descrever uma massa formada a partir de uma matriz de algodão cercada por uma reação inflamatória/granulomatosa. Sua incidência é estimada em 0,15% a 0,2%. O corpo estranho na cavidade abdominal pode servir de nicho para a proliferação de microrganismos e agir como foco primário para formação de abscessos e de peritonite. Vários estudos têm demonstrado a importância da correlação clínica com os diversos métodos de imagem (radiografia convencional, ultrassonografia, tomografia computadorizada e ressonância magnética) no diagnóstico dos gossipibomas. Este ensaio tem por objetivo demonstrar uma série de casos típicos de gossipibomas abdominais e ilustrar suas diversas formas de apresentação, com ênfase nos achados dos diferentes métodos de imagem, visando a familiarizar os radiologistas com esta enfermidade e seus principais diagnósticos diferenciais.
Resumo:
OBJETIVO: Descrever os principais achados de imagem em uma série de casos de tumores neuroendócrinos primários do pulmão (TNPs), destacando as alterações na tomografia computadorizada. MATERIAIS E MÉTODOS: Exames de 22 pacientes (12 homens, idade média de 60 anos) avaliados nos últimos cinco anos em nosso serviço, com confirmação histopatológica, foram retrospectivamente revistos por dois médicos radiologistas e os achados foram descritos em consenso, focando as alterações tomográficas. RESULTADOS: Descrevemos 5 carcinoides típicos, 3 carcinoides atípicos, 3 carcinomas neuroendócrinos de grandes células (CNGCs) e 11 cânceres pulmonares de pequenas células (CPPCs). Apenas um carcinoide típico apresentou aspecto característico de nódulo endobrônquico central com atelectasia pulmonar distal, enquanto os demais foram nódulos ou massas pulmonares. Os carcinoides atípicos eram massas pulmonares periféricas e heterogêneas. Um CNGC era massa periférica delimitada e homogênea, enquanto os demais eram mal delimitados e heterogêneos. Os 11 CPPCs eram massas centrais, infiltrativas e heterogêneas, com alterações pleuropulmonares secundárias. Calcificações estavam ausentes nos CNGCs e CPPCs. Metástases foram vistas inicialmente ou no seguimento de todos os CNGCs e CPPCs. CONCLUSÃO: Apesar de alguns aspectos semelhantes nos exames de imagem, os achados radiológicos, quando integrados às informações clínicas, podem constituir critérios importantes na diferenciação dos tipos histológicos de TNPs.
Resumo:
Tumores miofibroblásticos inflamatórios raramente acometem vias urinárias ou crianças, comumente mimetizando neoplasias malignas nos exames de imagem. Foram descritos apenas 35 casos desses tumores na bexiga de crianças, segundo a literatura recente. Os autores apresentam o caso de uma criança com um tumor miofibroblástico vesical que evoluiu favoravelmente após ressecção cirúrgica completa.
Resumo:
Relatamos o caso de uma mulher de 21 anos com história de seis meses de dispneia progressiva, tosse seca e perda de peso. A tomografia computadorizada de alta resolução revelou padrão de pavimentação em mosaico com áreas focais poupadas. A paciente foi submetida a biópsia pulmonar transbrônquica, que confirmou o diagnóstico de proteinose alveolar. Dois anos depois, sem tratamento, houve importante melhora das opacidades pulmonares.
Resumo:
OBJETIVO: Avaliar a PET/CT na abordagem de pacientes com câncer de cabeça e pescoço. MATERIAIS E MÉTODOS: Estudo retrospectivo de 63 prontuários e exames de PET/CT de pacientes com câncer de cabeça e pescoço. RESULTADOS: Foram encontradas alterações em 76% dos exames. Destes, 7 (11%) foram considerados falso-positivos, com SUV < 5,0. A PET/CT mostrou-se negativa em 15 situações (24%). Dos 14 casos nos quais se utilizou o exame para estadiamento, em 3 (22%) houve aumento no estadiamento. CONCLUSÃO: A PET/CT mostra-se como exame de potencial valor na rotina de avaliação de pacientes com câncer de cabeça e pescoço, entretanto, necessitamos de maior número de casos para definirmos protocolo de uso.
Resumo:
OBJETIVO: Estudo anatômico do áxis através de tomografia computadorizada (TC) em crianças de dois a dez anos de idade, mensurando a angulação das lâminas, espessura e comprimento de lâminas e pedículos e espessura da massa lateral. MÉTODOS: Estudou-se 64 TCs da coluna cervical de indivíduos com idades entre 24 e 120 meses, de ambos os sexos e sem deformidades cervicais. Correlacionaram-se as variáveis estudadas com os grupos etários e sexo dos pacientes. A análise estatística foi realizada por meio do teste t. RESULTADOS: Verificou-se que na faixa etária entre 24-48 meses, 5,5% das lâminas e 8,3% dos pedículos possuem espessura menores do que 3,5mm, espessura necessária para colocação de um parafuso. Entre 49-120 meses não há lâminas com espessuras menores do que 3,5mm e 1,2% dos pedículos possuem espessura menor do que 3,5mm. Em ambos os grupos etários não há comprimento de lâminas e pedículos menores do que 12 mm e massas laterais maiores do que 12 mm. CONCLUSÃO: A análise das dimensões obtidas no estudo permite, na maioria dos casos, a colocação de parafusos de 3,5mm nas lâminas e pedículos do áxis de crianças. Nível de Evidência II, Desenvolvimento de critérios diagnósticos em pacientes consecutivos.
Resumo:
OBJECTIVE: To evaluate tools for the fusion of images generated by tomography and structural and functional magnetic resonance imaging. METHODS: Magnetic resonance and functional magnetic resonance imaging were performed while a volunteer who had previously undergone cranial tomography performed motor and somatosensory tasks in a 3-Tesla scanner. Image data were analyzed with different programs, and the results were compared. RESULTS: We constructed a flow chart of computational processes that allowed measurement of the spatial congruence between the methods. There was no single computational tool that contained the entire set of functions necessary to achieve the goal. CONCLUSION: The fusion of the images from the three methods proved to be feasible with the use of four free-access software programs (OsiriX, Register, MRIcro and FSL). Our results may serve as a basis for building software that will be useful as a virtual tool prior to neurosurgery.
Resumo:
O tumor odontogênico cístico calcificante normalmente se manifesta como uma massa indolor, de crescimento lento, que acomete tanto a maxila como a mandíbula, tendo predileção pelo segmento anterior (área dos incisivos e caninos). Geralmente, ocorre em adultos jovens, na terceira a quarta década de vida, sem preferência por gênero. Imagens de tomografia computadorizada revelaram características importantes não detectadas na radiografia panorâmica, tais como fenestração, calcificação e estruturas dentiformes. A característica microscópica típica dessa lesão é a presença de células epiteliais aberrantes anucleadas, em quantidades variáveis, denominadas "células fantasmas". Também se pode encontrar dentina displásica e, ocasionalmente, os cistos estão associados a tecido dentário duro, semelhante ao odontoma. O tratamento do tumor odontogênico cístico calcificante incluiu simples enucleação e curetagem. O objetivo deste trabalho foi mostrar duas manifestações diferentes do tumor odontogênico cístico calcificante, em que a tomografia computadorizada, associada às características clínicas, foi ferramenta importante para o diagnóstico, o planejamento cirúrgico e o acompanhamento dos pacientes.
Resumo:
Background: Few data on the definition of simple robust parameters to predict image noise in cardiac computed tomography (CT) exist. Objectives: To evaluate the value of a simple measure of subcutaneous tissue as a predictor of image noise in cardiac CT. Methods: 86 patients underwent prospective ECG-gated coronary computed tomographic angiography (CTA) and coronary calcium scoring (CAC) with 120 kV and 150 mA. The image quality was objectively measured by the image noise in the aorta in the cardiac CTA, and low noise was defined as noise < 30HU. The chest anteroposterior diameter and lateral width, the image noise in the aorta and the skin-sternum (SS) thickness were measured as predictors of cardiac CTA noise. The association of the predictors and image noise was performed by using Pearson correlation. Results: The mean radiation dose was 3.5 ± 1.5 mSv. The mean image noise in CT was 36.3 ± 8.5 HU, and the mean image noise in non-contrast scan was 17.7 ± 4.4 HU. All predictors were independently associated with cardiac CTA noise. The best predictors were SS thickness, with a correlation of 0.70 (p < 0.001), and noise in the non-contrast images, with a correlation of 0.73 (p < 0.001). When evaluating the ability to predict low image noise, the areas under the ROC curve for the non-contrast noise and for the SS thickness were 0.837 and 0.864, respectively. Conclusion: Both SS thickness and CAC noise are simple accurate predictors of cardiac CTA image noise. Those parameters can be incorporated in standard CT protocols to adequately adjust radiation exposure.
Resumo:
O documento IAEA/TRS 457 [1] define qualidades de radiação para calibração de detectores utilizados em mediações na área de radiologia diagnóstica. O documento define qualidades específicas para feixes primários (RQR), transmitidos (RQA), bem como outros específicos para mamografia e tomografia computadorizada. Estas qualidades devem ser estabelecidas de acordo com a norma IEC 61267. O presente trabalho descreve a validação dos filtros de qualidade de radiação RQR, previamente estabelecidos, a determinação de filtros com qualidade de radiação RQA e a determinação das curvas de atenuação para ambos os casos.
Resumo:
In questo studio ci siamo proposti di investigare i sistemi di modulazione automatica della dose sui sistemi TC Multislice (Automatic Exposure Control – AEC) da tre diversi produttori, aventi differenti indicatori di qualità delle immagini. Il presente lavoro è stato svolto presso il Servizio di Fisica Sanitaria dell’Azienda Ospedaliera Universitaria - Policlinico Sant’Orsola-Malpighi di Bologna e consiste in un’analisi quantitativa della dose impiegata durante esami di Tomografia Computerizzata Multi-Slice (TCMS) e delle rispettive immagini radiologiche. Le immagini sono state acquisite con : GE LightSpeed VCT 64 e GE LightSpeed 16 (AEC AutomA 3D longitudinale e angolare), Siemens Sensation 16 (AEC CARE Dose 4D combinato), Philips Brilliance 16 e iCT 64 (separati in AEC ZDOM longitudinale e AEC DDOM angolare). Le acquisizioni TCMS sono state effettuate a differenti kV e mA di riferimento, al fine di investigarne gli effetti sulla modulazione, impiegando algoritmi di ricostruzione standard presenti su ogni macchina. Due fantocci antropomorfi simulanti la zona del torace e dell’addome sono stati utilizzati per simulare un paziente standard posizionato come in un esame clinico di routine ; a questo proposito, sono stati impiegati protocolli elicoidali standard con e senza modulazione. Sono inoltre stati testati differenti valori di indice di qualità delle immagini. Il profilo dei mA lungo la lunghezza è stato ottenuto utilizzando ImageJ, un programma open source comunemente utilizzato per l’elaborazione di immagini; i mAs sono stati normalizzati ad un fattore che tiene conto delle differenti geometrie e delle filtrazioni dei diversi scanner tomografici analizzati nell’esperienza. Il rumore è stato valutato tramite la scelta di determinate ROI (Region Of Interest) localizzate in aree il più possibili uniformi disponibili lungo i fantocci. Abbiamo registrato che una variazione del Noise Index o dei mAs di riferimento a seconda della tipologia di macchina analizzata risulta in uno shift dei profili di dose; lo stesso si è verificato quando sono stati cambiato kV o mA nella scout di acquisizione. Sistemi AEC longitudinali e combinati hanno mostrato profili di mAs normalizzati simili tra loro, con valori elevati evidenziati nella zona delle spalle e zona pelvi; sono state osservate differenze del 30-40% tra i differenti scanner tomografici. Solo in un caso di macchina analizzata si è verificato un comportamento opposto rispetto alle altre due tipologie di macchina in esame. A dispetto della differente natura dei sistemi AEC, i risultati ottenuti dai protocolli combinati e longitudinali sono simili tra loro. Il rumore presente nelle immagini è aumentato ad un livello accettabile e la sua uniformità lungo la direzione di scan è migliorata.
Resumo:
Ao criar a técnica para tratamento ortodôntico denominado Straight-Wire, Andrews introduziu o uso de bráquetes pré-programados, ou bráquetes construídos individualmente para cada dente, com o objetivo de melhor posicioná-los ao final do tratamento. Capelozza Filho sugeriu novas angulações e inclinações para dentes que necessitavam de ajuste ao final do tratamento, criando prescrições para os diferentes padrões faciais. O presente trabalho tem por objetivo avaliar as alterações nas inclinações dentárias causadas pelo tratamento ortodôntico nos dentes anteriores utilizando-se da prescrição Capelozza Classe II. Foram selecionados 17 indivíduos adultos de padrão facial II, portadores de má-oclusão Classe II; para tratamento ortodôntico compensatório, e em três tempos clínicos, relativos a três diferentes fios ortodônticos (.020 ; .019 x .025 , .021 x .025 ), foram realizados exames de tomografia computadorizada volumétrica, para mensuração e posterior avaliação das inclinações dentárias alcançadas em cada um dos tempos, pela ação de cada um dos fios, comparando-se estes valores aos da prescrição utilizada, bem como das diferenças ocorridas entre os tempos. Após a coleta de dados e aplicação dos testes estatísticos, concluiu-se que existe diferença estatística (p<0,05) na maioria dos valores da prescrição e os valores encontrados em cada um dos tempos avaliados; não foram encontradas diferenças estatisticamente significantes quando comparados os tempos estudados. Observou-se também uma tendência dos dentes a expressarem a prescrição apenas em T3.