929 resultados para System reliability index
Resumo:
veröffentlicht in: Schopenhauer, Arthur : Arthur Schopenhauers sämtliche Werke - München : Piper - Bd. 16 : Der Briefwechsel Arthur Schopenhauers ; 3, Nr.6, S 98-101;
Resumo:
veröffentlicht in: Schopenhauer, Arthur : Arthur Schopenhauers sämtliche Werke - München : Piper - Bd. 16 : Der Briefwechsel Arthur Schopenhauers ; S. 116-117
Resumo:
Jaques Gaffarel
Resumo:
Von R. v. Wettstein
Resumo:
Opera
Resumo:
von Herman Kahan
Resumo:
by Boaz Cohen
Resumo:
The usage of intensity modulated radiotherapy (IMRT) treatments necessitates a significant amount of patient-specific quality assurance (QA). This research has investigated the precision and accuracy of Kodak EDR2 film measurements for IMRT verifications, the use of comparisons between 2D dose calculations and measurements to improve treatment plan beam models, and the dosimetric impact of delivery errors. New measurement techniques and software were developed and used clinically at M. D. Anderson Cancer Center. The software implemented two new dose comparison parameters, the 2D normalized agreement test (NAT) and the scalar NAT index. A single-film calibration technique using multileaf collimator (MLC) delivery was developed. EDR2 film's optical density response was found to be sensitive to several factors: radiation time, length of time between exposure and processing, and phantom material. Precision of EDR2 film measurements was found to be better than 1%. For IMRT verification, EDR2 film measurements agreed with ion chamber results to 2%/2mm accuracy for single-beam fluence map verifications and to 5%/2mm for transverse plane measurements of complete plan dose distributions. The same system was used to quantitatively optimize the radiation field offset and MLC transmission beam modeling parameters for Varian MLCs. While scalar dose comparison metrics can work well for optimization purposes, the influence of external parameters on the dose discrepancies must be minimized. The ability of 2D verifications to detect delivery errors was tested with simulated data. The dosimetric characteristics of delivery errors were compared to patient-specific clinical IMRT verifications. For the clinical verifications, the NAT index and percent of pixels failing the gamma index were exponentially distributed and dependent upon the measurement phantom but not the treatment site. Delivery errors affecting all beams in the treatment plan were flagged by the NAT index, although delivery errors impacting only one beam could not be differentiated from routine clinical verification discrepancies. Clinical use of this system will flag outliers, allow physicists to examine their causes, and perhaps improve the level of agreement between radiation dose distribution measurements and calculations. The principles used to design and evaluate this system are extensible to future multidimensional dose measurements and comparisons. ^
Resumo:
Objective. Long Term Acute Care Hospitals (LTACs) are subject to Medicare rules because they accept Medicare and Medicaid patients. In October 2002, Medicare changed the LTAC reimbursement formulas, from a cost basis system to a Prospective Payment System (PPS). This study examines whether the PPS has negatively affected the financial performance of the LTAC hospitals in the period following the reimbursement change (2003-2006), as compared to the period prior to the change (1999-2003), and if so, to what extent. This study will also examine whether the PPS has resulted in a decreased average patient length of stay (LOS) in the LTAC hospitals for the period of 2003-2006 as compared to the prior period of 1999-2003, and if so, to what extent. ^ Methods. The study group consists of two large LTAC hospital systems, Kindred Healthcare Inc. and Select Specialty Hospitals of Select Medical Corporation. Financial data and operational indicators were reviewed, tabulated and dichotomized into two groups, covering the two periods: 1999-2002 and 2003-2006. The financial data included net annual revenues, net income, revenue per patient per day and profit margins. It was hypothesized that the profit margins for the LTAC hospitals were reduced because of the new PPS. Operational indicators, such as annual admissions, annual patient days, and average LOS were analyzed. It was hypothesized that LOS for the LTAC hospitals would have decreased. Case mix index, defined as the weighted average of patients’ DRGs for each hospital system, was not available to cast more light on the direction of LOS. ^ Results. This assessment found that the negative financial impacts did not materialize; instead, financial performance improved during the PPS period (2003-2006). The income margin percentage under the PPS increased for Kindred by 24%, and for Select by 77%. Thus, the study’s working hypothesis of reduced income margins for the LTACs under the PPS was contradicted. As to the average patient length of stay, LOS decreased from 34.7 days to 29.4 days for Kindred, and from 30.5 days to 25.3 days for Select. Thus, on the issue of LTAC shorter length of stay, the study’s working hypothesis was confirmed. ^ Conclusion. Overall, there was no negative financial effect on the LTAC hospitals during the period of 2003-2006 following Medicare implementation of the PPS in October 2002. On the contrary, the income margins improved significantly. ^ During the same period, LOS decreased following the implementation of the PPS. This was consistent with the LTAC hospitals’ pursuit of financial incentives.^
Resumo:
Objective. Long Term Acute Care Hospitals (LTACs) are subject to Medicare rules because they accept Medicare and Medicaid patients. In October 2002, Medicare changed the LTAC reimbursement formulas, from a cost basis system to a Prospective Payment System (PPS). This study examines whether the PPS has negatively affected the financial performance of the LTAC hospitals in the period following the reimbursement change (2003–2006), as compared to the period prior to the change (1999–2003), and if so, to what extent. This study will also examine whether the PPS has resulted in a decreased average patient length of stay (LOS) in the LTAC hospitals for the period of 2003–2006 as compared to the prior period of 1999-2003, and if so, to what extent. ^ Methods. The study group consists of two large LTAC hospital systems, Kindred Healthcare Inc. and Select Specialty Hospitals of Select Medical Corporation. Financial data and operational indicators were reviewed, tabulated and dichotomized into two groups, covering the two periods: 1999–2002 and 2003–2006. The financial data included net annual revenues, net income, revenue per patient per day and profit margins. It was hypothesized that the profit margins for the LTAC hospitals were reduced because of the new PPS. Operational indicators, such as annual admissions, annual patient days, and average LOS were analyzed. It was hypothesized that LOS for the LTAC hospitals would have decreased. Case mix index, defined as the weighted average of patients’ DRGs for each hospital system, was not available to cast more light on the direction of LOS. ^ Results. This assessment found that the negative financial impacts did not materialize; instead, financial performance improved during the PPS period (2003–2006). The income margin percentage under the PPS increased for Kindred by 24%, and for Select by 77%. Thus, the study’s working hypothesis of reduced income margins for the LTACs under the PPS was contradicted. As to the average patient length of stay, LOS decreased from 34.7 days to 29.4 days for Kindred, and from 30.5 days to 25.3 days for Select. Thus, on the issue of LTAC shorter length of stay, the study’s working hypothesis was confirmed. ^ Conclusion. Overall, there was no negative financial effect on the LTAC hospitals during the period of 2003–2006 following Medicare implementation of the PPS in October 2002. On the contrary, the income margins improved significantly. ^ During the same period, LOS decreased following the implementation of the PPS. This was consistent with the LTAC hospitals’ pursuit of financial incentives. ^
Resumo:
Critically ill and injured patients require pain relief and sedation to reduce the body's stress response and to facilitate painful diagnostic and therapeutic procedures. Presently, the level of sedation and analgesia is guided by the use of clinical scores which can be unreliable. There is therefore, a need for an objective measure of sedation and analgesia. The Bispectral Index (BIS) and Patient State Index (PSI) were recently introduced into clinical practice as objective measures of the depth of analgesia and sedation. ^ Aim. To compare the different measures of sedation and analgesia (BIS and PSI) to the standard and commonly used modified Ramsay Score (MRS) and determine if the monitors can be used interchangeably. ^ Methods. MRS, BIS and PSI values were obtained in 50 postoperative cardiac surgery patients requiring analgesia and sedation from June to December 2004. The MRS, BIS and PSI values were assessed hourly for up to 6-h by a single observer. ^ The relationship between BIS and PSI values were explored using scatter plots and correlation between MRS, BIS and PSI was determined using Spearman's correlation coefficient. Intra-class correlation (ICC) was used to determine the inter-rater reliability of MRS, BIS and PSI. Kappa statistics was used to further evaluate the agreement between BIS and PSI at light, moderate and deep levels of sedation. ^ Results. There was a positive correlation between BIS and PSI values (Rho = 0.731, p<0.001). Intra-class correlation between BIS and PSI was 0.58, MRS and BIS 0.43 and MRS and PSI 0.27. Using Kappa statistics, agreement between MRS and BIS was 0.35 (95% CI: 0.27–0.43) and for MRS and PSI was 0.21 (95% CI: 0.15–0.28). The kappa statistic for BIS and PSI was 0.45 (95% CI: 0.37–0.52). Receiver operating characteristics (ROC) curves constructed to detect undersedation indicated an area under the curve (AUC) of 0.91 (95% CI = 0.87 to 0.94) for the BIS and 0.84 (95% CI = 0.79 to 0.88) for the PSI. For detection of oversedation, AUC for the BIS was 0.89 (95% CI = 0.84 to 0.92) and 0.80 (95% CI = 0.75 to 0.85) for the PSI. ^ Conclusions. There is a statistically significant positive correlation between the BIS and PSI but poor correlation and poor test agreement between the MRS and BIS as well as MRS and PSI. Both the BIS and PSI demonstrated a high level of prediction for undersedation and oversedation; however, the BIS and PSI can not be considered interchangeable monitors of sedation. ^
Resumo:
The prevalence of obesity has increased sharply in the United States since the mid 1970's. Obese women who become pregnant are at increased risk of pregnancy complications for both mother and fetus. This study assessed whether women in higher body mass index (BMI) categories engage in the preventive behaviors of contraception more frequently than normal weight women. It also evaluated the type of contraception used by both obese and normal weight women. The study used cross-sectional data from 7 states participating in the Family Planning Module of the 2006 Behavioral Risk Factor Surveillance System (BRFSS). The Behavioral Risk Factor Surveillance System survey is an annual random digit dialed telephone survey of the non-institutionalized civilian population aged 18 years and older. The Family Planning Module was administered by Arizona, Kentucky, Minnesota, Missouri, Montana, Oregon, and Wisconsin. Of the 4,757 women who participated in the Family Planning Module, 2,244 (53.2%) were normal weight, 1,202 (25.6%) were overweight, and 1,072 (21.2%) were obese. The majority of these women 4,115 (86.2%) reported using some type of contraception to prevent pregnancy. Six hundred forty two women (13.8%) stated they did not use any type of contraception to prevent pregnancy. Within body mass index categories, 14% of normal weight women, 13% of overweight women, and 13.4% of obese women did not use any type of contraception. Neither the bivariate analysis nor the logistic regressions found body mass index categories to be statistically associated with contraceptive use. The relationship between body mass index categories and contraceptive method was found to be statistically significant. The predictive probability graph found that women at all levels of BMI have a lower probability of using barrier contraception methods as compared to procedural and hormonal methods. Hormonal contraception methods have the highest probability of use for women with a BMI of 15 to 25. In contrast, the probability of using procedural contraception methods is relatively flat and less than hormonal methods for BMI between 15 and 25. However, the probability of using procedural contraception increases dramatically with a BMI greater than 25. At a BMI greater than 42, women have a greater than 50% probability of using procedural contraception. Although a relationship between body mass index and contraception use was not found, contraception method was found to be associated with body mass index. The reasons why normal weight women prefer hormonal contraception while overweight/obese women are more likely to use procedural methods needs to be explored. By understanding the relationship between obesity and contraception, we can hopefully decrease unintended pregnancies and overall improve pregnancy related health outcomes. To determine if relationships between contraception use/type and body mass index exist, further research needs to be conducted on a national level. ^