962 resultados para Slope efficiencies
Resumo:
JORNADAS DE ELECTROQUÍMICA E INOVAÇÃO 2013
Resumo:
III Jornadas de Electroquímica e Inovação (Electroquímica e Nanomateriais), na Universidade de Trás-os-Montes e Alto Douro, Vila Real, 16 a 17 de Setembro de 2013
Resumo:
Graduate Student Symposium on Molecular Imprinting 2013, na Queen’s University, Belfast, United Kingdom, 15 a 17 de Agosto de 2013
Resumo:
Cardiopulmonary exercise testing (CPET) is an objective method for assessment of functional capacity and for prognostic stratification of patients with chronic heart failure (CHF). In this study, we analyzed the prognostic value of a recently described CPET-derived parameter, the minute ventilation to carbon dioxide production slope normalized for peak oxygen consumption (VE/VCO2 slope/pVO2). METHODS: We prospectively studied 157 patients with stable CHF and dilated cardiomyopathy who performed maximal CPET using the modified Bruce protocol. The prognostic value of VE/VCO2 slope/pVO2 was determined and compared with traditional CPET parameters. RESULTS: During follow-up 37 patients died and 12 were transplanted. Mean follow-up in surviving patients was 29.7 months (12-36). Cox multivariate analysis revealed that VE/VCO2 slope/pVO2 had the greatest prognostic power of all the parameters studied. A VE/VCO2 slope/pVO2 of > or = 2.2 signaled cases at higher risk. CONCLUSION: Normalization of the ventilatory response to exercise for peak oxygen consumption appears to increase the prognostic value of CPET in patients with CHF.
Resumo:
Signal Processing: Algorithms, Architectures, Arrangements, and Applications (SPA), 2013
Resumo:
A água é um recurso natural único, escasso e essencial a todos os seres vivos, o que a torna um bem de extrema importância. Nos dias de hoje, o desperdício deste bem, aliado ao aumento da sua procura, tornou-se um problema devido à decrescente disponibilidade de água doce no nosso planeta. Todas as águas que rejeitamos depois da sua utilização para diversos fins, designadas de águas residuais, necessitam de tratamento antes de serem devolvidas ao meio ambiente. O seu tratamento é realizado numa Estação de Tratamento de Águas Residuais (ETAR) e o processo de tratamento depende das suas características. A ETAR das Termas de S. Vicente, em Penafiel, trabalha no seu limite de capacidade, apresenta uma sobrecarga hidráulica gerada por uma afluência de águas pluviais e o processamento das lamas geradas não permite uma secagem tão completa como seria desejável. Assim, este trabalho teve como objetivo o estudo do funcionamento desta ETAR com a finalidade de propor soluções que o possam otimizar. As soluções propostas para otimizar o funcionamento da ETAR em estudo são: i) a substituição de grades de limpeza manual por grades de limpeza automática de forma a reduzir a necessidade da intervenção do operador ao nível da remoção e condicionamento dos gradados; ii) a construção de um desarenador arejado que além de remover areias de diâmetro superior a 0,2 mm promove também a remoção de gorduras, protegendo desta forma os equipamentos a jusante da abrasão/desgaste prematuros e reduzindo a formação de depósitos nas tubagens; iii) a construção de um tanque de equalização de forma a garantir uma distribuição mais uniforme dos caudais e da carga poluente; iv) a substituição do enchimento do leito percolador por um meio de suporte plástico que permite atingir melhores eficiências de remoção neste tratamento biológico; v) a alteração do agente de desinfeção para radiação ultravioleta, evitando a adição de produtos químicos na água residual e possível formação de subprodutos prejudiciais ao ambiente, como ocorreria no caso da cloragem; e vi) a substituição da desidratação de lamas em leitos de secagem por filtros de banda, que é um processo mais rápido, que ocupa menos espaço e permite atingir elevadas eficiências de remoção de humidade. Para cada uma das sugestões são apresentadas as correspondentes especificações técnicas e dimensionamento. As sugestões de melhoria apresentadas neste trabalho constituem uma alternativa mais económica do que a ampliação da ETAR, que genericamente corresponde à duplicação da linha de tratamento atual. Devido à menor complexidade em termos de construção, estas sugestões podem vir a ser implementadas num futuro próximo, prolongando assim um pouco mais a vida útil da ETAR atual.
Resumo:
O elevado consumo de água associado à escassez deste recurso contribuiu para que alternativas de reutilização/reciclagem de água fossem estudadas que permitam diminuir o seu consumo e minimizar a dependência das indústrias. Monitorizar e avaliar os consumos de água, a nível industrial, é imprescindível para assegurar uma gestão sustentável dos recursos hídricos, sendo este o objetivo da presente dissertação. As alternativas encontradas na unidade industrial em estudo foram a substituição do equipamento sanitário e o aproveitamento do efluente tratado para operações de lavagem e/ou arrefecimento por contacto direto. A maioria do equipamento sanitário não é eficiente, tendo-se proposto a substituição desse sistema por um de menor consumo que permitirá uma poupança de 30 % no consumo de água, que corresponderá a 12 149,37 €/ano, sendo o retorno do investimento estimado em 3 meses. O efluente industrial na entrada da ETAR e nas diferentes etapas - tratamento primário de coagulação/floculação; tratamento secundário ou biológico em SBR; tratamento terciário de coagulação/floculação - foi caracterizado através da medição da temperatura, pH, oxigénio dissolvido e pela determinação da cor, turvação, sólidos suspensos totais (SST), azoto total, carência química de oxigénio (CQO), Carência Bioquímica de Oxigénio ao fim de 5 dias (CBO5) e razão CBO5/CQO. Esta caracterização permitiu avaliar o efluente industrial bruto que se caracteriza por um pH alcalino (8,3 ± 1,7); condutividade baixa (451 ± 200,2 μS/cm); elevada turvação (11 255 ± 8812,8 FTU); cor aparente (63 670 ± 42293,4 PtCo) e cor verdadeira (33 621 ± 19547,9 PtCo) elevadas; teores elevados de CQO (24 753 ± 11806,7 mg/L O2) SST (5 164 ± 3845,5 mg/L) e azoto total (718 mg/L) e um índice de biodegradabilidade baixo (razão CBO5/CQO de 1,4). Este estudo permitiu verificar que a eficiência global do tratamento do efluente foi 82 % na remoção da turvação, 83 % na remoção da cor aparente, 96 % na remoção da cor verdadeira, 85 % na remoção da CQO e 30 % na remoção dos SST. Quanto às eficiências de remoção associadas ao tratamento primário no que diz respeito à turvação, cor aparente, CQO e SST, apresentam valores inferiores aos referidos na literatura para o mesmo tipo de tratamento em efluentes similares. As eficiências de remoção obtidas no tratamento secundário são inferiores às do tratamento primário: turvação, cor aparente, CQO e SST, pelo que procurou-se otimizar a primeira etapa do processo de tratamento Neste estudo de otimização estudou-se a influência de cinco coagulantes – Sulfato de Alumínio, PAX XL – 10, PAX 18, cloreto de ferro e a conjugação de PAX 18 com sulfato de ferro - e seis floculantes – Superfloc A 150, Superfloc A 130, PA 1020, Ambifloc 560, Ambifloc C58 e Rifloc 54 - no tratamento físico-químico do efluente. O PAX 18 e o Ambifloc 560 UUJ foram os que apresentaram as mais elevadas eficiências de remoção (99,85 % na cor, 99,87 % na turvação, 90,12 % na CQO e 99,87 % nos SST). O custo associado a este tratamento é de 1,03 €/m3. Pela comparação com os critérios de qualidade no guia técnico ERSAR, apenas o parâmetro da CQO excede o valor, contudo o valor obtido permite diminuir os custos associados a um tratamento posterior para remoção da CQO remanescente no efluente residual tratado.
Resumo:
Desde sempre o Homem procurou automatizar tarefas repetitivas. Tanto na indústria como no sector doméstico ou de comércio estão constantemente a surgir novos equipamentos procurando aumentar o nível de automação de diversas tarefas. A necessidade de empresas criadoras de produtos inovadores se manterem concorrenciais obrigou à adopção de métodos de projecto e planeamento mais estruturados e eficientes que eliminem os desperdícios tanto de material como de tempo. Diversas construções em termos orçamentais e o aumento da procura de produtos de alta qualidade a baixo custo deu origem a um novo tipo de programas, os programas de simulação virtual. Tal como na indústria, também na investigação nas Instituições de Ensino Superior se procuram adoptar os métodos de trabalho mais eficientes possíveis. Uma parte dos programas de simulação robótica utilizados hoje em dia na investigação no Instituto Superior de Engenharia do Porto estão concebidos em linguagem C. Embora esta linguagem seja extremamente capaz, existem métodos mais adequados de simulação que aceleram o processo de modelação permitindo a visualização do movimento e simulação de diversas situações potencialmente criticas sem existir a necessidade de construção de um protótipo funcional do robô. Durante o último ano, este projecto permitiu construir um modelo de um robô quadrúpede num programa de simulação virtual chamado Simmechanics™. Embora haja já algum trabalho desenvolvido nesta área, constatou-se que a informação existente possuía algumas lacunas. Com o trabalho desenvolvido preparou-se esta dissertação que pretende clarificar algumas questões que surgem na modelação de um robô. Neste documento explica-se como modelar um robô de corpo flexível, modelar as pernas e as respectivas juntas da anca e do joelho assim como também se apresenta a modelação de um contacto com o solo recorrendo a um modelo descrito na literatura. Este documento foi escrito a pensar no leitor, procurando-se explicar de forma simples mas concisa os diversos passos necessários para construir um modelo virtual de um robô. O autor espera, desta forma, ajudar futuros colegas que pretendam trabalhar com o Simmechanics™ a mais facilmente se integrarem com o programa aumentando desta forma o declive da curva de aprendizagem e permitindo um maior aproveitamento desta ferramenta.
Resumo:
Smart Cities are designed to be living systems and turn urban dwellers life more comfortable and interactive by keeping them aware of what surrounds them, while leaving a greener footprint. The Future Cities Project [1] aims to create infrastructures for research in smart cities including a vehicular network, the BusNet, and an environmental sensor platform, the Urban Sense. Vehicles within the BusNet are equipped with On Board Units (OBUs) that offer free Wi-Fi to passengers and devices near the street. The Urban Sense platform is composed by a set of Data Collection Units (DCUs) that include a set of sensors measuring environmental parameters such as air pollution, meteorology and noise. The Urban Sense platform is expanding and receptive to add new sensors to the platform. The parnership with companies like TNL were made and the need to monitor garbage street containers emerged as air pollution prevention. If refuse collection companies know prior to the refuse collection which route is the best to collect the maximum amount of garbage with the shortest path, they can reduce costs and pollution levels are lower, leaving behind a greener footprint. This dissertation work arises in the need to monitor the garbage street containers and integrate these sensors into an Urban Sense DCU. Due to the remote locations of the garbage street containers, a network extension to the vehicular network had to be created. This dissertation work also focus on the Multi-hop network designed to extend the vehicular network coverage area to the remote garbage street containers. In locations where garbage street containers have access to the vehicular network, Roadside Units (RSUs) or Access Points (APs), the Multi-hop network serves has a redundant path to send the data collected from DCUs to the Urban Sense cloud database. To plan this highly dynamic network, the Wi-Fi Planner Tool was developed. This tool allowed taking measurements on the field that led to an optimized location of the Multi-hop network nodes with the use of radio propagation models. This tool also allowed rendering a temperature-map style overlay for Google Earth [2] application. For the DCU for garbage street containers the parner company provided the access to a HUB (device that communicates with the sensor inside the garbage containers). The Future Cities use the Raspberry pi as a platform for the DCUs. To collect the data from the HUB a RS485 to RS232 converter was used at the physical level and the Modbus protocol at the application level. To determine the location and status of the vehicles whinin the vehicular network a TCP Server was developed. This application was developed for the OBUs providing the vehicle Global Positioning System (GPS) location as well as information of when the vehicle is stopped, moving, on idle or even its slope. To implement the Multi-hop network on the field some scripts were developed such as pingLED and “shark”. These scripts helped upon node deployment on the field as well as to perform all the tests on the network. Two setups were implemented on the field, an urban setup was implemented for a Multi-hop network coverage survey and a sub-urban setup was implemented to test the Multi-hop network routing protocols, Optimized Link State Routing Protocol (OLSR) and Babel.
Resumo:
The opto-electronic properties of copper zinc tin sulfide can be tuned to achieve better cell efficiencies by controlled incorporation of selenium. In this paper we report the growth of Cu2ZnSn(S,Se)4 (CZTSSe) using a hybrid process involving the sequential evaporation of Zn and sputtering of the sulfide precursors of Cu and Sn, followed by a selenization step. Two approaches for selenization were followed, one using a tubular furnace and the other using a rapid thermal processor. The effects of annealing conditions on the morphological and structural properties of the films were investigated. Scanning electron microscopy and energy dispersive spectroscopy were employed to investigate the morphology and composition of the films. Structural analyses were done using X-ray diffraction (XRD) and Raman spectroscopy. Structural analyses revealed the formation of CZTSSe. This study shows that regardless of the selenization method a temperature above 450 °C is required for conversion of precursors to a compact CZTSSe layer. XRD and Raman analysis suggests that the films selenized in the tubular furnace are selenium rich whereas the samples selenized in the rapid thermal processor have higher sulfur content.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Civil – Ramo de Estruturas e Geotecnia
Resumo:
The present work aims to achieve and further develop a hydrogeomechanical approach in Caldas da Cavaca hydromineral system rock mass (Aguiar da Beira, NW Portugal), and contribute to a better understanding of the hydrogeological conceptual site model. A collection of several data, namely geology, hydrogeology, rock and soil geotechnics, borehole hydraulics and hydrogeomechanics, was retrieved from three rock slopes (Lagoa, Amores and Cancela). To accomplish a comprehensive analysis and rock engineering conceptualisation of the site, a multi‐technical approach were used, such as, field and laboratory techniques, hydrogeotechnical mapping, hydrogeomechanical zoning and hydrogeomechanical scheme classifications and indexes. In addition, a hydrogeomechanical data analysis and assessment, such as Hydro‐Potential (HP)‐Value technique, JW Joint Water Reduction index, Hydraulic Classification (HC) System were applied on rock slopes. The hydrogeomechanical zone HGMZ 1 of Lagoa slope achieved higher hydraulic conductivities with poorer rock mass quality results, followed by the hydrogeomechanical zone HGMZ 2 of Lagoa slope, with poor to fair rock mass quality and lower hydraulic parameters. In addition, Amores slope had a fair to good rock mass quality and the lowest hydraulic conductivity. The hydrogeomechanical zone HGMZ 3 of Lagoa slope, and the hydrogeomechanical zones HGMZ 1 and HGMZ 2 of Cancela slope had a fair to poor rock mass quality but were completely dry. Geographical Information Systems (GIS) mapping technologies was used in overall hydrogeological and hydrogeomechanical data integration in order to improve the hydrogeological conceptual site model.
Resumo:
O presente trabalho tem como objetivo a otimização da etapa de fermentação dos açúcares obtidos a partir da drêche cervejeira para produção do bioetanol através da utilização das leveduras Pichia stipitis NCYC 1541 e Kluyveromyces marxianus NCYC 2791 como agentes fermentativos. O meio de cultura usado para manter as culturas destas leveduras foi Yeast Extract Peptone Dextrose (YEPD). O principal propósito deste trabalho foi o de encontrar alternativas aos combustíveis fósseis, pautando-se por soluções inofensivas para o meio ambiente e sustentáveis. Assim, o trabalho está dividido em quatro etapas: 1) caraterização química e biológica da drêche; 2) pré-tratamento ácido e hidrólise enzimática para primeiramente quebrar as moléculas de lenhina que envolvem os polímeros de celulose e hemicelulose e em seguida romper as ligações poliméricas destas macromoléculas por ação enzimática e transforma-las em açúcares simples, respetivamente, obtendo-se então a glucose, a maltose, a xilose e a arabinose; e, por último, 3) otimização da etapa de fermentação da glucose, maltose e das pentoses que constitui a condição essencial para se chegar à síntese do bioetanol de um modo eficiente e sustentável e 4) a recuperação do bioetanol produzido por destilação fracionada. A quantificação dos açúcares libertados no processo foi feita recorrendo a análises por cromatografia líquida de alta eficiência (HPLC). Neste estudo foram identificados e quantificados cinco açúcares: Arabinose, Glucose, Maltose, Ribose e Xilose. Na etapa de pré-tratamento e hidrólise enzimática foram usados os ácidos clorídrico (HCl) e nítrico (HNO3) com a concentração de 1% (m/m), e as enzimas Glucanex 100g e Ultraflo L. Foram testadas seis condições de pré-tratamento e hidrólise enzimática, alterando os parâmetros tempo de contacto e razão enzimas/massa de drêche, respetivamente, e mantendo a temperatura (50 ºC), velocidade de agitação (75 rpm) e concentração dos ácidos (1% (m/m)). No processamento de 25 g de drêche seca com 0,5 g de Glucanex, 0,5 mL de Ultraflo e um tempo de reação de 60 minutos para as enzimas foi obtida uma eficiência de 15%, em hidrolisado com 6% da celulose. Realizou-se a fermentação do hidrolisado resultante do pré-tratamento ácido e hidrólise enzimática de drêche cervejeira e de meios sintéticos preparados com os açúcares puros, usando as duas estirpes selecionadas para este estudo: Pichia stipitis NCYC 1541 e Kluyveromyces marxianus NYCY 2791. As eficiências de fermentação dos açúcares nos meios sintéticos foram superiores a 80% para ambas as leveduras. No entanto, as eficiências de fermentação do hidrolisado da drêche foram de 45,10% pela Pichia stipitis e de 36,58 para Kluyveromyces marxianus, para um tempo de fermentação de 72 horas e à temperatura de 30 °C. O rendimento teórico em álcool no hidrolisado da drêche é de 0,27 g/g, três vezes maior do que o real (0,0856 g/g), para Pichia stipitis e de 0,19 g/g seis vezes maior do que o real (0,0308 g/g), para a Kluyveromyces marxianus.
Resumo:
A instabilização de taludes rochosos, com consequências mais ou menos gravosas, repete-se com frequência no território nacional. Os enquadramentos destes incidentes são diversos, sendo mais comum e mais visível a sua ocorrência em taludes adjacentes a vias de comunicação. No entanto, o fenómeno repete-se também em vertentes naturais, geralmente em alturas de pluviosidade mais prolongada e intensa. No presente trabalho reveem-se conceitos associados a maciços rochosos, nomeadamente as principais classificações geotécnicas e as diferentes tipologias de instabilidade em taludes rochosos. Desenvolve-se um caso de estudo de uma vertente localizada em S. Simão, concelho de Amarante. Percorrem-se as sucessivas fases de estudo, incluindo a realização da fotografia aérea com recurso a um veículo não tripulado, a geração de um modelo 3D de elevada precisão da vertente e a caracterização e a classificação dos diferentes afloramentos rochosos. Desenvolve-se uma metodologia de inspeção com a criação de dois conjuntos de fichas e propõe-se o agravamento da classificação das anomalias perante a simultaneidade de ocorrência de anomalias de idêntica gravidade e a hierarquização dos blocos potencialmente instáveis, de acordo com os respetivos níveis de gravidade (NGB). Recorre-se ao programa de modelação da queda de blocos, “Rocfall (4.0”, da “Rocscience”, a partir de trajetórias definidas no modelo 3D gerado e propõem-se soluções de reforço e de proteção da vertente.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia do Ambiente – Perfil de Engenharia Sanitária