944 resultados para Sessile drop
Resumo:
This PhD study aims to exploit the rich archive provided by the Miocene mollusc fauna of the Pebas Formation and other inland Miocene Amazonian formations to reconstruct landscape evolution and biotic development in lowland Amazonia during the Neogene. Over 160 samples from more than 70 Pebas Formation outcrops mostly collected by the author were processed for this study. Additional samples were collected in Andean areas of Colombia and Venezuela and further material from other northwestern South American basins was studied in museums. Pebas Formation samples and well log data made available by Occidental Peru from three wells in the Marañon Basin in Peru were also investigated. During this study four genera and 74 species from the Pebas Formation have been described and a further 13 species have been introduced in open nomenclature, and several species were reported for the first time. The number of mollusc species attributed to the Pebas fauna has increased from around 50 to 156. The Pebas fauna is characterised as aquatic, endemic and extinct, and is a typical representative of a long-lived lake fauna. Fluvial taxa are not common, (marginal) marine taxa are rare. An additional molluscan fauna from the Miocene Solimões Formation of Brazil, containing 13 fresh water species was also described. The newly documented fauna was used to improve biostratigraphic framework of Miocene Amazonian deposits. Twelve mollusc zones were introduced, the upper eleven of which cover a time interval of approximately seven million years covered previously by only three pollen zones. An age model calculated for the borehole data indicates that the Pebas Formation was deposited between c. 24 and 11 Ma. The areal distribution of the outcropping mollusc zones uncovered a broad dome structure, termed here the Iquitos-Araracuara anteclise in the study area. The structure appears to have influenced river courses and also contributed to edaphic heterogeneity that may have been in part responsible for the current high biodiversity in the study area. The Pebas system was a huge system (> one million km2) dominated by relatively shallow lakes, but also containing swamps and rivers. The system was fed by rivers draining the emergent Andes in the west and lowlands and cratons to the east. The Pebas system was located at sea level and was open to marine settings through a northern portal running through the Llanos Basin and East Venezuela Basin towards the Caribbean. Cyclical baselevel changes possibly related to Mylankhovitch cycles, have been documented in depositional sequences of the Pebas Formation. The composition of the Pebasian mollusc fauna implies that the system was mostly a fresh water system. Such an interpretation is matched by strontium isotope ratios as well as very negative δ18O ratios found in the shells, but is at odds with oligohaline and mesohaline ichnofacies found in the same strata. The mollusc fauna of the Pebas Formation diversified through most of the existence of the lake system. The diversification was mostly the result of in-situ cladogenesis. The success of some of the Pebasian endemic clades is explained by adaptation to fresh water, low oxygen, common unconsolidated lake bottoms (soup grounds) as well as high predation intensity. Maximum diversity was reached at the base of the late Middle to early Late Miocene Grimsdalea pollen zone, some 13 Ma. At the time some 85 species co-occurred, 67 of which are considered as Pebasian endemics. A subsequent drop in species richness coincides with indications of elevated salinities, although a causal relation still needs to be established. Apparently the Pebas fauna went (almost) entirely extinct with the replacement of the lake system into a fluvio-tidal system during the Early Late Miocene, some 11 Ma.
Resumo:
Tässä työssä tutkitaan muuttuvanopeuksisen tuulivoimakäytön verkkoliityntöjä, verkkomääräyksiä ja mittausmenetelmiä Euroopassa. Yleiset tuulivoimalaitoksen verkkomääräyksiin liittyvät asiat on selitetty standardisarjassa IEC 61000 ja mittauksiin liittyvät säännökset standardissa IEC 61400-21. Työssä selvitetään Euroopan yleiset verkkomääräykset ja vertaillaan niitä keskenään, sekä määritetään tärkeimmät mittaukset. Lisäksi esitellään eräs standardimittauksiin soveltuva mittalaite ja analysoidaan täystehomuokkaimen suorituskykyä tuulivoimapuistossa. Työssä havaittiin, että standardin mukaisten mittausten toteuttaminen ja analysointi on hyvin haastava prosessi. Verkkomääräysten eroavaisuudet aiheuttavat hankaluuksia tuulivoimalan valmistajan ja verkko-operaattorien välillä. Täten myös konvertterivalmistajan täytyy olla selvillä käytössä olevista verkkomääräyksistä ja standardeista.
Resumo:
A sensitive and simple system was proposed for the in situ measurement of total aldehyde in outdoor or indoor ambient. The method is based on the use of a reagent drop as an useful interface to preconcentrate the sample prior to determination of total aldehyde as formaldehyde. The drop is formed at the tip of a cylindrical tube that contains two optical fibers placed on opposite sides and in contact with the reagent solution. One optical fiber carries the red light to the drop form a light emitting diode (LED). The transmitted light is measured by a second optical fiber/photodiode system. The analytical signal is read and converted into absorbance. The reagent solution of 3-methyl-2-benzothiazoline hydrazone (MBTH) forms a blue cation during reaction with formaldehyde that can be measured at 660 nm. Some aspects of kinetics reaction formation of dye were reevaluated. The formaldehyde reacts with MBTH and forms the azine in about 12 min. The oxidation of MBTH by Fe (III) and the formation of dye requires 3 min. The absorbance of the reagent drop is proportional to the sampling time and to the analyte concentration. The absorbance signal increases with increased sample gas flow until a maximum is reached then decreases until it forms a plateau. The proposed method was evaluated using both outdoor and indoor samples, and it was shown to viable provide an accurate measure of total aldehyde.
Resumo:
A través de este proyecto final de carrera se pretende analizar la viabilidad técnica y económica para la puesta en marcha de un hotel de montaña en una comarca concreta del Pirineo Aragonés, como alternativa de negocio. Aunque no podemos olvidar que es un sector que puede parecer saturado, se tratará de buscar el elemento diferenciador para superar esta amenaza competitiva. Desde el año 2000, el número total de turistas que llegan a España, ha ido ascendiendo año a año, hasta alcanzar valores máximos en 2007 y de nuevo en 2013. Las estadísticas demuestran que es un sector al alza y en la comunidad aragonesa aporta al PIB aragonés, cerca de 3.000 millones de euros. Por otro lado, la crisis ha provocado una bajada importante en los precios de los inmuebles y parcelas, por lo que nos aprovecharemos de esta oportunidad de negocio. A través de otros estudios que implementan el trabajo, llegamos a los resultados del análisis que demuestran que la inversión es posible. La modalidad escogida para la construcción y diseño del hotel, el efecto diferenciador en los productos y servicios ofertados y la cercanía del hotel de las estaciones de esquí, hacen posible el sueño de los futuros promotores, que apuestan por un tipo de negocio sostenible e integrado en la naturaleza y que respete la autenticidad sociocultural de la comarca y el entono.
Resumo:
This study illustrates the different types of plate heat exchangers that are commonly used in various domestic and industrial applications. The main purpose of this paper was to devise a methodology that is capable of calculating optimum number of plates in the design of a plate heat exchanger. To obtain the appropriate number of plates, typically several iterations must be made before a final acceptable design is completed, since plate amount depends on many factors such as, flow velocities, physical properties of the streams, flow channel geometry, allowable pressure drop, plate dimensions, and the gap between the plates. The methodology presented here can be used as a general guide for designing a plate heat exchanger. To investigate the effects of relevant parameters on the thermal-hydraulic design of a plate heat exchanger, several experiments were carried out for single-phase and counter flow arrangement with two brazed plate heat exchangers by varying the flow rates and the inlet temperatures of the fluid streams. The actual heat transfer coefficients obtained based on the experiment were nearly close to the calculated values and to improve the design, a correction factor was introduced. Besides, the effect of flow channel velocity on the pressure drop inside the unit is presented.
Resumo:
The discussion based on surfactant cleaning action is commonly used in chemistry classrooms for the comprehension of theoretical concepts related to surface tension and micelle formation. The experimental quantification of surface tension of aqueous solutions of surfactants provides the practical instruments for this discussion. The present paper describes a simplification on the common apparatus employed for the drop-weight method, making the determination of surface tension accessible to any chemistry lab. The surface tension of various liquids and the critical micelle concentration, CMC, of three commercial surfactants were measured with this modified method, and proved to be consistent with literature values.
Resumo:
Al2O3 is the most abundantly produced nanomaterial and has been used in diverse fields, including the medical, military and industrial sectors. As there are concerns about the health effects of nanoparticles, it is important to understand how they interact with cells, and specifically with red blood cells. The hemolysis induced by three commercial nano-sized aluminum oxide particles (nanopowder 13 nm, nanopowder <50 nm and nanowire 2-6 nm × 200-400 nm) was compared to aluminum oxide and has been studied on erythrocytes from humans, rats and rabbits, in order to elucidate the mechanism of action and the influence of size and shape on hemolytic behavior. The concentrations inducing 50% hemolysis (HC50) were calculated for each compound studied. The most hemolytic aluminum oxide particles were of nanopowder 13, followed by nanowire and nanopowder 50. The addition of albumin to PBS induced a protective effect on hemolysis in all the nano-forms of Al2O3, but not on Al2O3. The drop in HC50 correlated to a decrease in nanomaterial size, which was induced by a reduction of aggregation Aluminum oxide nanoparticles are less hemolytic than other oxide nanoparticles, and behave differently depending on the size and shape of the nanoparticles. The hemolytic behavior of aluminum oxide nanoparticles differs from that of aluminum oxide.
Resumo:
This study assessed ontogenetic dietary changes in male South American fur seals Arctocephalus australis in northern and central Patagonia (Argentina) using stable isotope ratios (δ15 N and δ13 C) in vibrissae and bones. Sucking pups were characterised by higher δ15 N values and lower δ13 C values than older specimens. Weaning was associated with a marked drop of δ15 N values, both in bone and vibrissae. Such a drop was inconsistent with the consumption of local prey and may reveal movement to distant foraging grounds or physiological changes associated with either fasting or rapid growth. Stable isotope ratios indicated that juveniles fed more pelagically than subadults and adults, but that there were no major differences between the 2 latter age categories. As subadults and adults are rather similar in body mass and are much larger than juveniles, body mass may play a role in the ontogenetic dietary changes reported. Nevertheless, demersal benthic prey were always scarce in the diet of male fur seals, which relied primarily on Argentine shortfin squid and small pelagic fish throughout life, though adults also consumed large amounts of decapod crustaceans available at shallow depths. Vibrissae did not reveal regular oscillations of δ15 N or δ13 C, except in 1 individual. Thus, male fur seals from northern and central Patagonia do not appear to migrate regularly between isotopically distinct areas, although nomadic displacements cannot be ruled out.
Resumo:
Due to the overwhelming international evidence that stock prices drop by less than the dividend paid on ex-dividend days, the ex-dividend day anomaly is considered a stylized fact. Two main approaches have emerged to explain this empirical regularity: the tax-clientele hypothesis and the microstructure of financial markets. Although the most widely accepted explanation for this fact relies on taxes, the ex-dividend day anomaly has been reported even in countries where neither dividends nor capital gains are taxed. The 2006 tax reform in Spain established the same tax rate for dividends and capital gains. This paper investigates stock returns on ex-dividend days in the Spanish stock market after the 2006 tax reform using a random coefficient model. Contrary to previous research, we do not observe an ex-dividend day anomaly. Unlike previous investigations, which are mostly concerned with suggesting explanations as to why this anomaly has occurred, we are in the somewhat strange position of discussing why this anomaly has not occurred. Our findings are robust across companies and stock dividend yields, thus supporting a tax--based explanation for the ex-dividend day anomaly.
Resumo:
The aim of this work is to discuss selected applications of electroanalytical techniques for the detection of pesticides in foods and beverages, published in the last ten years. The applications involved different working electrodes for the electroanalytical determination of pesticides, namely amperometric biosensors, cholinesterase-based biosensors, polymer-modified electrodes, ultramicroelectrodes and hanging mercury drop electrodes. They were used for several voltammetric and amperometric techniques in different analytical procedures for the detection and quantification of different classes of pesticides in different food matrices.
Resumo:
Al2O3 is the most abundantly produced nanomaterial and has been used in diverse fields, including the medical, military and industrial sectors. As there are concerns about the health effects of nanoparticles, it is important to understand how they interact with cells, and specifically with red blood cells. The hemolysis induced by three commercial nano-sized aluminum oxide particles (nanopowder 13 nm, nanopowder <50 nm and nanowire 2-6 nm × 200-400 nm) was compared to aluminum oxide and has been studied on erythrocytes from humans, rats and rabbits, in order to elucidate the mechanism of action and the influence of size and shape on hemolytic behavior. The concentrations inducing 50% hemolysis (HC50) were calculated for each compound studied. The most hemolytic aluminum oxide particles were of nanopowder 13, followed by nanowire and nanopowder 50. The addition of albumin to PBS induced a protective effect on hemolysis in all the nano-forms of Al2O3, but not on Al2O3. The drop in HC50 correlated to a decrease in nanomaterial size, which was induced by a reduction of aggregation Aluminum oxide nanoparticles are less hemolytic than other oxide nanoparticles, and behave differently depending on the size and shape of the nanoparticles. The hemolytic behavior of aluminum oxide nanoparticles differs from that of aluminum oxide.
Resumo:
Natriumhypokloriittia voidaan valmistaa kloorista ja lipeästä jatkuvatoimisessa absorberissa. Tässä työssä tutkittiin kokeellisesti, miten kaasun ja nesteen virtausnopeudet vaikuttavat täytekappalekolonnin tulvimiseen ja painehäviöön, kuinka nopeasti kloori absorboituu lipeään ja kuinka suuri hypokloriittiliuoksen kierrätys tarvitaan, ettei hypokloriitti ala hajota. Lisäksi luotiin matemaattinen malli, jolla voidaan mitoittaa jatkuvatoiminen vastavirtaperiaatteella toimiva natriumhypokloriittireaktori. Kloori–lipeäsysteemin havaittiin tulvivan suuremmilla virtausnopeuksilla kuin ilma–vesisysteemin. Tosin osa kloorista absorboituu jo ennen täytekappalekerrosta, minkä vuoksi kaasun todellinen virtausnopeus täytekappalekerroksen alaosassa on pienempi kuin mitattu arvo. Kolonnin painehäviö nousee erittäin jyrkästi tulvimispisteen läheisyydessä. Koska kloori absorboituu lähes täydellisesti ja vain kolonnin alaosa tulvii, voidaan kolonnia painehäviön kannalta operoida lähellä tulvimispistettä. Sekä mallinnuksen että koetulosten perusteella yli 99,99 % kloorista absorboituu koeolosuhteissa kahden metrin täytekappalekerroksessa. Nopea absorptio johtuu erittäin nopeasta, irreversiibelistä kloorin reaktiosta ja prosessille tyypillisestä natriumhydroksidikonversion rajoittamisesta alle 94 %:iin. Jotta varmistetaan, ettei hypokloriitti ala hajota, valmista hypokloriittiliuosta täytyy kierrättää kolonniin vähintään noin 4-kertainen määrä tuoreen lipeän syöttömäärän nähden.
Resumo:
Tämä diplomityö tutkii korroosionestoa polymeerin ekstruusiolinjalla. Kirjallisuusosassa käsitellään ekstruusiolinjaa, linjalla valmistettavia tuotteita ja niiden jatkojalostusta. Lisäksi kirjallisuusosassa käydään läpi linjalla ilmeneviä korroosiotyyppejä, korroosiota eri prosessilaitteissa, korroosionestossa käytettäviä inhibiittoreita ja eri materiaalien korroosiokestävyyden kartoitusta. Kokeellisessa osassa tutkittiin perushartsin kuivauksen vaikutusta ekstruuderin kaasutilan metanoli-, happi- ja kosteuspitoisuuksiin. Kokeellisessa osassa tutkittiin myös korroosioinhibiittorien I1 ja I2 vaikutusta korroosionestoon, seuraamalla korrodoivalla alueella olleiden ruuvielementtien painohäviöitä. Kaapelitestauksessa selvitettiin inhibiittorien käytön vaikutukset matalajännitekaapelin laatuun. Kuivauksella ei todettu olevan vaikutusta korroosionestoon. Metanolipitoisuus pysyi korkeana ja happipitoisuuden aleneminen ei ollut merkittävää. Kosteuspitoisuuden suuruusluokka selvitettiin. Kuivauksesta huolimatta se pysyi korkeana. Inhibiittorien käytöstä huolimatta ruuvielementit korrodoituivat, mutta inhibiittoria I2 käytettäessä tutkittujen ruuvielementtien painohäviöt olivat pienempiä referenssiajoon verrattuna. Inhibiittori I2:lla ei todettu olevan negatiivisia vaikutuksia matalajännitekaapelin laatuun suoritetuissa ikääntymis- sähköominaisuus- ja ristisilloittumisnopeustesteissä.
Resumo:
Tässä diplomityössä käydään läpi IEC-60534 -standardin mukainen säätöventtiilin mitoitus kokoonpuristumattomille ja –puristuville virtauksille laskennassa tarvittavine yhtälöineen. Teoreettisessa osassa esitellään RF-letkuventtiilien rakennetta ja ominaisuuksia. Lisäksi käydään läpi putkivirtauksen perusperiaatteita. Koska letkuventtiilissä virtaavana fluidina on usein jokin liete, on työssä esitelty menetelmä lietevirtauksen aiheuttaman paine-eron laskentaan. Työssä on käsitelty myös kavitaation syntyä, laskennalliset mahdollisuudet kavitaation ennustamiseen sekä keinoja kavitaation estämiseksi. Kokeellisessa osassa suoritettiin mittauksia kolmella erikokoisella RF-letkuventtiilillä, joissa kussakin käytettiin kolmea erityyppistä letkua. Mittausten perusteella pystyttiin laskemaan kapasiteettikertoimet sekä määrittämään säätökäyrät mitatuille venttiileille ja letkutyypeille. Näistä tuloksista säätökäyrille sovitettiin yhtälöt, joiden perusteella saatiin laskettua kapasiteettikertoimien arvot myös muille venttiilikoille.
Resumo:
Surface tension knowledge of surfactants aqueous solutions is important during amphiphilic molecule manufacturing and new product development, as feedback information to handle synthesis parameters to target performance. Drop counting method is an interesting simplification of drop weight method for surface tension measurements. A simple laboratory measurement device, with capability for temperature control, was assembled to allow investigation of ethoxylated surfactants. The implementation of the method was preceded by a detailed investigation of two factors that may affect the measured surface tension: drop formation velocity and surfactant ethoxylation degree. The limitations of the method are discussed on this basis.