967 resultados para Sensor array processing
Resumo:
This dissertation analyzes the possibilities of utilizing speech-processing technologies to transform the user experience of ActivoBank’s customers while using remote banking solutions. The technologies are examined through different criteria to determine if they support the bank’s goals and strategy and whether they should be incorporated in the bank’s offering. These criteria include the alignment with ActivoBank’s values, the suitability of the technology providers, the benefits these technologies entail, potential risks, appeal to the customers and impact on customer satisfaction. The analysis suggests that ActivoBank might not be in a position to adopt these technologies at this point in time.
Resumo:
The need for more efficient illumination systems has led to the proliferation of Solid-State Lighting (SSL) systems, which offer optimized power consumption. SSL systems are comprised of LED devices which are intrinsically fast devices and permit very fast light modulation. This, along with the congestion of the radio frequency spectrum has paved the path for the emergence of Visible Light Communication (VLC) systems. VLC uses free space to convey information by using light modulation. Notwithstanding, as VLC systems proliferate and cost competitiveness ensues, there are two important aspects to be considered. State-of-the-art VLC implementations use power demanding PAs, and thus it is important to investigate if regular, existent Switched-Mode Power Supply (SMPS) circuits can be adapted for VLC use. A 28 W buck regulator was implemented using a off-the-shelf LED Driver integrated circuit, using both series and parallel dimming techniques. Results show that optical clock frequencies up to 500 kHz are achievable without any major modification besides adequate component sizing. The use of an LED as a sensor was investigated, in a short-range, low-data-rate perspective. Results show successful communication in an LED-to-LED configuration, with enhanced range when using LED strings as sensors. Besides, LEDs present spectral selective sensitivity, which makes them good contenders for a multi-colour LED-to-LED system, such as in the use of RGB displays and lamps. Ultimately, the present work shows evidence that LEDs can be used as a dual-purpose device, enabling not only illumination, but also bi-directional data communication.
Resumo:
Nesta dissertação é apresentada a metodologia adoptada no desenvolvimento de um sensor capaz de monitorizar a evolução da consolidação óssea proveniente de patologias tratadas com a utilização de aparelhos de fixação externa. O sensor tem como finalidade medir o deslocamento relativo entre os componentes do fixador externo que são proporcionais aos níveis de consolidação do osso. Surge como alternativa aos processos convencionais (raios-X, ultra-sons, etc.) que não possibilitam a detecção de imperfeições no processo de regeneração óssea numa fase precoce. Uma análise a vários materiais e geometrias revelaram que um sensor fabricado em latão e sob a forma de anel, após uma deformação de compressão de 4
Resumo:
This work reviews the recent research on ion and UV irradiation of β-
Resumo:
The growing need to patrol and survey large maritime and terrestrial areas increased the need to integrate external sensors on aircraft in order to accomplish those patrols at increasingly higher altitudes, longer range and not depending upon vehicle type. The main focus of this work is to elaborate a practical, simple, effective and efficient methodology for the aircraft modification procedure resulting from the integration of an Elec-tro-Optical/Infra-Red (EO/IR) turret through a support structure. The importance of the devel-opment of a good methodology relies on the correct management of project variables as time, available resources and project complexity. The key is to deliver a proper tool for a project de-sign team that will be used to create a solution that fulfils all technical, non-technical and certi-fication requirements present in this field of transportation. The created methodology is inde-pendent of two main inputs: sensor model and aircraft model definition, and therefore it is in-tended to deliver the results for different projects besides the one that was presented in this work as a case study. This particular case study presents the development of a structure support for FLIR STAR SAPHIRE III turret integration on the front lower fuselage bulkhead (radome) of the LOCKHEED MARTIN C-130 H. Development of the case study focuses on the study of local structural analysis through the use of Finite Element Method (FEM). Development of this Dissertation resulted in a cooperation between Faculty of Science and Technology - Universidade Nova de Lisboa and the company OGMA - Indústria Aeronáutica de Portugal
Resumo:
RESUMO: Os mais recentes métodos de neuro imagem tal como a Ressonância Magnética (RM) permitiram obter imagens detalhadas do cérebro humano in vivo. Essas imagens revelam, muitas vezes, achados imprevistos face ao padrão normal, com elevada propensão para os indivíduos idosos e franca coexistência com fatores de risco vascular, como característica dum processo de envelhecimento normal. Embora na última década tenham surgido várias publicações sobre este assunto, ele continua ainda pouco explicado. Um pouco por todo o mundo têm emergido os programas de prevenção da doença e promoção da saúde desenvolvidos pela Saúde Pública suportadas sobretudo pelo avanço das tecnologias médicas que resultaram, entre outros impactos, num crescimento da população idosa. Estima-se, em 2030, uma composição demográfica com 20% de indivíduos acima dos 65 anos. Neste contexto, a doença microvascular cerebral é a causa mais frequente de comprometimento cognitivo vascular no idoso sendo as características senescentes na imagem por RM do tipo lesões isquémicas da Substância Branca (Leukoaraiosis) e enfartes lacunares (Status lacunar), atrofia cerebral, gliose e acumulação excessiva de ferro nos núcleos da base. Esta tese, considerando a linha de investigação de que deriva – Ciências da Vida - especialização em Medicina Clinica - Biotecnologia, reúne e reflete sobre três vertentes ligadas à RM e interdependentes em relação a uma problemática comum. A primeira trata da caracterização da Tecnologia por Ressonância Magnética existente em Portugal, a qual inclui uma avaliação exploratória da aplicação da técnica de Difusão Anisotrópica nos estudos cerebrais. As dimensões analíticas estudadas foram a Tecnológica, Sociodemográfica e Económica. Na recolha de dados recorreu-se a várias fontes de informação e a uma metodologia exploratória faseada, validada pela triangulação dos resultados. A sua análise obedeceu a critérios de estratificação e agrupamento segundo as mesmas dimensões analíticas. Otimização da anisotropia fronto-calosa e [RM 1,5T] no idoso normal e com risco cérebro-vascular A segunda descreve o estudo anátomo – radiológico que recaiu sobre parâmetros de quantificação assente na temática do cérebro do idoso em cadáver segundo uma metodologia experimental aplicada às métricas da difusão por RM. Na terceira, e última, é apresentado o estudo técnico - radiológico para avaliação e otimização da imagem ponderada em difusão em estudos clínicos associados ao cérebro do idoso “The Usual Brain Aging” ou Envelhecimento Cerebral Normal, com base metodológica assente nos critérios e indicadores estabelecidos pelo Estudo de Imagem de Roterdão (Rotterdam Scan Study - RSS). Como principais resultados obteve-se que não existem em Portugal estruturas para avaliação dos equipamentos pesados ou Agência de Avaliação das Tecnologias da Saúde para desenvolver o importante papel da produção de estudos comparativos entre os equipamentos disponíveis no mercado, a relação preço-qualidade e a sua afetação às necessidades clínico-epidemiológicas. Constatou-se que a implementação de equipamentos de RM está fortemente assente em critérios económicos carecendo de recomendações e diretivas para o uso racionalizado destas tecnologias. Quanto a dados quantitativos concluímos que a maioria dos equipamentos está instalada em instituições privadas (80,2%); a intensidade de campo magnético mais frequente é [1,5T] com 119 equipamentos; os equipamentos estão instalados maioritariamente nos distritos de Lisboa (55 unidades) e do Porto (39 unidades); o rácio médio de equipamentos por habitante em Portugal é de 1 para 65 195 habitantes; a amplitude de gradientes com maior expressão na amostra é 30-39mT/m; a maioria dos equipamentos foi instalada no intervalo temporal [2009-2012] com 59 equipamentos; apenas 6 instituições desenvolvem investigação clinica e a maioria das bobinas para estudos de crânio são do tipo Array. O estudo de otimização da técnica da difusão revelou, quanto à avaliação dos valoresb, que os mais baixos (b=500 s/mm2 e b=1000 s/mm2), apresentam maior IS e SNR sendo esta uma boa medida referente à qualidade de imagem, no entanto, os valores-b mais elevados (b=2000 s/mm2) apresentam maior CNR e CR, face aos anteriores, o Otimização da anisotropia fronto-calosa e [RM 1,5T] no idoso normal e com risco cérebro-vascular que apesar de proporcionar inferior detalhe anatómico e consequentemente inferior qualidade de imagem, num encéfalo normal, pode auxiliar na interpretação e apresentar vantagens na identificação de lesões microvasculares sempre que persistirem dúvidas em relação ao diagnóstico diferencial de doença microvascular do tipo status lacunar ou Hiperintensidades da Substância Branca. As alterações deste parâmetro são particularmente refletidas nas diferenças da avaliação da qualidade de imagem na região fronto-calos Concluímos da avaliação quantitativa da concentração média de ferro (26Fe) em todas as faixas etárias que os núcleos da base que apresentam maior concentração são, por ordem decrescente: Substância Nigra, Globus Pallidus, Putamen, Tálamo, Núcleo Rubro e Núcleo Caudado; que existe uma predominância na concentração de ferro (26Fe) no hemisfério esquerdo e que os indivíduos do género masculino apresentam mais ferro (26Fe) que os do género feminino nas faixas etárias [30-40[, [40-50[ e [50-60[. Como principal conclusão do estudo da concentração média de ferro em relação à idade destacamos que a concentração média de ferro (26Fe) é superior nos grupos etários superiores, logo aumenta com a idade, sobretudo na Substância Nigra e no Núcleo Lenticular. No estudo técnico-radiológico encontrámos evidências do aumento da difusibilidade da água na substância branca subcortical dos sujeitos idosos comparativamente aos mais jovens. Uma relação idêntica foi avaliada nos tálamos. O aumento relacionado com a idade parece ser predominantemente observado em doentes com mais de 65 anos de idade o que pode refletir alterações estruturais ligeiras associados ao envelhecimento normal. Os resultados indicam que a análise quantitativa das imagens ponderadas em difusão fornece informações, sobre a estrutura do cérebro, as quai s não estão disponíveis apenas por inspeção visual, tanto nas imagens ponderadas em difusão como em outras sequências de aplicação clínica de rotina. Para fazer face às desvantagens dos sistemas de quantificação das HSB os quais são dispendiosos, complexos, requererem tecnologia e formação específicas, recomendamos que a aplicação automatizada GUIAL, desenvolvida ao longo do nosso trabalho é de utilização elementar e prática para que seja introduzida nos sistemas de aquisição de imagem por RM com o fim de integrar o processamento de imagem nos indivíduos portadores de fatores de risco vascular. A avaliação do ADC, nesta amostra, permitiu concluir que a variação desta variável é explicada estatisticamente pela existência da condição clínica de status lacunar em ambos os hemisférios ou por outras palavras, o status lacunar influencia o valor de ADC. Embora uma pequena percentagem da variação do ADC seja explicada pelo género, o ADC nos homens foi superior ao das mulheres o que não nos surpreende, pois são também os homens onde a frequência de doença microvascular se revelou mais expressiva. Os valores do ADC, globalmente, entre os hemisférios cerebrais não mostraram alterações exceto na SB entre os idosos e não idosos. A SB da região frontal mostrou valores diminuídos na anisotropia e isotropia face às restantes áreas anatómicas. Os estudos indicam que na idade avançada existe uma maior predisposição para suscetibilidades de estrutura com status de desconexão. A classificação das HSB foi superior em indivíduos mais velhos e com status lacunar, e em menor quantidade (inferior rating de classificação) nos indivíduos idosos sem status lacunar. As alterações volumétricas foram mais frequentes no homem do que na mulher, presumivelmente devido à associação com a elevada classificação de status lacunar. Um aumento do índice de Evan correspondeu, neste estudo, ao aumento das HSB, à diminuição do volume cerebral total, à expansão ventrículo-sulcal frontal e ao aumento da medida do ângulo caloso. Estes resultados foram agravados pela classificação elevada de status lacunar nos indivíduos que apresentaram indícios de doença de pequenos vasos, com manifesto aumento dos espaços de Virchow-Robin,enfartes lacunares ou HSB. Esses resultados foram mais expressivos no género masculino do que no feminino revelando uma maior vulnerabilidade sobretudo na atrofia frontal nos homens. Por sua vez as dimensões do Corpo Caloso tornaram-se reduzidas devido à compressão dos ventrículos laterais e terceiro ventrículo. Estes indicadores tiveram expressão particularmente nos indivíduos com mais de 65 anos. ---------------------------------------------------------------------------------------------ABSTRACT: The latest neuroimaging methods, such as Magnetic Resonance Imaging (MRI), have enabled detailed images of in vivo human brain. These images reveal often unexpected findings related to the normal pattern, with high predisposition for the elderly people with forthright coexistence with vascular risk factors such as characteristics of a normal aging process. Although it has been, in the last decade, several publications on this subject, it is still little explained. All over the world have emerged disease prevention programs and health promotion developed by the Public Health sector, supported mainly by the advancement of medical technologies that have resulted, among other impacts, in a growing of the elderly population. It is estimated, in 2030, a demographic composition with 20% o people over 65 years. In this context, microvascular disease is the most common cause of cognitive vascular impairment in the elderly and senescent characteristics in the MRI trough ischemic lesions of the white matter (Leukoaraiosis) and lacunar infarcts (lacunar status), cerebral atrophy, gliosis and iron accumulation in the basal ganglia in excess.This thesis, considering the research line that stems - Life Sciences - specialization in Clinical Medicine, Biotechnology, gathers and reflects on three aspects linked to MR, interdependent and related to a common problem. The first deals with the Magnetic Resonance Technology characterization in Portugal, which includes an exploratory evaluation of the implementation of Anisotropic Diffusion technique in brain studies. The analytical dimensions studied were the Technologic, Socio-demographic and Economics. Collecting data was supported by different sources of information and was applied an exploratory methodology whose results were validated by triangulation. The research method was grouped and stratified criteria under the same analytical dimensions. The second describes the anatomical study - which was focused on radiological measurement parameters, based on the brain’s specimen under an experimental methodology applied to MRI diffusion metrics. Radiological evaluation and optimization of the weighted image diffusion in clinical studies were associated with the brain of the elderly "The Usual Brain Aging" with methodological basis based on established criteria and indicators by Rotterdam Scan Study (RSS). The main results obtained reveal the inexistence frameworks in Portugal for evaluation of equipments or Agency of Health Technology to produce studies comparing the equipment available on the market, the value for money and its allocation to clinical and epidemiological needs. It was found that the implementation of MRI equipment is strongly based on economic criteria lacking recommendations and guidelines for the rationalized use of these technologies. As the quantitative data we conclude that most of the scanners are located in private clinical institutions (80,2%); the most frequent magnetic field intensity is [1.5T] with 119 scanners; the scanners are mainly installed in Lisbon (55 units) and Porto (39 units) districts; the average ratio of equipment per capita in Portugal is 1 to 65 195 people; the gradient power with higher expression in the sample is 30-39mT / m;most of the scanners were installed in the years range [2009-2012 years] with 59 equipment; only 6 clinical placements develop clinical research and the most coils for brain studies are of Array type. The optimization study of diffusion technique revealed, as the assessment of the bvalues, the lower (b = 500 s / mm2 and b = 1000 s / mm 2), promotes an increase in the SI and SNR being this measure related to a higher image quality, however the highest b values (b = 2000 s / mm 2) have a higher CNR (Contrast to Noise-Ratio) and CR (Contrast Ratio), compared to the previous ones. This may provide less anatomical details and, thus, ower image quality, of a normal brain, however can help the interpretation and have advantages in identifying microvascular injuries when doubts persist regarding the differential diagnosis of microvascular disease of lacunar or WMH (White Matter Hyperintensities) status type. Changes on this parameter are Otimização da anisotropia fronto-calosa e [RM 1,5T] no idoso normal e com risco cérebro-vascular particularly reflected in the differences of image quality evaluation in the frontocallosum anatomical area. We conclude from the quantitative assessment of the average concentration of iron (26Fe), in all age groups to the basal ganglia, that the higher concentrations are, in descending order: Nigral Substantia, Globus pallidus, Putamen, Thalamus, Rubio nucleus and Caudate nucleus; that there is a predominance in the concentration of iron (26Fe) in the left hemisphere and that male gender show higher iron (26Fe) level tha females, in the age groups [30-40 [[40-50 [and [50- 60 [. Regarding a main conclusion of the mean concentration study of iron, in terms of age we point out that the average concentration of iron (26Fe) is higher among older groups and increases with age, especially in Nigral Substantia and Lenticular Nucleus. On the technical and radiological study we found evidence of an increased in water /diffusivity in the ubcortical white matter of the elderly compared with younger subjects. A similar relationship was assessed in the Thalamus. The increase agerelated seems to be predominantly observed in patients over 65 years which may reflect minor structural changes associated with normal aging. The results indicate that quantitative analysis of diffusion weighted imaging can provide information about the structure of the brain which is not reached only by visual inspection or standard sequences applied in clinical routine. To address the disadvantages the systems of quantification of WMH which the authors state that are costly, complex, require specific technology and training, we recommend that the automated application GUIAL, developed over our work is basic and practical to use and to be introduced in MR image systems acquisition in order to integrate image processing in patients with vascular risk factors. The evaluation of the ADC showed that its variation is statistically explained by the existence of the medical condition of lacunar status, in both hemispheres, or in other words, the lacunar status influences the ADC value. Although a small percentage of the ADC variation is explained by gender, the ADC in men was higher than women which Otimização da anisotropia fronto-calosa e [RM 1,5T] no idoso normal e com risco cérebro-vascular do not surprise us, since they are also men where the frequency of microvasculardisease has proved more significant. The values of ADC, overall, between the cerebral hemispheres showed no changes but were different in WM among the elderly and non-elderly subjects.The WM's forehead showed decreased values in anisotropy and isotropy face the other anatomical areas. The studies indicate that in old age there is a greater tendency to higher susceptibility to disconnection- status framework. The classification of WMH was higher in elderly people and lacunar status, and fewer (lower classification rating) in the elderly without lacunar status. volumetric changes were more frequent in men than in women, most probably because of its association with high lacunar status rating. An increase of Evan index corresponded, in this study, to an increase in WMH, to a decreased of total brain volume, to a ventricle sulcal frontal and callous angle expansion. These results were wound up by high ranking of lacunar status in subjects who had small vessel disease, clear increase in spaces of Virchow-Robin, lacunar infarctions or WMH. These results were more significant in males than in females revealing vulnerability particularly in the frontal atrophy in men. In turn the size of Corpus Callosum because reduced due to the compression of the lateral and third ventricles. These indicators had expression particularly in individuals over 65 years.
Resumo:
Programa Doutoral em Engenharia Têxtil.
Resumo:
As increasingly more sophisticated materials and products are being developed and times-to-market need to be minimized, it is important to make available fast response characterization tools using small amounts of sample, capable of conveying data on the relationships between rheological response, process-induced material structure and product characteristics. For this purpose, a single / twin-screw mini-extrusion system of modular construction, with well-controlled outputs in the range 30-300 g/h, was coupled to a in- house developed rheo-optical slit die able to measure shear viscosity and normal-stress differences, as well as performing rheo-optical experiments, namely small angle light scattering (SALS) and polarized optical microscopy (POM). In addition, the mini-extruder is equipped with ports that allow sample collection, and the extrudate can be further processed into products to be tested later. Here, we present the concept and experimental set-up [1, 2]. As a typical application, we report on the characterization of the processing of a polymer blend and of the properties of extruded sheets. The morphological evolution of a PS/PMMA industrial blend along the extruder, the flow-induced structures developed and the corresponding rheological characteristics are presented, together with the mechanical and structural characteristics of produced sheets. The application of this experimental tool to other material systems will also be discussed.
Resumo:
Técnicas de sensoriamento remoto são fundamentais para o monitoramento das mudanças de uso da terra, principalmente em áreas extensas como a Amazônia. O mapeamento de uso da terra, geralmente é realizado por métodos de classificação manual ou digital pixel a pixel, os quais consomem muito tempo. Este estudo aborda a aplicação do modelo linear de mistura em uma imagem Landsat-TM segmentada para o mapeamento das classes de uso da terra na região do reservatório de Tucuruí-PA para os anos de 1996 e 2001.
Resumo:
O objetivo desta pesquisa foi avaliar os dados do sensor MODIS para detectar e monitorar cicatrizes de áreas recém queimadas. Utilizamos imagens da reflectância de superfície do sensor MODIS: produto MOD09 (dia 5 de outubro) e produto MOD13A1 (meses de outubro e novembro). Foi avaliada também uma série temporal de um ano dos índices de vegetação (IV) EVI e NDVI (produto MOD13A1). Uma imagem do sensor ETM+ (dia 5 de outubro) foi utilizada como base para a delimitação dos polígonos amostrais e avaliação dos dados MODIS devido a sua melhor resolução espacial. A metodologia focou na aplicação do modelo linear de mistura espectral nas imagens reflectância para a geração das imagens fração sombra. Análises de regressão foram efetuadas para comparação entre o percentual de sombra derivado da imagem ETM+ e das imagens MODIS. As alterações multitemporais nas imagens IV foram avaliadas com base no teste de Tukey. Os resultados mostraram que a imagem fração sombra gerada a partir do produto MOD09 apresentou um R² = 0,66 (p < 0,01) em relação aos dados ETM+. Para as imagens do produto MOD13A1 não foram identificadas relações significativas. Os IV dentro dos mesmos polígonos apresentaram uma variação sazonal durante o ano. No entanto, não houve uma diminuição significativa dos valores destes índices nos meses onde foram observadas as cicatrizes de áreas recém queimadas. Portanto, o produto MOD09 mostrou-se mais eficiente que o produto MOD13A1 para a detecção de cicatrizes de áreas recém queimadas. A análise multitemporal dos IV sugeriu que não foi possível detectar este mesmo padrão na área de estudo.
Resumo:
Wool and silk are major protein fiber materials used by the textile industry. Fiber protein structure-function relationships are briefly described here, and the major enzymatic processing routes for textiles and other novel applications are deeply reviewed. Fiber biomodification is described here with various classes of enzymes such as protease, transglutaminase, tyrosinase, and laccase. It is expected that the reader will get a perspective on the research done as a basis for new applications in other areas such as cosmetics and pharma.
Resumo:
Dissertação de mestrado integrado em Psicologia
Resumo:
Dissertação de mestrado integrado em Psicologia
Resumo:
Electroactive polymers are one of the most interesting class of polymers used as smart materials in various applications, such as the development of sensors and actuators for biomedical applications in areas such as smart prosthesis, implantable biosensors and biomechanical signal monitoring, among others. For acquiring or applying the electrical signal from/to the piezoelectric material, suitable electrodes can be produced from Ti based coatings with tailored multifunctional properties, conductivity and antibacterial characteristics, through Ag inclusions. This work reports on Ag-TiNx electrodes, deposited by d. c. and pulsed magnetron sputtering at room temperature on poly(vinylidene fluoride), PVDF, the all-round best piezoelectric polymer.. Composition of the electrodes was assessed by microanalysis X-ray system (EDS - energy dispersive spectrometer). The XRD results revealed that the deposition conditions preserve the polymer structure and suggested the presence of crystalline fcc-TiN phase and fcc-Ag phase in samples with N2 flow above 3 sccm. According to the results obtained from SEM analysis, the coatings are homogeneous and Ag clusters were found for samples with nitrogen flow above 3 sccm. With increasing nitrogen flow, the sheet resistivity tend to be lower than the samples without nitrogen, leading also to a decrease of the piezoelectric response. It is concluded that the deposition conditions do significantly affect the piezoelectric polymer, which maintain its characteristics for sensor/actuator applications.
Resumo:
Stress/strain sensors constitute a class of devices with a global ever-growing market thanks to their use in many fields of modern life. They are typically constituted by thin metal foils deposited on flexible supports. However, the low inherent resistivity and limited flexibility of their constituents make them inadequate for several applications, such as measuring large movements in robotic systems and biological tissues. As an alternative to the traditional compounds, in the present work we will show the advantages to employ a smart material, polyaniline (PANI), prepared by an innovative environmentally friendly route, for force/strain sensor applications wherein simple processing, environmental friendliness and sensitivity are particularly required.