980 resultados para SPECT-CT


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine if multi–detector row computed tomography (CT) can replace conventional radiography and be performed alone in severe trauma patients for the depiction of thoracolumbar spine fractures. MATERIALS AND METHODS: One hundred consecutive severe trauma patients who underwent conventional radiography of the thoracolumbar spine as well as thoracoabdominal multi–detector row CT were prospectively identified. Conventional radiographs were reviewed independently by three radiologists and two orthopedic surgeons; CT images were reviewed by three radiologists. Reviewers were blinded both to one another’s reviews and to the results of initial evaluation. Presence, location, and stability of fractures, as well as quality of reviewed images, were assessed. Statistical analysis was performed to determine sensitivity and interobserver agreement for each procedure, with results of clinical and radiologic follow-up as the standard of reference. The time to perform each examination and the radiation dose involved were evaluated. A resource cost analysis was performed. RESULTS: Sixty-seven fractured vertebrae were diagnosed in 26 patients. Twelve patients had unstable spine fractures. Mean sensitivity and interobserver agreement, respectively, for detection of unstable fractures were 97.2% and 0.951 for multi–detector row CT and 33.3% and 0.368 for conventional radiography. The median times to perform a conventional radiographic and a multi–detector row CT examination, respectively, were 33 and 40 minutes. Effective radiation doses at conventional radiography of the spine and thoracoabdominal multi–detector row CT, respectively, were 6.36 mSv and 19.42 mSv. Multi–detector row CT enabled identification of 146 associated traumatic lesions. The costs of conventional radiography and multi–detector row CT, respectively, were $145 and $880 per patient. CONCLUSION: Multi–detector row CT is a better examination for depicting spine fractures than conventional radiography. It can replace conventional radiography and be performed alone in patients who have sustained severe trauma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim of this paper is to evaluate the diagnostic contribution of various types of texture features in discrimination of hepatic tissue in abdominal non-enhanced Computed Tomography (CT) images. Regions of Interest (ROIs) corresponding to the classes: normal liver, cyst, hemangioma, and hepatocellular carcinoma were drawn by an experienced radiologist. For each ROI, five distinct sets of texture features are extracted using First Order Statistics (FOS), Spatial Gray Level Dependence Matrix (SGLDM), Gray Level Difference Method (GLDM), Laws' Texture Energy Measures (TEM), and Fractal Dimension Measurements (FDM). In order to evaluate the ability of the texture features to discriminate the various types of hepatic tissue, each set of texture features, or its reduced version after genetic algorithm based feature selection, was fed to a feed-forward Neural Network (NN) classifier. For each NN, the area under Receiver Operating Characteristic (ROC) curves (Az) was calculated for all one-vs-all discriminations of hepatic tissue. Additionally, the total Az for the multi-class discrimination task was estimated. The results show that features derived from FOS perform better than other texture features (total Az: 0.802+/-0.083) in the discrimination of hepatic tissue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study is to define an optimally performing computer-aided diagnosis (CAD) architecture for the classification of liver tissue from non-enhanced computed tomography (CT) images into normal liver (C1), hepatic cyst (C2), hemangioma (C3), and hepatocellular carcinoma (C4). To this end, various CAD architectures, based on texture features and ensembles of classifiers (ECs), are comparatively assessed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a computer-aided diagnostic (CAD) system for the classification of hepatic lesions from computed tomography (CT) images is presented. Regions of interest (ROIs) taken from nonenhanced CT images of normal liver, hepatic cysts, hemangiomas, and hepatocellular carcinomas have been used as input to the system. The proposed system consists of two modules: the feature extraction and the classification modules. The feature extraction module calculates the average gray level and 48 texture characteristics, which are derived from the spatial gray-level co-occurrence matrices, obtained from the ROIs. The classifier module consists of three sequentially placed feed-forward neural networks (NNs). The first NN classifies into normal or pathological liver regions. The pathological liver regions are characterized by the second NN as cyst or "other disease." The third NN classifies "other disease" into hemangioma or hepatocellular carcinoma. Three feature selection techniques have been applied to each individual NN: the sequential forward selection, the sequential floating forward selection, and a genetic algorithm for feature selection. The comparative study of the above dimensionality reduction methods shows that genetic algorithms result in lower dimension feature vectors and improved classification performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To describe the most reliable insertion angle, corridor length and width to place a ventral transarticular atlantoaxial screw in miniature breed dogs. STUDY DESIGN: Retrospective CT imaging study. SAMPLE POPULATION: Cervical CT scans of toy breed dogs (n = 21). METHODS: Dogs were divided into 2 groups--group 1: no atlantoaxial abnormalities; group 2: atlantoaxial instability. Insertion angle in medial to lateral and ventral to dorsal direction was measured in group 1. Corridor length and width were measured in groups 1 and 2. Corridor width was measured at 3 points of the corridor. Each variable was measured 3 times and the mean used for statistical analysis. RESULTS: Mean +/- SD optimal transarticular atlantoaxial insertion angle was determined to be 40 +/- 1 degrees in medial to lateral direction from the midline and 20 +/- 1 degrees in ventral to dorsal direction from the floor of the neural canal of C2. Mean corridor length was 7 mm (range, 4.5-8.0 mm). Significant correlation was found between corridor length, body weight, and age. Mean bone corridor width ranged from 3 to 5 mm. Statistically significant differences were found between individuals, gender and measured side. CONCLUSIONS: Optimal placement of a transarticular screw for atlantoaxial joint stabilization is very demanding because the screw path corridor is very narrow.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Only limited data exists in terms of the incidence of intracranial bleeding (ICB) in patients with mild traumatic brain injury (MTBI). METHODS We retrospectively identified 3088 patients (mean age 41 range (7-99) years) presenting with isolated MTBI and GCS 14-15 at our Emergency Department who had undergone cranial CT (CCT) between 2002 and 2011. Indication for CCT was according to the "Canadian CT head rules." Patients with ICB were either submitted for neurosurgical treatment or kept under surveillance for at least 24 hours. Pearson's correlation coefficient was used to correlate the incidence of ICB with age, gender, or intake of coumarins, platelet aggregation inhibitors, or heparins. RESULTS 149 patients (4.8%) had ICB on CCT. No patient with ICB died or deteriorated neurologically. The incidence of ICB increased with age and intake of anticoagulants without clinically relevant correlation (R = 0.11; P < 0.001; R = -0.06; P < 0.001). CONCLUSION Our data show an incidence of 4.8% for ICB after MTBI. However, neurological deterioration after MTBI seems to be rare, and the need for neurosurgical intervention is only required in selected cases. The general need for CCT in patients after MTBI is therefore questionable, and clinical surveillance may be sufficient when CCT is not available.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Leptospirosis pulmonary haemorrhage syndrome (LPHS) is a frequent manifestation of Leptospira infection in dogs and is associated with a high morbidity and mortality. Three helical 16-slice thoracic CT scans were performed in 10 dogs naturally infected with Leptospira, within 24 hours of admission, and three and seven days later. Patients were sedated and scanned without breathhold, with a protocol adapted for rapid scanning. One dog died of respiratory failure on the morning following the first scan. On the initial scan, imaging features of LPHS included ground-glass nodules (10/10), peribronchovascular interstitial thickening (10/10), diffuse or patchy ground-glass opacity (9/10), solid nodules (8/10) and consolidation (7/10). Temporary bronchiolar dilation was observed in all dogs in association with peribronchovascular interstitial thickening, which had completely resolved at day 7. Nodules were with few exceptions assigned to the centrilobular region. Regression of lesion severity was observed after each subsequent scan. Consolidation and solid nodules changed over time into lesions of ground-glass attenuation. Pleural effusion (3/10) and mediastinal effusion (2/10) were mild and transient. Lesion severity appeared unassociated with survival to discharge.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Standard stroke CT protocols start with non-enhanced CT followed by perfusion-CT (PCT) and end with CTA. We aimed to evaluate the influence of the sequence of PCT and CTA on quantitative perfusion parameters, venous contrast enhancement and examination time to save critical time in the therapeutic window in stroke patients. METHODS AND MATERIALS Stroke CT data sets of 85 patients, 47 patients with CTA before PCT (group A) and 38 with CTA after PCT (group B) were retrospectively analyzed by two experienced neuroradiologists. Parameter maps of cerebral blood flow, cerebral blood volume, time to peak and mean transit time and contrast enhancements (arterial and venous) were compared. RESULTS Both readers rated contrast of brain-supplying arteries to be equal in both groups (p=0.55 (intracranial) and p=0.73 (extracranial)) although the extent of venous superimposition of the ICA was rated higher in group B (p=0.04). Quantitative perfusion parameters did not significantly differ between the groups (all p>0.18), while the extent of venous superimposition of the ICA was rated higher in group B (p=0.04). The time to complete the diagnostic CT examination was significantly shorter for group A (p<0.01). CONCLUSION Performing CTA directly after NECT has no significant effect on PCT parameters and avoids venous preloading in CTA, while examination times were significantly shorter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Discrepancies in finite-element model predictions of bone strength may be attributed to the simplified modeling of bone as an isotropic structure due to the resolution limitations of clinical-level Computed Tomography (CT) data. The aim of this study is to calculate the preferential orientations of bone (the principal directions) and the extent to which bone is deposited more in one direction compared to another (degree of anisotropy). Using 100 femoral trabecular samples, the principal directions and degree of anisotropy were calculated with a Gradient Structure Tensor (GST) and a Sobel Structure Tensor (SST) using clinical-level CT. The results were compared against those calculated with the gold standard Mean-Intercept-Length (MIL) fabric tensor using micro-CT. There was no significant difference between the GST and SST in the calculation of the main principal direction (median error=28°), and the error was inversely correlated to the degree of transverse isotropy (r=−0.34, p<0.01). The degree of anisotropy measured using the structure tensors was weakly correlated with the MIL-based measurements (r=0.2, p<0.001). Combining the principal directions with the degree of anisotropy resulted in a significant increase in the correlation of the tensor distributions (r=0.79, p<0.001). Both structure tensors were robust against simulated noise, kernel sizes, and bone volume fraction. We recommend the use of the GST because of its computational efficiency and ease of implementation. This methodology has the promise to predict the structural anisotropy of bone in areas with a high degree of anisotropy, and may improve the in vivo characterization of bone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To investigate the ex vivo performance of high-resolution computed tomography (CT) for quantitative assessment of percentage diameter stenosis in coronary arteries compared to histopathology. MATERIALS AND METHODS High-resolution CT was performed in 26 human heart specimens after the injection of iodinated contrast media into the coronary arteries. Coronary artery plaques were visually identified on CT images and the grade of stenosis for each plaque was measured with electronic calipers. All coronary plaques were characterized by histopathology according to the Stary classification, and the percentage of stenosis was measured. RESULTS CT depicted 84% (274/326) of all coronary plaques identified by histology. Missed plaques by CT were of Stary type I (n=31), type II (n=16), and type III (n=5). The stenosis degree significantly correlated between CT and histology (r=0.81, p<0.001). CT systematically overestimated the stenosis of calcified plaques (mean difference - 11.0 ± 9.5%, p<0.01) and systematically underestimated the stenosis of non-calcified plaques (mean difference -6.8 ± 10.4%, p<0.05), while there was no significant difference for mixed-type plaques (mean difference -0.4 ± 11.7%, p=0.85). There was a significant underestimation of stenosis degree as measured by CT for Stary II plaques (mean difference -14 ± 9%, p<0.01) and a significant overestimation for Stary VII plaques (mean difference 9 ± 10%, p<0.05), but there was no significant difference in stenosis degree between both modalities for other plaque types. CONCLUSIONS High-resolution CT reliably depicts advanced stage coronary plaques with an overall good correlation of stenosis degree compared to histology, however, the degree of stenosis is systematically overestimated in calcified and underestimated in non-calcified plaques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Angiographic C-arm CT may allow performing percutaneous stereotactic tumor ablations in the interventional radiology suite. Our purpose was to evaluate the accuracy of using C-arm CT for single and multimodality image fusions and to compare the targeting accuracy of liver lesions with the reference standard of MDCT. MATERIALS AND METHODS C-arm CT and MDCT scans were obtained of a nonrigid rapid prototyping liver phantom containing five 1-mm targets that were placed under skin-simulating deformable plastic foam. Target registration errors of image fusion were evaluated for single-modality and multimodality image fusions. A navigation system and stereotactic aiming device were used to evaluate target positioning errors on postinterventional scans with the needles in place fused with the C-arm CT or MDCT planning images. RESULTS Target registration error of the image fusion showed no significant difference (p > 0.05) between both modalities. In five series with a total of 25 punctures for each modality, the lateral target positioning error (i.e., the lateral distance between the needle tip and the planned trajectory) was similar for C-arm CT (mean [± SD], 1.6 ± 0.6 mm) and MDCT (1.82 ± .97 mm) (p = 0.33). CONCLUSION In a nonrigid liver phantom, angiographic C-arm CT may provide similar image fusion accuracy for comparison of intra- and postprocedure control images with the planning images and enables stereotactic targeting accuracy similar to that of MDCT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Respiratory motion causes substantial uncertainty in radiotherapy treatment planning. Four-dimensional computed tomography (4D-CT) is a useful tool to image tumor motion during normal respiration. Treatment margins can be reduced by targeting the motion path of the tumor. The expense and complexity of 4D-CT, however, may be cost-prohibitive at some facilities. We developed an image processing technique to produce images from cine CT that contain significant motion information without 4D-CT. The purpose of this work was to compare cine CT and 4D-CT for the purposes of target delineation and dose calculation, and to explore the role of PET in target delineation of lung cancer. Methods: To determine whether cine CT could substitute 4D-CT for small mobile lung tumors, we compared target volumes delineated by a physician on cine CT and 4D-CT for 27 tumors with intrafractional motion greater than 1 cm. We assessed dose calculation by comparing dose distributions calculated on respiratory-averaged cine CT and respiratory-averaged 4D-CT using the gamma index. A threshold-based PET segmentation model of size, motion, and source-to-background was developed from phantom scans and validated with 24 lung tumors. Finally, feasibility of integrating cine CT and PET for contouring was assessed on a small group of larger tumors. Results: Cine CT to 4D-CT target volume ratios were (1.05±0.14) and (0.97±0.13) for high-contrast and low-contrast tumors respectively which was within intraobserver variation. Dose distributions on cine CT produced good agreement (< 2%/1 mm) with 4D-CT for 71 of 73 patients. The segmentation model fit the phantom data with R2 = 0.96 and produced PET target volumes that matched CT better than 6 published methods (-5.15%). Application of the model to more complex tumors produced mixed results and further research is necessary to adequately integrate PET and cine CT for delineation. Conclusions: Cine CT can be used for target delineation of small mobile lesions with minimal differences to 4D-CT. PET, utilizing the segmentation model, can provide additional contrast. Additional research is required to assess the efficacy of complex tumor delineation with cine CT and PET. Respiratory-averaged cine CT can substitute respiratory-averaged 4D-CT for dose calculation with negligible differences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE Abundant expression of somatostatin receptors (sst) is a characteristic of neuroendocrine tumors (NET). Thus, radiolabeled somatostatin analogs have emerged as important tools for both in vivo diagnosis and therapy of NET. The two compounds most often used in functional imaging with positron emission tomography (PET) are (68)Ga-DOTATATE and (68)Ga-DOTATOC. Both analogs share a quite similar sst binding profile. However, the in vitro affinity of (68)Ga-DOTATATE in binding the sst subtype 2 (sst2) is approximately tenfold higher than that of (68)Ga-DOTATOC. This difference may affect their efficiency in detection of NET lesions, as sst2 is the predominant receptor subtype on gastroenteropancreatic NET. We thus compared the diagnostic value of PET/CT with both radiolabeled somatostatin analogs ((68)Ga-DOTATATE and (68)Ga-DOTATOC) in the same patients with gastroenteropancreatic NET. PATIENTS AND METHODS Twenty-seven patients with metastatic gastroenteropancreatic NET underwent (68)Ga-DOTATOC and (68)Ga-DOTATATE PET/CT as part of the workup before prospective peptide receptor radionuclide therapy (PRRT). The performance of both imaging methods was analyzed and compared for detection of individual lesions per patient and for eight defined body regions. A region was regarded as positive if at least one lesion was detected in that region. In addition, radiopeptide uptake in terms of the maximal standardized uptake value (SUV(max)) was compared for concordant lesions and renal parenchyma. RESULTS Fifty-one regions were found positive with both (68)Ga-DOTATATE and (68)Ga-DOTATOC. Overall, however, significantly fewer lesions were detected with (68)Ga-DOTATATE in comparison with (68)Ga-DOTATOC (174 versus 179, p < 0.05). Mean (68)Ga-DOTATATE SUV(max) across all lesions was significantly lower compared with (68)Ga-DOTATOC (16.9 ± 6.8 versus 22.1 ± 12.0, p < 0.01). Mean SUV(max) for renal parenchyma was not significantly different between (68)Ga-DOTATATE and (68)Ga-DOTATOC (12.6 ± 2.6 versus 12.6 ± 2.7). CONCLUSIONS (68)Ga-DOTATOC and (68)Ga-DOTATATE possess similar diagnostic accuracy for detection of gastroenteropancreatic NET lesions (with a potential advantage of (68)Ga-DOTATOC) despite their evident difference in affinity for sst2. Quite unexpectedly, maximal uptake of (68)Ga-DOTATOC tended to be higher than its (68)Ga-DOTATATE counterpart. However, tumor uptake shows high inter- and intraindividual variance with unpredictable preference of one radiopeptide. Thus, our data encourage the application of different sst ligands to enable personalized imaging and therapy of gastroenteropancreatic NET with optimal targeting of tumor receptors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE Computed tomography (CT) accounts for more than half of the total radiation exposure from medical procedures, which makes dose reduction in CT an effective means of reducing radiation exposure. We analysed the dose reduction that can be achieved with a new CT scanner [Somatom Edge (E)] that incorporates new developments in hardware (detector) and software (iterative reconstruction). METHODS We compared weighted volume CT dose index (CTDIvol) and dose length product (DLP) values of 25 consecutive patients studied with non-enhanced standard brain CT with the new scanner and with two previous models each, a 64-slice 64-row multi-detector CT (MDCT) scanner with 64 rows (S64) and a 16-slice 16-row MDCT scanner with 16 rows (S16). We analysed signal-to-noise and contrast-to-noise ratios in images from the three scanners and performed a quality rating by three neuroradiologists to analyse whether dose reduction techniques still yield sufficient diagnostic quality. RESULTS CTDIVol of scanner E was 41.5 and 36.4 % less than the values of scanners S16 and S64, respectively; the DLP values were 40 and 38.3 % less. All differences were statistically significant (p < 0.0001). Signal-to-noise and contrast-to-noise ratios were best in S64; these differences also reached statistical significance. Image analysis, however, showed "non-inferiority" of scanner E regarding image quality. CONCLUSIONS The first experience with the new scanner shows that new dose reduction techniques allow for up to 40 % dose reduction while still maintaining image quality at a diagnostically usable level.